Maram A. Wahba
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Maram A. Wahba has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Amira Salah Ashour
Department of Electronics and Electrical Communications Engineering, Faculty of Engineering, Tanta University, Tanta, Egypt
7 shared publications Mustafa M. Abd Elnaby
Department of Electronics and Electrical Communications Engineering, Faculty of Engineering, Tanta University, Tanta, Egypt
2 shared publications- Rami Ghannam
James Watt School of Engineering University of Glasgow Glasgow UK
2 shared publications Yanhui Guo
University of Illinois at Springfield
2 shared publications- Abeer Abd Elhakam Hodeib
Department of Dermatology and Venereology, Faculty of Medicine, Tanta University, Tanta 31511, Egypt
1 shared publication Ahmed Refaat Hawas
Tanta University
1 shared publication
Latest Publications
- Open Access
- 21 September 2024
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 84 (24) , 27747-27775
DermCompressNet: integrated CD-ConvNet and discrete cosine transform for dermoscopic images compression
Telemedicine has a critical role in healthcare by supporting the information exchange between the patients and the physicians as well as between the physicians for consultation. Such technology has urgent requirements for storage reduction and efficient use of the transmission channel bandwidth. Such requirements can be achieved efficiently via developing accurate medical image compression techniques. For accurate diagnosis, lossless compression methods are recommended. However, the tradeoff between the compression ratio (CR) and the preservation of the image quality is still challenging. On the other hand, the advantages of the convolutional neural networks inspired this work to design a novel proposed system for dermoscopic image compression based on the integration of the compression direction-ConvNet (CD-ConvNet) and decompression direction-ConvNet (DD-ConvNet) with discrete cosine transform (DCT) and Huffman coding, called DermCompressNet. To reconstruct a high-quality image at the receiver, the inverse processes using the DD-ConvNet network were followed. The proposed system was evaluated by measuring several image quality metrics, namely the mean square error (MSE), peak signal-to-noise ratio (PSNR), and structural similarity index measure (SSIM), along with compression quality metrics, namely CR, and computational time (CT). The experimental results achieved 34.6 dB, 2.5, 0.85, and 56% of PSNR, MSE, SSIM, and CR, respectively. A comparison studies with the JPEG and state-of-the-art methods proved the superiority of the proposed system, showing23%, 16%, 4.3%, and 1.8% improvements in the PSNR, MSE, SSIM, and CR, respectively, compared to the JPEG.
- 21 September 2024
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 84 (24) , 27747-27775
Open AccessDermCompressNet: integrated CD-ConvNet and discrete cosine transform for dermoscopic images compression
Telemedicine has a critical role in healthcare by supporting the information exchange between the patients and the physicians as well as between the physicians for consultation. Such technology has urgent requirements for storage reduction and efficient use of the transmission channel bandwidth. Such requirements can be achieved efficiently via developing accurate medical image compression techniques. For accurate diagnosis, lossless compression methods are recommended. However, the tradeoff between the compression ratio (CR) and the preservation of the image quality is still challenging. On the other hand, the advantages of the convolutional neural networks inspired this work to design a novel proposed system for dermoscopic image compression based on the integration of the compression direction-ConvNet (CD-ConvNet) and decompression direction-ConvNet (DD-ConvNet) with discrete cosine transform (DCT) and Huffman coding, called DermCompressNet. To reconstruct a high-quality image at the receiver, the inverse processes using the DD-ConvNet network were followed. The proposed system was evaluated by measuring several image quality metrics, namely the mean square error (MSE), peak signal-to-noise ratio (PSNR), and structural similarity index measure (SSIM), along with compression quality metrics, namely CR, and computational time (CT). The experimental results achieved 34.6 dB, 2.5, 0.85, and 56% of PSNR, MSE, SSIM, and CR, respectively. A comparison studies with the JPEG and state-of-the-art methods proved the superiority of the proposed system, showing23%, 16%, 4.3%, and 1.8% improvements in the PSNR, MSE, SSIM, and CR, respectively, compared to the JPEG.
- Open Access
- 4 December 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (12) , 3040
Cascaded Hough Transform-Based Hair Mask Generation and Harmonic Inpainting for Automated Hair Removal from Dermoscopy Images
Restoring information obstructed by hair is one of the main issues for the accurate analysis and segmentation of skin images. For retrieving pixels obstructed by hair, the proposed system converts dermoscopy images into the L*a*b* color space, then principal component analysis (PCA) is applied to produce grayscale images. Afterward, the contrast-limited adaptive histogram equalization (CLAHE) and the average filter are implemented to enhance the grayscale image. Subsequently, the binary image is generated using the iterative thresholding method. After that, the Hough transform (HT) is applied to each image block to generate the hair mask. Finally, the hair pixels are removed by harmonic inpainting. The performance of the proposed automated hair removal was evaluated by applying the proposed system to the International Skin Imaging Collaboration (ISIC) dermoscopy dataset as well as to clinical images. Six performance evaluation metrics were measured, namely the mean squared error (MSE), the peak signal-to-noise ratio (PSNR), the signal-to-noise ratio (SNR), the structural similarity index (SSIM), the universal quality image index (UQI), and the correlation (C). Using the clinical dataset, the system achieved MSE, PSNR, SNR, SSIM, UQI, and C values of 34.7957, 66.98, 42.39, 0.9813, 0.9801, and 0.9985, respectively. The results demonstrated that the proposed system could satisfy the medical diagnostic requirements and achieve the best performance compared to the state-of-art.
- 4 December 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (12) , 3040
Open AccessCascaded Hough Transform-Based Hair Mask Generation and Harmonic Inpainting for Automated Hair Removal from Dermoscopy Images
Restoring information obstructed by hair is one of the main issues for the accurate analysis and segmentation of skin images. For retrieving pixels obstructed by hair, the proposed system converts dermoscopy images into the L*a*b* color space, then principal component analysis (PCA) is applied to produce grayscale images. Afterward, the contrast-limited adaptive histogram equalization (CLAHE) and the average filter are implemented to enhance the grayscale image. Subsequently, the binary image is generated using the iterative thresholding method. After that, the Hough transform (HT) is applied to each image block to generate the hair mask. Finally, the hair pixels are removed by harmonic inpainting. The performance of the proposed automated hair removal was evaluated by applying the proposed system to the International Skin Imaging Collaboration (ISIC) dermoscopy dataset as well as to clinical images. Six performance evaluation metrics were measured, namely the mean squared error (MSE), the peak signal-to-noise ratio (PSNR), the signal-to-noise ratio (SNR), the structural similarity index (SSIM), the universal quality image index (UQI), and the correlation (C). Using the clinical dataset, the system achieved MSE, PSNR, SNR, SSIM, UQI, and C values of 34.7957, 66.98, 42.39, 0.9813, 0.9801, and 0.9985, respectively. The results demonstrated that the proposed system could satisfy the medical diagnostic requirements and achieve the best performance compared to the state-of-art.
- 1 July 2021
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 68, 102656
Ensemble-based bag of features for automated classification of normal and COVID-19 CXR images
- 1 July 2021
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 68, 102656
Ensemble-based bag of features for automated classification of normal and COVID-19 CXR images
- Open Access
- 25 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 78883-78901
A Cascaded Classification-Segmentation Reversible System for Computer-Aided Detection and Cells Counting in Microscopic Peripheral Blood Smear Basophils and Eosinophils Images
Computer-aided image analysis has a pivotal role in automated counting and classification of white blood cells (WBCs) in peripheral blood images. Due to their different characteristics, our proposed approach is based on investigating the variations between the basophils and eosinophils in terms of their color histogram, size, and shape before performing the segmentation process. Accordingly, we proposed a cascaded system using a classification-based segmentation process, called classification-segmentation reversible system (CSRS). Prior to applying the CSRS system, a Histogram-based Object to Background Disparity (HOBD) metric was deduced to determine the most appropriate color plane for performing the initial WBC detection (first segmentation). Investigating the local histogram features of both classes resulted in a 92.4% initial classification accuracy using the third-degree polynomial support vector machine (SVM) method. Subsequently, in the proposed CSRS approach, transformation-based segmentation algorithms were developed to fit the specific requirements of each of the two predicted classes. The proposed CSRS system is used, where the images from an initial classification process are fed into a second segmentation process for each class separately. The segmentation results demonstrated a similarity index of 94.9% for basophils, and 94.1% for eosinophils. Moreover, an average counting accuracy of 97.4% for both classes was achieved. In addition, a second classification was carried out after applying the CSRS, achieving a 5.2% increase in accuracy compared to the initial classification process.
- 25 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 78883-78901
Open AccessA Cascaded Classification-Segmentation Reversible System for Computer-Aided Detection and Cells Counting in Microscopic Peripheral Blood Smear Basophils and Eosinophils Images
Computer-aided image analysis has a pivotal role in automated counting and classification of white blood cells (WBCs) in peripheral blood images. Due to their different characteristics, our proposed approach is based on investigating the variations between the basophils and eosinophils in terms of their color histogram, size, and shape before performing the segmentation process. Accordingly, we proposed a cascaded system using a classification-based segmentation process, called classification-segmentation reversible system (CSRS). Prior to applying the CSRS system, a Histogram-based Object to Background Disparity (HOBD) metric was deduced to determine the most appropriate color plane for performing the initial WBC detection (first segmentation). Investigating the local histogram features of both classes resulted in a 92.4% initial classification accuracy using the third-degree polynomial support vector machine (SVM) method. Subsequently, in the proposed CSRS approach, transformation-based segmentation algorithms were developed to fit the specific requirements of each of the two predicted classes. The proposed CSRS system is used, where the images from an initial classification process are fed into a second segmentation process for each class separately. The segmentation results demonstrated a similarity index of 94.9% for basophils, and 94.1% for eosinophils. Moreover, an average counting accuracy of 97.4% for both classes was achieved. In addition, a second classification was carried out after applying the CSRS, achieving a 5.2% increase in accuracy compared to the initial classification process.
- Open Access
- 15 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 170336-170354
Prediction of Harvestable Energy for Self-Powered Wearable Healthcare Devices: Filling a Gap
Self-powered or autonomously driven wearable devices are touted to revolutionize the personalized healthcare industry, promising sustainable medical care for a large population of healthcare seekers. Current wearable devices rely on batteries for providing the necessary energy to the various electronic components. However, to ensure continuous and uninterrupted operation, these wearable devices need to scavenge energy from their surroundings. Different energy sources have been used to power wearable devices. These include predictable energy sources such as solar energy and radio frequency, as well as unpredictable energy from the human body. Nevertheless, these energy sources are either intermittent or deliver low power densities. Therefore, being able to predict or forecast the amount of harvestable energy over time enables the wearable to intelligently manage and plan its own energy resources more effectively. Several prediction approaches have been proposed in the context of energy harvesting wireless sensor network (EH-WSN) nodes. In their architectural design, these nodes are very similar to self-powered wearable devices. However, additional factors need to be considered to ensure a deeper market penetration of truly autonomous wearables for healthcare applications, which include low-cost, low-power, small-size, high-performance and lightweight. In this paper, we review the energy prediction approaches that were originally proposed for EH-WSN nodes and critique their application in wearable healthcare devices. Our comparison is based on their prediction accuracy, memory requirement, and execution time. We conclude that statistical techniques are better designed to meet the needs of short-term predictions, while long-term predictions require the hybridization of several linear and non-linear machine learning techniques. In addition to the recommendations, we discuss the challenges and future perspectives of these technique in our review.
- 15 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 170336-170354
Open AccessPrediction of Harvestable Energy for Self-Powered Wearable Healthcare Devices: Filling a Gap
Self-powered or autonomously driven wearable devices are touted to revolutionize the personalized healthcare industry, promising sustainable medical care for a large population of healthcare seekers. Current wearable devices rely on batteries for providing the necessary energy to the various electronic components. However, to ensure continuous and uninterrupted operation, these wearable devices need to scavenge energy from their surroundings. Different energy sources have been used to power wearable devices. These include predictable energy sources such as solar energy and radio frequency, as well as unpredictable energy from the human body. Nevertheless, these energy sources are either intermittent or deliver low power densities. Therefore, being able to predict or forecast the amount of harvestable energy over time enables the wearable to intelligently manage and plan its own energy resources more effectively. Several prediction approaches have been proposed in the context of energy harvesting wireless sensor network (EH-WSN) nodes. In their architectural design, these nodes are very similar to self-powered wearable devices. However, additional factors need to be considered to ensure a deeper market penetration of truly autonomous wearables for healthcare applications, which include low-cost, low-power, small-size, high-performance and lightweight. In this paper, we review the energy prediction approaches that were originally proposed for EH-WSN nodes and critique their application in wearable healthcare devices. Our comparison is based on their prediction accuracy, memory requirement, and execution time. We conclude that statistical techniques are better designed to meet the needs of short-term predictions, while long-term predictions require the hybridization of several linear and non-linear machine learning techniques. In addition to the recommendations, we discuss the challenges and future perspectives of these technique in our review.
- Open Access
- 5 May 2018
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 12 (7) , 1311-1318
A novel optimized neutrosophic k-means using genetic algorithm for skin lesion detection in dermoscopy images
- 5 May 2018
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 12 (7) , 1311-1318
Open AccessA novel optimized neutrosophic k-means using genetic algorithm for skin lesion detection in dermoscopy images
- 30 October 2017
- Published by Springer Nature in Health Information Science and Systems
- Vol. 5 (1) , 1-13
Combined empirical mode decomposition and texture features for skin lesion classification using quadratic support vector machine
Purpose Basal cell carcinoma is one of the most common malignant skin lesions. Automated lesion identification and classification using image processing techniques is highly required to reduce the diagnosis errors. Methods In this study, a novel technique is applied to classify skin lesion images into two classes, namely the malignant Basal cell carcinoma and the benign nevus. A hybrid combination of bi-dimensional empirical mode decomposition and gray-level difference method features is proposed after hair removal. The combined features are further classified using quadratic support vector machine (Q-SVM). Results The proposed system has achieved outstanding performance of 100% accuracy, sensitivity and specificity compared to other support vector machine procedures as well as with different extracted features. Conclusion Basal Cell Carcinoma is effectively classified using Q-SVM with the proposed combined features.
- 30 October 2017
- Published by Springer Nature in Health Information Science and Systems
- Vol. 5 (1) , 1-13
Combined empirical mode decomposition and texture features for skin lesion classification using quadratic support vector machine
Purpose Basal cell carcinoma is one of the most common malignant skin lesions. Automated lesion identification and classification using image processing techniques is highly required to reduce the diagnosis errors. Methods In this study, a novel technique is applied to classify skin lesion images into two classes, namely the malignant Basal cell carcinoma and the benign nevus. A hybrid combination of bi-dimensional empirical mode decomposition and gray-level difference method features is proposed after hair removal. The combined features are further classified using quadratic support vector machine (Q-SVM). Results The proposed system has achieved outstanding performance of 100% accuracy, sensitivity and specificity compared to other support vector machine procedures as well as with different extracted features. Conclusion Basal Cell Carcinoma is effectively classified using Q-SVM with the proposed combined features.