Christopher Siviy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Christopher Siviy has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Conor James Walsh
Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
11 shared publications - Denise Martineli Rossi
Federal University of Triângulo Mineiro
5 shared publications Ignacio Galiana
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA
5 shared publicationsFausto A. Panizzolo
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA
4 shared publicationsPhilippe Malcolm
Department of Biomechanics and Center for Research in Human Movement Variability, University of Nebraska Omaha, Omaha, NE 68182, USA
4 shared publicationsSangjun Lee
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA; Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02138, USA
4 shared publications
Latest Publications
- Open Access
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 2273-2285
Multi-Modal Sensing for Propulsion Estimation in People Post-Stroke Across Speeds
Gait rehabilitation is critical for regaining locomotor independence after neuromotor injuries like stroke. Rehabilitation literature indicates the need for such therapy to continue beyond the clinic in order to maintain motor function and support recovery. However, implementing community-based rehabilitation requires the ability to monitor gait in the real-world with clinically relevant accuracies. Despite advances in machine learning, achieving this performance with single sensing modalities has been challenging using wearable sensors like inertial measurement units (IMUs) and pressure insoles. Here, we investigate the benefits of multi-modal sensing by integrating IMU and insole data to develop individualized machine learning models in people post-stroke that estimate propulsion, a key biomechanical variable. We show that in the lab, IMU + Insole models improve performance with an average root-mean- squared-error (RMSE) of 0.80 %bodyweight (%BW) across the stance phase. We obtain RMSEs of 0.71 %BW for peak paretic propulsion and 0.19 %BW s for paretic propulsion impulse, which are within corresponding clinical thresholds. We then explore the application of this algorithm to track propulsion changes in the real-world for two participants during variable-speed walking and two participants during active gait interventions, either functional electrical stimulation or exosuit-applied resistance. For these participants, we observe similar changes in measured propulsion in the lab and estimated propulsion out of the lab across speeds and interventions. Overall, this work aims to address the challenges in applying machine learning methods for individuals post-stroke and presents an investigation into the feasibility of developing estimation methods for real-world propulsion estimation during gait rehabilitation.
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 2273-2285
Open AccessMulti-Modal Sensing for Propulsion Estimation in People Post-Stroke Across Speeds
Gait rehabilitation is critical for regaining locomotor independence after neuromotor injuries like stroke. Rehabilitation literature indicates the need for such therapy to continue beyond the clinic in order to maintain motor function and support recovery. However, implementing community-based rehabilitation requires the ability to monitor gait in the real-world with clinically relevant accuracies. Despite advances in machine learning, achieving this performance with single sensing modalities has been challenging using wearable sensors like inertial measurement units (IMUs) and pressure insoles. Here, we investigate the benefits of multi-modal sensing by integrating IMU and insole data to develop individualized machine learning models in people post-stroke that estimate propulsion, a key biomechanical variable. We show that in the lab, IMU + Insole models improve performance with an average root-mean- squared-error (RMSE) of 0.80 %bodyweight (%BW) across the stance phase. We obtain RMSEs of 0.71 %BW for peak paretic propulsion and 0.19 %BW s for paretic propulsion impulse, which are within corresponding clinical thresholds. We then explore the application of this algorithm to track propulsion changes in the real-world for two participants during variable-speed walking and two participants during active gait interventions, either functional electrical stimulation or exosuit-applied resistance. For these participants, we observe similar changes in measured propulsion in the lab and estimated propulsion out of the lab across speeds and interventions. Overall, this work aims to address the challenges in applying machine learning methods for individuals post-stroke and presents an investigation into the feasibility of developing estimation methods for real-world propulsion estimation during gait rehabilitation.
- Top Cited Papers
- 22 December 2022
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (4) , 456-472
Opportunities and challenges in the development of exoskeletons for locomotor assistance
Exoskeletons can augment the performance of unimpaired users and restore movement in individuals with gait impairments. Knowledge of how users interact with wearable devices and of the physiology of locomotion have informed the design of rigid and soft exoskeletons that can specifically target a single joint or a single activity. In this Review, we highlight the main advances of the past two decades in exoskeleton technology and in the development of lower-extremity exoskeletons for locomotor assistance, discuss research needs for such wearable robots and the clinical requirements for exoskeleton-assisted gait rehabilitation, and outline the main clinical challenges and opportunities for exoskeleton technology.
- 22 December 2022
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (4) , 456-472
Top Cited PapersOpportunities and challenges in the development of exoskeletons for locomotor assistance
Exoskeletons can augment the performance of unimpaired users and restore movement in individuals with gait impairments. Knowledge of how users interact with wearable devices and of the physiology of locomotion have informed the design of rigid and soft exoskeletons that can specifically target a single joint or a single activity. In this Review, we highlight the main advances of the past two decades in exoskeleton technology and in the development of lower-extremity exoskeletons for locomotor assistance, discuss research needs for such wearable robots and the clinical requirements for exoskeleton-assisted gait rehabilitation, and outline the main clinical challenges and opportunities for exoskeleton technology.
- Open Access
- 25 March 2021
- Published by Cambridge University Press (CUP) in Wearable Technologies
- Vol. 2
Real-time gait metric estimation for everyday gait training with wearable devices in people poststroke
Hemiparetic walking after stroke is typically slow, asymmetric, and inefficient, significantly impacting activities of daily living. Extensive research shows that functional, intensive, and task-specific gait training is instrumental for effective gait rehabilitation, characteristics that our group aims to encourage with soft robotic exosuits. However, standard clinical assessments may lack the precision and frequency to detect subtle changes in intervention efficacy during both conventional and exosuit-assisted gait training, potentially impeding targeted therapy regimes. In this paper, we use exosuit-integrated inertial sensors to reconstruct three clinically meaningful gait metrics related to circumduction, foot clearance, and stride length. Our method corrects sensor drift using instantaneous information from both sides of the body. This approach makes our method robust to irregular walking conditions poststroke as well as usable in real-time applications, such as real-time movement monitoring, exosuit assistance control, and biofeedback. We validate our algorithm in eight people poststroke in comparison to lab-based optical motion capture. Mean errors were below 0.2 cm (9.9%) for circumduction, −0.6 cm (−3.5%) for foot clearance, and 3.8 cm (3.6%) for stride length. A single-participant case study shows our technique’s promise in daily-living environments by detecting exosuit-induced changes in gait while walking in a busy outdoor plaza.
- 25 March 2021
- Published by Cambridge University Press (CUP) in Wearable Technologies
- Vol. 2
Open AccessReal-time gait metric estimation for everyday gait training with wearable devices in people poststroke
Hemiparetic walking after stroke is typically slow, asymmetric, and inefficient, significantly impacting activities of daily living. Extensive research shows that functional, intensive, and task-specific gait training is instrumental for effective gait rehabilitation, characteristics that our group aims to encourage with soft robotic exosuits. However, standard clinical assessments may lack the precision and frequency to detect subtle changes in intervention efficacy during both conventional and exosuit-assisted gait training, potentially impeding targeted therapy regimes. In this paper, we use exosuit-integrated inertial sensors to reconstruct three clinically meaningful gait metrics related to circumduction, foot clearance, and stride length. Our method corrects sensor drift using instantaneous information from both sides of the body. This approach makes our method robust to irregular walking conditions poststroke as well as usable in real-time applications, such as real-time movement monitoring, exosuit assistance control, and biofeedback. We validate our algorithm in eight people poststroke in comparison to lab-based optical motion capture. Mean errors were below 0.2 cm (9.9%) for circumduction, −0.6 cm (−3.5%) for foot clearance, and 3.8 cm (3.6%) for stride length. A single-participant case study shows our technique’s promise in daily-living environments by detecting exosuit-induced changes in gait while walking in a busy outdoor plaza.
- Open Access
- 1 January 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 83, 76-84
Comparison of the human-exosuit interaction using ankle moment and ankle positive power inspired walking assistance
- 1 January 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 83, 76-84
Open AccessComparison of the human-exosuit interaction using ankle moment and ankle positive power inspired walking assistance
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2820-2827
A Lightweight and Efficient Portable Soft Exosuit for Paretic Ankle Assistance in Walking After Stroke
Hemiparetic gait after stroke is typically asymmetric and energetically inefficient. A major contributor to walking deficits is impaired paretic ankle function. Impaired paretic ankle plantarflexion (PF) reduces forward propulsion symmetry and impaired paretic ankle dorsiflexion (DF) diminishes ground clearance during swing. We have developed soft wearable robots (soft exosuits) to assist paretic PF and DF during walking after stroke. Through experimental studies with poststroke patients, we have demonstrated that exosuits can improve forward propulsion symmetry and ground clearance in walking, ultimately reducing the metabolic cost of walking. This paper presents an optimized soft exosuit aimed at use in clinical gait training for patients poststroke. The optimized exosuit is lightweight, easy to don and doff, and capable of efficiently delivering mechanical assistance to the paretic ankle. This paper focuses on the optimized controller that can deliver well-timed consistent ankle assistance to patients. A preliminary study was performed using this exosuit with three poststroke patients with heterogeneous gait patterns. Results showed that compared to a previously published controller, more consistent assistive force profiles could be delivered to individuals poststroke while consuming 50% less electrical power. Additionally, a preliminary biomechanical assessment was performed during overground walking.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2820-2827
A Lightweight and Efficient Portable Soft Exosuit for Paretic Ankle Assistance in Walking After Stroke
Hemiparetic gait after stroke is typically asymmetric and energetically inefficient. A major contributor to walking deficits is impaired paretic ankle function. Impaired paretic ankle plantarflexion (PF) reduces forward propulsion symmetry and impaired paretic ankle dorsiflexion (DF) diminishes ground clearance during swing. We have developed soft wearable robots (soft exosuits) to assist paretic PF and DF during walking after stroke. Through experimental studies with poststroke patients, we have demonstrated that exosuits can improve forward propulsion symmetry and ground clearance in walking, ultimately reducing the metabolic cost of walking. This paper presents an optimized soft exosuit aimed at use in clinical gait training for patients poststroke. The optimized exosuit is lightweight, easy to don and doff, and capable of efficiently delivering mechanical assistance to the paretic ankle. This paper focuses on the optimized controller that can deliver well-timed consistent ankle assistance to patients. A preliminary study was performed using this exosuit with three poststroke patients with heterogeneous gait patterns. Results showed that compared to a previously published controller, more consistent assistive force profiles could be delivered to individuals poststroke while consuming 50% less electrical power. Additionally, a preliminary biomechanical assessment was performed during overground walking.
- 15 November 2017
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 220 (22) , 4169-4176
Lower limb biomechanical analysis during an unanticipated step on a bump reveals specific adaptations of walking on uneven terrains
Although it is clear that walking over different irregular terrain is associated with altered biomechanics, there is little understanding of how we quickly adapt to unexpected variations in terrain. This study aims to investigate which adaptive strategies humans adopt when performing an unanticipated step on an irregular surface, specifically a small bump. Nine healthy male participants walked at their preferred walking speed along a straight walkway during five conditions: four involving unanticipated bumps of two different heights, and one level walking condition. Muscle activation of eight lower limb muscles and three-dimensional gait analysis were evaluated during these testing conditions. Two distinct adaptive strategies were found, which involved no significant change in total lower limb mechanical work or walking speed. An ankle-based strategy was adopted when stepping on a bump with the forefoot, whereas a hip-based strategy was preferred when stepping with the rearfoot. These strategies were driven by a higher activation of the plantarflexor muscles (6–51%), which generated a higher ankle joint moment during the forefoot conditions and by a higher activation of the quadriceps muscles (36–93%), which produced a higher knee joint moment and hip joint power during the rearfoot conditions. These findings provide insights into how humans quickly react to unexpected events and could be used to inform the design of adaptive controllers for wearable robots intended for use in unstructured environments that can provide optimal assistance to the different lower limb joints.
- 15 November 2017
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 220 (22) , 4169-4176
Lower limb biomechanical analysis during an unanticipated step on a bump reveals specific adaptations of walking on uneven terrains
Although it is clear that walking over different irregular terrain is associated with altered biomechanics, there is little understanding of how we quickly adapt to unexpected variations in terrain. This study aims to investigate which adaptive strategies humans adopt when performing an unanticipated step on an irregular surface, specifically a small bump. Nine healthy male participants walked at their preferred walking speed along a straight walkway during five conditions: four involving unanticipated bumps of two different heights, and one level walking condition. Muscle activation of eight lower limb muscles and three-dimensional gait analysis were evaluated during these testing conditions. Two distinct adaptive strategies were found, which involved no significant change in total lower limb mechanical work or walking speed. An ankle-based strategy was adopted when stepping on a bump with the forefoot, whereas a hip-based strategy was preferred when stepping with the rearfoot. These strategies were driven by a higher activation of the plantarflexor muscles (6–51%), which generated a higher ankle joint moment during the forefoot conditions and by a higher activation of the quadriceps muscles (36–93%), which produced a higher knee joint moment and hip joint power during the rearfoot conditions. These findings provide insights into how humans quickly react to unexpected events and could be used to inform the design of adaptive controllers for wearable robots intended for use in unstructured environments that can provide optimal assistance to the different lower limb joints.
- Open Access
- 19 September 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (9) , e0184054
Human-in-the-loop Bayesian optimization of wearable device parameters
The increasing capabilities of exoskeletons and powered prosthetics for walking assistance have paved the way for more sophisticated and individualized control strategies. In response to this opportunity, recent work on human-in-the-loop optimization has considered the problem of automatically tuning control parameters based on realtime physiological measurements. However, the common use of metabolic cost as a performance metric creates significant experimental challenges due to its long measurement times and low signal-to-noise ratio. We evaluate the use of Bayesian optimization—a family of sample-efficient, noise-tolerant, and global optimization methods—for quickly identifying near-optimal control parameters. To manage experimental complexity and provide comparisons against related work, we consider the task of minimizing metabolic cost by optimizing walking step frequencies in unaided human subjects. Compared to an existing approach based on gradient descent, Bayesian optimization identified a near-optimal step frequency with a faster time to convergence (12 minutes, p < 0.01), smaller inter-subject variability in convergence time (± 2 minutes, p < 0.01), and lower overall energy expenditure (p < 0.01).
- 19 September 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (9) , e0184054
Open AccessHuman-in-the-loop Bayesian optimization of wearable device parameters
The increasing capabilities of exoskeletons and powered prosthetics for walking assistance have paved the way for more sophisticated and individualized control strategies. In response to this opportunity, recent work on human-in-the-loop optimization has considered the problem of automatically tuning control parameters based on realtime physiological measurements. However, the common use of metabolic cost as a performance metric creates significant experimental challenges due to its long measurement times and low signal-to-noise ratio. We evaluate the use of Bayesian optimization—a family of sample-efficient, noise-tolerant, and global optimization methods—for quickly identifying near-optimal control parameters. To manage experimental complexity and provide comparisons against related work, we consider the task of minimizing metabolic cost by optimizing walking step frequencies in unaided human subjects. Compared to an existing approach based on gradient descent, Bayesian optimization identified a near-optimal step frequency with a faster time to convergence (12 minutes, p < 0.01), smaller inter-subject variability in convergence time (± 2 minutes, p < 0.01), and lower overall energy expenditure (p < 0.01).
- Open Access
- 12 July 2017
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 14 (1) , 1-13
Continuous sweep versus discrete step protocols for studying effects of wearable robot assistance magnitude
Different groups developed wearable robots for walking assistance, but there is still a need for methods to quickly tune actuation parameters for each robot and population or sometimes even for individual users. Protocols where parameters are held constant for multiple minutes have traditionally been used for evaluating responses to parameter changes such as metabolic rate or walking symmetry. However, these discrete protocols are time-consuming. Recently, protocols have been proposed where a parameter is changed in a continuous way. The aim of the present study was to compare effects of continuously varying assistance magnitude with a soft exosuit against discrete step conditions. Seven participants walked on a treadmill wearing a soft exosuit that assists plantarflexion and hip flexion. In Continuous-up, peak exosuit ankle moment linearly increased from approximately 0 to 38% of biological moment over 10 min. Continuous-down was the opposite. In Discrete, participants underwent five periods of 5 min with steady peak moment levels distributed over the same range as Continuous-up and Continuous-down. We calculated metabolic rate for the entire Continuous-up and Continuous-down conditions and the last 2 min of each Discrete force level. We compared kinematics, kinetics and metabolic rate between conditions by curve fitting versus peak moment. Reduction in metabolic rate compared to Powered-off was smaller in Continuous-up than in Continuous-down at most peak moment levels, due to physiological dynamics causing metabolic measurements in Continuous-up and Continuous-down to lag behind the values expected during steady-state testing. When evaluating the average slope of metabolic reduction over the entire peak moment range there was no significant difference between Continuous-down and Discrete. Attempting to correct the lag in metabolics by taking the average of Continuous-up and Continuous-down removed all significant differences versus Discrete. For kinematic and kinetic parameters, there were no differences between all conditions. The finding that there were no differences in biomechanical parameters between all conditions suggests that biomechanical parameters can be recorded with the shortest protocol condition (i.e. single Continuous directions). The shorter time and higher resolution data of continuous sweep protocols hold promise for the future study of human interaction with wearable robots.
- 12 July 2017
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 14 (1) , 1-13
Open AccessContinuous sweep versus discrete step protocols for studying effects of wearable robot assistance magnitude
Different groups developed wearable robots for walking assistance, but there is still a need for methods to quickly tune actuation parameters for each robot and population or sometimes even for individual users. Protocols where parameters are held constant for multiple minutes have traditionally been used for evaluating responses to parameter changes such as metabolic rate or walking symmetry. However, these discrete protocols are time-consuming. Recently, protocols have been proposed where a parameter is changed in a continuous way. The aim of the present study was to compare effects of continuously varying assistance magnitude with a soft exosuit against discrete step conditions. Seven participants walked on a treadmill wearing a soft exosuit that assists plantarflexion and hip flexion. In Continuous-up, peak exosuit ankle moment linearly increased from approximately 0 to 38% of biological moment over 10 min. Continuous-down was the opposite. In Discrete, participants underwent five periods of 5 min with steady peak moment levels distributed over the same range as Continuous-up and Continuous-down. We calculated metabolic rate for the entire Continuous-up and Continuous-down conditions and the last 2 min of each Discrete force level. We compared kinematics, kinetics and metabolic rate between conditions by curve fitting versus peak moment. Reduction in metabolic rate compared to Powered-off was smaller in Continuous-up than in Continuous-down at most peak moment levels, due to physiological dynamics causing metabolic measurements in Continuous-up and Continuous-down to lag behind the values expected during steady-state testing. When evaluating the average slope of metabolic reduction over the entire peak moment range there was no significant difference between Continuous-down and Discrete. Attempting to correct the lag in metabolics by taking the average of Continuous-up and Continuous-down removed all significant differences versus Discrete. For kinematic and kinetic parameters, there were no differences between all conditions. The finding that there were no differences in biomechanical parameters between all conditions suggests that biomechanical parameters can be recorded with the shortest protocol condition (i.e. single Continuous directions). The shorter time and higher resolution data of continuous sweep protocols hold promise for the future study of human interaction with wearable robots.
- Open Access
- 26 June 2017
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 14 (1) , 1-12
Varying negative work assistance at the ankle with a soft exosuit during loaded walking
Only very recently, studies have shown that it is possible to reduce the metabolic rate of unloaded and loaded walking using robotic ankle exoskeletons. Some studies obtained this result by means of high positive work assistance while others combined negative and positive work assistance. There is no consensus about the isolated contribution of negative work assistance. Therefore, the aim of the present study is to examine the effect of varying negative work assistance at the ankle joint while maintaining a fixed level of positive work assistance with a multi-articular soft exosuit. We tested eight participants during walking at 1.5 ms−1 with a 23-kg backpack. Participants wore a version of the exosuit that assisted plantarflexion via Bowden cables tethered to an off-board actuation platform. In four active conditions we provided different rates of exosuit bilateral ankle negative work assistance ranging from 0.015 to 0.037 W kg−1 and a fixed rate of positive work assistance of 0.19 W kg−1. All active conditions significantly reduced metabolic rate by 11 to 15% compared to a reference condition, where the participants wore the exosuit but no assistance was provided. We found no significant effect of negative work assistance. However, there was a trend (p = .08) toward greater reduction in metabolic rate with increasing negative work assistance, which could be explained by observed reductions in biological ankle and hip joint power and moment. The non-significant trend of increasing negative work assistance with increasing reductions in metabolic rate motivates the value in further studies on the relative effects of negative and positive work assistance. There may be benefit in varying negative work over a greater range or in isolation from positive work assistance.
- 26 June 2017
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 14 (1) , 1-12
Open AccessVarying negative work assistance at the ankle with a soft exosuit during loaded walking
Only very recently, studies have shown that it is possible to reduce the metabolic rate of unloaded and loaded walking using robotic ankle exoskeletons. Some studies obtained this result by means of high positive work assistance while others combined negative and positive work assistance. There is no consensus about the isolated contribution of negative work assistance. Therefore, the aim of the present study is to examine the effect of varying negative work assistance at the ankle joint while maintaining a fixed level of positive work assistance with a multi-articular soft exosuit. We tested eight participants during walking at 1.5 ms−1 with a 23-kg backpack. Participants wore a version of the exosuit that assisted plantarflexion via Bowden cables tethered to an off-board actuation platform. In four active conditions we provided different rates of exosuit bilateral ankle negative work assistance ranging from 0.015 to 0.037 W kg−1 and a fixed rate of positive work assistance of 0.19 W kg−1. All active conditions significantly reduced metabolic rate by 11 to 15% compared to a reference condition, where the participants wore the exosuit but no assistance was provided. We found no significant effect of negative work assistance. However, there was a trend (p = .08) toward greater reduction in metabolic rate with increasing negative work assistance, which could be explained by observed reductions in biological ankle and hip joint power and moment. The non-significant trend of increasing negative work assistance with increasing reductions in metabolic rate motivates the value in further studies on the relative effects of negative and positive work assistance. There may be benefit in varying negative work over a greater range or in isolation from positive work assistance.
- 5 October 2016
- Published by Springer Nature
- p. 107-111
Evaluation of Force Tracking Controller with Soft Exosuit for Hip Extension Assistance
- 5 October 2016
- Published by Springer Nature
- p. 107-111
Evaluation of Force Tracking Controller with Soft Exosuit for Hip Extension Assistance