    Balancing Radiation Dose Reduction and Image Quality in Chest Computed Tomography using Silicon Rubber-barium Sulfate Composite Shield

    by Mohammad Keshtkar, Saeedeh Yazdanifar

    Background: During chest CT examinations, the breasts are exposed to a significant amount of radiation, increasing the risk of radiation-induced cancers. The objective of this study is to develop and evaluate a novel silicon rubber-barium sulfate (BaSO4) composite breast shield for reducing radiation dose in chest computed tomography (CT) examinations while minimizing impact on image quality. Methods: Four breast shields were fabricated: one with 10% bismuth and three with 10%, 15%, and 20% BaSO4. Dose reduction was assessed using a thorax phantom and ionization chamber. Image quality effects were evaluated in the thorax phantom by measuring noise and CT number changes. The 10% barium shield was further tested on 22 patients undergoing chest CT. Results: The 10%, 15%, and 20% barium shields reduced breast dose by 36.8%, 38.6%, and 45.6%, respectively, while the 10% bismuth shield achieved a 63.1% reduction. However, the 10% barium shield had minimal impact on image quality, increasing lung noise by only 0.3 Hounsfield units (HU) and shifting CT numbers by 4.7 HU. In patient studies, 81.8% of scans showed no artifacts, with 18.2% showing slight artifacts. Conclusion: The 10% BaSO4 shield effectively reduced breast dose while maintaining image quality, presenting a viable alternative to bismuth shielding for radiation protection in chest CT examinations.


  • Open Access

    Evaluation of barium sulfate-copper breast radiation shield for use in thoracic computed tomography examinations

    by F. Poursoltani, M. Behmadi, M. Keshtkar, M. Ghorbani, F. Paknazar, P. Hejazi

    Introduction: In thoracic computed tomography (CT) examinations, patients’ breasts are exposed to high radiation doses, necessitating the reduction of received dose by a radiation shield. The aim of this study is to evaluate the efficiency of a new composition of barium sulfate-copper shield with minimal impact on image quality. Materials and methods: Different breast shields were manufactured using varying weight percentages of copper and BaSO4. Thermoluminescent dosimeters (TLDs) and thorax phantoms were employed to assess the radiation shielding effectiveness. Image quality, in terms of noise and CT number accuracy, was quantitatively evaluated on a CT dose Index phantom (CTDI). Additionally, a controlled trial involving with 30 female participants was conducted to further assess CT image quality and select the best breast radiation shield. Results: The results indicated that the different shield compositions reduced the surface dose by 14.17–51.69%. The shield with a composition of 90% Cu–10% BaSO4 and 50% Cu–50% BaSO4 had the lowest noise, while the 100% bismuth shield had the highest noise. Importantly, the 50% Cu–50% BaSO4 shield did not cause artifacts in the thoracic CT images. Conclusion: By using the 50% Cu–50% BaSO4 shield, a significant dose reduction was achieved while maintaining appropriate image quality, making it suitable for clinical applications.


  • Open Access

    Low cancer risk by implementing low-dose chest computed tomography protocol during Covid-19 outbreak

    by F. Rasoulinejad, M. Keshtkar

    Background: The aim of this study was to evaluate the radiation dose effect of a low-dose chest computed tomography (CT) protocol implemented in our hospital during the outbreak of Coronavirus disease 2019 (COVID-19) by estimating lifetime attributable risk (LAR). Materials and Methods: A total of 583 patients were randomly included in this ...

  • Open Access

    Paediatric cancer risks associated with chest computed tomography (CT) scans: comparison of routine chest and COVID-19 diagnosis CT protocols

    by Mohammad Keshtkar

    The aim of this study is to compare the radiation dose and cancer incidence risk associated with two chest Computed Tomography (CT) protocols: routine chest CT (RC-CT) and COVID-19 Diagnosis CT protocol (CD-CT). The study included 254 pediatric patients divided into three age groups: G1 (vol), dose length product (DLP), size specific dose estimate (SSDE), organ doses, and cancer incidence risk were calculated for the two protocols. Organ doses (mSv) and effective dose (mSv) were estimated using the National Cancer Institute dosimetry system for CT (NCICT) software. Estimation of cancer incidence risks were conducted according to the Biological Effects of Ionizing Radiation (BEIR) VII report. The oldest group (G3) in two protocols exhibited the greatest values for CTDIvol, DLP, effective dose and SSDE. The results showed that CD-CT protocol resulted in statistically significant (p < 0.05) lower organ doses and cancer incidence risk. The cancer incidence risk for both protocols did not exceed the reference levels reported in literature surveys on pediatric CT chest radiation dose for all age groups. It can be concluded that the choice of CT protocol can significantly impact the radiation dose received by pediatric patients during CT imaging, highlighting the importance of carefully selecting the appropriate protocol to minimize radiation exposure.

  • Assessment of the effectiveness of Saba shielding with the composition of Cu–Bi in neck CT imaging: a phantom and patient study

    by Mohammad Keshtkar, Mohammad Amin Mosleh-Shirazi, Valiallah Saba

    The use of computed tomography (CT) is a very well-established medical diagnostic imaging modality, however, the high radiation dose due to this imaging method is a major concern. Therefore, dose reduction methods are necessary, especially for superficial radiosensitive organs like the thyroid. The aim of this study is to construct and assess a CT shield with composition of 90% Cu and 10% Bi (Saba shield) with regard to dose reduction and image quality. The efficiency of the constructed shields for dose reduction was assessed by measuring entrance skin dose (ESD), using thermoluminescence dosimeters placed on an anthropomorphic phantom. Image quality was assessed quantitatively based on image noise and CT number accuracy by drawing regions of interest on CT images of the anthropomorphic phantom. Image quality was further investigated qualitatively in a patient study. Application of the Saba shield and 100% Bi shield with the thickness of one thickness (1T) reduced ESD by 50.2% and 51.7%, respectively, and using a three-fold thickness reduced ESD by 64.6% and 65.1%, respectively. Saba shield with thickness of 1T had no significant change in image noise in the anterior part, and image noise and mean CT number in the posterior part (P > 0.05). The statistical analysis performed did not find any meaningful difference between the study and control groups in image quality assessment of the patient study (P > 0.05). The 1T Saba shield reduced thyroid dose efficiently during neck CT imaging without causing unwanted effects on image quality.


  • EYE RADIATION DOSE SAVING IN HEAD CT EXAMINATIONS USING COPPER-BISMUTH RADIATION SHIELD

    by Mohammad Keshtkar, Basir Blouri, Alireza Mahmoudabadi, Ali Alami

    The aim of the present study is to fabricate a new shield with an optimal combination of copper and bismuth to protect the eyes in the head computed tomography (CT) examinations without compromising image quality. Radiation shields with different compositions were constructed. Computed Tomography Dose Index phantom was used to evaluate the effectiveness of shields in dose reduction and their impact on image quality quantitatively. The shield that caused the least noise in the phantom study was selected for human study. The 10%Bi-90%Cu shield had the least effect on increasing the image noise, and also no remarkable artifact was seen in the CT image of the phantom. The patient study showed that only in 25% of the study group the artifact was observed so that it did not distort the interpretation of the image. It can be concluded that the 10%Bi-90%Cu shield is flexible and durable and would be safely used in the clinic to reduce the eye radiation dose in head CT imaging without compromising image quality.


  • Open Access

    Modified Bismuth Nanoparticles: A New Targeted Nanoprobe for Computed Tomography Imaging of Cancer

    by Milad Mohammadi, Sara Khademi, Yazdan Choghazardi, Rasoul Irajirad, Mohammad Keshtkar, Alireza Montazerabadi

    Objective: Recently, development of multifunctional contrast agent for effective targeted molecular computed tomography (CT) imaging of cancer cells stays a major problem. In this study, we explain the ability of Triptorelin peptide-targeted multifunctional bismuth nanoparticles (Bi2S3@ BSA-Triptorelin NPs) for molecular CT imaging. Materials and Methods: In this experimental study, the formed nanocomplex of Bi2S3@ BSA-Triptorelin NPs was characterized using different methods. The MTT cytotoxicity test was performed to determine the appropriate concentration of nanoparticles in the MCF-7 cells. The X-ray attenuation intensity and Contrast to Noise Ratio (CNR) of targeted and non-targeted nanoparticles were measured at the concentrations of 25, 50, and 75 mu g/ml and X-ray tube voltages of 90, 120 and 140 kVp. Results: We showed that the formed Bi2S3@ BSA-Triptorelin NPs with a Bi core size of approximately -8.6 nm are nontoxic in a given concentration (0-200 mu g/ml). At 90, 120, and 140 tube potentials (kVp), the X-ray attenuation of targeted cells were 1.35, 1.36, and 1.33-times, respectively, more than non-targeted MCF-7cells at the concentration of 75 mu g/ml. The CNR values at 90, 120, and 140 kVp tube potentials were 171.5, 153.8 and 146.3 c/sigma, respectively. Conclusion: These findings propose that the diagnostic nanocomplex of Bi2S3@ BSA-Triptorelin NPs can be applied as a good contrast medium for molecular CT techniques.


  • Open Access

    Common and Uncommon Imaging Appearances of COVID-19 Pneumonia in Young and Middle-Aged Group and Elderly Group

    by Alireza Mahmoudabadi, Hamed Masoumi, Mohammad Keshtkar, Arash Azhideh, Hamidreza Haghighatkhah

    Purpose: In this study, we retrospectively evaluated chest Computed Tomography (CT) imaging manifestations of the patients with Coronavirus Disease 2019 (COVID-19) to simplify prompt early diagnosis of disease and speed up needed actions for infected patients. Materials and Methods: Totally, 75 patients who laboratory confirmed COVID-19 pneumonia were enrolled in this study. CT images, demographic and some clinical data of all patients were collected and analyzed retrospectively. Furthermore, for comparison, the patients were divided into two groups as follows: the young and middle-aged group (< 60 years old) and the elderly group (≥ 60 years old). Results: Based on the evaluation of CT images, 33 patients (44%) showed Ground-Glass Opacity (GGO), 15 patients (20%) showed consolidation, 24 patients (32%) showed mixed GGO and consolidation, 2 patients (2.6%) had bronchial wall thickening, 10 patients (13.3%) had a crazy paving sign, 35 patients (46.6%) had air bronchogram and, 7 patients (9.3%) had cavitation and 2 patients (2.6%) had a tree in the bud. CT images of 3 patients (4%) were normal. In terms of out of lung changes, lymphadenopathy was observed in one patient (1.3%), pleural effusion in 12 patients (16%), and pericardial effusion in 2 patients (2.6%). Lesions were found predominantly in the peripheral (57.3%) and the lower lung region (60%). Conclusion: CT images of the COVID-19 patients showed various aspects, mainly GGO, consolidation, mixed GGO and consolidation, and air bronchogram. Lesion distribution was predominantly in lower lung region, bilateral and peripheral. Pleural effusion and multiple lobe involvement were significantly higher in the elderly group than that of the young and middle-aged group.


  • Assessment of some factors of cellular and humoral immunity in radiology workers

    by Saadat Ebrahimiyan, Alireza Montazerabadi, Hamed Masoumi, Mohammad Keshtkar

    Radiation workers in medical diagnostic departments are occupationally exposed to long-term low-dose ionizing radiation, which may cause radiation-induced side effects. This study investigated subtypes of peripheral blood lymphocytes and immunoglobulin levels in workers who were occupationally exposed to X-ray radiation at the Department of Radiology. Seventeen radiology workers received low levels of ionizing radiation as the study group and 18 individuals who were not exposed to radiation were included as the control group. The percentage of lymphocyte subtypes (CD4+, CD8+ and CD4+/CD8+) and serum levels of immunoglobulins (IgA, IgG and IgM) were measured using peripheral blood samples. Considering all lymphocyte subtypes and serum levels of IgA, IgG and IgM, there was no significant difference between the study and control groups (P > 0.05). There were no significant differences in all mentioned parameters regarding gender (P > 0.05). For the length of employment period, there was a significant difference concerning CD4+/CD8+ (P < 0.05). The findings showed that exposure to low levels of ionizing radiation does not affect the immune system of workers in diagnostic radiology dose level. Because of relatively small samples of workers, it is suggested that these factors be investigated on larger samples of radiology workers.


  • Open Access

    Synthesis and Application of Fe3O4@Au Composite Nanoparticles as Magnetic Resonance/Computed Tomography Dual-Modality Contrast Agent

    by Mohammad Keshtkar, Daryoush Shahbazi-Gahrouei, Alireza Mahmoudabadi

    Background: None of the molecular imaging modalities can produce imaging with both anatomical and functional information. In recent years, to overcome these limitations multimodality molecular imaging or combination of two imaging modalities can provide anatomical and pathological information. Methods: Magnetic iron oxide nanoparticles were prepared by co-precipitation method and then were coated with silica according to Stober method. Consequently, silica-coated nanoparticles were amino-functionalized. Finally, gold nanoparticles assembled onto the surfaces of the previous product. Cytotoxicity effects of prepared Fe3O4@Au nanoparticles were evaluated by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay on human hepatocellular carcinoma cells. Their ability as a dual-mode contrast agent was investigated by magnetic resonance (MR) and computed tomography (CT) imaging. Results: Fe3O4@Au nanoparticles were spherical undersize of 75 nm. X-ray diffraction analysis confirmed the formation of Fe3O4@Au nanoparticles. The magnetometry result confirmed the superparamagnetism property of prepared nanoparticles, and the saturation magnetization (Ms) was found to be 33 emu/g. Fe3O4@Au nanoparticles showed good cytocompatibility up to 60 μg/mL. The results showed that the Fe3O4@Au nanoparticles have good r2 relaxivity (135.26 mM−1s−1) and good X-ray attenuation property. Conclusion: These findings represent that prepared Fe3O4@Au nanoparticles in an easy and relatively low-cost manner have promising potential as a novel contrast agent for dual-modality of MR/CT imaging.