HTHiroo Takayama

Hiroo Takayama

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hiroo Takayama has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Increased de novo ceramide synthesis and accumulation in failing myocardium

    by Ruiping Ji, Hirokazu Akashi, Konstantinos Drosatos, Xianghai Liao, Hongfeng Jiang, Peter J. Kennel, Danielle L. Brunjes, Estibaliz Castillero, Xiaokan Zhang, Lily Y. Deng, et al.

    Abnormal lipid metabolism may contribute to myocardial injury and remodeling. To determine whether accumulation of very long–chain ceramides occurs in human failing myocardium, we analyzed myocardial tissue and serum from patients with severe heart failure (HF) undergoing placement of left ventricular assist devices and controls. Lipidomic analysis revealed increased total and very long–chain ceramides in myocardium and serum of patients with advanced HF. After unloading, these changes showed partial reversibility. Following myocardial infarction (MI), serine palmitoyl transferase (SPT), the rate-limiting enzyme of the de novo pathway of ceramide synthesis, and ceramides were found increased. Blockade of SPT by the specific inhibitor myriocin reduced ceramide accumulation in ischemic cardiomyopathy and decreased C16, C24:1, and C24 ceramides. SPT inhibition also reduced ventricular remodeling, fibrosis, and macrophage content following MI. Further, genetic deletion of the SPTLC2 gene preserved cardiac function following MI. Finally, in vitro studies revealed that changes in ceramide synthesis are linked to hypoxia and inflammation. In conclusion, cardiac ceramides accumulate in the failing myocardium, and increased levels are detectable in circulation. Inhibition of de novo ceramide synthesis reduces cardiac remodeling. Thus, increased de novo ceramide synthesis contributes to progressive pathologic cardiac remodeling and dysfunction.


  • Open Access

    Feasibility and safety of continuous retrograde administration of Del Nido cardioplegia: a case series

    by Marc Najjar, Isaac George, Hirokazu Akashi, Takashi Nishimura, Halit Yerebakan, Linda Mongero, James Beck, Stephen C. Hill, Hiroo Takayama, Mathew R. Williams

    Del Nido (DN) cardioplegia, a calcium-free, hyperkalemic solution containing lidocaine and magnesium has been developed to help reduce intracellular calcium influx and the resulting myocyte damage in the immediate postischemic period following cardiac arrest. DN cardioplegia has been used for pediatric cardiac surgery but its use in complex reoperative surgery has not been studied. We specifically report the outcomes of patients undergoing reoperative cardiac surgery after previous coronary artery bypass grafting with a patent internal mammary artery (IMA). Patients undergoing reoperative cardiac surgery with prior coronary bypass grafting surgery were studied between 2010 and 2013. Fourteen patients were identified who required continued retrograde cardioplegia administration. In all cases, an initial antegrade dose was given, followed by continuous retrograde administration. Demographics, co-morbidities, intra-operative variables including cardioplegia volumes, post-operative complications, and patient outcomes were collected. The mean age of all patients was 73.3+/−6.7 years, and 93 % were male. Aortic cross clamp time and cardiopulmonary bypass times were 81+/−35 and 151+/−79 mins, respectively. Antegrade, retrograde and total cardioplegia doses were 1101+/−398, 3096+/−3185 and 4367+/−3751 ml, respectively. An average of 0.93+/−0.92 inotropes and 1.50+/−0.76 pressors were used on ICU admission after surgery. ICU and total hospital lengths of stay were 5.5+/−7.4 and 9.6+/−8.0 days, respectively. Complications occurred in two patients (14 %) (pneumonia and prolonged mechanical ventilation) and new arrhythmias occurred in five patients (36 %) (four new-onset atrial fibrillation and one pulseless electrical activity requiring 2 min of chest compression). No perioperative myocardial infarctions were noted based on electrocardiograms and cardiac serum markers. Postoperatively, left ventricular function was preserved in all patients whereas two patients (14 %) had mild decrease in right ventricular function as assessed by echocardiography. No mortality was observed. Del Nido cardioplegia solution provides acceptable myocardial protection for cardiac surgery that requires continuous retrograde cardioplegia administration. DN cardioplegia’s administration in a continuous retrograde fashion with a patent IMA is believed to provide adequate myocardial protection while avoiding injuring the IMA through dissection and clamping.


  • Open Access

    Rat model of veno-arterial extracorporeal membrane oxygenation

    by Ayyaz A Ali, Peter Downey, Gopal Singh, Wei Qi, Isaac George, Hiroo Takayama, Ajay Kirtane, Prakash Krishnan, Adrian Zalewski, Darren Freed, et al.

    We aim to develop a rat model of veno-arterial extracorporeal membrane oxygenation (VA-ECMO). VA-ECMO was established in twelve Male Sprague-Dawley rats (250-350 g) through cannulation of the right jugular vein for venous drainage and the right femoral artery for arterial reinfusion. Arterial blood pressure was measured using a conductance catheter through cannulation of the left carotid artery. Heart rate was monitored by electrocardiography and arterial blood gas parameters with a blood gas analyzer. The VA-ECMO circuit was tested by subjecting the rats to hypoxic cardiac arrest with resuscitation using VA-ECMO. Both load-dependent and load-independent measures of myocardial contractility were measured using pressure-volume loop analysis to confirm restoration of myocardial function post-resuscitation. Following hypoxic cardiac arrest VA-ECMO provided sufficient oxygenation to support the circulation. The haemodynamic and blood gas parameters were maintained at transition and during ECMO. All animals were resuscitated, regained cardiac function and were able to be weaned off ECMO post-resuscitation. We have established a safe, high-throughput, economical, functioning rat model of VA-ECMO.