VGVinicius Schott Gameiro

Vinicius Schott Gameiro

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vinicius Schott Gameiro has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Characterization and Applicability of a Bone Spheroid Model for the Evaluation of Cytocompatibility of Bone Substitutes

    by Ana Carolina Batista Brochado, Daniela Costa Silva, Joice Correa da Silva, Adam Lowenstein, Vinicius Schott Gameiro, Elena Mavropoulos, Carlos F. Mourão, Gutemberg Gomes Alves

    In vitro cell-based tests are an important preclinical step for the safety assessment of biomaterials and drugs. Three-dimensional cell culture models (3D) may improve the limitations of the usual 2D models, as they better simulate a physiological environment. This work describes the characterization of a 3D spheroid model of MC3T3-E1 murine preosteoblasts for the testing of bone-substitute materials and investigates its adequacy to some of the most employed cell viability tests. The spheroids presented structural stability for 28 days in culture, with a regular spheroidal aspect, compact surface, and dense inner structure, with high potential for mineralization, but a time-dependent reduction in size. The use of colorimetric tests (MTT, XTT, and NRU) did not achieve satisfactory optical densities and did not correlate with cell density in the 3D model, as the aggregates remain strongly stained even after dye extraction steps. On the other hand, the LDH test achieved appropriate optical density and a high correlation with cell density (r2 = 0.77) and identified a dose–response for a well-known cytotoxic polymer (latex), while no toxicity was identified for biocompatible PLA wires. These results indicate that material testing with 3D bone cell models requires a careful choice of test methods and parameters.


  • Open Access

    Osteosphere Model to Evaluate Cell–Surface Interactions of Implantable Biomaterials

    by Ana Carolina Batista Brochado, Victor Hugo de Souza, Joice Correa, Suzana Azevedo dos Anjos, Carlos Fernando de Almeida Barros Mourão, Angelo Cardarelli, Pietro Montemezzi, Vinicius Schott Gameiro, Mariana Rodrigues Pereira, Elena Mavropoulos, et al.

    Successful biomaterials for bone tissue therapy must present different biocompatible properties, such as the ability to stimulate the migration and proliferation of osteogenic cells on the implantable surface, to increase attachment and avoid the risks of implant movement after surgery. The present work investigates the applicability of a three-dimensional (3D) model of bone cells (osteospheres) in the evaluation of osteoconductive properties of different implant surfaces. Three different titanium surface treatments were tested: machined (MA), sandblasting and acid etching (BE), and Hydroxyapatite coating by plasma spray (PSHA). The surfaces were characterized by Scanning Electron Microscopy (SEM) and atomic force microscopy (AFM), confirming that they present very distinct roughness. After seeding the osteospheres, cell–surface interactions were studied in relation to cell proliferation, migration, and spreading. The results show that BE surfaces present higher densities of cells, leaving the aggregates towards than titanium surfaces, providing more evidence of migration. The PSHA surface presented the lowest performance in all analyses. The results indicate that the 3D model allows the focal analysis of an in vitro cell/surfaces interaction of cells and surfaces. Moreover, by demonstrating the agreement with the clinical data observed in the literature, they suggest a potential use as a predictive preclinical tool for investigating osteoconductive properties of novel biomaterials for bone therapy.