Peter Carl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peter Carl has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Rudolf J. Schneider
BAM Federal Institute for Materials Research and Testing, 12205 Berlin, Germany
7 shared publications Dominik Sarma
Department of Analytical Chemistry; Reference Materials , Bundesanstalt für Materialforschung und -prüfung (BAM) , Richard-Willstätter-Strasse 11 , D-12489 Berlin , Germany
3 shared publications- Knut Rurack
Chemical and Optical Sensing Division, Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, Berlin 12489, Germany
3 shared publications Estela Climent
2 shared publications- Inês I. Ramos
Laboratório de Química Orgânica e Farmacêutica, Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, Rua Jorge Viterbo Ferreira nº 228, 4050-313 Porto, Portugal
2 shared publications - Marcela Alves Segundo
LAQV, REQUIMTE, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, Rua de Jorge Viterbo Ferreira 228, 4050-313 Porto, Portugal
2 shared publications
Latest Publications
- Open Access
- 4 November 2026
- Published by Elsevier in Analytica Chimica Acta
High-throughput multi-element analysis: a wash-free spatially segregated multiplex immunoassay for heavy metals in water
- 4 November 2026
- Published by Elsevier in Analytica Chimica Acta
Open AccessHigh-throughput multi-element analysis: a wash-free spatially segregated multiplex immunoassay for heavy metals in water
- Open Access
- 8 June 2021
- Published by Wiley in ChemElectroChem
- Vol. 8 (13) , 2597-2606
Electrochemical Immunomagnetic Ochratoxin A Sensing: Steps Forward in the Application of 3,3’,5,5’‐Tetramethylbenzidine in Amperometric Assays
Electrochemical methods offer great promise in meeting the demand for user‐friendly on‐site devices for monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme‐linked immunosorbent assays, with photometric detection of 3,3’,5,5’‐tetramethylbenzidine (TMB), form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detection step, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphone‐based, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis for sensing of further analytes.
- 8 June 2021
- Published by Wiley in ChemElectroChem
- Vol. 8 (13) , 2597-2606
Open AccessElectrochemical Immunomagnetic Ochratoxin A Sensing: Steps Forward in the Application of 3,3’,5,5’‐Tetramethylbenzidine in Amperometric Assays
Electrochemical methods offer great promise in meeting the demand for user‐friendly on‐site devices for monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme‐linked immunosorbent assays, with photometric detection of 3,3’,5,5’‐tetramethylbenzidine (TMB), form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detection step, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphone‐based, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis for sensing of further analytes.
- 1 October 2019
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1076, 91-99
Automated lab-on-valve sequential injection ELISA for determination of carbamazepine
- 1 October 2019
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1076, 91-99
Automated lab-on-valve sequential injection ELISA for determination of carbamazepine
- 18 September 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (20) , 12988-12996
Wash-Free Multiplexed Mix-and-Read Suspension Array Fluorescence Immunoassay for Anthropogenic Markers in Wastewater
Pharmaceuticals, certain food ingredients and mammalian endogenous metabolic products in wastewater are mostly of human origin, they are anthropogenic markers. Proper knowledge on their levels in wastewater helps to track sources of pollutants in natural waters and allows to calculate removal efficiencies in wastewater treatment plants. Here, we describe the development and application of an indirect competitive, multiplexing suspension array fluorescence im-munoassay (SAFIA) for the detection of carbamazepine (CBZ), diclofenac (DCF), caffeine (CAF), and isolithocholic acid (ILA) in wastewater, covering those classes of anthropogenic markers. The assay consists of haptens covalently conjugated to fluorescence encoded polystyrene core/silica shell microparticles to create a site for competitive binding of the antibodies (Abs). Bound Abs are then stained with fluorophore-labeled Abs. Encoding and signaling fluores-cence of the particles are determined by an automated flow cytometer. For compatibility of the immunoassay with the 96-well microtiter plate format, a stop reagent, containing formaldehyde, is used, enabling a wash-free procedure while decreasing time-to-result. Detection limits of 140 ± 40 ng/L for CBZ, 180 ± 110 ng/L for CAF, 4 ± 3 ng/L for DCF and 310 ± 70 ng/L for ILA are achieved, which meet the sensitivity criteria of wastewater analysis. We demonstrate the applica-bility of SAFIA to real wastewater samples from three different wastewater treatment plants, finding the results in good agreement with LC-MS/MS. Moreover, the accuracy in general exceeded that from classical ELISAs. We therefore propose SAFIA as a quick and reliable approach for wastewater analysis meeting the requirements for process analytical technology.
- 18 September 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (20) , 12988-12996
Wash-Free Multiplexed Mix-and-Read Suspension Array Fluorescence Immunoassay for Anthropogenic Markers in Wastewater
Pharmaceuticals, certain food ingredients and mammalian endogenous metabolic products in wastewater are mostly of human origin, they are anthropogenic markers. Proper knowledge on their levels in wastewater helps to track sources of pollutants in natural waters and allows to calculate removal efficiencies in wastewater treatment plants. Here, we describe the development and application of an indirect competitive, multiplexing suspension array fluorescence im-munoassay (SAFIA) for the detection of carbamazepine (CBZ), diclofenac (DCF), caffeine (CAF), and isolithocholic acid (ILA) in wastewater, covering those classes of anthropogenic markers. The assay consists of haptens covalently conjugated to fluorescence encoded polystyrene core/silica shell microparticles to create a site for competitive binding of the antibodies (Abs). Bound Abs are then stained with fluorophore-labeled Abs. Encoding and signaling fluores-cence of the particles are determined by an automated flow cytometer. For compatibility of the immunoassay with the 96-well microtiter plate format, a stop reagent, containing formaldehyde, is used, enabling a wash-free procedure while decreasing time-to-result. Detection limits of 140 ± 40 ng/L for CBZ, 180 ± 110 ng/L for CAF, 4 ± 3 ng/L for DCF and 310 ± 70 ng/L for ILA are achieved, which meet the sensitivity criteria of wastewater analysis. We demonstrate the applica-bility of SAFIA to real wastewater samples from three different wastewater treatment plants, finding the results in good agreement with LC-MS/MS. Moreover, the accuracy in general exceeded that from classical ELISAs. We therefore propose SAFIA as a quick and reliable approach for wastewater analysis meeting the requirements for process analytical technology.
- Open Access
- 26 June 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (6) , e0218686
Antibody conjugation to carboxyl-modified microspheres through N-hydroxysuccinimide chemistry for automated immunoassay applications: A general procedure
Immunochemical techniques are the workhorse for sample enrichment and detection of a large variety of analytes. In contrast to classical microtiter plate-based assays, microparticles are a next generation solid support, as they promote automation of immunoassays using flow-based techniques. Antibody immobilization is a crucial step, as these reagents are expensive, and inefficient coupling can result in low sensitivities. This paper proposes a general procedure for efficient immobilization of antibodies onto TentaGel particles, via N-hydroxysuccinimide chemistry. The goal was the preparation of solid supports with optimum immunorecognition, while increasing the sustainability of the process. The influence of buffer composition, activation and coupling time, as well as the amount of antibody on the immobilization efficiency was investigated, resorting to fluorophore-labeled proteins and fluorescence imaging. Buffer pH and activation time are the most important parameters for efficient coupling. It is demonstrated, that the hydrolysis of N-hydroxysuccinimide esters occurs at similar rates as in solution, limiting the utilizable time for coupling. Finally, applicability of the generated material for automated affinity extraction is demonstrated on the mesofluidic platform lab-on-valve.
- 26 June 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (6) , e0218686
Open AccessAntibody conjugation to carboxyl-modified microspheres through N-hydroxysuccinimide chemistry for automated immunoassay applications: A general procedure
Immunochemical techniques are the workhorse for sample enrichment and detection of a large variety of analytes. In contrast to classical microtiter plate-based assays, microparticles are a next generation solid support, as they promote automation of immunoassays using flow-based techniques. Antibody immobilization is a crucial step, as these reagents are expensive, and inefficient coupling can result in low sensitivities. This paper proposes a general procedure for efficient immobilization of antibodies onto TentaGel particles, via N-hydroxysuccinimide chemistry. The goal was the preparation of solid supports with optimum immunorecognition, while increasing the sustainability of the process. The influence of buffer composition, activation and coupling time, as well as the amount of antibody on the immobilization efficiency was investigated, resorting to fluorophore-labeled proteins and fluorescence imaging. Buffer pH and activation time are the most important parameters for efficient coupling. It is demonstrated, that the hydrolysis of N-hydroxysuccinimide esters occurs at similar rates as in solution, limiting the utilizable time for coupling. Finally, applicability of the generated material for automated affinity extraction is demonstrated on the mesofluidic platform lab-on-valve.
- Open Access
- 5 March 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (11) , 11028
Correction to “Multifunctional Polystyrene Core/Silica Shell Microparticles with Antifouling Properties for Bead-Based Multiplexed and Quantitative Analysis”
- 5 March 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (11) , 11028
Open AccessCorrection to “Multifunctional Polystyrene Core/Silica Shell Microparticles with Antifouling Properties for Bead-Based Multiplexed and Quantitative Analysis”
- Open Access
- 3 December 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (1) , 1321-1334
Multifunctional Polystyrene Core/Silica Shell Microparticles with Antifouling Properties for Bead-Based Multiplexed and Quantitative Analysis
Commercial bead-based assays are commonly built upon polystyrene particles. The polymeric carrier can be encoded with organic dyes and has ideal material properties for cytometric applications such as low density and high refractive index. However, functional groups are conventionally integrated during polymerization and subsequent modification is limited to the reactivity of those groups that have been introduced during the bead preparation step. Additionally, the hydrophobicity of polystyrene as the core material leads to many hydrophobic areas still being present on the beads’ surfaces even after functionalization, rendering the particles prone to non-specific adsorption during an application. The latter calls for several washing steps and the use of additives in (bio)analytical assays. In this contribution, we show how these limitations can be overcome by using monodisperse polystyrene (PS) core/silica (SiO2) shell particles (SiO2@PS). Two different hydrophobic BODIPY (boron–dipyrromethene) dyes were encapsulated inside a poly(vinylpyrrolidone) (PVP) -stabilized polystyrene core in different concentrations to create 5-plex arrays in two separate detection channels of a cytometer. A subsequent modification of the silica shell with an equimolar APTES/PEGS (aminopropyltriethoxysilane/polyethylene glycol silane) blend added multifunctional properties to the hybrid core/shell microparticles in a single step: APTES provides amino groups for the attachment of a caffeine derivative (as a hapten) to create antigen-coupled microspheres; the PEG moiety effectively suppresses non-specific binding of antibodies, endowing the surface with antifouling properties. The particles were applied in a competitive fluorescence immunoassay in suspension and a highly selective wash-free assay for the detection of caffeine in beverages was developed as a proof of concept.
- 3 December 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (1) , 1321-1334
Open AccessMultifunctional Polystyrene Core/Silica Shell Microparticles with Antifouling Properties for Bead-Based Multiplexed and Quantitative Analysis
Commercial bead-based assays are commonly built upon polystyrene particles. The polymeric carrier can be encoded with organic dyes and has ideal material properties for cytometric applications such as low density and high refractive index. However, functional groups are conventionally integrated during polymerization and subsequent modification is limited to the reactivity of those groups that have been introduced during the bead preparation step. Additionally, the hydrophobicity of polystyrene as the core material leads to many hydrophobic areas still being present on the beads’ surfaces even after functionalization, rendering the particles prone to non-specific adsorption during an application. The latter calls for several washing steps and the use of additives in (bio)analytical assays. In this contribution, we show how these limitations can be overcome by using monodisperse polystyrene (PS) core/silica (SiO2) shell particles (SiO2@PS). Two different hydrophobic BODIPY (boron–dipyrromethene) dyes were encapsulated inside a poly(vinylpyrrolidone) (PVP) -stabilized polystyrene core in different concentrations to create 5-plex arrays in two separate detection channels of a cytometer. A subsequent modification of the silica shell with an equimolar APTES/PEGS (aminopropyltriethoxysilane/polyethylene glycol silane) blend added multifunctional properties to the hybrid core/shell microparticles in a single step: APTES provides amino groups for the attachment of a caffeine derivative (as a hapten) to create antigen-coupled microspheres; the PEG moiety effectively suppresses non-specific binding of antibodies, endowing the surface with antifouling properties. The particles were applied in a competitive fluorescence immunoassay in suspension and a highly selective wash-free assay for the detection of caffeine in beverages was developed as a proof of concept.
- 22 March 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (7) , 4007-4012
Hapten-Specific Single-Cell Selection of Hybridoma Clones by Fluorescence-Activated Cell Sorting for the Generation of Monoclonal Antibodies
The conventional hybridoma screening and subcloning process is generally considered to be one of the most critical steps in hapten-specific antibody production. It is time-consuming, monoclonality is not guaranteed, and the number of clones that can be screened is limited. Our approach employs a novel hapten-specific labeling technique of hybridoma cells. This allows for fluorescence-activated cell sorting (FACS) and single-cell deposition and thereby eliminates the above-mentioned problems. A two-step staining approach is used to detect antigen specificity and antibody expression: in order to detect antigen specificity, hybridoma cells are incubated with a hapten–horseradish peroxidase conjugate (hapten–HRP), which is subsequently incubated with a fluorophore-labeled polyclonal anti-peroxidase antibody (anti-HRP–Alexa Fluor 488). To characterize the expression of membrane-bound immunoglobulin G (IgG), a fluorophore-labeled anti-mouse IgG antibody (anti-IgG–Alexa Fluor 647) is used. Hundreds of labeled hybridoma cells producing monoclonal antibodies (mAbs) specific for a hapten were rapidly isolated and deposited from a fusion mixture as single-cell clones via FACS. Enzyme-linked immunosorbent assay (ELISA) measurements of the supernatants of the sorted hybridoma clones revealed that all hapten-specific hybridoma clones secrete antibodies against the target. There are significant improvements using this high-throughput technique for the generation of mAbs including increased yield of antibody-producing hybridoma clones, ensured monoclonality of sorted cells, and reduced development times.
- 22 March 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (7) , 4007-4012
Hapten-Specific Single-Cell Selection of Hybridoma Clones by Fluorescence-Activated Cell Sorting for the Generation of Monoclonal Antibodies
The conventional hybridoma screening and subcloning process is generally considered to be one of the most critical steps in hapten-specific antibody production. It is time-consuming, monoclonality is not guaranteed, and the number of clones that can be screened is limited. Our approach employs a novel hapten-specific labeling technique of hybridoma cells. This allows for fluorescence-activated cell sorting (FACS) and single-cell deposition and thereby eliminates the above-mentioned problems. A two-step staining approach is used to detect antigen specificity and antibody expression: in order to detect antigen specificity, hybridoma cells are incubated with a hapten–horseradish peroxidase conjugate (hapten–HRP), which is subsequently incubated with a fluorophore-labeled polyclonal anti-peroxidase antibody (anti-HRP–Alexa Fluor 488). To characterize the expression of membrane-bound immunoglobulin G (IgG), a fluorophore-labeled anti-mouse IgG antibody (anti-IgG–Alexa Fluor 647) is used. Hundreds of labeled hybridoma cells producing monoclonal antibodies (mAbs) specific for a hapten were rapidly isolated and deposited from a fusion mixture as single-cell clones via FACS. Enzyme-linked immunosorbent assay (ELISA) measurements of the supernatants of the sorted hybridoma clones revealed that all hapten-specific hybridoma clones secrete antibodies against the target. There are significant improvements using this high-throughput technique for the generation of mAbs including increased yield of antibody-producing hybridoma clones, ensured monoclonality of sorted cells, and reduced development times.
- 7 April 2016
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 88 (6) , 756-763
Towards Process Spectroscopy in Complex Fermentation Samples and Mixtures
- 7 April 2016
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 88 (6) , 756-763
Towards Process Spectroscopy in Complex Fermentation Samples and Mixtures
- Open Access
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 120, 501-506
Optimization and Evaluation of a Hapten Microarray Using Chemometric Methods
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 120, 501-506
Open AccessOptimization and Evaluation of a Hapten Microarray Using Chemometric Methods