Rajesh Purushothaman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rajesh Purushothaman has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Jojo Inassi
Department of Orthopaedics, Medical College, Calicut, 673009, India
2 shared publicationsAnwar Marthya
Department of Orthopaedics, KMCT Medical College, Manassery, 673602, India
1 shared publication- Balaji Zacharia
Department of Orthopedics, Government Medical College, Kannur, Kerala, India
1 shared publication - Dhiyaneswaran Subramaniyam
Department of Orthopedics, Government Medical College, Kozhikkode, India
1 shared publication Raju Karuppal
1 shared publicationRejith Valsalan
1 shared publication
Latest Publications
- Open Access
- 1 January 2018
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 42 (C) , 182-186
Snapping wrist due to multiple accessory tendon of first extensor compartment
Background: Snapping phenomena result from the sudden impingement between anatomical and/or heterotopical structures with subsequent abrupt movement and noise. Snaps are variously perceived by patients, from mild discomfort to significant pain requiring surgical management. snapping syndrome occurs at various site like hip, knee, shoulder and wrist. There are many cadaveric studies shows accessory tendon in first extensor compartment of wrist. Case presentation: We present a 19 year old male presents catching sensation and occasional radial side wrist pain for 6 months. Finkelstein test was negative. Radiograph showed small bony projection over the radial styloid. MRI wrist was reported as normal but retrospective analysis of image shows multiple tendons. Intraopertively we found multiple accessory tendon of extensor pollicis brevis which is causing snapping. Fibrous tunnel release with tenotomy of few accessory tendons done. On table patients catching sensation was assessed and found to be relieved. Patient is not having snapping on his follow up visit and able to carry out his daily activity without difficulties. Conclusion: There are various causes for snapping wrist syndrome. Multiple accessory tendon can also cause snapping as shown in this case report. Moreover am presenting this case to highlight the diagnostic failure with non dynamic radiological investigation and to consider multiple accessory tendon as differential diagnosis for snapping wrist syndrome. Also suggest dynamic study could be a better choice of investigation to diagnosis snapping syndrome. First compartment tunnel release with few accessory tendon slip tenotomy gives good result. Highlights:
- 1 January 2018
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 42 (C) , 182-186
Open AccessSnapping wrist due to multiple accessory tendon of first extensor compartment
Background: Snapping phenomena result from the sudden impingement between anatomical and/or heterotopical structures with subsequent abrupt movement and noise. Snaps are variously perceived by patients, from mild discomfort to significant pain requiring surgical management. snapping syndrome occurs at various site like hip, knee, shoulder and wrist. There are many cadaveric studies shows accessory tendon in first extensor compartment of wrist. Case presentation: We present a 19 year old male presents catching sensation and occasional radial side wrist pain for 6 months. Finkelstein test was negative. Radiograph showed small bony projection over the radial styloid. MRI wrist was reported as normal but retrospective analysis of image shows multiple tendons. Intraopertively we found multiple accessory tendon of extensor pollicis brevis which is causing snapping. Fibrous tunnel release with tenotomy of few accessory tendons done. On table patients catching sensation was assessed and found to be relieved. Patient is not having snapping on his follow up visit and able to carry out his daily activity without difficulties. Conclusion: There are various causes for snapping wrist syndrome. Multiple accessory tendon can also cause snapping as shown in this case report. Moreover am presenting this case to highlight the diagnostic failure with non dynamic radiological investigation and to consider multiple accessory tendon as differential diagnosis for snapping wrist syndrome. Also suggest dynamic study could be a better choice of investigation to diagnosis snapping syndrome. First compartment tunnel release with few accessory tendon slip tenotomy gives good result. Highlights:
- 24 June 2015
- Published by Elsevier in Journal of Orthopaedics
- Vol. 12 (Suppl 1) , S117-S120
Facet joint septic arthritis due to community acquired methicillin resistant Staphylococcus aureus (MRSA) – A case report
- 24 June 2015
- Published by Elsevier in Journal of Orthopaedics
- Vol. 12 (Suppl 1) , S117-S120
Facet joint septic arthritis due to community acquired methicillin resistant Staphylococcus aureus (MRSA) – A case report
- 1 May 2012
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 51 (3) , 334-336
Hallux Saltans due to Flexor Hallucis Longus Entrapment at a Previously Unreported Site in an Unskilled Manual Laborer: A Case Report
- 1 May 2012
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 51 (3) , 334-336
Hallux Saltans due to Flexor Hallucis Longus Entrapment at a Previously Unreported Site in an Unskilled Manual Laborer: A Case Report