Jesse V. McClain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jesse V. McClain has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Amanda L. Burger
Behavioral Medicine, St. Elizabeth Family Medicine Residency, 1053 Belmont Ave., Youngstown, OH, 44504, USA
1 shared publication - C. Michael Dunham
Trauma, Critical Care, and General Surgery Services, St. Elizabeth Youngstown Hospital, Youngstown, USA
1 shared publication
Latest Publications
- Open Access
- 29 November 2017
- Published by Springer Nature in BMC Research Notes
- Vol. 10 (1) , 640
Comparison of Bispectral Index™ values during the flotation restricted environmental stimulation technique and results for stage I sleep: a prospective pilot investigation
To determine whether Bispectral Index™ values obtained during flotation-restricted environment stimulation technique have a similar profile in a single observation compared to literature-derived results found during sleep and other relaxation-induction interventions. Bispectral Index™ values were as follows: awake-state, 96.6; float session-1, 84.3; float session-2, 82.3; relaxation-induction, 82.8; stage I sleep, 86.0; stage II sleep, 66.2; and stages III–IV sleep, 45.1. Awake-state values differed from float session-1 (%difference 12.7%; Cohen’s d = 3.6) and float session-2 (%difference 14.8%; Cohen’s d = 4.6). Relaxation-induction values were similar to float session-1 (%difference 1.8%; Cohen’s d = 0.3) and float session-2 (%difference 0.5%; Cohen’s d = 0.1). Stage I sleep values were similar to float session-1 (%difference 1.9%; Cohen’s d = 0.4) and float session-2 (%difference 4.3%; Cohen’s d = 1.0). Stage II sleep values differed from float session-1 (%difference 21.5%; Cohen’s d = 4.3) and float session-2 (%difference 19.6%; Cohen’s d = 4.0). Stages III–IV sleep values differed from float session-1 (%difference 46.5%; Cohen’s d = 5.6) and float session-2 (%difference 45.2%; Cohen’s d = 5.4). Bispectral Index™ values during flotation were comparable to those found in stage I sleep and nadir values described with other relaxation-induction techniques.
- 29 November 2017
- Published by Springer Nature in BMC Research Notes
- Vol. 10 (1) , 640
Open AccessComparison of Bispectral Index™ values during the flotation restricted environmental stimulation technique and results for stage I sleep: a prospective pilot investigation
To determine whether Bispectral Index™ values obtained during flotation-restricted environment stimulation technique have a similar profile in a single observation compared to literature-derived results found during sleep and other relaxation-induction interventions. Bispectral Index™ values were as follows: awake-state, 96.6; float session-1, 84.3; float session-2, 82.3; relaxation-induction, 82.8; stage I sleep, 86.0; stage II sleep, 66.2; and stages III–IV sleep, 45.1. Awake-state values differed from float session-1 (%difference 12.7%; Cohen’s d = 3.6) and float session-2 (%difference 14.8%; Cohen’s d = 4.6). Relaxation-induction values were similar to float session-1 (%difference 1.8%; Cohen’s d = 0.3) and float session-2 (%difference 0.5%; Cohen’s d = 0.1). Stage I sleep values were similar to float session-1 (%difference 1.9%; Cohen’s d = 0.4) and float session-2 (%difference 4.3%; Cohen’s d = 1.0). Stage II sleep values differed from float session-1 (%difference 21.5%; Cohen’s d = 4.3) and float session-2 (%difference 19.6%; Cohen’s d = 4.0). Stages III–IV sleep values differed from float session-1 (%difference 46.5%; Cohen’s d = 5.6) and float session-2 (%difference 45.2%; Cohen’s d = 5.4). Bispectral Index™ values during flotation were comparable to those found in stage I sleep and nadir values described with other relaxation-induction techniques.