HeaYeon Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
HeaYeon Lee has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
JuKyung Lee
Department of Mechanical and Industrial Engineering, College of Engineering, Northeastern University, Boston, USA
3 shared publications- Hak Soo Choi
Bioengineering and Nanomedicine Program, ADA Forsyth Institute, 100 Chestnut St, Somerville, MA 02143, USA; School of Materials Science, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi 923-1292, Ishikawa, Japan
2 shared publications Hobin Jeong
Department of Mechanical and Industrial Engineering College of Engineering Northeastern University Boston MA 02115 USA
2 shared publicationsJonghan Kim
Department of Pharmaceutical Sciences, Northeastern University, Boston, USA
2 shared publicationsAhmed Busnaina
Northeastern University
1 shared publication- Alessandro Polini
CNR NANOTEC - Institute of Nanotechnology, Campus Ecotekne, via Monteroni, Lecce, 73100, Italy
1 shared publication
Latest Publications
- Open Access
- 8 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-8
Single Microfluidic Electrochemical Sensor System for Simultaneous Multi-Pulmonary Hypertension Biomarker Analyses
Miniaturized microfluidic biosensors have recently been advanced for portable point-of-care diagnostics by integrating lab-on-a-chip technology and electrochemical analysis. However, the design of a small, integrated, and reliable biosensor for multiple and simultaneous electrochemical analyses in a single device remains a challenge. Here, we present a simultaneous microfluidic electrochemical biosensing system to detect multiple biomarkers of pulmonary hypertension diseases in a single device. The miniaturized biosensor, which is composed of five chambers, is precisely and individually controlled using in-house-built pneumatic microvalves to manipulate the flow pathway. Each chamber is connected to an electrochemical sensor designed to detect four different biomarkers plus a reference control. Our design allows for loading of multiple reagents for simultaneous analyses. On the basis of the developed microfluidic electrochemical sensor system, we successfully detected four well-defined pulmonary hypertension-associated biomarkers, namely, fibrinogen, adiponectin, low-density lipoprotein, and 8-isoprostane. This novel approach offers a new platform for a rapid, miniaturized, and sensitive diagnostic sensor in a single device for various human diseases.
- 8 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-8
Open AccessSingle Microfluidic Electrochemical Sensor System for Simultaneous Multi-Pulmonary Hypertension Biomarker Analyses
Miniaturized microfluidic biosensors have recently been advanced for portable point-of-care diagnostics by integrating lab-on-a-chip technology and electrochemical analysis. However, the design of a small, integrated, and reliable biosensor for multiple and simultaneous electrochemical analyses in a single device remains a challenge. Here, we present a simultaneous microfluidic electrochemical biosensing system to detect multiple biomarkers of pulmonary hypertension diseases in a single device. The miniaturized biosensor, which is composed of five chambers, is precisely and individually controlled using in-house-built pneumatic microvalves to manipulate the flow pathway. Each chamber is connected to an electrochemical sensor designed to detect four different biomarkers plus a reference control. Our design allows for loading of multiple reagents for simultaneous analyses. On the basis of the developed microfluidic electrochemical sensor system, we successfully detected four well-defined pulmonary hypertension-associated biomarkers, namely, fibrinogen, adiponectin, low-density lipoprotein, and 8-isoprostane. This novel approach offers a new platform for a rapid, miniaturized, and sensitive diagnostic sensor in a single device for various human diseases.
- 21 June 2017
- Published by Wiley in Advanced Healthcare Materials
- Vol. 6 (17)
Nonmediated, Label‐Free Based Detection of Cardiovascular Biomarker in a Biological Sample
Direct electrochemical (EC) monitoring in a cell culture medium without electron transporter as called mediator is attractive topic in vitro organoid based on chip with frequently and long‐time monitoring since it can avoid to its disadvantage as stability, toxicity. Here, direct monitoring with nonmediator is demonstrated based on impedance spectroscopy under the culture medium in order to overcome the limitation of mediator. The applicability of EC monitoring is shown by detecting alpha‐1‐anti trypsin (A1AT) which is known as biomarkers for cardiac damage and is widely chosen in organoid cardiac cell‐based chip. The validity of presented EC monitoring is proved by observing signal processing and transduction in medium, mediator, medium–mediator complex. After the observation of electron behavior, A1AT as target analyte is immobilized on the electrode and detected using antibody–antigen interaction. As a result, the result indicates limit of detection is 10 ng mL−1 and linearity for the 10–1000 ng mL−1 range, with a sensitivity of 3980 nF (log [g mL])−1 retaining specificity. This EC monitoring is based on label‐free and reagentless detection, will pave the way to use for continuous and simple monitoring of in vitro organoid platform.
- 21 June 2017
- Published by Wiley in Advanced Healthcare Materials
- Vol. 6 (17)
Nonmediated, Label‐Free Based Detection of Cardiovascular Biomarker in a Biological Sample
Direct electrochemical (EC) monitoring in a cell culture medium without electron transporter as called mediator is attractive topic in vitro organoid based on chip with frequently and long‐time monitoring since it can avoid to its disadvantage as stability, toxicity. Here, direct monitoring with nonmediator is demonstrated based on impedance spectroscopy under the culture medium in order to overcome the limitation of mediator. The applicability of EC monitoring is shown by detecting alpha‐1‐anti trypsin (A1AT) which is known as biomarkers for cardiac damage and is widely chosen in organoid cardiac cell‐based chip. The validity of presented EC monitoring is proved by observing signal processing and transduction in medium, mediator, medium–mediator complex. After the observation of electron behavior, A1AT as target analyte is immobilized on the electrode and detected using antibody–antigen interaction. As a result, the result indicates limit of detection is 10 ng mL−1 and linearity for the 10–1000 ng mL−1 range, with a sensitivity of 3980 nF (log [g mL])−1 retaining specificity. This EC monitoring is based on label‐free and reagentless detection, will pave the way to use for continuous and simple monitoring of in vitro organoid platform.
- 6 December 2015
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 67 (11) , 1957-1960
AFM detection of an Alzheimer marker: Different stages of amyloid beta peptide on a mica substrate
- 6 December 2015
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 67 (11) , 1957-1960
AFM detection of an Alzheimer marker: Different stages of amyloid beta peptide on a mica substrate
- Open Access
- 10 May 2012
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (12) , 2860-2865
Characterization of the GM1 pentasaccharide–Vibrio cholera toxin interaction using a carbohydrate-based electrochemical system
Antibody- or DNA-based electrochemical systems have been developed widely for several decades, while carbohydrate-based electrochemical systems have been rarely reported. Herein, we used an electrochemical detection system to understand the molecular relationships in carbohydrate–protein interactions that can provide useful information about biological processes in living organisms. This system was also helpful for the development of potent biomedical agents. Electrochemical detection was achieved through the observation of electrochemical response changes of ferrocyanide solution that resulted from the interaction of carbohydrate and protein using a modified GM1 pentasaccharide containing an anchoring thiol group that was directly immobilized on a gold electrode. As the concentration of the GM1 pentasaccharide increased, the current decreased gradually and saturated after 2 nM. We also found that the drop in current depended on the size of the carbohydrate (larger size of the carbohydrate denoted a higher slope of the current reduction), indicating that the current could be modulated by the molecular size of the carbohydrate as well as its concentration. This system was able to detect very low concentrations of carbohydrate (down to 20 fM), which highlighted the advantage of the electrochemical system. Interestingly, we found that a potential shift at the maximum current occurred upon interaction with cholera toxin proteins. By comparing results for different sizes of GM1 analogues, we surmise that the potential shift is closely associated with the specificity for the carbohydrate–protein interaction. Collectively, a carbohydrate-based electrochemical system can be leveraged for the facile and rapid analysis of carbohydrate–protein interactions.
- 10 May 2012
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (12) , 2860-2865
Open AccessCharacterization of the GM1 pentasaccharide–Vibrio cholera toxin interaction using a carbohydrate-based electrochemical system
Antibody- or DNA-based electrochemical systems have been developed widely for several decades, while carbohydrate-based electrochemical systems have been rarely reported. Herein, we used an electrochemical detection system to understand the molecular relationships in carbohydrate–protein interactions that can provide useful information about biological processes in living organisms. This system was also helpful for the development of potent biomedical agents. Electrochemical detection was achieved through the observation of electrochemical response changes of ferrocyanide solution that resulted from the interaction of carbohydrate and protein using a modified GM1 pentasaccharide containing an anchoring thiol group that was directly immobilized on a gold electrode. As the concentration of the GM1 pentasaccharide increased, the current decreased gradually and saturated after 2 nM. We also found that the drop in current depended on the size of the carbohydrate (larger size of the carbohydrate denoted a higher slope of the current reduction), indicating that the current could be modulated by the molecular size of the carbohydrate as well as its concentration. This system was able to detect very low concentrations of carbohydrate (down to 20 fM), which highlighted the advantage of the electrochemical system. Interestingly, we found that a potential shift at the maximum current occurred upon interaction with cholera toxin proteins. By comparing results for different sizes of GM1 analogues, we surmise that the potential shift is closely associated with the specificity for the carbohydrate–protein interaction. Collectively, a carbohydrate-based electrochemical system can be leveraged for the facile and rapid analysis of carbohydrate–protein interactions.