Hirohito Ishii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hirohito Ishii has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Kunihide Nakamura
Division of Cardiovascular Surgery, Department of Surgery, University of Miyazaki, Miyazaki, Japan
3 shared publicationsEisaku Nakamura
Division of Cardiovascular Surgery, Department of Surgery, University of Miyazaki, Miyazaki, Japan
2 shared publicationsGeorge Endo
Department of Surgery, Division of Cardiovascular Surgery, University of Miyazaki, Miyazaki, Miyazaki, Japan
2 shared publicationsKoji Furukawa
Division of Cardiovascular Surgery, Department of Surgery, University of Miyazaki, Miyazaki, Japan
2 shared publicationsHiroki Mori
Department of Surgery, Division of Cardiovascular Surgery, University of Miyazaki, Miyazaki, Miyazaki, Japan
1 shared publicationHiroyuki Nagahama
Department of Surgery II, Faculty of Medicine, University of Miyazaki, Miyazaki, Miyazaki, Japan
1 shared publication
Latest Publications
- Open Access
- 1 January 2017
- Published by The Editorial Committee of Annals of Vascular Diseases in Annals of Vascular Diseases
- Vol. 10 (3) , 261-264
Successful Embolization Therapy through Reentry Tear in the Right Subclavian Artery for Treating Patent False Lumen in the Aortic Arch Formed after Type A Dissection Repair
A 73-year-old woman had undergone hemiarch replacement with primary entry resection for treating acute type A dissection 6 years ago. Postoperative computed tomography (CT) showed a patent false lumen (FL) in the aortic arch and a reentry tear in the right subclavian artery. The remaining aortic arch enlarged, which resulted in formation of a 55-mm-diameter aneurysm. We performed reentry occlusion using embolization with glue and coil. The patient’s clinical course after the procedure was uneventful, and subsequent CT showed that FL was thrombosed and had decreased in size.
- 1 January 2017
- Published by The Editorial Committee of Annals of Vascular Diseases in Annals of Vascular Diseases
- Vol. 10 (3) , 261-264
Open AccessSuccessful Embolization Therapy through Reentry Tear in the Right Subclavian Artery for Treating Patent False Lumen in the Aortic Arch Formed after Type A Dissection Repair
A 73-year-old woman had undergone hemiarch replacement with primary entry resection for treating acute type A dissection 6 years ago. Postoperative computed tomography (CT) showed a patent false lumen (FL) in the aortic arch and a reentry tear in the right subclavian artery. The remaining aortic arch enlarged, which resulted in formation of a 55-mm-diameter aneurysm. We performed reentry occlusion using embolization with glue and coil. The patient’s clinical course after the procedure was uneventful, and subsequent CT showed that FL was thrombosed and had decreased in size.
- 1 January 2016
- Published by The Editorial Committee of Annals of Vascular Diseases in Annals of Vascular Diseases
- Vol. 9 (4) , 349-351
Aortic Pseudoaneurysm due to Simple Vertebral Compression Fracture Treated with Conservative Management
Blunt aortic injures are rarely associated with minimal trauma. We present a 78-year-old man with an aortic pseudoaneurysm resulting from a simple vertebral compression fracture, which was conservatively managed. He was diagnosed with a compression fracture from a minor fall 10 days previously, and fortuitously he visited the hospital after which follow-up computed tomography (CT) for previous multiple aortic surgeries was performed. The enhanced CT revealed a pseudoaneurysm on the abdominal aorta, which was bleeding from a pinhole perforation. He was conservatively treated and follow-up CT 9 months later revealed that the pseudoaneurysm had disappeared.
- 1 January 2016
- Published by The Editorial Committee of Annals of Vascular Diseases in Annals of Vascular Diseases
- Vol. 9 (4) , 349-351
Aortic Pseudoaneurysm due to Simple Vertebral Compression Fracture Treated with Conservative Management
Blunt aortic injures are rarely associated with minimal trauma. We present a 78-year-old man with an aortic pseudoaneurysm resulting from a simple vertebral compression fracture, which was conservatively managed. He was diagnosed with a compression fracture from a minor fall 10 days previously, and fortuitously he visited the hospital after which follow-up computed tomography (CT) for previous multiple aortic surgeries was performed. The enhanced CT revealed a pseudoaneurysm on the abdominal aorta, which was bleeding from a pinhole perforation. He was conservatively treated and follow-up CT 9 months later revealed that the pseudoaneurysm had disappeared.
- Open Access
- 1 January 2015
- Published by The Editorial Committee of Annals of Vascular Diseases in Annals of Vascular Diseases
- Vol. 8 (1) , 43-45
Two Dehiscences of the Aortic Valve Commissure and Cusp with Progressive Acute Aortic Regurgitation
A 54-year-old female with acute heart failure due to aortic regurgitation (AR) was admitted to our hospital. Following admission, her condition worsened progressively; thus, surgery was performed prematurely. During surgery, two dehiscences were visualized in the aortic valve commissure between the right and left cusps and the upper part of the left coronary artery ostium. However we scheduled aortic valve replacement (AVR) at first, we made the shift to perform the aortic root replacement for reinforcement of the aortic wall around the left coronary artery ostium. We describe a rare case of two dehiscences at the aortic root, which is the first report.
- 1 January 2015
- Published by The Editorial Committee of Annals of Vascular Diseases in Annals of Vascular Diseases
- Vol. 8 (1) , 43-45
Open AccessTwo Dehiscences of the Aortic Valve Commissure and Cusp with Progressive Acute Aortic Regurgitation
A 54-year-old female with acute heart failure due to aortic regurgitation (AR) was admitted to our hospital. Following admission, her condition worsened progressively; thus, surgery was performed prematurely. During surgery, two dehiscences were visualized in the aortic valve commissure between the right and left cusps and the upper part of the left coronary artery ostium. However we scheduled aortic valve replacement (AVR) at first, we made the shift to perform the aortic root replacement for reinforcement of the aortic wall around the left coronary artery ostium. We describe a rare case of two dehiscences at the aortic root, which is the first report.