PAPatrick Roberto Avelino

Patrick Roberto Avelino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Patrick Roberto Avelino has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Agreement Between In‐Person and Remote Administration of the Clinical‐Functional Vulnerability Index‐20 for Frailty Screening in Older Adults

    by Wallacy Junio Pena Araujo, Julia Almeida Teixeira Quintão, Bruno Barcelos, Vinícius Pinto Coelho Vieira, Patrick Roberto Avelino, Kênia Kiefer Parreiras de Menezes

    Objective: To investigate the agreement between the in‐person and remote (telephone and online) administration of the Clinical‐Functional Vulnerability Index‐20 (IVCF‐20) for the frailty assessment of older adults. Methods: In this methodological study, the IVCF‐20 was applied in three different formats: in‐person, telephone (voice call), and online (Google Forms). The order of administration was random, and the interval between sessions was five–seven days. The participants were individuals aged > 60 years and had the cognitive ability to answer simple questions. The Intraclass Correlation Coefficient (ICC) was used to assess the level of agreement between the total scores obtained through the three methods, and the weighted kappa for agreement between the scores of each item. Results: Fifty‐six older adults were included in the study. The level of agreement for the total scores between the IVCF‐20 and IVCF‐20‐Remote applied by telephone was high (ICC = 0.87), while the Kappa coefficient ranged from 0.22 (Item 14) to 1.0 (Item 1). The level of agreement for the total scores between the IVCF‐20 and IVCF‐20‐Remote applied online was high (ICC = 0.90), while the Kappa coefficient ranged from 0.23 (Item 14) to 1.0 (Item 1). Conclusion: This study demonstrated high agreement between the IVCF‐20 and the IVCF‐20‐Remote (telephone and online). Thus, IVCF‐20‐Remote has emerged as a viable alternative for screening older adults, expanding access to geriatric assessment, and promoting continuity of care.

  • Agreement Between In‐Person and Telephone Application of the Informant Questionnaire on Cognitive Decline in the Elderly

    by Luiz Henrique Sabino Silva, Renner Vinicius da Silva, Paula Pinto Coelho, Patrick Roberto Avelino, Kênia Kiefer Parreiras de Menezes

    Background and Purpose: Remote cognitive assessment has gained prominence due to limited access to in‐person services. The purpose was to investigate the agreement between in‐person and telephone administration of the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE). Methods: For this methodological study, the IQCODE was administered to the caregiver or family member of the older adults in‐person and by telephone. The order of the administration modalities was randomized, with the assessments conducted 5–7 days apart. Each participant was assessed by two different and previously trained researchers, who were blinded to the previous assessment. The intraclass correlation coefficient (ICC) was used to assess the level of agreement between the total and item scores obtained using the two methods. Results: The study included 51 individuals. There were no statistically significant differences between the two methods ( p = 0.227). Regarding the total score, a high ICC (ICC = 0.74) was observed. Regarding the items, the ICCs ranged from 0.17 to 0.98, representing low to high agreement. Conclusion: The telephone assessment of the IQCODE showed adequate agreement with the in‐person assessment for evaluating cognitive decline in older adults. Therefore, telephone‐based assessments may be used in clinical and research settings via telephone interviews, expanding access to cognitive assessment and contributing to more inclusive care strategies.

  • Scoring Method, Testing Method and Learning Effect of the Upper Extremity Motor Coordination Test

    by Davi Pereira Rodrigues de Jesus, Rafael Geraldo de Sá, Patrick Roberto Avelino, Paula Pinto Coelho, Vinícius Pinto Coelho Vieira, Kênia Kiefer Parreiras de Menezes

    Objective: To evaluate the best scoring method (first trial, mean of the first and last two trials, and mean of three trials), best testing method (direct/video), and learning effect of the Upper Extremity Motor Coordination Test (UEMOCOT). Methods: The UEMOCOT was performed three times and recorded using a video camera. The learning effects investigated the differences across the three trials, using ANOVAs, which was also used to investigate the best scoring method. The intraclass correlation coefficient (ICC–2.1) verified the agreement between direct/video observations. Results: Significant differences were found between the scoring methods (7.7 ≤ F ≤ 28.1, p < 0.001), and across the three trials (5.3 ≤ F ≤ 22.2, p < 0.010). There was a very high agreement between the direct and video scores (0.94 ≤ ICC ≤ 0.98). Conclusion: Although the results for the best scoring method and learning effect were statistically significant, the values were lower than the smallest real difference previously established, suggesting that only one measurement is necessary, with no clinically relevant learning effect. In addition, it can be scored personally and by video.

  • Open Access

    FisioCare Neurogroup: A new application for home monitoring of individuals with neurological diseases

    by Patrick R. Avelino, Kênia K. P. Menezes, Christina Danielli Coelho de Morais Faria, Lucas R. Nascimento, Maria Tereza Mota Alvarenga, Ruani Tenório Araújo, Aline A. Scianni

    Objective: The objective of this study was to develop a smartphone application (app) that will be programmed with home exercises for the patient to perform. Methods: The present app was developed in five stages: (1) Software content analysis and setting of objectives, (2) Preliminary layout, (3) Development of the prototype, (4) Testing the prototype, and (5) Finalisation. All stages were conducted by two physiotherapist researchers with at least 10 years of experience. Results: In the first stage, the app named FisioCare Neurogroup was established with one interface for the physiotherapist and one for the patient. Ten physiotherapists assessed the preliminary layout in the second stage, and after the prototype was developed in the third stage, it was tested by another 10 physiotherapists with their respective neurological patients in the fourth stage. Most physiotherapists reported ease of use, with no adjustments proposed at the end. Finally, the app was finalized in the fifth stage. The proposed app allows the physiotherapist to register a specific exercise program for each patient to be carried out at home. The patient will be able to access the program described and demonstrated in detail. The app will notify both the patient of the need to perform the activities and the physiotherapist of the patient’s performance of the exercises. Conclusion: The FisioCare Neurogroup was developed according to standardized protocols that are highly recommended for this purpose. This app may improve the performance of the patient in the home exercises, as well as their autonomy, by monitoring the adherence of the patient to the protocol proposed.

  • Development of a Brazilian mHealth App For the Assessment of Health, Functionality, and Quality of Life of Individuals With Stroke: AVALIE AVC

    by Kênia Kiefer Parreiras de Menezes, Patrick Roberto Avelino, Aline Alvim Scianni, Lucas Rodrigues Nascimento, Luci Fuscaldi Teixeira‐Salmela, Christina Danielli Coelho de Morais Faria

    Background and Purpose: To describe the development of an mHealth app that includes various instruments for the assessment of individuals with stroke. Methods: The app was developed following the report by the Agency for Healthcare Research and Quality as follows: (1) Software content analysis; (2) Preliminary layout; (3) Development of the prototype; (4) Testing the prototype; and (5) Finalization. All stages were conducted by two researchers with at least 12 years of experience in neurorehabilitation. Six researchers participated on an expert committee at stages 1 and 2, and 10 physiotherapists participated at stages 2 and 4. Results: The app was named AVALIE AVC (EVALUATE CVA). After the five stages, which included a pilot test with 10 physiotherapists, the app was finalized including 46 instruments, organized into 26 categories, with adequate measurement properties for individuals with stroke. For each instrument, there are descriptions and indications, materials/time needed for application, a copy of the questionnaires/scales or illustrative pictures/videos of the tests, and the score calculation and interpretation. Discussion: The AVALIE AVC was developed according to standardized protocols, is available on both Android and iOS platforms, and is free of charge, containing 46 instruments for the assessment of health, functionality, and quality of life in stroke individuals. This application has the potential to assist healthcare professionals in assessing patients after a stroke by providing the necessary information quickly and easily.

  • Reference Values, Test‐Retest Reliability, Standard Error of Measurement and Smallest Real Difference of the Finger to Nose Test

    by Giovana Almeida Silva Santos, Sara Petersen Monteiro, Patrick Roberto Avelino, Vinícius Pinto Coelho Vieira, Paula Pinto Coelho, Kênia Kiefer Parreiras de Menezes

    Background and Purpose: To investigate the test‐retest reliability, the standard error of measurement (SEM), and the smallest real difference (SRD) of the finger to nose test, as well as establish its reference values, according to sex, age, and dominant limb. Methods: Individuals were requested to touch a 6 cm target, fixed in front of them, as quickly as possible for 20 s, first with the dominant limb and then with the non‐dominant limb. In order to assess test‐retest reliability, the test was administered two times, in 30 individuals, 5–7 days apart. In order to establish the Finger to Nose reference values, at least 30 individuals (15 women and 15 men) in each follow age group were collected: 20–29, 30–39, 40–49, 50–59 and over 60 years old. Test‐retest reliability was assessed using the intraclass correlation coefficient (ICC). The SEM and SRD were calculated from the ICC. Results: One hundred and sixty‐five individuals were assessed. The test‐retest reliability of the Finger to Nose showed good values, with an ICC of 0.92 for the dominant limb and 0.86 for the non‐dominant limb. The SEM values were < 15%, being 9% for the dominant limb and 11% for the non‐dominant limb, and were also considered adequate. Regarding the SRD, the values found were 7 points for the dominant limb and 8 points for the non‐dominant limb. Finally, reference values were established based on sex, age and limb dominance. Discussion: This study showed that the Finger to Nose test has good reliability for assessing upper limb motor coordination. In addition, changes of at least 7 points in the dominant limb and 8 in the non‐dominant limb are necessary to be considered clinical changes in the patient. Finally, reference values were defined based on sex, age and dominance, offering support for future assessments and interventions.

  • Depression symptoms best explained insomnia complaints after stroke – a cross-sectional study

    by Ruani Araújo Tenório, Patrick Roberto Avelino, Luciano Fonseca Lemos de Oliveira, Christina Danielli Coelho de Morais Faria, Luci Fuscaldi Teixeira-Salmela, Andressa Silva, Aline Alvim Scianni


  • Health indicators of older adults in a stroke unit in Brazil and their role in explaining disability, functional dependence, and residual motor impairments at hospital discharge

    by Kênia Kiefer Parreiras de Menezes, Iza de Faria-Fortini, Patrick Roberto Avelino, Luci Fuscaldi Teixeira-Salmela, Aline Alvim Scianni, Christina Danielli Coelho de Morais Faria

  • Development, Measurement Properties and Reference Values of the Upper Extremity Motor Coordination Test: A New Motor Coordination Test of the Upper Limbs

    by João Victor Drummond Ribeiro, Josué Rodrigues da Silva, Laura Júnia Leite Paulo, Patrick Roberto Avelino, Kênia Kiefer Parreiras de Menezes

    Background and Purpose: To develop a new test to assess the motor coordination of the upper limbs, and to investigate the test‐retest and inter‐rater reliability, construct validity, standard error of measurement (SEM), minimum detectable change (MDC), and the reference values.Methods: The Upper Extremity Motor Coordination Test (UEMOCOT)was applied for 20 s, with the individual touching two targets (one right and one left) as quickly as possible, first with the hand (manual task) and then with the index finger (finger task). To test‐retest reliability, the UEMOCOT was administered two times. To ensure inter‐rater reliability, the test was scored simultaneously by two assessors. For convergent construct validity, the Box and Block Test (BBT) and the Nine Hole Peg Test (NHPT) were applied. Reference values were established according to sex, age, and limb side (dominant/non‐dominant).Results: Inter‐rater and test‐retest reliability, for both tasks and limbs, were good with all the intraclass correlation coefficient above 0.90. Regarding convergent construct validity, the UEMOCOT manual task, for both sides, correlated moderately with BBT (0.59 ≤ r ≤ 0.64; p < 0.01), while the UEMOCOT finger task, for both sides, correlated moderately with NHPT (−0.57 ≤ r ≤ −0,58; p < 0.01). The SEM values were adequate, and the MDC for manual and finger tasks were 11/8 and 6/6 (dominant/non‐dominant), respectively. Young people, men, and the dominant limb showed higher scores, indicating better coordination.Discussion: The results showed that UEMOCOT is valid and reliable for assessing the motor coordination of the upper limbs, with adequate SEM values and MDC values ranging from 6 to 11. Finally, UEMOCOT reference values were established according to sex, age, and upper limb side.


  • Open Access

    Efeitos do treino de dupla tarefa na marcha e equilíbrio de indivíduos pós-acidente vascular encefálico: uma revisão sistemática com metanálise

    by Ally Summer Santiago Procópio, Deivid Barbosa Portilho, Patrick Roberto Avelino, Kênia Kiefer Parreiras de Menezes

    RESUMO Este artigo objetiva investigar os efeitos do treino de dupla tarefa na marcha e equilíbrio de pacientes pós-acidente vascular encefálico (AVE), por meio de uma revisão sistemática com metanálise de ensaios clínicos de adequada qualidade metodológica. Foram feitas buscas nas bases de dados eletrônicas PubMed, LILACS, SciELO e PEDro, até setembro de 2024, por dois avaliadores independentes. Incluiu-se ensaios clínicos aleatorizados que realizaram o treino baseado em dupla tarefa em indivíduos pós-AVE, com nota média na escala PEDro igual ou superior a seis. As medidas de desfecho de interesse foram aquelas relacionadas à marcha e/ou equilíbrio, podendo ser avaliadas através de testes ou questionários. A qualidade metodológica dos estudos foi avaliada através da escala PEDro. Oito estudos foram incluídos. De maneira geral, o treino de dupla tarefa se mostrou eficaz para melhora da velocidade da marcha em 0,11m/s (IC95% 0,02 a 0,21; I2=11%; p=0,02), cadência em 7,30 passos/minuto (IC95% 2,46 a 12,14; I2=0%; p=0,003), e equilíbrio (SMD 0,45; IC95% 0,08 a 0,81; I2=36%; p=0,02). Não foram encontrados resultados significativos para comprimento da passada (MD 1,72; IC95% –9,15 a 12,59; I2=22%; p=0,76), e mobilidade (IC95% –5,64 a 1,88; I2=0%; p=0,33). Esta revisão sistemática evidenciou, por meio de uma metanálise, que o treino de dupla tarefa é capaz de melhorar de forma significativa a velocidade de marcha, cadência e equilíbrio em pacientes pós-AVE. Porém, é recomendado que novos ensaios clínicos de qualidade metodológica superior sejam realizados, em especial investigando os efeitos para mobilidade e equilíbrio.