ALAntonio Mendoza Ladd

Antonio Mendoza Ladd

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Antonio Mendoza Ladd has a total of 122 co-authors. Here are the top co-authors by number of shared publications:

  • Mohammad Bilal

    University of Colorado Anschutz Medical Campus, Colorado, United States

    3 shared publications
  • Alberto Contreras

    From Shrewsbury Internal Medicine, UMass Memorial Health, Shrewsbury, Massachusetts, the Division of Gastroenterology, University of Texas Health Science Center at San Antonio, the Division of Infectious Disease, University of South Florida, Tampa, the Division of Gastroenterology, Texas Tech University Health Sciences Center El Paso, and the Department of Internal Medicine. Division of Gastroenterology, University of New Mexico, Albuquerque

    2 shared publications
  • Alexander Schlachterman

    Division of Gastroenterology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA

    2 shared publications
  • Cesar Garcia

    University Medical Center, El Paso, USA

    2 shared publications
  • Sunil Amin

    Division of Digestive Health and Liver Diseases, Department of Medicine, University of Miami, Miami, FL, USA

    2 shared publications
  • Abdelhai Abdelqader

    Department of Gastroenterology, Robert Wood Johnson University Hospital, New Brunswick, NJ

    1 shared publication

Latest Publications

  • Efficacy of Endoscopic Full Thickness Resection Using the Full-Thickness Resection Device for Submucosal Invasive Colorectal Cancer: The First United States Multicenter Experience

    by Rahul Karna, Syed Kashif Mahmood, Jennifer Phan, Sumant Inamdar, Antonio Mendoza Ladd, Veeral M. Oza, Mohit Girotra, Harshit Khara, Natalie Wilson, Nabeel Azeem, et al.

    Purpose Endoscopic full-thickness resection (EFTR) using full thickness resection device is used for removal of non-lifting or previously manipulated polyps. There is limited data regarding its efficacy for removal of colorectal submucosal invasive cancer (SMIC). Methods We conducted retrospective multicenter study on patients who underwent EFTR using full thickness resection device for suspected or biopsy proven colorectal cancer (CRC). Results Technical success was 100% and R0 resection rate was 85%. Overall, 6/20 were referred for surgery due to high risk features. Curative resection rate was 46.7% (7/15) in T1 CRC. Adverse events included 1 bleeding and 1 perforation, managed endoscopically and 1 bleeding and 2 post-polypectomy syndromes managed conservatively. Conclusions Our series provides the first multicenter experience on EFTR for resection of colorectal SMIC from the United States. Longitudinal data from large scale studies are required to validate our initial experience of EFTR for SMIC.


  • Gastro-Entero-Colic Fistula After Successful EUS Guided Gastroenterostomy

    by Antonio Mendoza Ladd, Michel Ladna, Luke Pecha, Enrique Perez Cuadrado, Kaveh Sharzehi, Meera. Bhardwaj, Samuel Han, Jorge Vargas, Sumant Inamdar, Khanh Do-Cong Pham, et al.

    Background: EUS-guided gastroenterostomy (EUS-GE) is an effective option for the management of gastric outlet obstruction (GOO). Due to the poor prognosis of patients undergoing it, data on its long-term adverse events (AE) is scarce. Herein, we describe a cohort of patients with gastro-entero-colic fistula (GECF) as a late AE of previously successful EUS-GE. Methods: Patients who developed a GECF after EUS-GE from 10 high-volume centers were analyzed. Information collected included demographic characteristics, indications, clinical and technical success rates, stent type and size, fistula characteristics, management, and outcomes. Results: Sixteen cases were identified. The mean interval from index EUS-GE to the diagnosis of GECF was 4 to 8 weeks. The most common cause of GOO was pancreatic adenocarcinoma (PDAC). The transverse colon was the most common site for the GECF (14 patients). A 20×10 mm lumen apposing metal stent (LAMS) was utilized in 10 patients. Endoscopic management with a variety of modalities was successful in 13 cases. Follow-up interval after endoscopic management of the fistula averaged 2 to 4 weeks. At the time of the manuscript elaboration, 10 patients had died, 5 were alive, and 1 was lost to follow-up. Conclusions: This is the first description of a cohort of patients with GECF after EUS-GE. The exact mechanisms leading to GECF in these cases are unknown. Possible explanations include inadvertent colon puncture during the index procedure and/or entrapment of mesocolon. More data is needed to further characterize this AE.


  • Towards automating risk stratification of intraductal papillary mucinous Neoplasms: Artificial intelligence advances beyond human expertise with confocal laser endomicroscopy

    by Somashekar G. Krishna, Ahmed Abdelbaki, Ziwei Li, Stacey Culp, Xinqi Xiong, Bertrand Napoleon, Shaffer Mok, Helga Bertani, Yunlu Feng, Pradermchai Kongkam, et al.


  • Open Access

    Initial experience with transmural use of a new endoscopic ultrasound electric core needle biopsy device: Case series

    by Antonio Mendoza Ladd, Amer Alsamman, Karleen Meiklejohn, Omar Viramontes

    Background and study aims Endoscopic ultrasound-guided biopsy via fine-needle biopsy/fine-needle aspiration (FNB/FNA) is currently the standard method to sample tumors in the mediastinum and abdomen. Although specimens obtained with these needles are acceptable, a histological diagnosis is not always possible. Recently, a new EUS-guided core needle biopsy (EUS-CNB) device became available. Herein, we describe the first experience with its use in a transmural fashion. Patients and methods This was a case series of patients who underwent EUS-CNB at an academic center. All patients provided written informed consent and were observed in the hospital ≥ 48 hours after the procedure. Results A total of 8 patients underwent EUSC-CNB: five in the pancreas, two in the retroperitoneum, and one in the mediastinum. The diagnostic accuracy of EUS-CNB was 100% after one actuation. In four patients, same-session FNB and EUS-CNB were obtained from the same lesion with superior tissue sample in the latter. No adverse events were documented. Conclusions To our knowledge this is the first report on transmural use of EUS-CNB in gastroenterology. Our findings suggest that the device is effective and safe. Larger studies comparing it with FNA/FNB needles will be required to further assess performance and safety.

  • EUS-guided Gastroenterostomy

    by Michel Kahaleh, Amy Tyberg, Sohini Sameera, Avik Sarkar, Haroon M. Shahid, Abdelhai Abdelqader, Mihajlo Gjeorgjievski, Monica Gaidhane, Thiruvengadam Muniraj, Priya A. Jamidar, et al.

    Background: Endoscopic ultrasound (EUS)-guided gastroenterostomy (EUS-GE) is a minimally invasive therapy for patients with gastric outlet obstruction without the risks of surgical bypass and the limited long-term efficacy of enteral self-expanding metal stent placement. However, due to its novelty, there is a lack of significant data comparing long-term outcomes of patients with EUS-GE, based on the underlying disease. In this study, we compare outcomes of EUS-GE on benign versus malignant indications. Methods: Consecutive patients from 12 international, tertiary care centers who underwent EUS-GE over 3 years were extracted in a retrospective registry. Demographic characteristics, procedure-related information and follow-up data was collected. Primary outcome was the rate of adverse events associated with EUS-GE and the comparison of the rate of adverse events in benign versus malignant diseases. Secondary outcomes included technical and clinical success as well as hospitalization admission. Results: A total of 103 patients were included: 72 malignant and 31 benign. The characteristics of the patients undergoing EUS-GE is shown in Table 1. The mean age of the cohort was 68 years and 58 years for malignant and benign etiology. Gender distribution was 57% and 39% being females in malignant and benign etiology group, respectively. Clinical success, technical success, average procedure time, and hospital length of stay were similar in both groups. Patients with benign underlying etiology had significantly higher number of surgically altered midgut anatomy (P=0.0379). Conclusion: EUS-GE is equally efficient regardless of the underlying etiology (malignant vs. benign), and the adverse events both groups were comparable.


  • Prophylactic stenting to decrease the incidence of esophageal strictures after extensive endoscopic submucosal dissection: the first U.S. experience

    by Antonio Mendoza Ladd, Kenneth Park, Mohammad Bilal, Alexander Schlachterman, Sunil Amin, George Obeng, Adnan Khan, Shyam Thakkar


  • Prophylactic stenting as a method to decrease incidence of post ESD strictures in esophagus. A case series

    by A. Mendoza Ladd, K. Park, M. Bilal, A. Schlachterman, A. Khan, S. Amin, G. Obeng, S. Thakkar

    Aims Endoscopic submucosal dissection (ESD) allows curative en bloc resection of large early esophageal neoplasms with low recurrence rates. However, these large resections almost invariably lead to recalcitrant esophageal strictures. Prophylactic use of fully covered metal stents to prevent such strictures has been seldomly used. In this case series we evaluated the effectiveness of such an approach. Methods Data on patients who underwent extensive ESD (>50 % circumference) for a variety of lesions was collected retrospectively. Only patients in whom stent was placed within 24 hrs of the resection, no other stricture preventing measures were used and with follow up endoscopy after ≥3 months of resection were included. Post ESD stricture was defined as a clinically significant one requiring any kind of treatment [1]. Results A total of 8 patients were analyzed. The mean age was 69 years, and 4 were males. All patients except one underwent circumferential resections (mean length 6 cm). Stents were placed immediately after resection except in one case and all of them were anchored using different methods. The mean interval from placement to removal was 35 days. Stricture was avoided in 5 patients (63%). Stent migration ocurred in 2 patients and no serious adverse events were noted. In one case the stent had to be removed 4 days after placement due to severe discomfort ([Table 1]). Conclusions Prophylactic use of fully covered metal stents after extensive ESD seems to be an effective approach at preventing clinically significant strictures. This method should be studied in prospective trials to further assess its effectiveness. Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • A Glasgow-Blatchford Bleeding Score of >2 Is a Poor Predictor of Endoscopic Intervention in Nonvariceal Upper GI Bleeding

    by Kanchana Myneedu, Mahesh Gajendran, Alberto Contreras, Alejandro Robles, Antonio Mendoza Ladd

    Objectives: Recent data show that a Glasgow-Blatchford Bleeding Score (GBS) >2 does not identify patients with upper gastrointestinal (GI) bleeding who benefit from inpatient esophagogastroduodenoscopy (EGD). This study aimed to determine the rate of endoscopic hemostatic interventions (HI) in patients with nonvariceal acute GI bleeding (NVAUGIB) admitted with a GBS >2. Secondary aims...