Satish Perivilli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Satish Perivilli has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Erika Stippler
European Directorate for the Quality of Medicines and HealthCare, Strasbourg, France
3 shared publicationsMark R. Liddell
US Pharmacopeial Convention, Rockville, USA
1 shared publicationMaziar Kakhi
Food and Drug Administration, Office of Testing and Research
1 shared publicationRichard Prevost
LaVision Inc., 211 W. Michigan Ave./Suite 100, Ypsilanti, Michigan, 48197, USA
1 shared publicationSteven Walfish
US Pharmacopeial Convention, Rockville, USA
1 shared publication
Latest Publications
- Open Access
- 16 May 2022
- Published by Springer Nature in Pharmaceutical Research
- Vol. 39 (5) , 919-934
Impact of Select Geometric and Operational Parameters on Hydrodynamics in Dissolution Apparatus 2 (Paddle Apparatus): A Design of Experiments Analysis Based on Computational Fluid Dynamics Simulations
Purpose: A Design of Experiments (DOE) analysis driven by Computational Fluid Dynamics (CFD) simulations was used to evaluate individual and two-factor interaction effects of varying select geometric and operational parameters on the hydrodynamics in dissolution apparatus 2 (paddle apparatus). Methods: Simulations were run with meshing controls and solution strategies retained from a mesh-independent validated baseline model. Distance between vessel and impeller bottom surfaces, impeller offset, vessel radius and impeller rotation speed were considered as input parameters. The velocity magnitudes at four locations near the vessel bottom surface were considered as output parameters. Response surfaces and Pareto charts were generated to understand individual and two-factor interaction effects of input parameters on the output parameters. Results: Impeller offset has a dominating influence of a linear and quadratic nature on the output parameters and affects overall hydrodynamics. Changes to other input parameters have limited influence on velocity magnitudes at locations closest to the vessel axis and on overall hydrodynamics. However, these parameters have important influences of varying degrees on velocity magnitudes at locations away from the vessel axis. Conclusions: The hydrodynamics in Apparatus 2 is influenced differently by different parameters and their combinations. Impeller offset has a stronger influence when compared to parameters that do not alter apparatus symmetry.
- 16 May 2022
- Published by Springer Nature in Pharmaceutical Research
- Vol. 39 (5) , 919-934
Open AccessImpact of Select Geometric and Operational Parameters on Hydrodynamics in Dissolution Apparatus 2 (Paddle Apparatus): A Design of Experiments Analysis Based on Computational Fluid Dynamics Simulations
Purpose: A Design of Experiments (DOE) analysis driven by Computational Fluid Dynamics (CFD) simulations was used to evaluate individual and two-factor interaction effects of varying select geometric and operational parameters on the hydrodynamics in dissolution apparatus 2 (paddle apparatus). Methods: Simulations were run with meshing controls and solution strategies retained from a mesh-independent validated baseline model. Distance between vessel and impeller bottom surfaces, impeller offset, vessel radius and impeller rotation speed were considered as input parameters. The velocity magnitudes at four locations near the vessel bottom surface were considered as output parameters. Response surfaces and Pareto charts were generated to understand individual and two-factor interaction effects of input parameters on the output parameters. Results: Impeller offset has a dominating influence of a linear and quadratic nature on the output parameters and affects overall hydrodynamics. Changes to other input parameters have limited influence on velocity magnitudes at locations closest to the vessel axis and on overall hydrodynamics. However, these parameters have important influences of varying degrees on velocity magnitudes at locations away from the vessel axis. Conclusions: The hydrodynamics in Apparatus 2 is influenced differently by different parameters and their combinations. Impeller offset has a stronger influence when compared to parameters that do not alter apparatus symmetry.
- Open Access
- 13 April 2017
- Published by Springer Nature in Pharmaceutical Research
- Vol. 34 (6) , 1330-1337
Velocity Field Visualization in USP Dissolution Apparatus 3 Using Particle Image Velocimetry
The hydrodynamics in USP dissolution apparatus 3, at five different dip rates, was characterized by analyzing phase-averaged velocity fields obtained using Particle Image Velocimetry (PIV).
- 13 April 2017
- Published by Springer Nature in Pharmaceutical Research
- Vol. 34 (6) , 1330-1337
Open AccessVelocity Field Visualization in USP Dissolution Apparatus 3 Using Particle Image Velocimetry
The hydrodynamics in USP dissolution apparatus 3, at five different dip rates, was characterized by analyzing phase-averaged velocity fields obtained using Particle Image Velocimetry (PIV).
- 19 November 2014
- Published by Springer Nature in Pharmaceutical Research
- Vol. 32 (4) , 1304-1315
Computational Fluid Dynamics Simulation of Hydrodynamics in USP Apparatus 3—The Influence of Dip Rate
This study investigated the influence of dip rate on USP Apparatus 3 hydrodynamics in the presence of a solid dosage form (e.g. tablet) using Computational Fluid Dynamics (CFD) simulations. The primary variables of interest were the liquid phase velocity in the computational domain and wall shear stresses on the tablet surfaces. Geometry building and model setup were based on a number of simplifying assumptions. Computational grid-independent solutions were achieved for dip rates ranging from 5 to 10 dips per minute (dpm). For all cases studied, the hydrodynamics exhibited a periodicity dictated by the dip rate. Cycle-to-cycle variations were found to be negligible. Higher velocities were predicted in the wake of the tablet and they peaked at midway positions both during the up- and downstrokes of the cylinder. Three sub-regions of velocity were identified inside the reciprocating cylinder. Results also showed localized vortices/recirculations specific to the up- and downstroke, in addition to local stagnation zones. The wall shear stresses and velocity magnitudes scaled proportionately with increasing dip rates while exhibiting qualitatively similar behavior in their spatial and temporal distributions. Based on the predictions of the 2D axisymmetric CFD model, the hydrodynamics in USP Apparatus 3 is characterized by complex and periodic flow structures.
- 19 November 2014
- Published by Springer Nature in Pharmaceutical Research
- Vol. 32 (4) , 1304-1315
Computational Fluid Dynamics Simulation of Hydrodynamics in USP Apparatus 3—The Influence of Dip Rate
This study investigated the influence of dip rate on USP Apparatus 3 hydrodynamics in the presence of a solid dosage form (e.g. tablet) using Computational Fluid Dynamics (CFD) simulations. The primary variables of interest were the liquid phase velocity in the computational domain and wall shear stresses on the tablet surfaces. Geometry building and model setup were based on a number of simplifying assumptions. Computational grid-independent solutions were achieved for dip rates ranging from 5 to 10 dips per minute (dpm). For all cases studied, the hydrodynamics exhibited a periodicity dictated by the dip rate. Cycle-to-cycle variations were found to be negligible. Higher velocities were predicted in the wake of the tablet and they peaked at midway positions both during the up- and downstrokes of the cylinder. Three sub-regions of velocity were identified inside the reciprocating cylinder. Results also showed localized vortices/recirculations specific to the up- and downstroke, in addition to local stagnation zones. The wall shear stresses and velocity magnitudes scaled proportionately with increasing dip rates while exhibiting qualitatively similar behavior in their spatial and temporal distributions. Based on the predictions of the 2D axisymmetric CFD model, the hydrodynamics in USP Apparatus 3 is characterized by complex and periodic flow structures.