Oliver Blume
Oliver Blume has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Florian Andreas Probst
Department of Oral and Maxillofacial Surgery and Facial Plastic Surgery , University Hospital, LMU , Munich , Germany
2 shared publications - Jan Ir Wildenhof
Dentist, Privatzahnklinik Schloss Schellenstein, 59939 Olsberg, Germany
2 shared publications - Michael Back
Private Practice Dres. Back & Blume, Munich, Germany
2 shared publications - Sven Otto
Department of Oral and Maxillofacial Surgery and Facial Plastic Surgery, University Hospital, LMU Munich, Lindwurmstrasse 2a, 80337 Munich, Germany
2 shared publications - Eva Maria Schnödt
Department of Oral and Maxillofacial Surgery and Facial Plastic Surgery, Ludwig-Maximilians-University, Munich, Germany
1 shared publication - Joerg Franke
Department of Trauma and Orthopaedic Surgery, Elbe Klinikum Stade, Bremervörder Strasse 111, 21682, Stade, Germany.
1 shared publication
Latest Publications
- Open Access
- 22 July 2025
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 55 (2) , 256-262
CAD/CAM manufactured allogeneic bone blocks for three-dimensional ridge augmentation in implant dentistry: a retrospective clinical and radiological analysis
- 22 July 2025
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 55 (2) , 256-262
Open AccessCAD/CAM manufactured allogeneic bone blocks for three-dimensional ridge augmentation in implant dentistry: a retrospective clinical and radiological analysis
- 1 July 2021
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 36 (4) , 762-770
Influence of Clinical Parameters on the Primary Stability of a Tapered Dental Implant: A Retrospective Analysis
Oliver Blume, MD, DDS/Jan Wildenhof, DDS/Sven Otto, MD, DDS/Florian A. Probst, MD, DDS: Purpose: The aim of this study was to investigate the influence of different clinical parameters on the primary stability of a variable thread tapered implant system with a focus on surgical undersizing protocols. Materials and Methods: This retrospective study evaluated patients who received NobelActive implants in a single institution. The relationship between the independent variables, bone quality, implant diameter, implant length, implantation time, region of the jaw, and surgical undersizing protocol, and the dependent variable, maximum insertion torque, was investigated. Statistical analysis was conducted using analysis of variance (ANOVA) and multiple linear regression. Results: A total of 1,292 implants placed in 574 fully or partially edentulous patients were evaluated. For the total sample size, without further differentiation between bone qualities, statistically significantly higher primary stability values were shown for an 8% to 9% undersized group (50.33 ± 17.16 Ncm), compared with a 16% undersized group (41.88 ± 17.63 Ncm), a 20% undersized group (33.65 ± 15.78 Ncm), a 26% to 28% undersized group (34.53 ± 15.49 Ncm), and a 35% to 44% undersized group (32.78 ± 18.80 Ncm). No statistical differences were found for undersizing protocols in bone quality 4. Bone quality had the highest influence on primary stability (Welch-Test F(3, 65.57) = 119.48, P < .001, η2 = .20). Contrary to the other investigated independent variables, no statistically significant differences in primary stability were found for the different implantation times. Conclusion: Undersizing protocols exceeding 8% to 9% do not seem to enhance primary stability values. Further studies are needed to investigate the biologic consequences of undersizing, including the impact of implant design characteristics.
- 1 July 2021
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 36 (4) , 762-770
Influence of Clinical Parameters on the Primary Stability of a Tapered Dental Implant: A Retrospective Analysis
Oliver Blume, MD, DDS/Jan Wildenhof, DDS/Sven Otto, MD, DDS/Florian A. Probst, MD, DDS: Purpose: The aim of this study was to investigate the influence of different clinical parameters on the primary stability of a variable thread tapered implant system with a focus on surgical undersizing protocols. Materials and Methods: This retrospective study evaluated patients who received NobelActive implants in a single institution. The relationship between the independent variables, bone quality, implant diameter, implant length, implantation time, region of the jaw, and surgical undersizing protocol, and the dependent variable, maximum insertion torque, was investigated. Statistical analysis was conducted using analysis of variance (ANOVA) and multiple linear regression. Results: A total of 1,292 implants placed in 574 fully or partially edentulous patients were evaluated. For the total sample size, without further differentiation between bone qualities, statistically significantly higher primary stability values were shown for an 8% to 9% undersized group (50.33 ± 17.16 Ncm), compared with a 16% undersized group (41.88 ± 17.63 Ncm), a 20% undersized group (33.65 ± 15.78 Ncm), a 26% to 28% undersized group (34.53 ± 15.49 Ncm), and a 35% to 44% undersized group (32.78 ± 18.80 Ncm). No statistical differences were found for undersizing protocols in bone quality 4. Bone quality had the highest influence on primary stability (Welch-Test F(3, 65.57) = 119.48, P < .001, η2 = .20). Contrary to the other investigated independent variables, no statistically significant differences in primary stability were found for the different implantation times. Conclusion: Undersizing protocols exceeding 8% to 9% do not seem to enhance primary stability values. Further studies are needed to investigate the biologic consequences of undersizing, including the impact of implant design characteristics.
- Open Access
Long-Term Efficacy of Variable-Thread Tapered Implants—A Retrospective, Clinical and Radiological Evaluation
Background and Objective: There is multifaceted evidence that variable-thread tapered implants (VTTIs) offer high primary stability but few regarding the long-term success. This retrospective clinical and radiological cohort study assessed the long-term outcome of VTTIs. Material and Methods: All patients treated in an OMFS practice with NobelActive Internal® VTTI between October 2007 and September 2011 were invited for clinical examination. The outcome variables were (i) survival rate, (ii) implant success according to the “Health Scale for Dental Implants” and (iii) prevalence of peri-implantitis. Furthermore, the effect of local and systemic risk factors was investigated. Results: In 81 subjects (46 females and 35 males, mean age 65.6 years) 270 implants (157 VTTIs and 113 others as a control group) were analyzed. In 7 out of 81 patients (8.6%), 8 out of 157 VTTIs (5.1%) and 5 out of 113 other implants (4.4%) were lost. Peri-implantitis, defined as (i) presence of bleeding on gentle probing (0.25 N) or exudation and (ii) radiographic bone loss exceeding 0.5 mm since implant insertion to last follow-up, was the most common reason for implant loss (11 out of 13, 84.6%). Sixty-six out of 87 VTTIs (75.9%) were successful. Seventeen out of 42 patients (40.5%) developed peri-implantitis on 29 out of 79 VTTI sites (36.7%). Plaque and missing keratinized peri-implant mucosa were identified as potential risk factors for the development of peri-implantitis. Conclusion: Variable-thread tapered implants showed good long-term results, even in low bone quality. Peri-implantitis was the most common reason for implant failure and may be connected to certain risk factors.
Open AccessLong-Term Efficacy of Variable-Thread Tapered Implants—A Retrospective, Clinical and Radiological Evaluation
Background and Objective: There is multifaceted evidence that variable-thread tapered implants (VTTIs) offer high primary stability but few regarding the long-term success. This retrospective clinical and radiological cohort study assessed the long-term outcome of VTTIs. Material and Methods: All patients treated in an OMFS practice with NobelActive Internal® VTTI between October 2007 and September 2011 were invited for clinical examination. The outcome variables were (i) survival rate, (ii) implant success according to the “Health Scale for Dental Implants” and (iii) prevalence of peri-implantitis. Furthermore, the effect of local and systemic risk factors was investigated. Results: In 81 subjects (46 females and 35 males, mean age 65.6 years) 270 implants (157 VTTIs and 113 others as a control group) were analyzed. In 7 out of 81 patients (8.6%), 8 out of 157 VTTIs (5.1%) and 5 out of 113 other implants (4.4%) were lost. Peri-implantitis, defined as (i) presence of bleeding on gentle probing (0.25 N) or exudation and (ii) radiographic bone loss exceeding 0.5 mm since implant insertion to last follow-up, was the most common reason for implant loss (11 out of 13, 84.6%). Sixty-six out of 87 VTTIs (75.9%) were successful. Seventeen out of 42 patients (40.5%) developed peri-implantitis on 29 out of 79 VTTI sites (36.7%). Plaque and missing keratinized peri-implant mucosa were identified as potential risk factors for the development of peri-implantitis. Conclusion: Variable-thread tapered implants showed good long-term results, even in low bone quality. Peri-implantitis was the most common reason for implant failure and may be connected to certain risk factors.
- Open Access
Treatment of Severely Resorbed Maxilla Due to Peri-Implantitis by Guided Bone Regeneration Using a Customized Allogenic Bone Block: A Case Report
The objective of this case report is to introduce a customized CAD/CAM freeze-dried bone allograft (FDBA) block for its use in Guided Bone Regeneration (GBR) procedures for severely deficient maxillary bones. Additionally, a special newly developed remote incision technique is presented to avoid wound dehiscence. The results show optimal integration behavior of the FDBA block after six months and the formation of new vital bone. Thus, the results of the present case report confirm the use of the customized CAD/CAM bone block for augmentation of complex defects in the maxillary aesthetic zone as a successful treatment concept.
Open AccessTreatment of Severely Resorbed Maxilla Due to Peri-Implantitis by Guided Bone Regeneration Using a Customized Allogenic Bone Block: A Case Report
The objective of this case report is to introduce a customized CAD/CAM freeze-dried bone allograft (FDBA) block for its use in Guided Bone Regeneration (GBR) procedures for severely deficient maxillary bones. Additionally, a special newly developed remote incision technique is presented to avoid wound dehiscence. The results show optimal integration behavior of the FDBA block after six months and the formation of new vital bone. Thus, the results of the present case report confirm the use of the customized CAD/CAM bone block for augmentation of complex defects in the maxillary aesthetic zone as a successful treatment concept.