    Influence of X-ray Tube Voltage on Computed Tomography Values and Contrast-Noise Ratios in Virtual Monoenergetic Images in routine clinical Photon Counting Detector Computed Tomography

    by Cécile R.L.P.N. Jeukens, Florentina M.E. Pinckaers, Bibi Martens, Sören Jasper, Joachim E. Wildberger, Thomas Flohr

    Purpose: Conventional energy integrating detector (EID) CT provides polyenergetic images where CT values depend on the tube voltage (kV), hampering quantitative analysis across different CT scans. To mitigate this problem, spectral CT such as photon-counting detector (PCD) CT offers virtual monoenergetic images (VMI) where CT values depend only on the keV level but, ideally, not on the tube voltage. The purpose of this study was to investigate the kV dependence of VMI CT values in PCD-CT across a wide range of tissue types, keV levels, and kV settings for various phantom sizes, and to determine which kV settings yield the optimal contrast-to-noise ratio ( CNR ) for a given VMI energy and phantom size. The phantom study was complemented with an exploratory patient study. Materials and Methods: A spectral abdomen phantom (QSA-543; QRM) with 2 optional fat rings was scanned on a PCD-CT (NAEOTOM Alpha; Siemens Healthineers). The phantom contained rods with 2/5/10/15 mg/mL iodine (QRM); muscle/fat/liver equivalent tissue; and 400 mg/mL calcium (Gammex Sun Nuclear). A standard abdomen protocol was used at tube voltages of 70/90/120/140 kV. Polyenergetic images and VMIs (range: 40 to 100 keV in 5 keV increments) were reconstructed. For each VMI energy (keV), the percentage deviation ΔCT (%) of the mean CT value across the different kV settings was determined for each rod using region-of-interest (ROI) analysis. A ΔCT of 10% was considered the clinically acceptable upper limit. For each kV setting, the iodine CNR was calculated and normalized to the radiation dose ( CTDIvol ) to obtain CNR D . Higher CNR D indicated higher radiation dose efficiency. Edge spread functions (EFS) and noise power spectra (NPS) were evaluated for various kV settings. In the retrospective patient study, a standard cerebral CT angiography (CTA) protocol was applied at either 140 kV (n = 42) or 90 kV (n = 25), with VMI reconstructed at 55 keV. Both the ΔCT (%) and the CNR D relative to the ventricles were determined for various cerebral arteries. The 2 groups were compared using unpaired t tests. Results: For all iodine and calcium rods and all phantom sizes, CT values remained stable within the predefined 10% tolerance across all kV settings in the VMI energy range of 40 to 70 keV, with ΔCT ≤8.4%. At 100 keV, ΔCT increased for low iodine concentration, reaching up to 36%, corresponding to a deviation of 19 HU from the mean CT value of 54 HU for 5 mg/mL iodine. Adipose tissue and liver exhibited ΔCT ≤10% at 45 to 70 keV. At 40 keV, deviations were larger but remained small in absolute terms (11.0 HU for liver and 19.6 HU for adipose tissue in the large phantom). For the small phantom and 40-60 keV, CNR D was 10% to 13% higher for 70/90 kV compared with 120/140 kV. EFS and NPS were consistent across kV settings. This advantage was lost at higher keV and larger phantoms. In patient VMIs at 55 keV, CNR D was 17% to 29% higher at 90 kV than at 140 kV, albeit generally not statistically significant. Conclusions: In VMIs acquired with PCD-CT, CT values were stable within the predefined 10% tolerance for all phantom sizes and tube voltages in the energy range of 45 to 70 keV, which is relevant for contrast-enhanced CT. This represents a significant step towards the meaningful comparison of CT values across different CT scans. At low keV and small phantom sizes, scans at 70 or 90 kV demonstrated greater radiation dose efficiency compared with scans at 120 or 140 kV. Therefore, for routine contrast-enhanced CT examinations of small patients or small body parts (eg, CTA of the head), scanning at low tube voltage may be considered if no spectral results other than VMIs are required.

  • Open Access

    Quantification of myocardial iron and fat—an experimental study with photon-counting detector CT

    by Philipp N Maintz, Tristan T Demmert, Thomas Flohr, Konstantin Klambauer, Lukas J Moser, Victor Mergen, Matthias Eberhard, Johannes M Froehlich, Hatem Alkadhi

    Objectives: To determine the feasibility and accuracy of photon-counting detector (PCD)-CT for iron and fat quantification in the myocardium. Methods: Cylindrical tubes were filled with porcine myocardium and iron citrate with iron concentrations of 0-20 mg Fe g−1. Dilution series were prepared with myocardium and iron (no-fat probes) and with 5% fat (fat probes). The tubes were positioned in a chest phantom and were scanned with a calcium-scoring protocol on a PCD-CT. A re-parameterized 3-material decomposition was used to separate iron and fat from myocardium. Results: On virtual monoenergetic images, attenuation increased linearly with iron concentrations in both fat and no-fat probes. In no-fat probes, linear regression yielded a slope of 1.2 HU (mg Fe g−1)−1 with an intercept of 35.8 HU (R2 = 0.964). In the fat probes, the slope was similar at 1.1 HU (mg Fe g−1)−1, while the regression line shifted downwards by 6.1 HU with an intercept of 29.6 HU (R2 = 0.985). Iron maps separated fat from iron with calculated median fat fractions of 4.85 in the fat and 0.90 in the no-fat probes. In iron images, attenuation increased linearly with increasing iron concentrations, with similar slopes between fat and no-fat probes and negligible differences in the intercept. Conclusions: Experimental evidence indicates the feasibility and accuracy of PCD-CT for iron and fat quantification in the myocardium. Iron-specific 3-material decomposition eliminates the confounding effect of fat on myocardial iron quantification. Advances in knowledge: This study highlights the value of dual-energy CT with 3-material decomposition for quantifying iron and fat in the myocardium. Thus, CT could serve as alternative for the current reference standard MRI.


  • Open Access

    High-Z Contrast Media for Coronary Photon-counting Detector CT Angiography

    by Tristan T. Demmert, Konstantin Klambauer, Bernhard Schmidt, Victor Mergen, Lukas J. Moser, Philipp N. Maintz, Thomas Allmendinger, Thomas Flohr, Hubertus Pietsch, Matthias Eberhard, et al.

    Background: Blooming artifacts from calcified plaques can obscure the vessel lumen, leading to overestimation of stenosis severity. Spectral coronary angiography with photon-counting detector CT (PCD-CT) provides virtual monoenergetic images (VMIs) for coronary artery disease assessment. While VMIs at high VMI energy levels reduce calcium blooming, iodine contrast is diminished, limiting diagnostic value. This study evaluated whether contrast media with an atomic number higher than iodine (high-Z) preserve vascular contrast using high VMI energy levels, thereby improving the accuracy of stenosis quantification. Methods: A phantom with 4 and 6 mm diameter rods to mimic small diameter vessels containing eccentric calcified plaques causing 25%, 50%, and 75% diameter stenoses was scanned with a dual-source PCD-CT system. Five different contrast media, including iodine, tungsten, holmium, hafnium, and bismuth, were tested. VMIs were reconstructed from 40 to 190 keV in 1-keV steps. Vessel attenuation, contrast-to-noise ratio (CNR), and stenoses were measured. Qualitative assessment of image quality was performed. Results: Iodine attenuation was high at lower VMI energy levels and dropped below 250 HU at >100 keV. Tungsten, holmium, hafnium, and bismuth maintained >250 HU attenuation throughout the entire energy range. Vessel CNR of iodine was high at lower and decreased at higher VMI energy levels, similar to the CNR of holmium and bismuth, though to a lesser extent. In distinction, CNRs of tungsten and hafnium were lower at lower VMI energy levels and increased to a relatively constant level at higher keV. Tungsten CNR increased with energy, approaching ~40 at high keV. Across all contrast media and stenosis degrees, stenoses were overestimated on low VMI energy levels (24% to 32.5% at 40 keV), while the degree of overestimation decreased at higher VMI energy levels (0% to 13.5% at 190 keV). At 190 keV, tungsten, hafnium, and bismuth showed ≤2.5% stenosis overestimation, compared with iodine (10% to 13.5%). Image quality varied between contrast media and energy levels: new very high-Z contrast media achieved higher scores, while iodine peaked at lower keV (55 to 70 keV) and, due to loss of contrast at higher energies, received the lowest overall scores. Conclusions: As compared with iodine, very high-Z contrast media enable superior lumen definition and more accurate stenosis assessment, also at high VMI energy levels, which minimize calcium blooming.


  • Open Access

    A Practical Rule-of-Thumb to Adapt Contrast Media Dose in Photon-counting Detector CT

    by Cécile R.L.P.N. Jeukens, Bibi Martens, Janneke Vandewall, Sören Jasper, Guy Schrijnemaekers, Joachim E. Wildberger, Thomas G. Flohr

    Objectives: To develop a simple rule-of-thumb on how to reduce the contrast medium (CM) dose in photon-counting detector CT (PCD-CT) when lowering the energy of the reconstructed virtual mono-energetic images (VMI) while maintaining the contrast-to-noise ratio (CNR) for parenchymal CT and CTA. Materials and Methods: Spectral abdominal and chest CT phantoms were scanned using a portal venous phase (PVP) abdominal and a high-pitch CTA protocol, respectively, on a first-generation dual-source PCD-CT. The phantoms contained cylindrical rods with iodine in water equivalent material (0.5/1.0/2.0/5.0/10.0/15.0 mg I/mL) and ICRU muscle tissue. The phantoms were complemented with 2 fat equivalent rings to mimic different patient sizes. Iodine contrast, image noise, noise power spectra (NPS), and iodine CNR were investigated in VMIs with different energies (40 to 60 keV in steps of 5 keV). This was done for different iodine concentrations, phantom sizes, x-ray tube voltages (120 kV and 140 kV) and radiation doses. In addition, 15 abdominal and 15 CT angiographic patient scans [body mass index (BMI) range: 17 to 37 kg/m 2 ] were retrospectively analyzed to determine the CNR at different VMI energies. Results: Contrast at a given iodine concentration and VMI energy was independent of phantom size, radiation dose, and acquisition voltage (kV). With decreasing VMI energy, the maximum of the NPS curves increased, while their shape remained similar, indicating higher noise but similar noise texture. The CNR increased with lower VMI energy for a given iodine concentration and phantom size, while CNR decreased with increasing phantom size for a given VMI energy and iodine concentration. When the VMI energy was lowered by 5 keV steps in the range of 60 to 40 keV, similar CNR could be maintained when reducing the iodine concentration at each step by 11.7% to 13.7% for abdominal PVP scans and 11.8% to 14.5% for CTAs. CNR analysis of the patient scans confirmed these findings: a 5 keV reduction in VMI energy led to a mean±SD 11.4%±0.4% and 13.7%±1.0% increase in CNR for abdomen PVP and CTA scans, respectively. This can be translated to a corresponding reduction in CM dose when a constant CNR is aimed for. From these results, a simple, robust rule-of-thumb was derived, the 10-to-5 rule: For the evaluated PCD-CT protocols, CNR can be maintained with about 10% less CM dose for each reduction of the VMI energy by 5 keV. Conclusions: This phantom study, which was complemented with a retrospective proof-of-principle patient study, showed that a simple, easy to implement 10-to-5 rule-of-thumb might be used in daily practice for contrast-enhanced PCD-CT. It allows for individual adaptation of the CM dose to the VMI energy applied.


  • Open Access

    Postoperative assessment of fracture reduction and osteosynthesis materials using photon-counting detector CT in maxillofacial trauma – a pilot study

    by Adib Al-Haj Husain, Victor Mergen, Sameena Sandhu, Maximilian Eberhard Hermann Wagner, Tristan T. Demmert, Hatem Alkadhi, Egon Burian, Thomas Flohr, Bernd Stadlinger, Peter Kessler, et al.

    Purpose: To assess postoperative fracture reduction and visualization of titanium-based and bioresorbable osteosynthesis materials in maxillofacial trauma surgery using ultra-high-resolution photon-counting detector computed tomography (PCD-CT) compared with cone-beam computed tomography (CBCT). Methods: Fractures were induced in six cadaveric pig mandibles at the angle, body, and parasymphysis and were stabilized using various titanium and bioresorbable plate systems. Specimens were scanned with CBCT and dose-matched PCD-CT in the ultra-high resolution mode, applying standard and low-dose protocols. Two observers assessed fracture reduction and implant delineation using a 5-point visual analog scale. Fracture gap and osteosynthesis materials were quantitatively measured and compared to ground-truth values. Descriptive statistics and inter-reader agreement (weighted κ) were calculated. Results: PCD-CT enabled excellent assessment of fracture reduction and visualization of osteosynthesis materials, with perfect inter-observer agreement (Median = 5, IQR, 5–5; κ = 1.0, p < 0.001), whereas low-dose CBCT showed reduced image quality and lower reproducibility (Median = 4, IQR, 4–4; κ = 0.92; p < 0.001). Bioresorbable plates were not directly visible using either scanner, but the associated screw drill holes were reliably delineated. PCD-CT achieved the smallest measurement deviations of fracture gap and osteosynthesis materials compared with ground truth, and with superior reproducibility (κ = 0.74–0.84; ICC = 0.95–0.99; all p < 0.001), outperforming CBCT across most parameters. Conclusions: Ultra-high resolution PCD-CT combines superior visualization and precise measurements compared with CBCT even at low radiation dose. With further clinical validation, these findings highlight PCD-CT’s strong potential for perioperative imaging in maxillofacial trauma, particularly benefiting younger patients who require repeated scans.


  • Open Access

    Comparative evaluation of photon-counting detector CT and cone-beam CT in the assessment of simulated mandibular trauma

    by Sameena Sandhu, Adib Al-Haj Husain, Victor Mergen, Tristan T. Demmert, Hatem Alkadhi, Thomas Flohr, Egon Burian, Bernd Stadlinger, Peter Kessler, Harald Essig, et al.


  • Artificial intelligence integration into the CT system with a focus on CT planning and scanning—review

    by Thomas Flohr, Michael Sühling

    For many years, the development of CT has been driven by technological advances in CT scanners to improve their performance, reduce radiation dose, and expand their clinical capabilities. Meanwhile, another focus of CT development has emerged—on improving and automating the scanning workflow and on approaches to better display the clinical information of CT images, supported by artificial intelligence (AI). In this review, we provide an overview of AI-driven functionalities integrated into the CT system. We discuss 3D camera-based patient positioning, patient characterization, and scan guidance, and automated scan range definition based on the localizer scan. We present approaches to automatically predict patient-specific individual scan delays for CT angiographic scans, and we discuss algorithms for AI-supported initial image quality checks. Finally, we present modern approaches that enable automatic calculation of anatomically aligned reconstructions and advanced visualizations directly on the scanner. We focus on clinically established methods, but we also present some prototype algorithms as a glimpse into the future.


  • Open Access

    In Vivo Bone Mineral Density Assessment With Spectral Localizer Radiographs From Photon-Counting Detector CT

    by Lukas Jakob Moser, Konstantin Klambauer, Maria Carolina Diaz Machicado, Diana Frey, Victor Mergen, Matthias Eberhard, Tristan Nowak, Bernhard Schmidt, Thomas Flohr, Oliver Distler, et al.

    Purpose: The aim of this study was to determine in a prospective patient study the accuracy of areal bone mineral density (aBMD) measurements with spectral localizer radiographs obtained with a clinical photon-counting detector computed tomography (PCD-CT) scanner in comparison with dual-energy x-ray absorptiometry (DXA). Methods: In this institutional review board–approved, prospective study, 41 patients (15 females, 26 males; mean age 61.3 years, age range 35–78 years) underwent PCD-CT of the abdomen with a spectral localizer radiograph (tube voltage 140 kVp, tube current 30 mA) and DXA within a median of 45 days. aBMD values were derived for lumbar vertebrae L1–L4 from both methods and were compared with linear regression, Pearson correlation, intraclass correlation coefficients (ICCs), and Bland-Altman plots. T-scores were calculated on a patient level and were compared between methods. Results: DXA and spectral localizer radiographs showed strong correlation in aBMD measurements (R = 0.97, P < 0.001) and patient level T-scores (R = 0.99, P < 0.001). There was a strong agreement between aBMD from both methods (ICC, 0.96; 95% CI, 0.94–0.97). Bland-Altman analysis revealed a very small mean difference in aBMD between methods (mean absolute error 0.019 g/cm2) with narrow limits of agreement (−0.083 g/cm2 to 0.121 g/cm2). Similarly, there were small differences in regard to the T-score (mean absolute error 0.156) with narrow limits of agreement (−0.422 to 0.734) between methods. ICCs indicated an excellent agreement between T-scores from DXA and spectral localizer radiographs (ICC, 0.98; 95% confidence interval, 0.95–0.99). Conclusions: Our prospective patient study indicates that spectral localizer radiographs obtained with a clinical PCD-CT system enable accurate quantification of the lumbar bone areal mineral density. This opens up the opportunity for opportunistic screening of osteoporosis in patients who undergo CT for other indications.


  • Photon-Counting-CT

    by Thomas Flohr