CLChristoph Leuze

Christoph Leuze

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christoph Leuze has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    EasyREG : Easy Depth-Based Markerless Registration and Tracking using Augmented Reality Device for Surgical Guidance

    by Yue Yang, Christoph Leuze, Brian Hargreaves, Bruce Daniel, Fred Baik

    The use of Augmented Reality (AR) devices for surgical guidance has gained increasing traction in the medical field. Traditional registration methods often rely on external fiducial markers to achieve high accuracy and real-time performance. However, these markers introduce cumbersome calibration procedures and can be challenging to deploy in clinical settings. While commercial solutions have attempted real-time markerless tracking using the native RGB cameras of AR devices, their accuracy remains questionable for medical guidance, primarily due to occlusions and significant outliers between the live sensor data and the preoperative target anatomy point cloud derived from MRI or CT scans. In this work, we present a markerless framework that relies only on the depth sensor of AR devices and consists of two modules: a registration module for high-precision, outlier-robust target anatomy localization, and a tracking module for real-time pose estimation. The registration module integrates depth sensor error correction, a human-in-the-loop region filtering technique, and a robust global alignment with curvature-aware feature sampling, followed by local ICP refinement, for markerless alignment of preoperative models with patient anatomy. The tracking module employs a fast and robust registration algorithm that uses the initial pose from the registration module to estimate the target pose in real-time. We comprehensively evaluated the performance of both modules through simulation and real-world measurements. The results indicate that our markerless system achieves superior performance for registration and comparable performance for tracking to industrial solutions. The two-module design makes our system a one-stop solution for surgical procedures where the target anatomy moves or stays static during surgery.


  • Multimodal Feedback for Handheld Tool Guidance: Combining Wrist-Based Haptics with Augmented Reality

    by Yue Yang, Christoph Leuze, Brian Hargreaves, Bruce Daniel, Fred Baik

    We investigate how vibrotactile wrist feedback can enhance spatial guidance for handheld tool movement in optical see-through augmented reality (AR). While AR overlays are widely used to support surgical tasks, visual occlusion, lighting conditions, and interface ambiguity can compromise precision and confidence. To address these challenges, we designed a multimodal system combining AR visuals with a custom wrist-worn haptic device delivering directional and state-based cues. A formative study with experienced surgeons and residents identified key tool maneuvers and preferences for reference mappings, guiding our cue design. In a cue identification experiment (N = 21), participants accurately recognized five vibration patterns under visual load, with higher recognition for full-actuator states than spatial direction cues. In a guidance task (N = 27), participants using both AR and haptics achieved significantly higher spatial precision (5.8 mm) and usability (SUS = 88.1) than those using either modality alone, albeit with modest increases in task time. Participants reported that haptic cues provided reassuring confirmation and reduced cognitive effort during alignment. Our results highlight the promise of integrating wrist-based haptics into AR systems for high-precision, visually complex tasks such as surgical guidance. We discuss design implications for multimodal interfaces supporting confident, efficient tool manipulation.

  • Standalone Augmented Reality Neuronavigation System for Accurate Pulse Delivery in Transcranial Magnetic Stimulation

    by Wally L. Niu, Christopher C. Cline, Bruce L. Daniel, Christoph Leuze

    Transcranial magnetic stimulation (TMS) is a noninvasive brain stimulation technique that uses magnetic pulses to safely modulate neural activity in specific brain regions, with particular use in the treatment of major depressive disorder. However, effective treatment protocols require multiple sessions over time and accurate targeting. Current neuronavigation systems can improve pulse delivery compared to standard scalp and measuring tape methods, but are costly and have time-intensive setups for recurring sessions. Wepresent an augmented reality neuronavigation system (AR-NS) that overcomes these limitations. The AR-NS is functionally similar to other neuronavigation systems but can operate entirely within a head-mounted display. Unlike traditional 2D navigation systems that require mentally fusing screen information with real-world actions, the AR interface allows operators to perform the procedure with reduced cognitive and hand-eye coordination demands. We measured the functional targeting accuracy of the AR-NS and the Localite TMSNavigator, a commercial neuronavigation system, using a TMS phantom we developed embedded with Hall effect sensors at four different sites. We determined the coil placement for each site that maximized the sensor response to a magnetic pulse using co-registered X-ray computed tomography and structured light scanner scans. A MagVenture C-B60 coil was placed and fired at each site 30 times in a randomized order according to each neuronavigation system. We measured the resulting magnetic pulse amplitudes. A non-inferiority test with a 5 mT margin and 97.5% confidence intervals indicated that the AR-NS demonstrated similar functional targeting accuracy as the Localite TMS Navigator across all but one stimulation site, indicating that augmented reality neuronavigation systems may offer more accessible delivery of TMS stimulation without sacrificing functional accuracy compared to current systems.

  • Open Access

    Multimodal Feedback for Handheld Tool Guidance: Combining Wrist-Based Haptics with Augmented Reality

    by Yue Yang, Christoph Leuze, Brian Hargreaves, Bruce Daniel, Fred M Baik

    We investigate how vibrotactile wrist feedback can enhance spatial guidance for handheld tool movement in optical see-through augmented reality (AR). While AR overlays are widely used to support surgical tasks, visual occlusion, lighting conditions, and interface ambiguity can compromise precision and confidence. To address these challenges, we designed a multimodal system combining AR visuals with a custom wrist-worn haptic device delivering directional and state-based cues. A formative study with experienced surgeons and residents identified key tool maneuvers and preferences for reference mappings, guiding our cue design. In a cue identification experiment (N=21), participants accurately recognized five vibration patterns under visual load, with higher recognition for full-actuator states than spatial direction cues. In a guidance task (N=27), participants using both AR and haptics achieved significantly higher spatial precision (5.8 mm) and usability (SUS = 88.1) than those using either modality alone, despite having modest increases in task time. Participants reported that haptic cues provided reassuring confirmation and reduced cognitive effort during alignment. Our results highlight the promise of integrating wrist-based haptics into AR systems for high-precision, visually complex tasks such as surgical guidance. We discuss design implications for multimodal interfaces supporting confident, efficient tool manipulation.

  • Open Access

    Markerless Augmented Reality Registration for Surgical Guidance: A Multi-Anatomy Clinical Accuracy Study

    by Yue Yang, Fabian Necker, Christoph Leuze, Michelle Chen, Andrey Finegersh, Jake Lee, Vasu Divi, Bruce Daniel, Brian Hargreaves, Jie Ying Wu, et al.

    Purpose: In this paper, we develop and clinically evaluate a depth-only, markerless augmented reality (AR) registration pipeline on a head-mounted display, and assess accuracy across small or low-curvature anatomies in real-life operative settings. Methods: On HoloLens 2, we align Articulated HAnd Tracking (AHAT) depth to Computed Tomography (CT)-derived skin meshes via (i) depth-bias correction, (ii) brief human-in-the-loop initialization, (iii) global and local registration. We validated the surface-tracing error metric by comparing "skin-to-bone" relative distances to CT ground truth on leg and foot models, using an AR-tracked tool. We then performed seven intraoperative target trials (feet x2, ear x3, leg x2) during the initial stage of fibula free-flap harvest and mandibular reconstruction surgery, and collected 500+ data per trial. Results: Preclinical validation showed tight agreement between AR-traced and CT distances (leg: median |Delta d| 0.78 mm, RMSE 0.97 mm; feet: 0.80 mm, 1.20 mm). Clinically, per-point error had a median of 3.9 mm. Median errors by anatomy were 3.2 mm (feet), 4.3 mm (ear), and 5.3 mm (lower leg), with 5 mm coverage 92-95%, 84-90%, and 72-86%, respectively. Feet vs. lower leg differed significantly (Delta median ~1.1 mm; p < 0.001). Conclusion: A depth-only, markerless AR pipeline on HMDs achieved ~3-4 mm median error across feet, ear, and lower leg in live surgical settings without fiducials, approaching typical clinical error thresholds for moderate-risk tasks. Human-guided initialization plus global-to-local registration enabled accurate alignment on small or low-curvature targets, improving the clinical readiness of markerless AR guidance.

  • Open Access

    Measuring Abdominal Skin‐Surface Distances Using Photos for Perforator Mapping Analysis—A Validation Study on 3D‐Printed DIEP‐Flap Models

    by Fabian N. Necker, David J. Cholok, Marc J. Fischer, Kyle Gifford, Chris Le Castillo, Michael Scholz, Michael Januszyk, Christoph W. Leuze, Bruce L. Daniel, Arash Momeni

    Background: We present a novel method for accurately measuring skin‐surface distances using standard smartphone photos and Photoshop, validated on 3D‐printed DIEP‐flap models and on calibration grid‐patterns. Materials and Methods: Distance measurements are acquired in Photoshop in a calibration plane between dots on a grid‐pattern as well as between perforators on photos of 3D‐printed models and compared against ground‐truth. Margins of errors are calculated from fitted linear models. Results: Submillimeter accuracy can be achieved within errors of ±0.45 mm (80% probability) and ±0.8 mm (95% probability) for measuring distances on the dot‐grid. On the 3D‐printed DIEP‐models, distance measurements are accurate within ±1.75 mm (80% probability) and ±3.1 mm (95% probability). Conclusions: We introduce a simple yet highly accurate technique to measure skin‐surface distances using normal photos. Depending on the scenario, submillimeter or conservatively very low millimetre errors can be achieved, sufficiently accurate for clinical use, whilst maintaining topographic relationships of the measurements.

  • Holographic Deep Inferior Epigastric Perforator Exploration in Mixed Reality using Real-Time Cinematic Rendering

    by Fabian N. Necker, David J. Cholok, Mohammed S. Shaheen, Marc J. Fischer, Kyle Gifford, Trishia El Chemaly, Christoph W. Leuze, Michael Scholz, Bruce L. Daniel, Arash Momeni

    Deep Inferior Epigastric Artery perforator flaps (DIEP flaps) have become the gold standard in autologous breast reconstruction; yet they remain complex procedures due to highly individual perforator anatomy. Increasingly, computed tomography (CT) angiography is used for preoperative planning but is conventionally viewed on 2D screens in black and white. With the rise of Virtual and Mixed Reality, early case studies have demonstrated the utility of 3D-Mixed Reality headsets for DIEP flap planning by immersively exploring projections of perforator anatomy. However, thus far, only segmentation- and volume rendering-based approaches have been used clinically. These techniques lack photorealism and do not ideally depict soft-tissue or high-resolution vascular detail. We describe a new holographic photorealistic rendering workflow on Mixed Reality headsets using Cinematic Anatomy that allows more accurate depth perception and, thus, a better understanding of perforator anatomy. Using hand-gestures to interact with a hologram derived by CT angiography, the surgeon can modify the rendering in real-time and interactively dissect parts of the Rectus Abdominis Muscle to get a more nuanced understanding of the sub- and intramuscular course of the vascular tree. Using different visualization settings, the spatial relationship of perforators to surrounding anatomical structures—especially the subcutaneous tissue and the Rectus Abdominis Muscle—can be understood more intuitively. Our technique can be performed by surgeons independently with a laptop and a Microsoft HoloLens, making CT angiography data more accessible and practical for use in plastic surgery. We demonstrate the first use of photorealistic rendering in Mixed Reality to explore perforator anatomy. No Level Assigned This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.


  • HoloDIEP—Faster and More Accurate Intraoperative DIEA Perforator Mapping Using a Novel Mixed Reality Tool

    by Fabian N. Necker, David J. Cholok, Marc J. Fischer, Mohammed S. Shaheen, Kyle Gifford, Michael Januszyk, Christoph W. Leuze, Michael Scholz, Bruce L. Daniel, Arash Momeni

    Background Microsurgical breast reconstruction using abdominal tissue is a complex procedure, in part, due to variable vascular/perforator anatomy. Preoperative computed tomography angiography (CTA) has mitigated this challenge to some degree; yet it continues to pose certain challenges. The ability to map perforators with Mixed Reality has been demonstrated in case studies, but its accuracy has not been studied intraoperatively. Here, we compare the accuracy of “HoloDIEP” in identifying perforator location (vs. Doppler ultrasound) by using holographic 3D models derived from preoperative CTA. Methods Using a custom application on HoloLens, the deep inferior epigastric artery vascular tree was traced in 15 patients who underwent microsurgical breast reconstruction. Perforator markings were compared against the 3D model in a coordinate system centered on the umbilicus. Holographic- and Doppler-identified markings were compared using a perspective-corrected photo technique against the 3D model along with measurement of duration of perforator mapping for each technique. Results Vascular points in HoloDIEP skin markings were −0.97 ± 6.2 mm (perforators: −0.62 ± 6.13 mm) away from 3D-model ground-truth in radial length from the umbilicus at a true distance of 10.81 ± 6.14 mm (perforators: 11.40 ± 6.15 mm). Absolute difference in radial distance was twice as high for Doppler markings compared with Holo-markings (9.71 ± 6.16 and 4.02 ± 3.20 mm, respectively). Only in half of all cases (7/14), more than 50% of the Doppler-identified points were reasonably close (<30 mm) to 3D-model ground-truth. HoloDIEP was twice as fast as Doppler ultrasound (76.9s vs. 150.4 s per abdomen). Conclusion HoloDIEP allows for faster and more accurate intraoperative perforator mapping than Doppler ultrasound.


  • Open Access

    Interactive Shape Sonification for Tumor Localization in Breast Cancer Surgery

    by Laura Schütz, Trishia El Chemaly, Emmanuelle Weber, Anh Thien Doan, Jacqueline Tsai, Christoph Leuze, Bruce Daniel, Nassir Navab

    About 20 percent of patients undergoing breast-conserving surgery require reoperation due to cancerous tissue remaining inside the breast. Breast cancer localization systems utilize auditory feedback to convey the distance between a localization probe and a small marker (seed) implanted into the breast tumor prior to surgery. However, no information on the location of the tumor margin is provided. To reduce the reoperation rate by improving the usability and accuracy of the surgical task, we developed an auditory display using shape sonification to assist with tumor margin localization. Accuracy and usability of the interactive shape sonification were determined on models of the female breast in three user studies with both breast surgeons and non-clinical participants. The comparative studies showed a significant increase in usability (p<0.05) and localization accuracy (p<0.001) of the shape sonification over the auditory feedback currently used in surgery.


  • Open Access

    An orexigenic subnetwork within the human hippocampus

    by Daniel A. N. Barbosa, Sandra Gattas, Juliana S. Salgado, Fiene Marie Kuijper, Allan R. Wang, Yuhao Huang, Bina Kakusa, Christoph Leuze, Artur Luczak, Paul Rapp, et al.

    Only recently have more specific circuit-probing techniques become available to inform previous reports implicating the rodent hippocampus in orexigenic appetitive processing1–4. This function has been reported to be mediated at least in part by lateral hypothalamic inputs, including those involving orexigenic lateral hypothalamic neuropeptides, such as melanin-concentrating hormone5,6. This circuit, however, remains elusive in humans. Here we combine tractography, intracranial electrophysiology, cortico-subcortical evoked potentials, and brain-clearing 3D histology to identify an orexigenic circuit involving the lateral hypothalamus and converging in a hippocampal subregion. We found that low-frequency power is modulated by sweet-fat food cues, and this modulation was specific to the dorsolateral hippocampus. Structural and functional analyses of this circuit in a human cohort exhibiting dysregulated eating behaviour revealed connectivity that was inversely related to body mass index. Collectively, this multimodal approach describes an orexigenic subnetwork within the human hippocampus implicated in obesity and related eating disorders.