JMJohn McAughey

John McAughey

*This is an algorithmically generated author record based on publicly available information.

John McAughey has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessment of tobacco heating product THP1.0. Part 4: Characterisation of indoor air quality and odour

    by Mark Forster, John McAughey, Krishna Prasad, Eleni Mavropoulou, Christopher Proctor


  • Open Access

    Comprehensive survey of radionuclides in contemporary smokeless tobacco products

    by K. McAdam, H. Kimpton, A. Porter, C. Liu, A. Faizi, M. Mola, J. McAughey, B. Rodu

    There is considerable interest in the chemical composition of smokeless tobacco products (STPs), owing to health concerns associated with their use. Previous studies have documented levels of 210Po, 210Pb and uranium in STP samples. Here, the levels of 13 α-particle and 15 β-radiation emitting radionuclides have been measured in a broad and representative range of contemporary STPs commercially available in the United States and Sweden. For each radionuclide, the level of radioactivity and calculated mass per gram of STP are reported. The results indicate that, among 34 Swedish snus and 44 US STPs, a more complex radionuclide content exists than previously reported for these products. Of the 28 radionuclides examined, 13 were detected and quantified in one or more STPs. The most frequently identified radionuclides in these STPs were 40K, 14C, 210Po and 226Ra. Over half the STPs also contained 228Th, and an additional 8 radionuclides were identified in a small number of STPs. The presence of 14C, 3H and 230Th are reported in tobacco for the first time. The activity of β-emitters was much greater than those of α-emitters, and the β-emitter 40K was present in the STPs with both the greatest radioactivity and mass concentrations. Since the three radionuclides included in the FDA’s HPHC list were either not detected (235U), identified in only three of 78 samples (238U), and/or had activity levels over fifty times lower than that of 40K (210Po, 238U), there may be a rationale for reconsidering the radionuclides currently included in the FDA HPHC list, particularly with respect to 40K. Using a model of the physical and biological compartments which must be considered to estimate the exposure of STP users to radionuclides, we conclude that exposure from α-emitters may be minimal to STP users, but 40K in particular may expose the oral cavities of STP users to β-radiation. Although a more comprehensive picture of the radioisotope content of STPs has emerged from this study, epidemiological evidence suggests that the levels of radionuclides measured in this study appear unlikely to present significant risks to STP users.


  • Open Access

    Application of dosimetry tools for the assessment of e-cigarette aerosol and cigarette smoke generated on two different in vitro exposure systems

    by Jason Adamson, David Thorne, Benjamin Zainuddin, Andrew Baxter, John McAughey, Marianna Gaça

    The diluted aerosols from a cigarette (3R4F) and an e-cigarette (Vype ePen) were compared in two commercially available in vitro exposure systems: the Borgwaldt RM20S and Vitrocell VC10. Dosimetry was assessed by measuring deposited aerosol mass in the exposure chambers via quartz crystal microbalances, followed by quantification of deposited nicotine on their surface. The two exposure systems were shown to generate the same aerosols (pre-dilution) within analytically quantified nicotine concentration levels (p = 0.105). The dosimetry methods employed enabled assessment of the diluted aerosol at the exposure interface. At a common dilution, the per puff e-cigarette aerosol deposited mass was greater than cigarette smoke. At four dilutions, the RM20S produced deposited mass ranging 0.1–0.5 µg/cm2/puff for cigarette and 0.1–0.9 µg/cm2/puff for e-cigarette; the VC10 ranged 0.4–2.1 µg/cm2/puff for cigarette and 0.3–3.3 µg/cm2/puff for e-cigarette. In contrast nicotine delivery was much greater from the cigarette than from the e-cigarette at a common dilution, but consistent with the differing nicotine percentages in the respective aerosols. On the RM20S, nicotine ranged 2.5–16.8 ng/cm2/puff for the cigarette and 1.2–5.6 ng/cm2/puff for the e-cigarette. On the VC10, nicotine concentration ranged 10.0–93.9 ng/cm2/puff for the cigarette and 4.0–12.3 ng/cm2/puff for the e-cigarette. The deposited aerosol from a conventional cigarette and an e-cigarette in vitro are compositionally different; this emphasises the importance of understanding and characterising different product aerosols using dosimetry tools. This will enable easier extrapolation and comparison of pre-clinical data and consumer use studies, to help further explore the reduced risk potential of next generation nicotine products.


  • Open Access

    Real-time assessment of cigarette smoke particle deposition in vitro

    by Jason Adamson, Sophie Hughes, David Azzopardi, John McAughey, Marianna D Gaça

    Recently there has been a rapid increase in approaches to assess the effects of cigarette smoke in vitro. Despite a range of gravimetric and chemical methods, there is a requirement to identify simpler and more reliable methods to quantify in vitro whole smoke dose, to support extrapolation and comparisons to human/in vivo dose. We have previously characterised an in vitro exposure system using a Borgwaldt RM20S smoking machine and a chamber exposing cellular cultures to whole smoke at the air-liquid interface. In this study we demonstrate the utility of a quartz crystal microbalance (QCM), using this exposure system, to assess real-time cigarette smoke particulate deposition during a 30 minute smoke exposure. Smoke was generated at various dilutions (1:5–1:400, smoke:air) using two cigarette products, 3R4F Kentucky reference and 1 mg commercially available cigarettes. The QCM, integrated into the chamber, assessed particulate deposition and data generated were compared to traditional chemical spectrofluorometric analysis.


  • Open Access

    Assessment of an in vitro whole cigarette smoke exposure system: The Borgwaldt RM20S 8-syringe smoking machine

    by Jason Adamson, David Azzopardi, Graham Errington, Colin Dickens, John McAughey, Marianna D Gaça

    There have been many recent developments of in vitro cigarette smoke systems closely replicating in vivo exposures. The Borgwaldt RM20S smoking machine (RM20S) enables the serial dilution and delivery of cigarette smoke to exposure chambers for in vitro analyses. In this study we have demonstrated reliability and robustness testing of the RM20S in delivering smoke to in vitro cultures using an in-house designed whole smoke exposure chamber.


  • Simultaneous on-line size and chemical analysis of gas phase and particulate phase of cigarette mainstream smoke

    by Thomas Adam, John McAughey, Conor McGrath, Christoph Mocker, Ralf Zimmermann

    This paper describes the combined set-up of on-line chemical analysis of gas phase by single-photon ionisation/resonance enhanced multiphoton ionisation–time-of-flight mass spectrometry (SPI/REMPI-TOFMS) and on-line particle size analysis by differential electrical mobility particle spectrometry (DMS 500) for the investigation of fresh cigarette mainstream smoke. SPI is well suited for the investigation of a great variety of organic species, whereas REMPI is highly sensitive for aromatic compounds. Gas phase measurements of filtered and unfiltered smoke are possible with the SPI/REMPI-TOFMS in order to determine the influence of the presence of particles on the chemical composition of the gas phase. Initial results are shown for the characterisation and comparison of three pure Virginia tobacco research cigarettes having filter ventilations of 0%, i.e. no filter ventilation, 35% and 70% ventilation. The three cigarette types are smoked under two different smoking regimes, a standard regime using puff parameters equivalent to the conventional International Standard Organisation regime and a more intense smoking regime. For the gas phase, qualitative puff-by-puff resolved yields of three selected compounds (acetaldehyde, phenol and styrene) are shown and compared. For particulate matter, particle number, count median diameter and total surface area are illustrated on a puff-by-puff basis. Yields of the chemicals analysed, puff number and surface area are in good agreement with the intensity of the smoking regime and the dilution of smoke by filter ventilation. However, gaseous compounds are influenced differently, depending whether an absolute particle filter is present or not, i.e. they can be totally removed (phenol), partially removed (styrene) or not affected (acetaldehyde). For particle analysis, the count median diameter decreases from puff to puff and is strongly dependent on the smoking regime and ventilation rate. Thereby, 0% ventilated cigarettes smoked under the intense regime result in the smallest count median diameters of ca. 180 nm, whereas 70% ventilated cigarettes smoked with a standard regime lead to the largest values of up to 280 nm. As particle diameter increases, particle number decreases as a consequence of increasing time for particle coagulation.