TPTodd Pawlicki

Todd Pawlicki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Todd Pawlicki has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A system‐based operational assessment of external beam radiotherapy

    by Lawrence M. Wong, Todd Pawlicki

    Purpose: Advanced technologies have led to improvements in modern radiotherapy over the years. However, adoption of advanced technologies can present challenges to existing clinical operations and negatively impact safety. The purpose of this work is to perform an assessment of modern radiotherapy for the operational objectives of safety, efficiency, and financial viability.Methods: This work focuses on external beam radiotherapy (EBRT). The operational assessment included department management, treatment planning, treatment delivery, and associated workflows for three equipment configurations of Ethos, Halcyon, and TrueBeam with the ARIA information system, Eclipse treatment planning, and IDENTIFY surface guidance. Systems‐theoretic process analysis (STPA) was used to analyze the related workflows. Control actions, unsafe contexts of those control actions, and associated causal scenarios that can lead to unsafe radiation and non‐radiation physical injury (safety objective), reduced treatment capacity (efficiency objective), and costs that exceed budget (financial viability objective) were identified.Results: The number of control actions (and causal scenarios) were 18 (254), 18 (267), and 20 (267) for the equipment configurations of Halcyon, TrueBeam, and Ethos, respectively. The extent that safety, efficiency, and financial viability were impacted is similar across the different equipment configurations, but there were some noteworthy differences related to information transfer and workflow bottlenecks potentially impacting access to care. Seventy‐five percent of the scenarios across all three configurations were related to safety. Overall, 29% of the scenarios impacted more than one operational objective and 48% were related to human decisions during the process of care. Planned or unplanned process changes were responsible for 8% of the causal scenarios.Conclusions: Broad‐based clinical improvements may be realized by addressing causal scenarios that impact multiple objectives. Redesigning the roles and responsibilities of the clinical team and some aspects of the radiotherapy workflow may be helpful to fully realize the benefits of advanced technologies. Radiotherapy may benefit from additional tools to improve the consistency between decisions and actions when system or process changes occur.


  • Open Access

    Clinical safety assessment of the Halcyon system

    by Todd Pawlicki, Todd Atwood, Kristen McConnell, Gwe-Ya Kim

    Purpose: The Halcyon consists of precommissioned linear accelerator and treatment planning algorithms that were designed to simplify the acceptance, commissioning, and clinical workflow for image‐guided intensity‐modulated radiotherapy. The purpose of this work was to perform a comprehensive safety assessment for the clinical use of the Halcyon.Methods: Systems‐Theoretic Process Analysis was used as the safety assessment tool. As part of the analysis, a number of control loops and control actions are created to describe system function. Safety is assessed by determining unsafe control actions and a corresponding list of causal scenarios that leads to accidents. The scope of the analysis was from the acceptance of the Halcyon to routine patient treatments. All aspects of treating patients were considered including the roles of physicians, physicists, dosimetrists, and therapists. The analysis was completed by four physicists with input from other members of the radiation therapy team. The causal scenarios were summarized using the causality categories from the consensus recommendations for incident learning database structures in radiation oncology (Med Phys, Vol. 39, No. 12, Dec 2012).Results: Twenty‐three (23) control loops containing 52 control actions were created for the clinical use of the Halcyon. One hundred forty‐four (144) unsafe control actions were identified with 385 associated causal scenarios. Twenty‐seven percent (27%) of the causal scenarios were related to equipment technical issues, while 73% of the causal scenarios were predominantly related to procedural issues, human behavior, and organizational management.Conclusions: For routine clinical use of closed or largely automated radiation therapy equipment, the majority of safety concerns is related to nontechnical issues. The Halcyon and other similar systems may present opportunities to streamline, reduce, or eliminate some traditional equipment commissioning and routine quality assurance activities in exchange for an increased focus on issues related to organizational management, procedures, and human behavior.


  • Open Access

    Proposed changes to the American Association of Physicists in Medicine governance

    by Todd Pawlicki, Rex G. Ayers, Kristy K. Brock, Jessica B. Clements, Bruce H. Curran, James T. Dobbins, Ehsan Samei, Eva Adams, Melissa Carol Martin, Lisa Schober

  • Open Access

    Application of systems and control theory‐based hazard analysis to radiation oncology

    by Todd Pawlicki, Aubrey Samost, Derek W. Brown, Ryan P. Manger, Gwe‐Ya Kim, Nancy G. Leveson

    Purpose: Both humans and software are notoriously challenging to account for in traditional hazard analysis models. The purpose of this work is to investigate and demonstrate the application of a new, extended accident causality model, called systems theoretic accident model and processes (STAMP), to radiation oncology. Specifically, a hazard analysis technique based on STAMP, system‐theoretic process analysis (STPA), is used to perform a hazard analysis.Methods: The STPA procedure starts with the definition of high‐level accidents for radiation oncology at the medical center and the hazards leading to those accidents. From there, the hierarchical safety control structure of the radiation oncology clinic is modeled, i.e., the controls that are used to prevent accidents and provide effective treatment. Using STPA, unsafe control actions (behaviors) are identified that can lead to the hazards as well as causal scenarios that can lead to the identified unsafe control. This information can be used to eliminate or mitigate potential hazards. The STPA procedure is demonstrated on a new online adaptive cranial radiosurgery procedure that omits the CT simulation step and uses CBCT for localization, planning, and surface imaging system during treatment.Results: The STPA procedure generated a comprehensive set of causal scenarios that are traced back to system hazards and accidents. Ten control loops were created for the new SRS procedure, which covered the areas of hospital and department management, treatment design and delivery, and vendor service. Eighty three unsafe control actions were identified as well as 472 causal scenarios that could lead to those unsafe control actions.Conclusions: STPA provides a method for understanding the role of management decisions and hospital operations on system safety and generating process design requirements to prevent hazards and accidents. The interaction of people, hardware, and software is highlighted. The method of STPA produces results that can be used to improve safety and prevent accidents and warrants further investigation.


  • Learning to Appreciate Swiss Cheese and Other Industrial Engineering Concepts

    by Lawrence B. Marks, Todd A. Pawlicki, James Alan Hayman