Katsuhiro Seo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Katsuhiro Seo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Harushi Niu
Department of Medical Technologists, Division of Engineering, Kokura Memorial Hospital, 3-2-1 Asano-Kokura Kitaku, Kitakyushu City, Fukuoka 802-8555 Japan
1 shared publication - Hiroshi Miyawaki
Department of Anesthesiology and Intensive Care Medicine, Kokura Memorial Hospital, 3-2-1 Asano-Kokura Kitaku, Kitakyushu City, Fukuoka 802-8555 Japan
1 shared publication - Junichi Michikoshi
Department of Anesthesiology and Intensive Care, Faculty of Medicine, Oita University, Oita, Japan,
1 shared publication - Junya Kuribayashi
Department of Anesthesiology and Intensive Care Medicine, Kokura Memorial Hospital, 3-2-1 Asano, Kokurakita, Kitakyushu, 802-8555, Japan
1 shared publication - Katsunori Oe
Department of Anesthesiology, Showa Medical University School of Medicine, Shinagawa-Ku, Tokyo, Japan
1 shared publication - Makoto Yamamoto
Oita Kyowa Hospital, 953-1 Miyazaki, Oita City, Oita 870-1133 Japan
1 shared publication
Latest Publications
- Open Access
- 12 December 2017
- Published by Springer Nature in JA Clinical Reports
- Vol. 3 (1) , 1-4
Continuous PECS II block for postoperative analgesia in patients undergoing transapical transcatheter aortic valve implantation
It has been reported that PECS II block can alleviate postoperative pain following transapical transcatheter aortic valve implantation (TA-TAVI). However, the effectiveness of continuous PECS II block with catheterization has not yet been reported on the postoperative pain in patients undergoing TA-TAVI. We experienced two cases of TA-TAVI who received PECS II block with catheterization to manage postoperative pain. In the first case, a bolus injection for intraoperative pain and subsequent catheterization were performed before the implantation. However, the patient developed severe pain postoperatively in spite of the continuous block due to displacement of the catheter. In the second case, a bolus injection and the catheterization for the continuous block were performed before and after the implantation, respectively, which provided high-quality pain control. Continuous PECS II block may be useful to control perioperative pain associated with TA-TAVI. The insertion of the catheter after the implantation could be useful to avoid its displacement during the surgery.
- 12 December 2017
- Published by Springer Nature in JA Clinical Reports
- Vol. 3 (1) , 1-4
Open AccessContinuous PECS II block for postoperative analgesia in patients undergoing transapical transcatheter aortic valve implantation
It has been reported that PECS II block can alleviate postoperative pain following transapical transcatheter aortic valve implantation (TA-TAVI). However, the effectiveness of continuous PECS II block with catheterization has not yet been reported on the postoperative pain in patients undergoing TA-TAVI. We experienced two cases of TA-TAVI who received PECS II block with catheterization to manage postoperative pain. In the first case, a bolus injection for intraoperative pain and subsequent catheterization were performed before the implantation. However, the patient developed severe pain postoperatively in spite of the continuous block due to displacement of the catheter. In the second case, a bolus injection and the catheterization for the continuous block were performed before and after the implantation, respectively, which provided high-quality pain control. Continuous PECS II block may be useful to control perioperative pain associated with TA-TAVI. The insertion of the catheter after the implantation could be useful to avoid its displacement during the surgery.
- Open Access
- 12 January 2016
- Published by Springer Nature in Journal of Intensive Care
- Vol. 4 (1) , 1-7
Performance comparison of a new automated cuff pressure controller with currently available devices in both basic research and clinical settings
The management of tracheal tube cuff pressure in patients receiving mechanical ventilation is important for the prevention of ventilator-associated pneumonia. Currently, cuff pressure is intermittently monitored with a pressure gauge and adjusted when necessary in a routine practice. However, this method results in wide variations in pressure, and adequate management is difficult due to the spontaneous release of air from the cuff, which reduces cuff pressure. In order to continuously maintain a uniform cuff pressure, we developed a new automated cuff pressure controller and compared its properties with existing devices. The effectiveness of the new device was assessed with a model trachea/lung and tracheal tube by measuring cuff pressure while on mechanical ventilation. An electrically powered automatic cuff controller or manual cuff pressure control was used for comparison purposes. The effectiveness of the new device was also examined in patients receiving mechanical ventilation by continuously measuring cuff pressure for a 24-h period. Cuff pressure was uniformly maintained with the new device. Moreover, in the clinical setting, variation in pressure from the set pressure was minimal with both the new device and existing device, relative to the intermittent monitoring method. This suggests that, as with the existing device, uniform cuff pressure management is possible with the new device. Our results demonstrate the ability of the new cuff pressure controller to manage cuff pressure without the need of a power source, highlighting its potential utility in clinical settings.
- 12 January 2016
- Published by Springer Nature in Journal of Intensive Care
- Vol. 4 (1) , 1-7
Open AccessPerformance comparison of a new automated cuff pressure controller with currently available devices in both basic research and clinical settings
The management of tracheal tube cuff pressure in patients receiving mechanical ventilation is important for the prevention of ventilator-associated pneumonia. Currently, cuff pressure is intermittently monitored with a pressure gauge and adjusted when necessary in a routine practice. However, this method results in wide variations in pressure, and adequate management is difficult due to the spontaneous release of air from the cuff, which reduces cuff pressure. In order to continuously maintain a uniform cuff pressure, we developed a new automated cuff pressure controller and compared its properties with existing devices. The effectiveness of the new device was assessed with a model trachea/lung and tracheal tube by measuring cuff pressure while on mechanical ventilation. An electrically powered automatic cuff controller or manual cuff pressure control was used for comparison purposes. The effectiveness of the new device was also examined in patients receiving mechanical ventilation by continuously measuring cuff pressure for a 24-h period. Cuff pressure was uniformly maintained with the new device. Moreover, in the clinical setting, variation in pressure from the set pressure was minimal with both the new device and existing device, relative to the intermittent monitoring method. This suggests that, as with the existing device, uniform cuff pressure management is possible with the new device. Our results demonstrate the ability of the new cuff pressure controller to manage cuff pressure without the need of a power source, highlighting its potential utility in clinical settings.