Jung-Hao Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jung-Hao Wang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Gwo-Bin Lee
Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan
2 shared publications - Ching-Hsing Luo
School of Data and Computer Science, Sun Yat-sen University, Guangzhou, China
1 shared publication - Chun-Lin Cheng
Material and Chemical Research Laboratories, Industrial Technology Research Institute, 195, Sec. 4, Chung Hsing Road, Chutung, Hsinchu 31040, Taiwan
1 shared publication - Gia Thinh Bui
Department of Electrical and Mechanical Engineering, Hai Phong University, 171 Phan Dang Luu Road, Kien An District, Hai Phong City 180000, Vietnam
1 shared publication - Hsing-Cheng Yu
Department of Systems Engineering and Naval Architecture, National Taiwan Ocean University, 2 Pei-Ning Road, Keelung 20224, Taiwan
1 shared publication - Jhih-Jyun You
Material and Chemical Research Laboratories, Industrial Technology Research Institute, 195, Sec. 4, Chung Hsing Road, Chutung, Hsinchu 31040, Taiwan
1 shared publication
Latest Publications
- Open Access
Development of Miniaturized Water Quality Monitoring System Using Wireless Communication
Recently, environmental pollution resulting from industrial waste has been emerging in an endless stream. The industrial waste contains chemical materials, heavy metal ions, and other toxic materials. Once the industrial waste is discharged without standards, it might lead to water or environmental pollution. Hence, it has become more important to provide evidence-based water quality monitoring. The use of a multifunctional miniaturized water quality monitoring system (WQMS), that contains continuous monitoring, water quality monitoring, and wireless communication applications, simultaneously, is infrequent. Thus, electrodes integrated with polydimethylsiloxane flow channels were presented in this study to be a compound sensor, and the sensor can be adopted concurrently to measure temperature, pH, electrical conductivity, and copper ion concentration, whose sensitivities are determined as 0.0193 °C/mV, −0.0642 pH/mV, 1.1008 mS/V·cm (from 0 mS/cm to 2 mS/cm) and 1.1975 mS/V·cm (from 2 mS/cm to 5.07 mS/cm), and 0.0111 ppm/mV, respectively. A LoRa shield connected into the system could provide support as a node of long range wide area network (LoRaWAN) for wireless communication application. As mentioned above, the sensors, LoRa, and circuit have been integrated in this study to a continuous monitoring system, WQMS. The advantages of the multifunctional miniaturized WQMS are low cost, small size, easy maintenance, continuous sampling and long-term monitoring for many days. Every tested period is 180 min, and the measured rate is 5 times per 20 min. The feedback signals of the miniaturized WQMS and measured values of the instrument were obtained to compare the difference. In the measured results at three different place-to-place locations the errors of electrical conductivity are 0.051 mS/cm, 0.106 mS/cm, and 0.092 mS/cm, respectively. The errors of pH are 0.68, 0.87, and 0.56, respectively. The errors of temperature are 0.311 °C, 0.252 °C, and 0.304 °C, respectively. The errors of copper ion concentration are 0.051 ppm, 0.058 ppm, 0.050 ppm, respectively.
Open AccessDevelopment of Miniaturized Water Quality Monitoring System Using Wireless Communication
Recently, environmental pollution resulting from industrial waste has been emerging in an endless stream. The industrial waste contains chemical materials, heavy metal ions, and other toxic materials. Once the industrial waste is discharged without standards, it might lead to water or environmental pollution. Hence, it has become more important to provide evidence-based water quality monitoring. The use of a multifunctional miniaturized water quality monitoring system (WQMS), that contains continuous monitoring, water quality monitoring, and wireless communication applications, simultaneously, is infrequent. Thus, electrodes integrated with polydimethylsiloxane flow channels were presented in this study to be a compound sensor, and the sensor can be adopted concurrently to measure temperature, pH, electrical conductivity, and copper ion concentration, whose sensitivities are determined as 0.0193 °C/mV, −0.0642 pH/mV, 1.1008 mS/V·cm (from 0 mS/cm to 2 mS/cm) and 1.1975 mS/V·cm (from 2 mS/cm to 5.07 mS/cm), and 0.0111 ppm/mV, respectively. A LoRa shield connected into the system could provide support as a node of long range wide area network (LoRaWAN) for wireless communication application. As mentioned above, the sensors, LoRa, and circuit have been integrated in this study to a continuous monitoring system, WQMS. The advantages of the multifunctional miniaturized WQMS are low cost, small size, easy maintenance, continuous sampling and long-term monitoring for many days. Every tested period is 180 min, and the measured rate is 5 times per 20 min. The feedback signals of the miniaturized WQMS and measured values of the instrument were obtained to compare the difference. In the measured results at three different place-to-place locations the errors of electrical conductivity are 0.051 mS/cm, 0.106 mS/cm, and 0.092 mS/cm, respectively. The errors of pH are 0.68, 0.87, and 0.56, respectively. The errors of temperature are 0.311 °C, 0.252 °C, and 0.304 °C, respectively. The errors of copper ion concentration are 0.051 ppm, 0.058 ppm, 0.050 ppm, respectively.
- Open Access
- 21 December 2017
- Published by MDPI AG in Micromachines
- Vol. 9 (1) , 1
Optimization of Micropump Performance Utilizing a Single Membrane with an Active Check Valve
In this study, we successfully designed and tested a new micropump that utilizes an active check valve and bottom-protruding structure to achieve sample transportation. We performed theoretical analyses and numerical simulations to determine the optimal location of the active check valve. We also experimentally analyzed variations in the generated flow rate with respect to the pneumatic frequencies, actuated air pressures, and locations of the active check valve. The experimental results indicate the optimum air pressure, driving frequency, and location of the active check valve to be 68.9 kPa, 26.0 Hz, and 2.0 mm, respectively. We obtained a maximum pumping rate of 488 μL/min and a maximum pumping efficiency of 35.4%. The proposed micropump could perform a crucial function in the transportation of microfluids and could be incorporated into micro total analysis systems.
- 21 December 2017
- Published by MDPI AG in Micromachines
- Vol. 9 (1) , 1
Open AccessOptimization of Micropump Performance Utilizing a Single Membrane with an Active Check Valve
In this study, we successfully designed and tested a new micropump that utilizes an active check valve and bottom-protruding structure to achieve sample transportation. We performed theoretical analyses and numerical simulations to determine the optimal location of the active check valve. We also experimentally analyzed variations in the generated flow rate with respect to the pneumatic frequencies, actuated air pressures, and locations of the active check valve. The experimental results indicate the optimum air pressure, driving frequency, and location of the active check valve to be 68.9 kPa, 26.0 Hz, and 2.0 mm, respectively. We obtained a maximum pumping rate of 488 μL/min and a maximum pumping efficiency of 35.4%. The proposed micropump could perform a crucial function in the transportation of microfluids and could be incorporated into micro total analysis systems.
- Open Access
- 17 July 2013
- Published by MDPI AG in Micromachines
- Vol. 4 (3) , 306-320
Formation of Tunable, Emulsion Micro-Droplets Utilizing Flow-Focusing Channels and a Normally-Closed Micro-Valve
A mono-dispersed emulsion is of great significance in many chemical, biomedical and industrial applications. The current study reports a new microfluidic chip capable of forming tunable micro-droplets in liquids for emulsification applications. It can precisely generate size-tunable, uniform droplets using flow-focusing channels and a normally-closed valve, which is opened by a pneumatic suction force. Experimental data showed that micro-droplets with a diameter ranging from several to tens of micrometers could be precisely generated with a high uniformity. The droplet size is experimentally found to be dependent on the velocity of the dispersed-phase liquid, which is controlled by the deflection of the suction membrane. Emulsions with droplet sizes ranging from 5.5 to 55 μm are successfully observed. The variation in droplet sizes is from 3.8% to 2.5%. The micro-droplets have a uniform size and droplets smaller than those reported in previous studies are possible with this approach. This new microfluidic device can be promising for emulsification and other related applications.
- 17 July 2013
- Published by MDPI AG in Micromachines
- Vol. 4 (3) , 306-320
Open AccessFormation of Tunable, Emulsion Micro-Droplets Utilizing Flow-Focusing Channels and a Normally-Closed Micro-Valve
A mono-dispersed emulsion is of great significance in many chemical, biomedical and industrial applications. The current study reports a new microfluidic chip capable of forming tunable micro-droplets in liquids for emulsification applications. It can precisely generate size-tunable, uniform droplets using flow-focusing channels and a normally-closed valve, which is opened by a pneumatic suction force. Experimental data showed that micro-droplets with a diameter ranging from several to tens of micrometers could be precisely generated with a high uniformity. The droplet size is experimentally found to be dependent on the velocity of the dispersed-phase liquid, which is controlled by the deflection of the suction membrane. Emulsions with droplet sizes ranging from 5.5 to 55 μm are successfully observed. The variation in droplet sizes is from 3.8% to 2.5%. The micro-droplets have a uniform size and droplets smaller than those reported in previous studies are possible with this approach. This new microfluidic device can be promising for emulsification and other related applications.
- 7 October 2008
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 6 (6) , 797-809
A two-dimensional, self-compensated, microthermal cycler for one-step reverse transcription polymerase chain reaction applications
- 7 October 2008
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 6 (6) , 797-809
A two-dimensional, self-compensated, microthermal cycler for one-step reverse transcription polymerase chain reaction applications