Vicki E. Noble
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vicki E. Noble has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Irene Wai Yan Ma
Department of Medicine, University of Calgary, Calgary, Canada
2 shared publications - Aftab Azad
Division of Emergency Ultrasound, Department of Emergency Medicine, Massachusetts General Hospital, 326 Cambridge Street, Suite 410, Boston, MA, 02114, USA
1 shared publication - Akira Nishisaki
The Children’s Hospital of Philadelphia, Philadelphia
1 shared publication - Alfred Abuhamad
Department of Obstetrics and Gynecology, Eastern Virginia Medical School, Norfolk, VA, USA
1 shared publication - Andrew S. Liteplo
Emergency Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, USA
1 shared publication - Anjali Bhagra
Division of General Internal Medicine, Mayo Clinic, Rochester, MN
1 shared publication
Latest Publications
- 11 October 2023
- Published by Springer Nature
- p. 1-6
The Evolution of Point of Care Ultrasound
- Top Cited PapersOpen Access
- 27 July 2022
- Published by Mattioli1885 in The Ultrasound Journal
- Vol. 14 (1) , 1-32
International consensus conference recommendations on ultrasound education for undergraduate medical students
Objectives: The purpose of this study is to provide expert consensus recommendations to establish a global ultrasound curriculum for undergraduate medical students. Methods: 64 multi-disciplinary ultrasound experts from 16 countries, 50 multi-disciplinary ultrasound consultants, and 21 medical students and residents contributed to these recommendations. A modified Delphi consensus method was used that included a systematic literature search, evaluation of the quality of literature by the GRADE system, and the RAND appropriateness method for panel judgment and consensus decisions. The process included four in-person international discussion sessions and two rounds of online voting. Results: A total of 332 consensus conference statements in four curricular domains were considered: (1) curricular scope (4 statements), (2) curricular rationale (10 statements), (3) curricular characteristics (14 statements), and (4) curricular content (304 statements). Of these 332 statements, 145 were recommended, 126 were strongly recommended, and 61 were not recommended. Important aspects of an undergraduate ultrasound curriculum identified include curricular integration across the basic and clinical sciences and a competency and entrustable professional activity-based model. The curriculum should form the foundation of a life-long continuum of ultrasound education that prepares students for advanced training and patient care. In addition, the curriculum should complement and support the medical school curriculum as a whole with enhanced understanding of anatomy, physiology, pathophysiological processes and clinical practice without displacing other important undergraduate learning. The content of the curriculum should be appropriate for the medical student level of training, evidence and expert opinion based, and include ongoing collaborative research and development to ensure optimum educational value and patient care. Conclusions: The international consensus conference has provided the first comprehensive document of recommendations for a basic ultrasound curriculum. The document reflects the opinion of a diverse and representative group of international expert ultrasound practitioners, educators, and learners. These recommendations can standardize undergraduate medical student ultrasound education while serving as a basis for additional research in medical education and the application of ultrasound in clinical practice.
- 27 July 2022
- Published by Mattioli1885 in The Ultrasound Journal
- Vol. 14 (1) , 1-32
Top Cited PapersOpen AccessInternational consensus conference recommendations on ultrasound education for undergraduate medical students
Objectives: The purpose of this study is to provide expert consensus recommendations to establish a global ultrasound curriculum for undergraduate medical students. Methods: 64 multi-disciplinary ultrasound experts from 16 countries, 50 multi-disciplinary ultrasound consultants, and 21 medical students and residents contributed to these recommendations. A modified Delphi consensus method was used that included a systematic literature search, evaluation of the quality of literature by the GRADE system, and the RAND appropriateness method for panel judgment and consensus decisions. The process included four in-person international discussion sessions and two rounds of online voting. Results: A total of 332 consensus conference statements in four curricular domains were considered: (1) curricular scope (4 statements), (2) curricular rationale (10 statements), (3) curricular characteristics (14 statements), and (4) curricular content (304 statements). Of these 332 statements, 145 were recommended, 126 were strongly recommended, and 61 were not recommended. Important aspects of an undergraduate ultrasound curriculum identified include curricular integration across the basic and clinical sciences and a competency and entrustable professional activity-based model. The curriculum should form the foundation of a life-long continuum of ultrasound education that prepares students for advanced training and patient care. In addition, the curriculum should complement and support the medical school curriculum as a whole with enhanced understanding of anatomy, physiology, pathophysiological processes and clinical practice without displacing other important undergraduate learning. The content of the curriculum should be appropriate for the medical student level of training, evidence and expert opinion based, and include ongoing collaborative research and development to ensure optimum educational value and patient care. Conclusions: The international consensus conference has provided the first comprehensive document of recommendations for a basic ultrasound curriculum. The document reflects the opinion of a diverse and representative group of international expert ultrasound practitioners, educators, and learners. These recommendations can standardize undergraduate medical student ultrasound education while serving as a basis for additional research in medical education and the application of ultrasound in clinical practice.
- Open Access
- 22 November 2017
- Published by Springer Nature in The Ultrasound Journal
- Vol. 9 (1) , 1-8
The Assessment of Competency in Thoracic Sonography (ACTS) scale: validation of a tool for point-of-care ultrasound
The rapid adoption of point-of-care ultrasound (POCUS) has created a need to develop assessment tools to ensure that learners can competently use these technologies. In this study, the authors developed and tested a rating scale to assess the quality of point-of-care thoracic ultrasound studies performed by novices. In Phase 1, the Assessment of Competency in Thoracic Sonography (ACTS) scale was developed based on structured interviews with subject matter experts. The tool was then piloted on a small series of ultrasound studies in Phase 2. In Phase 3 the tool was applied to a sample of 150 POCUS studies performed by ten learners; performance was then assessed by two independent raters. Evidence for the content validity of the ACTS scale was provided by a consensus exercise wherein experts agreed on the general principles and specific items that make up the scale. The tool demonstrated reasonable inter-rater reliability despite minimal requirements for evaluator training and displayed evidence of good internal structure, with related scale items correlating well with each other. Analysis of the aggregate learning curves suggested a rapid early improvement in learner performance with slower improvement after approximately 25–30 studies. The ACTS scale provides a straightforward means to assess learner performance. Our results support the conclusion that the tool is an effective means of making valid judgments regarding competency in point-of-care thoracic ultrasound, and that the majority of learner improvement occurs during their first 25–30 practice studies.
- 22 November 2017
- Published by Springer Nature in The Ultrasound Journal
- Vol. 9 (1) , 1-8
Open AccessThe Assessment of Competency in Thoracic Sonography (ACTS) scale: validation of a tool for point-of-care ultrasound
The rapid adoption of point-of-care ultrasound (POCUS) has created a need to develop assessment tools to ensure that learners can competently use these technologies. In this study, the authors developed and tested a rating scale to assess the quality of point-of-care thoracic ultrasound studies performed by novices. In Phase 1, the Assessment of Competency in Thoracic Sonography (ACTS) scale was developed based on structured interviews with subject matter experts. The tool was then piloted on a small series of ultrasound studies in Phase 2. In Phase 3 the tool was applied to a sample of 150 POCUS studies performed by ten learners; performance was then assessed by two independent raters. Evidence for the content validity of the ACTS scale was provided by a consensus exercise wherein experts agreed on the general principles and specific items that make up the scale. The tool demonstrated reasonable inter-rater reliability despite minimal requirements for evaluator training and displayed evidence of good internal structure, with related scale items correlating well with each other. Analysis of the aggregate learning curves suggested a rapid early improvement in learner performance with slower improvement after approximately 25–30 studies. The ACTS scale provides a straightforward means to assess learner performance. Our results support the conclusion that the tool is an effective means of making valid judgments regarding competency in point-of-care thoracic ultrasound, and that the majority of learner improvement occurs during their first 25–30 practice studies.
- Open Access
- 20 April 2017
- Published by Springer Nature in The Ultrasound Journal
- Vol. 9 (1) , 1-8
Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements
Non-invasive measures that can accurately estimate cardiac output may help identify volume-responsive patients. This study seeks to compare two non-invasive measures (corrected carotid flow time and carotid blood flow) and their correlations with invasive reference measurements of cardiac output. Consenting adult patients (n = 51) at Massachusetts General Hospital cardiac catheterization laboratory undergoing right heart catheterization between February and April 2016 were included. Carotid ultrasound images were obtained concurrently with cardiac output measurements, obtained by the thermodilution method in the absence of severe tricuspid regurgitation and by the Fick oxygen method otherwise. Corrected carotid flow time was calculated as systole time/√cycle time. Carotid blood flow was calculated as π × (carotid diameter)2/4 × velocity time integral × heart rate. Measurements were obtained using a single carotid waveform and an average of three carotid waveforms for both measures. Single waveform measurements of corrected flow time did not correlate with cardiac output (ρ = 0.25, 95% CI −0.03 to 0.49, p = 0.08), but an average of three waveforms correlated significantly, although weakly (ρ = 0.29, 95% CI 0.02–0.53, p = 0.046). Carotid blood flow measurements correlated moderately with cardiac output regardless of if single waveform or an average of three waveforms were used: ρ = 0.44, 95% CI 0.18–0.63, p = 0.004, and ρ = 0.41, 95% CI 0.16–0.62, p = 0.004, respectively. Carotid blood flow may be a better marker of cardiac output and less subject to measurements issues than corrected carotid flow time.
- 20 April 2017
- Published by Springer Nature in The Ultrasound Journal
- Vol. 9 (1) , 1-8
Open AccessCorrelation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements
Non-invasive measures that can accurately estimate cardiac output may help identify volume-responsive patients. This study seeks to compare two non-invasive measures (corrected carotid flow time and carotid blood flow) and their correlations with invasive reference measurements of cardiac output. Consenting adult patients (n = 51) at Massachusetts General Hospital cardiac catheterization laboratory undergoing right heart catheterization between February and April 2016 were included. Carotid ultrasound images were obtained concurrently with cardiac output measurements, obtained by the thermodilution method in the absence of severe tricuspid regurgitation and by the Fick oxygen method otherwise. Corrected carotid flow time was calculated as systole time/√cycle time. Carotid blood flow was calculated as π × (carotid diameter)2/4 × velocity time integral × heart rate. Measurements were obtained using a single carotid waveform and an average of three carotid waveforms for both measures. Single waveform measurements of corrected flow time did not correlate with cardiac output (ρ = 0.25, 95% CI −0.03 to 0.49, p = 0.08), but an average of three waveforms correlated significantly, although weakly (ρ = 0.29, 95% CI 0.02–0.53, p = 0.046). Carotid blood flow measurements correlated moderately with cardiac output regardless of if single waveform or an average of three waveforms were used: ρ = 0.44, 95% CI 0.18–0.63, p = 0.004, and ρ = 0.41, 95% CI 0.16–0.62, p = 0.004, respectively. Carotid blood flow may be a better marker of cardiac output and less subject to measurements issues than corrected carotid flow time.