Stanislaw Wojtkiewicz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stanislaw Wojtkiewicz has a total of 118 co-authors. Here are the top co-authors by number of shared publications:
- Adam Liebert
Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
26 shared publications - Piotr Sawosz
Nalecz Institute of Biocybernetics and Biomedical Engineering, Warsaw, Poland
10 shared publications - Hamid Dehghani
University of Birmingham
7 shared publications Roman Maniewski
Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
7 shared publications- Aleh Sudakou
Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
6 shared publications - Davide Contini
Politecnico di Milano, Dipartimento di Fisica, Milano, Italy
6 shared publications
Latest Publications
- Open Access
- 10 December 2025
- Published by Elsevier in NeuroImage
- Vol. 325, 121644
Evaluating task-evoked neurovascular coupling using integrated OPM-MEG and fNIRS imaging
- 10 December 2025
- Published by Elsevier in NeuroImage
- Vol. 325, 121644
Open AccessEvaluating task-evoked neurovascular coupling using integrated OPM-MEG and fNIRS imaging
- Open Access
- 1 December 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (12) , 5315-5331
Approaches for modelling autocorrelation function and data processing in time-domain diffuse correlation spectroscopy
Time-domain diffuse correlation spectroscopy (TD-DCS) is a non-invasive optical technique for measuring tissue blood flow. Recovering the blood flow index ( αD b ) requires accurate modelling of the normalised electric field autocorrelation function ( g 1 ), and an optimised data processing approach to minimise noise. We quantitatively compared four modelling approaches for g 1 : (i) using momentum transfer ( Y ) and pathlengths ( L ) from Monte Carlo (MC) simulations, (ii) using L only, (iii) applying an analytical solution of the photon diffusion equation (DE) in time domain, and (iv) applying an analytical solution of the correlation diffusion equation (CDE) in steady state. The second and third approaches use solutions in near-infrared spectroscopy (NIRS) for modelling g 1 in DCS by assuming Y = μ′ s L . We computed g 1 curves using the first approach, considered the gold standard, and recovered αD b using the other three approaches for various source-detector distances ( ρ ) and scattering coefficients ( μ′ s ). Also, we investigated how the correlator time bin width ( T bin ), which is an adjustable parameter in data processing, affects the standard deviation of g 1 (or the normalised intensity autocorrelation function g 2 ). We used a more convenient version of the noise equation expressed as a function of g 1 (or g 2 ), which removes the need to know the decay rate. When using photons detected after ∼0.5 ns, all four approaches produced nearly identical g 1 curves. Using all detected photons, the DE solution produced negligible errors (up to ∼2%) in the recovered αD b across various ρ and μ′ s , while using L from MC simulations resulted in larger errors (up to ∼9% at ρ = 5 mm and ∼1.5% at ρ = 30 mm). The analysis of the probability distributions P ( Y ) and P ( μ′ s L ) explained these differences. As expected, the standard deviation of g 1 (or g 2 ) can be reduced during data processing by increasing T bin . To achieve the lowest standard deviation, T bin should be longer than the inverse of the photon count rate, indicating that the optimal T bin may vary across different time gates. The results provide quantitative insights into modelling g 1 (or g 2 ), and provide a direct guideline for minimising the standard deviation of g 1 (or g 2 ) in data processing.
- 1 December 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (12) , 5315-5331
Open AccessApproaches for modelling autocorrelation function and data processing in time-domain diffuse correlation spectroscopy
Time-domain diffuse correlation spectroscopy (TD-DCS) is a non-invasive optical technique for measuring tissue blood flow. Recovering the blood flow index ( αD b ) requires accurate modelling of the normalised electric field autocorrelation function ( g 1 ), and an optimised data processing approach to minimise noise. We quantitatively compared four modelling approaches for g 1 : (i) using momentum transfer ( Y ) and pathlengths ( L ) from Monte Carlo (MC) simulations, (ii) using L only, (iii) applying an analytical solution of the photon diffusion equation (DE) in time domain, and (iv) applying an analytical solution of the correlation diffusion equation (CDE) in steady state. The second and third approaches use solutions in near-infrared spectroscopy (NIRS) for modelling g 1 in DCS by assuming Y = μ′ s L . We computed g 1 curves using the first approach, considered the gold standard, and recovered αD b using the other three approaches for various source-detector distances ( ρ ) and scattering coefficients ( μ′ s ). Also, we investigated how the correlator time bin width ( T bin ), which is an adjustable parameter in data processing, affects the standard deviation of g 1 (or the normalised intensity autocorrelation function g 2 ). We used a more convenient version of the noise equation expressed as a function of g 1 (or g 2 ), which removes the need to know the decay rate. When using photons detected after ∼0.5 ns, all four approaches produced nearly identical g 1 curves. Using all detected photons, the DE solution produced negligible errors (up to ∼2%) in the recovered αD b across various ρ and μ′ s , while using L from MC simulations resulted in larger errors (up to ∼9% at ρ = 5 mm and ∼1.5% at ρ = 30 mm). The analysis of the probability distributions P ( Y ) and P ( μ′ s L ) explained these differences. As expected, the standard deviation of g 1 (or g 2 ) can be reduced during data processing by increasing T bin . To achieve the lowest standard deviation, T bin should be longer than the inverse of the photon count rate, indicating that the optimal T bin may vary across different time gates. The results provide quantitative insights into modelling g 1 (or g 2 ), and provide a direct guideline for minimising the standard deviation of g 1 (or g 2 ) in data processing.
- Open Access
- 17 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1457-1470
Oxygen-dependent functional brain haemodynamic response
The influence of hypoxia - a condition where tissues are under oxygen deficiency - on the human brain under functional load has not been fully understood yet. This study aims to analyse the effects of hypoxia on the brain’s haemodynamic response under visual stimulation, using the in-house developed functional near-infrared spectroscopy system and to quantify the hemodynamic response. Our results (median, 25th and 75th percentile) demonstrate the amplitude of the oxygenated haemoglobin functional response during hypoxia 0.30 µM (0.27, 0.41) was lower compared with the normoxia 0.63 µM (0.54, 0.93) and hyperoxia 0.73 µM (0.43, 1.09). No statistical significance is observed for the deoxygenated haemoglobin changes. The hypoxia has a statistically significant effect on the amplitude of the haemodynamic response (p < 0.001).
- 17 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1457-1470
Open AccessOxygen-dependent functional brain haemodynamic response
The influence of hypoxia - a condition where tissues are under oxygen deficiency - on the human brain under functional load has not been fully understood yet. This study aims to analyse the effects of hypoxia on the brain’s haemodynamic response under visual stimulation, using the in-house developed functional near-infrared spectroscopy system and to quantify the hemodynamic response. Our results (median, 25th and 75th percentile) demonstrate the amplitude of the oxygenated haemoglobin functional response during hypoxia 0.30 µM (0.27, 0.41) was lower compared with the normoxia 0.63 µM (0.54, 0.93) and hyperoxia 0.73 µM (0.43, 1.09). No statistical significance is observed for the deoxygenated haemoglobin changes. The hypoxia has a statistically significant effect on the amplitude of the haemodynamic response (p < 0.001).
- 1 January 2025
- Published by Optica Publishing Group
- p. S1F.2
Measurement of Systolic and Diastolic Blood Pressure With Near Infrared Spectroscopy
The proposed method meets requirements to be the standard for measuring blood pressure due to its accuracy, robustness, pulse wave independence and implementation simplicity, making it ideal for all blood pressure devices, especially personal ones.
- 1 January 2025
- Published by Optica Publishing Group
- p. S1F.2
Measurement of Systolic and Diastolic Blood Pressure With Near Infrared Spectroscopy
The proposed method meets requirements to be the standard for measuring blood pressure due to its accuracy, robustness, pulse wave independence and implementation simplicity, making it ideal for all blood pressure devices, especially personal ones.
- 26 November 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (12) , 7035-7055
Near-infrared diffuse optical characterization of human thyroid using ultrasound-guided hybrid time-domain and diffuse correlation spectroscopies
Thyroid vascularization and hemodynamics become altered in thyroid pathologies and could thus inform diagnostics, therapy planning, and follow-up. However, the current non-invasive monitoring methods available in clinics lack the necessary sensitivity and/or are impractical for large-scale deployment. As a step towards proposing a new modality, we applied the first platform, to our knowledge, designed to do simultaneous measurements of neck anatomy and thyroid microvascular hemodynamics and metabolism in a single probe placement, integrating state-of-the-art near-infrared spectroscopy techniques and clinical ultrasound. A rich dataset was formed with sixty-five subjects (forty-eight females), including eighteen healthy volunteers and forty-seven patients with thyroid nodules, characterizing thyroid tissue and the effects of demographic and anatomical variables while preserving the standard clinical workflow. We have found marked reductions with age and body mass index in thyroid total hemoglobin concentration (THC), tissue oxygen saturation (StO2), and blood flow index (BFi), among others. Patients showed lower THC and BFi than healthy subjects, and the limited sample of malignant nodules showed a higher StO2 than the benign. These findings support the need for personalized clinical approaches.
- 26 November 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (12) , 7035-7055
Near-infrared diffuse optical characterization of human thyroid using ultrasound-guided hybrid time-domain and diffuse correlation spectroscopies
Thyroid vascularization and hemodynamics become altered in thyroid pathologies and could thus inform diagnostics, therapy planning, and follow-up. However, the current non-invasive monitoring methods available in clinics lack the necessary sensitivity and/or are impractical for large-scale deployment. As a step towards proposing a new modality, we applied the first platform, to our knowledge, designed to do simultaneous measurements of neck anatomy and thyroid microvascular hemodynamics and metabolism in a single probe placement, integrating state-of-the-art near-infrared spectroscopy techniques and clinical ultrasound. A rich dataset was formed with sixty-five subjects (forty-eight females), including eighteen healthy volunteers and forty-seven patients with thyroid nodules, characterizing thyroid tissue and the effects of demographic and anatomical variables while preserving the standard clinical workflow. We have found marked reductions with age and body mass index in thyroid total hemoglobin concentration (THC), tissue oxygen saturation (StO2), and blood flow index (BFi), among others. Patients showed lower THC and BFi than healthy subjects, and the limited sample of malignant nodules showed a higher StO2 than the benign. These findings support the need for personalized clinical approaches.
- Open Access
- 26 June 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (7) , 4330-4344
Time-domain diffuse correlation spectroscopy at large source detector separation for cerebral blood flow recovery
Time-domain diffuse correlation spectroscopy (td-DCS) enables the depth discrimination in tissue’s blood flow recovery, considering the fraction of photons detected with higher time of flight (TOF) and longer pathlength through the tissue. However, the recovery result depends on factors such as the instrument response function (IRF), analyzed TOF gate start time, gate width and the source-detector separation (SDS). In this research we evaluate the performance of the td-DCS technique at three SDSs of 1.5, 2 and 2.5 cm to recover cerebral blood flow (CBF). To do that we presented comprehensive characterization of the td-DCS system through a series of phantom experiments. First by quality metrices such as coefficient of variation and contrast-to-noise ratios, we identified optimal time gate(s) of the TOF to extract dynamics of particles. Then using sensitivity metrices, each SDS ability to detect dynamics of particles in superficial and deeper layer was evaluated. Finally, td-DCS at each SDS was tested on healthy volunteers during cuff occlusion test and breathing tasks. According to phantom measurements, the sensitivity to estimate perfusion within the deep layer located at depth of 1.5 cm from the surface can be increased more than two times when the SDS increases from 1.5 cm to 2.5 cm.
- 26 June 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (7) , 4330-4344
Open AccessTime-domain diffuse correlation spectroscopy at large source detector separation for cerebral blood flow recovery
Time-domain diffuse correlation spectroscopy (td-DCS) enables the depth discrimination in tissue’s blood flow recovery, considering the fraction of photons detected with higher time of flight (TOF) and longer pathlength through the tissue. However, the recovery result depends on factors such as the instrument response function (IRF), analyzed TOF gate start time, gate width and the source-detector separation (SDS). In this research we evaluate the performance of the td-DCS technique at three SDSs of 1.5, 2 and 2.5 cm to recover cerebral blood flow (CBF). To do that we presented comprehensive characterization of the td-DCS system through a series of phantom experiments. First by quality metrices such as coefficient of variation and contrast-to-noise ratios, we identified optimal time gate(s) of the TOF to extract dynamics of particles. Then using sensitivity metrices, each SDS ability to detect dynamics of particles in superficial and deeper layer was evaluated. Finally, td-DCS at each SDS was tested on healthy volunteers during cuff occlusion test and breathing tasks. According to phantom measurements, the sensitivity to estimate perfusion within the deep layer located at depth of 1.5 cm from the surface can be increased more than two times when the SDS increases from 1.5 cm to 2.5 cm.
- 1 June 2024
- Published by Springer Nature
- p. 170-177
Combined Measurement of Brain Activation During a Motor Task Using fNIRS and OPM-MEG
- 1 June 2024
- Published by Springer Nature
- p. 170-177
Combined Measurement of Brain Activation During a Motor Task Using fNIRS and OPM-MEG
- 4 March 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (4) , 1869-1887
Lock-in functional near-infrared spectroscopy for measurement of the haemodynamic brain response
Here we show a method of the lock-in amplifying near-infrared signals originating within a human brain. It implies using two 90-degree rotated source-detector pairs fixed on a head surface. Both pairs have a joint sensitivity region located towards the brain. A direct application of the lock-in technique on both signals results in amplifying common frequency components, e.g. related to brain cortex stimulation and attenuating the rest, including all components not related to the stimulation: e.g. pulse, instrumental and biological noise or movement artefacts. This is a self-driven method as no prior assumptions are needed and the noise model is provided by the interfering signals themselves. We show the theory (classical modified Beer-Lambert law and diffuse optical tomography approaches), the algorithm implementation and tests on a finite element mathematical model and in-vivo on healthy volunteers during visual cortex stimulation. The proposed hardware and algorithm complexity suit the entire spectrum of (continuous wave, frequency domain, time-resolved) near-infrared spectroscopy systems featuring real-time, direct, robust and low-noise brain activity registration tool. As such, this can be of special interest in optical brain computer interfaces and high reliability/stability monitors of tissue oxygenation.
- 4 March 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (4) , 1869-1887
Lock-in functional near-infrared spectroscopy for measurement of the haemodynamic brain response
Here we show a method of the lock-in amplifying near-infrared signals originating within a human brain. It implies using two 90-degree rotated source-detector pairs fixed on a head surface. Both pairs have a joint sensitivity region located towards the brain. A direct application of the lock-in technique on both signals results in amplifying common frequency components, e.g. related to brain cortex stimulation and attenuating the rest, including all components not related to the stimulation: e.g. pulse, instrumental and biological noise or movement artefacts. This is a self-driven method as no prior assumptions are needed and the noise model is provided by the interfering signals themselves. We show the theory (classical modified Beer-Lambert law and diffuse optical tomography approaches), the algorithm implementation and tests on a finite element mathematical model and in-vivo on healthy volunteers during visual cortex stimulation. The proposed hardware and algorithm complexity suit the entire spectrum of (continuous wave, frequency domain, time-resolved) near-infrared spectroscopy systems featuring real-time, direct, robust and low-noise brain activity registration tool. As such, this can be of special interest in optical brain computer interfaces and high reliability/stability monitors of tissue oxygenation.
- Open Access
- 30 September 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (10) , 6629-6650
Time-domain NIRS system based on supercontinuum light source and multi-wavelength detection: validation for tissue oxygenation studies
We present and validate a multi-wavelength time-domain near-infrared spectroscopy (TD-NIRS) system that avoids switching wavelengths and instead exploits the full capability of a supercontinuum light source by emitting and acquiring signals for the whole chosen range of wavelengths. The system was designed for muscle and brain oxygenation monitoring in a clinical environment. A pulsed supercontinuum laser emits broadband light and each of two detection modules acquires the distributions of times of flight of photons (DTOFs) for 16 spectral channels (used width 12.5 nm / channel), providing a total of 32 DTOFs at up to 3 Hz. Two emitting fibers and two detection fiber bundles allow simultaneous measurements at two positions on the tissue or at two source-detector separations. Three established protocols (BIP, MEDPHOT, and nEUROPt) were used to quantitatively assess the system’s performance, including linearity, coupling, accuracy, and depth sensitivity. Measurements were performed on 32 homogeneous phantoms and two inhomogeneous phantoms (solid and liquid). Furthermore, measurements on two blood-lipid phantoms with a varied amount of blood and Intralipid provide the strongest validation for accurate tissue oximetry. The retrieved hemoglobin concentrations and oxygen saturation match well with the reference values that were obtained using a commercially available NIRS system (OxiplexTS) and a blood gas analyzer (ABL90 FLEX), except a discrepancy occurs for the lowest amount of Intralipid. In-vivo measurements on the forearm of three healthy volunteers during arterial (250 mmHg) and venous (60 mmHg) cuff occlusions provide an example of tissue monitoring during the expected hemodynamic changes that follow previously well-described physiologies. All results, including quantitative parameters, can be compared to other systems that report similar tests. Overall, the presented TD-NIRS system has an exemplary performance evaluated with state-of-the-art performance assessment methods.
- 30 September 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (10) , 6629-6650
Open AccessTime-domain NIRS system based on supercontinuum light source and multi-wavelength detection: validation for tissue oxygenation studies
We present and validate a multi-wavelength time-domain near-infrared spectroscopy (TD-NIRS) system that avoids switching wavelengths and instead exploits the full capability of a supercontinuum light source by emitting and acquiring signals for the whole chosen range of wavelengths. The system was designed for muscle and brain oxygenation monitoring in a clinical environment. A pulsed supercontinuum laser emits broadband light and each of two detection modules acquires the distributions of times of flight of photons (DTOFs) for 16 spectral channels (used width 12.5 nm / channel), providing a total of 32 DTOFs at up to 3 Hz. Two emitting fibers and two detection fiber bundles allow simultaneous measurements at two positions on the tissue or at two source-detector separations. Three established protocols (BIP, MEDPHOT, and nEUROPt) were used to quantitatively assess the system’s performance, including linearity, coupling, accuracy, and depth sensitivity. Measurements were performed on 32 homogeneous phantoms and two inhomogeneous phantoms (solid and liquid). Furthermore, measurements on two blood-lipid phantoms with a varied amount of blood and Intralipid provide the strongest validation for accurate tissue oximetry. The retrieved hemoglobin concentrations and oxygen saturation match well with the reference values that were obtained using a commercially available NIRS system (OxiplexTS) and a blood gas analyzer (ABL90 FLEX), except a discrepancy occurs for the lowest amount of Intralipid. In-vivo measurements on the forearm of three healthy volunteers during arterial (250 mmHg) and venous (60 mmHg) cuff occlusions provide an example of tissue monitoring during the expected hemodynamic changes that follow previously well-described physiologies. All results, including quantitative parameters, can be compared to other systems that report similar tests. Overall, the presented TD-NIRS system has an exemplary performance evaluated with state-of-the-art performance assessment methods.
- Open Access
- 2 August 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (9) , 5351-5367
Performance assessment of laser sources for time-domain diffuse correlation spectroscopy
Time-domain diffuse correlation spectroscopy (TD-DCS) is an emerging optical technique that enables noninvasive measurement of microvascular blood flow with photon path-length resolution. In TD-DCS, a picosecond pulsed laser with a long coherence length, adequate illumination power, and narrow instrument response function (IRF) is required, and satisfying all these features is challenging. To this purpose, in this study we characterized the performance of three different laser sources for TD-DCS. First, the sources were evaluated based on their emission spectrum and IRF. Then, we compared the signal-to-noise ratio and the sensitivity to velocity changes of scattering particles in a series of phantom measurements. We also compared the results for in vivo measurements, performing an arterial occlusion protocol on the forearm of three adult subjects. Overall, each laser has the potential to be successfully used both for laboratory and clinical applications. However, we found that the effects caused by the IRF are more significant than the effect of a limited temporal coherence.
- 2 August 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (9) , 5351-5367
Open AccessPerformance assessment of laser sources for time-domain diffuse correlation spectroscopy
Time-domain diffuse correlation spectroscopy (TD-DCS) is an emerging optical technique that enables noninvasive measurement of microvascular blood flow with photon path-length resolution. In TD-DCS, a picosecond pulsed laser with a long coherence length, adequate illumination power, and narrow instrument response function (IRF) is required, and satisfying all these features is challenging. To this purpose, in this study we characterized the performance of three different laser sources for TD-DCS. First, the sources were evaluated based on their emission spectrum and IRF. Then, we compared the signal-to-noise ratio and the sensitivity to velocity changes of scattering particles in a series of phantom measurements. We also compared the results for in vivo measurements, performing an arterial occlusion protocol on the forearm of three adult subjects. Overall, each laser has the potential to be successfully used both for laboratory and clinical applications. However, we found that the effects caused by the IRF are more significant than the effect of a limited temporal coherence.