XHXiao-Mei Hou

Xiao-Mei Hou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiao-Mei Hou has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Yi Han

    The Second Dental Center of Peking University School of Stomatology, Beijing, China

    2 shared publications
  • Benxiang Hou

    Center for Microscope Enhanced Dentistry, School of Stomatology, Capital Medical University, Beijing, China

    1 shared publication
  • Chan Yuan Jin

    Peking Univ Sch & Hosp Stomatol, Dent Ctr 2, Natl Ctr Stomatol, Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China

    1 shared publication
  • Chanyuan Jin

    Second Clinical Division, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing, China

    1 shared publication
  • Chanyuan Jin

    Peking University School and Hospital of Stomatology, Beijing, 10081, China

    1 shared publication
  • Chunping Lin

    Department of Stomatology, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou 350001, China

    1 shared publication

Latest Publications

  • Open Access

    Research Status of Silver Nanoparticles for Dental Applications

    by Yanyan Guo, Xiaomei Hou, Sanjun Fan, Chanyuan Jin

    Silver nanoparticles (AgNPs) have emerged as a promising antimicrobial agent in dentistry due to their distinctive physicochemical characteristics and broad-spectrum biocidal activity. For example, silver nanoparticles can be incorporated into oral hygiene products in preventive dentistry, composite resins in restorative treatment, irrigation solutions in endodontic treatment, membranes for guided tissue regeneration in periodontal treatment, acrylic resins and porcelains in prosthodontic treatment, coatings in dental implant treatment, and brackets and wires in orthodontic treatment. This paper focuses on summarizing the current knowledge on the antimicrobial use of silver nanoparticles in dentistry, highlighting their antimicrobial mechanism and potential applications in clinical treatment. The literature indicates that silver nanoparticles are a promising antimicrobial agent in dentistry. However, there are still many issues including fundamental antibacterial mechanisms that need to be completely elucidated before clinical applications.


  • [Knockdown of NPTX1 promotes osteogenic differentiation of human bone marrow mesenchymal stem cells].

    by Ting Shuai, Yanyan Guo, Chunping Lin, Xiaomei Hou, Chanyuan Jin

    To initially investigate the function of neuronal pentraxin 1 (NPTX1) gene on osteogenic differentiation of human bone marrow mesenchymal stem cells (hBMSCs). hBMSCs were induced to undergo osteogenic differentiation, and then RNA was collected at different time points, namely 0, 3, 7, 10 and 14 d. The mRNA expression levels of key genes related with osteogenic differentiation, including runt-related transcription factor 2 (RUNX2), alkaline phosphatase (ALP), osteocalcin (OCN), and NPTX1, were detected on the basis of quantitative real-time polymerase chain reaction (qPCR) technology. In order to establish a stable NPTX1-knockdown hBMSCs cell line, NPTX1 shRNA lentivirus was constructed and used to infect hBMSCs. ALP staining, alizarin red (AR) staining, and qPCR were employed to assess the impact of NPTX1-knockdown on the osteogenic differentiation ability of hBMSCs. The results showed that during the osteogenic differentiation of hBMSCs in vitro, the mRNA expression levels of osteogenic genes RUNX2, ALP and OCN significantly increased compared with 0 d, while NPTX1 expression decreased markedly (P < 0.01) as the osteogenic induction period exten-ded. At 72 h post-infection with lentivirus, the result of qPCR indicated that the knockdown efficiency of NPTX1 was over 60%. After knocking down NPTX1 in hBMSCs, RNA was extracted from both the NPTX1-knockdown group (sh NPTX1 group) and the control group (shNC group) cultured in regular proliferation medium. The results of qPCR showed that the expression levels of osteogenic-related genes RUNX2 and osterix (OSX) were significantly higher in the sh NPTX1 group compared with the shNC group (P < 0.01). ALP staining revealed a significantly deeper coloration in the sh NPTX1 group than in the shNC group at the end of 7 d of osteogenic induction. AR staining demonstrated a marked increase in mineralized nodules in the sh NPTX1 group compared with the shNC group at the end of 14 d of osteogenic induction. NPTX1 exerts a modulatory role in the osteogenic differentiation of hBMSCs, and its knockdown has been found to enhance the osteogenic differentiation of hBMSCs. This finding implies that NPTX1 could potentially serve as a therapeutic target for the treatment of osteogenic abnormalities, including osteoporosis.

  • [Cyclic fatigue resistance of nickel-titanium files made by Gold heat treatment in simulated S-shaped root canals at different temperatures].

    by Wenxin Chen, Xiaomei Hou

    To compare the cyclic fatigue resistance of nickel-titanium files made by 3 new heat treatment in simulated S-shaped root canals at different temperatures. Gold heat-treated nickel-titanium files TruNatomy (25 mm, tip size 26#/0.04) and ProTaper Gold (25 mm, tip size 25#/0.08) were selected as the experimental group, M wire technique nickel-titanium file ProTaper Next (25 mm, tip size 25#/0.06) was selected as the control group. It was speculated that the Gold technique used in TruNatomy nickel-titanium file was R phase separation technique, which included a complete intermediate R-phase, increasing its flexibility. ProTaper Gold was a CM wire nickel-titanium file and the increased phase transformation temperature by heat treatment introduced martensite at room temperature, while it underwent gold heat treatment on the surface, generating an intermediate R phase during phase transformation, providing hyperelastic. ProTaper Next used M wire technique, M wire included austenite at room temperature, where heat mechanical processing introduced hardened martensite, which was incapable of participating phase transformation. Because of the lower elastic modulus of hardened martensite than austenite, the flexibility of the file was increased. Twenty instruments of each nickel-titanium file were submitted to the cyclic fatigue test by using a simulated canal with double curvatures at room tem-perature (24 ℃) and 65 ℃, 10 instruments of each nickel-titanium file were selected at each temperature (n=10). At the same temperature, the number of cyclic fatigue (NCF) and fragment length were analyzed by using One-Way analysis of variance at a significance level of P < 0.05. NCF and fragment length of the same nickel-titanium file at room temperature and 65 ℃ were compared by paired sample t test and the significance level was α=0.05. Fractured surfaces were analyzed by using scanning electron microscope. In double-curved canals, all the failure of the files due to cyclic fatigue was first seen in the apical curvature before the coronal curvature. At room temperature, in the apical curvature, NCF of TruNatomy was 344.4±96.6, ProTaper Gold was 175.0±56.1, ProTaper Next was 133.3±39.7, NCF of Tru Natomy was the highest (P < 0.05). In the coronal curvature, NCF of TruNatomy was 618.3± 75.3, ProTaper Gold was 327.5±111.8, ProTaper Next was 376.6±67.9, NCF of TruNatomy was also the highest (P < 0.05). There was no significant difference among the apical and coronal fragment length of the 3 nickel-titanium files (P>0.05). At 65 ℃, in the apical curvature, NCF of TruNatomy was 289.6±65.8, ProTaper Gold was 187.5±75.4, ProTaper Next was 103.0±38.5, NCF of TruNatomy was the highest (P < 0.05). In the coronal curvature, NCF of TruNatomy was 454.2±45.4, ProTaper Gold was 268.3±31.4, ProTaper Next was 283.8±31.7, NCF of TruNatomy was also the highest (P < 0.05). The apical fragment length of ProTaper Next was the highest (P < 0.05), and there was no significant difference among coronal fragment length of the 3 nickel-titanium files (P>0.05). Compared with room temperature, at 65 ℃, in the coronal curvature, NCF of TruNatomy decreased significantly (P < 0.05). The fractured surfaces of the three nickel-titanium files demonstrated typical cyclic fatigue. Gold heat-treated nickel-titanium file had better cyclic fatigue resistance than M wire nickel-titanium file in S-shaped root canals.

  • Open Access

    Management and prognosis of a vital cracked tooth by occlusal veneer for 14 months: A case report

    by Mengke Wang, Yingying Hong, Xiaomei Hou, Yinfei Pu

    Key Clinical Message: An occlusal veneer is an ultrathin restoration method and a minimally invasive approach that can preserve more dental tissue and provide better aesthetic outcomes, thus increasing patient satisfaction. An occlusal veneer is an ultrathin restoration method and a minimally invasive approach that can preserve more dental tissue and provide better aesthetic outcomes, thus increasing patient satisfaction; however, no previous studies reported on treating cracked teeth using occlusal veneer. Accordingly, we described the diagnosis and treatment process of a cracked tooth using occlusal veneer in a single case. A 29‐year‐old male presented at our dental clinic complaining of biting pain in the mandibular molar on the right‐hand side. A routine oral examination with radiography was performed to evaluate the oral condition and treatment planning. The #16 tooth had a crack line surrounding the whole distal–lingual cusp from the occlusal surface. After discussing various therapeutic options with the patient, an occlusal veneer was performed. One week after treatment with occlusal veneer, the patient had no complaints. A 14‐month follow‐up showed promising clinical and radiographic outcomes. Occlusal veneer is an alternative treatment option for a cracked tooth, as it can preserve more dental tissue and potentially save pulp vitality.


  • Small Molecule Nitazoxanide Inhibits Osteogenic Differentiation and Promotes Adipogenic Differentiation of Bone Marrow Mesenchymal Stem Cells

    by Chan Yuan Jin, Yan Yan Guo, Xiao Mei Hou, Zhi Hui Tang

    Objective: To investigate the potential effect of small molecule nitazoxanide (NTZ) on the osteogenic and adipogenic differentiation of bone marrow mesenchymal stem cells (BMSCs).Methods: Cell counting Kit-8 assay was used to examine the effect of NTZ on proliferation of BMSCs. Quantitative reverse transcription polymerase chain reaction (qRT-PCR) and Western blot analysis were used to measure the expression of osteogenic and adipogenic marker gene. Alkaline phosphatase (ALP) staining and activity assay and Alizarin Red S (ARS) staining were used to investigate the effect of NTZ on osteogenesis. Oil red 0 (ORO) staining assay was used to assess the impact of NTZ on adipogenesis.Results: NTZ significantly suppressed the osteogenic differentiation but promoted the adipo-genic differentiation of BMSCs. Mechanistically, NTZ regulated osteogenic/adipogenic dif-ferentiation of BMSCs by inhibiting the Wnt/O-catenin signalling pathway. The addition of Wnt/O-catenin signalling pathway activator, lithium chloride, could reverse the effect of NTZ on BMSCs.Conclusion: NTZ affected osteogenic and adipogenic differentiation of BMSCs with the involve-ment of Wnt/O-catenin signalling pathway. This finding expanded the understanding of NTZ pharmacology and indicated that NTZ might have an adverse effect on bone homeostasis.


  • Open Access

    Glide path enlargement of curved molar canals using HyFlex EDM glide path file versus PathFile: a comparative study of preparation time and postoperative pain

    by Yi Han, Xiao-Mei Hou

    Background: This randomized clinical trial aimed to compare the preparation time and severity of postoperative pain between HyFlex Electric Discharge Machine (EDM) glide path file (GPF) and PathFile.Methods: Eighty patients whose molar teeth had at least one severely curved canal were treated by the same specialist. After access cavity preparation, the patients were randomly assigned to receive glide path enlargement with either HyFlex EDM GPF or PathFile. ProTaper Next X1 and X2 files were used to prepare the canals. The time of preparation was assessed and the severity of postoperative pain over the next 7 days was recorded. The preparation time and the postoperative pain scores were compared using the Linear Mixed Models (P ≤ 0.05).Results: Glide path enlargement time was significantly shorter with HyFlex EDM GPF (27.828 ± 2.345 s) than with PathFile (48.942 ± 2.864 s) (P < 0.001). The highest postoperative pain score was recorded on the first day and the pain decreased over time in both groups. HyFlex EDM GPF group patients reported significantly less postoperative pain than PathFile group patients overall (P < 0.001).Conclusions: Postoperative pain and glide path preparation time could be reduced by using HyFlex EDM GPF system.Trial registrationPKUSSNCT, PKUSSNCT-17B12, Registered 24 October 2017.


  • Open Access

    Glide Path Enlargement of Curved Molar Canals Using HyFlex EDM Glide Path File versus PathFile: A Comparative Study of Preparation Time and Postoperative Pain

    by Yi Han, Xiao-Mei Hou

    Background: This randomized clinical trial aimed to compare the preparation time and severity of postoperative pain between the HyFlex Electric Discharge Machine (EDM) Glide Path File (GPF) and PathFile. Methods: Eighty patients whose molar teeth had at least one severely curved canal were treated by the same specialist. After access cavity preparation, the patients were randomly assigned to receive glide path enlargement with either HyFlex EDM GPF or PathFile. ProTaper Next X1 and X2 files were used to prepare the canals. The time of preparation was assessed and the severity of postoperative pain over the next 7 days was recorded. The preparation time and the postoperative pain scores were compared using one-way analysis of variance (ANOVA) (P ≤ 0.05).Results: Glide path enlargement time was significantly shorter with HyFlex EDM GPF (27.828 ± 2.345 sec) than with PathFile (48.942 ± 2.864 sec) (P < 0.001). The highest postoperative pain score was recorded on the first day and the pain decreased over time in both groups. HyFlex EDM GPF group patients reported significantly less postoperative pain than PathFile group patients overall (P < 0.05). Conclusion: Postoperative pain and glide path preparation time could be reduced by using the HyFlex EDM GPF system.Trial registration: PKUSSNCT, PKUSSNCT-17B12, Registered 24 October 2017


  • 控制记忆合金丝镍钛根管锉弯曲性能有限元分析模型的构建及力学分析

    by H Y Fu, F F Wang, X M Hou

    通过三维有限元实验方法建立模型,用来评价控制记忆合金丝(controlled memory,CM)镍钛根管锉的弯曲性能,并将其与其他相同几何形态的镍钛合金进行比较。 基于逆向工程技术,将21 mm长、25#/08锥度的Hyflex NT和Hyflex CM镍钛锉通过悬臂弯曲模型在距锉尖9.5 mm处固定,力学检测仪压头在距锉尖3 mm处加载/卸载力,最大位移3 mm,得到载荷位移曲线,随后使用显微CT扫描(层间距8 μm)镍钛锉,导入ABAQUS (6.10)构建几何模型。Hyflex NT以形状记忆合金本构模型,Hyflex CM以幂硬化塑性本构模型,拟合悬臂弯曲的载荷位移曲线。 成功构建两个四面体单元模型,节点总数均为99 353,单元总数均为63 744。当加载位移为1 mm时,对距锉尖6.1 mm处的横截面进行应力分布观测,上、下表面受到的弯曲应力最大,并率先进入相变屈服阶段,有限元模拟能够清楚地给出锉在变形过程中的变形特点、应力分布等各种信息,与实际实验曲线拟合度好。 材料本构行为对于镍钛根管锉力学行为的影响十分显著,针对CM丝镍钛根管锉的特性调试参数而建立的有限元模型能够精确地捕捉镍钛根管锉各种变形过程中的特点,且与实际实验曲线拟合度好,可用于CM丝镍钛锉弯曲性能研究。

  • Open Access

    Post endodontic pain following single-visit root canal preparation with rotary vs reciprocating instruments: a meta-analysis of randomized clinical trials

    by Xiao-Mei Hou, Zheng Su, Ben-Xiang Hou

    In endodontic therapy, continuous rotary instrumentation reduced debris compared to reciprocal instrumentation, which might affect the incidence of post-endodontic pain (PP). The aim of our study was to assess whether PP incidence and levels were influenced by the choice of rotary or reciprocal instruments. In this meta-analysis the Pubmed and EM databases were searched for prospective clinical randomized trials published before April 20, 2016, using combinations of the keywords: root canal preparation/instrumentation/treatment/therapy; post-operative/endodontic pain; reciprocal and rotary instruments. Three studies were included, involving a total of 1,317 patients, 659 treated with reciprocating instruments and 658 treated with rotary instruments. PP was reported in 139 patients in the reciprocating group and 172 in the rotary group. The PP incidence odds ratio was 1.27 with 95% confidence interval (CI) (0.25, 6.52) favoring rotary instruments. The mild, moderate and severe PP levels odds ratios were 0.31 (0.11, 0.84), 2.24 (0.66, 7.59) and 11.71 (0.63, 218.15), respectively. No evidence of publication bias was found. Rotary instrument choice in endodontic therapy is associated with a lower incidence of PP than reciprocating instruments, while reciprocating instruments are associated with less mild PP incidence.