Ye Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ye Xu has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Tian Han
Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
7 shared publications- Xingtao Zhou
Eye Institute and Department of Ophthalmology Eye & ENT Hospital, Fudan University Shanghai China
6 shared publications Yang Shen
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
4 shared publicationsYangyi Huang
Department of Ophthalmology, Eye Institute, Eye & ENT Hospital, Fudan University, Shanghai, China
4 shared publicationsYuliang Wang
Department of Ophthalmology, Eye Institute, Eye & ENT Hospital, Fudan University, Shanghai, China
3 shared publicationsJifang Wang
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
2 shared publications
Latest Publications
- 10 March 2026
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 46 (2) , 331-336
A Comparative Clinical Study of 0.50% Versus 0.75% Pilocarpine Eye Drops for Improving Visual Performance in Presbyopia
Objective To compare the efficacy and safety of 0.50% and 0.75% pilocarpine ophthalmic solutions for treating presbyopia. Methods In this prospective study, 22 presbyopic subjects (44 eyes) were assigned to use 0.50% or 0.75% pilocarpine bilaterally, once daily for 2 weeks. Primary outcomes included distance-corrected intermediate visual acuity (DCIVA) at 66 cm and distance-corrected near visual acuity (DCNVA) at 40 cm under photopic and mesopic conditions, pupil size, refractive error, intraocular pressure (IOP) and patient-reported adverse events. Assessments were conducted at baseline, day 1 (after 1 and 6 h) and week 2 (after 1 h). Results No serious adverse events occurred. Neither formulation affected IOP or refractive error significantly. Pupil constriction was greater in the 0.75% group than the 0.50% group (2.8 ± 1.1 vs. 2.0 ± 0.8 mm, p = 0.02). After 2 weeks, the gain in photopic DCNVA was 0.18 logMAR for both concentrations (p = 0.70). The respective gain in visual acuity measures for the 0.75% and 0.50% groups was: mesopic DCNVA, 0.14 and 0.19 logMAR (p = 0.25); photopic DCIVA, 0.14 and 0.09 logMAR (p = 0.02); mesopic DCIVA, 0.12 and 0.10 logMAR (p = 0.18). Conclusion Both 0.50% and 0.75% pilocarpine improved visual performance in presbyopia significantly, suggesting it is a promising treatment option. Clinical trial registration Chinese Clinical Trial Registry (ChiCTR), 2023/3/2, No.ChiCTR2300068971.
- 10 March 2026
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 46 (2) , 331-336
A Comparative Clinical Study of 0.50% Versus 0.75% Pilocarpine Eye Drops for Improving Visual Performance in Presbyopia
Objective To compare the efficacy and safety of 0.50% and 0.75% pilocarpine ophthalmic solutions for treating presbyopia. Methods In this prospective study, 22 presbyopic subjects (44 eyes) were assigned to use 0.50% or 0.75% pilocarpine bilaterally, once daily for 2 weeks. Primary outcomes included distance-corrected intermediate visual acuity (DCIVA) at 66 cm and distance-corrected near visual acuity (DCNVA) at 40 cm under photopic and mesopic conditions, pupil size, refractive error, intraocular pressure (IOP) and patient-reported adverse events. Assessments were conducted at baseline, day 1 (after 1 and 6 h) and week 2 (after 1 h). Results No serious adverse events occurred. Neither formulation affected IOP or refractive error significantly. Pupil constriction was greater in the 0.75% group than the 0.50% group (2.8 ± 1.1 vs. 2.0 ± 0.8 mm, p = 0.02). After 2 weeks, the gain in photopic DCNVA was 0.18 logMAR for both concentrations (p = 0.70). The respective gain in visual acuity measures for the 0.75% and 0.50% groups was: mesopic DCNVA, 0.14 and 0.19 logMAR (p = 0.25); photopic DCIVA, 0.14 and 0.09 logMAR (p = 0.02); mesopic DCIVA, 0.12 and 0.10 logMAR (p = 0.18). Conclusion Both 0.50% and 0.75% pilocarpine improved visual performance in presbyopia significantly, suggesting it is a promising treatment option. Clinical trial registration Chinese Clinical Trial Registry (ChiCTR), 2023/3/2, No.ChiCTR2300068971.
- 7 October 2024
- Published by Springer Nature in Lasers in Medical Science
- Vol. 39 (1) , 1-6
Seven-year refractive outcomes comparing small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis for myopia and myopic astigmatism
This study aimed to compare the seven-year refractive outcomes of small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of myopia and myopic astigmatism. This retrospective cohort study included 97 eyes of 53 patients who had undergone SMILE or FS-LASIK for myopia seven years prior. Measured parameters included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and manifest refraction. There were no significant differences between the SMILE and FS-LASIK groups in logMAR UDVA, cylinder, and logMAR CDVA at 7 years postoperatively (P>0.05). However, there were significant differences between the two groups in sphere and spherical equivalent (P=0.035 and P=0.016, respectively). UDVA was better than or equal to 20/20 in 81% of the eyes after SMILE and in 63% after FS-LASIK (P = 0.045). The efficacy indices of the SMILE and FS-LASIK groups were 1.04 ± 0.23 and 0.97 ± 0.23 (P=0.405), and the safety indices were 1.18 ± 0.19 and 1.10 ± 0.17 (P=0.543), respectively. This study demonstrates the good predictivity of both SMILE and FS-LASIK. SMILE could offer superior refractive outcomes than FS-LASIK during a 7-year follow-up in correcting myopia and myopic astigmatism.
- 7 October 2024
- Published by Springer Nature in Lasers in Medical Science
- Vol. 39 (1) , 1-6
Seven-year refractive outcomes comparing small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis for myopia and myopic astigmatism
This study aimed to compare the seven-year refractive outcomes of small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of myopia and myopic astigmatism. This retrospective cohort study included 97 eyes of 53 patients who had undergone SMILE or FS-LASIK for myopia seven years prior. Measured parameters included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and manifest refraction. There were no significant differences between the SMILE and FS-LASIK groups in logMAR UDVA, cylinder, and logMAR CDVA at 7 years postoperatively (P>0.05). However, there were significant differences between the two groups in sphere and spherical equivalent (P=0.035 and P=0.016, respectively). UDVA was better than or equal to 20/20 in 81% of the eyes after SMILE and in 63% after FS-LASIK (P = 0.045). The efficacy indices of the SMILE and FS-LASIK groups were 1.04 ± 0.23 and 0.97 ± 0.23 (P=0.405), and the safety indices were 1.18 ± 0.19 and 1.10 ± 0.17 (P=0.543), respectively. This study demonstrates the good predictivity of both SMILE and FS-LASIK. SMILE could offer superior refractive outcomes than FS-LASIK during a 7-year follow-up in correcting myopia and myopic astigmatism.
- Open Access
- 3 September 2024
- Published by Springer Nature in BMC Ophthalmology
- Vol. 24 (1) , 1-10
Comparison of long-term changes in the effective optical zone following SMILE and FS-LASIK for moderate and high myopia
Visual quality after corneal refractive surgery is linked to the postoperative effective optical zone (EOZ). This study aims to compare long-term changes in the EOZ following small incision lenticule extraction (SMILE) and femtosecond laser-assisted in-situ keratomileusis (FS-LASIK) for moderate and high myopia. This study included 42 patients (72 eyes) who underwent either SMILE (36 eyes) or FS-LASIK (36 eyes). A custom software program based on the tangential curvature difference map of the Pentacam HR (Oculus Optikgeräte GmbH) was used to define the EOZ at 3 and 7 years postoperatively. The EOZ, its chronological changes compared to the programmed optical zone (POZ), and the corneal wavefront aberrations following SMILE and FS-LASIK were analyzed. Correlations between the EOZ changes and relevant parameters were evaluated. Three years postoperatively, EOZ following SMILE and FS-LASIK were 5.13 ± 0.27 mm and 4.70 ± 0.24 mm (P < 0.001), respectively. Seven years postoperatively, EOZ following SMILE and FS-LASIK decreased to 5.03 ± 0.28 mm and 4.63 ± 0.23 mm (P < 0.001), respectively. At postoperative 7 years, the percentages of EOZ/POZ were negatively correlated with Q-value changes (β = -5.120, P = 0.009) following SMILE and positively correlated with the cylinder correction (β = 1.184, P = 0.004) following FS-LASIK. The induced spherical aberrations in the SMILE group were less than those in the FS-LASIK group (P < 0.05) and were negatively correlated with the EOZ/POZ (β = -16.653, P < 0.001). The EOZ following SMILE was larger than that following FS-LASIK in the long postoperative term for moderate and high myopia. Furthermore, a continual reduction in the EOZ was noted after both surgical modalities.
- 3 September 2024
- Published by Springer Nature in BMC Ophthalmology
- Vol. 24 (1) , 1-10
Open AccessComparison of long-term changes in the effective optical zone following SMILE and FS-LASIK for moderate and high myopia
Visual quality after corneal refractive surgery is linked to the postoperative effective optical zone (EOZ). This study aims to compare long-term changes in the EOZ following small incision lenticule extraction (SMILE) and femtosecond laser-assisted in-situ keratomileusis (FS-LASIK) for moderate and high myopia. This study included 42 patients (72 eyes) who underwent either SMILE (36 eyes) or FS-LASIK (36 eyes). A custom software program based on the tangential curvature difference map of the Pentacam HR (Oculus Optikgeräte GmbH) was used to define the EOZ at 3 and 7 years postoperatively. The EOZ, its chronological changes compared to the programmed optical zone (POZ), and the corneal wavefront aberrations following SMILE and FS-LASIK were analyzed. Correlations between the EOZ changes and relevant parameters were evaluated. Three years postoperatively, EOZ following SMILE and FS-LASIK were 5.13 ± 0.27 mm and 4.70 ± 0.24 mm (P < 0.001), respectively. Seven years postoperatively, EOZ following SMILE and FS-LASIK decreased to 5.03 ± 0.28 mm and 4.63 ± 0.23 mm (P < 0.001), respectively. At postoperative 7 years, the percentages of EOZ/POZ were negatively correlated with Q-value changes (β = -5.120, P = 0.009) following SMILE and positively correlated with the cylinder correction (β = 1.184, P = 0.004) following FS-LASIK. The induced spherical aberrations in the SMILE group were less than those in the FS-LASIK group (P < 0.05) and were negatively correlated with the EOZ/POZ (β = -16.653, P < 0.001). The EOZ following SMILE was larger than that following FS-LASIK in the long postoperative term for moderate and high myopia. Furthermore, a continual reduction in the EOZ was noted after both surgical modalities.
- Open Access
- 22 February 2024
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 12, 1352759
Algorithmic and sensor-based research on Chinese children’s and adolescents’ screen use behavior and light environment
Background: Myopia poses a global health concern and is influenced by both genetic and environmental factors. The incidence of myopia tends to increase during infectious outbreaks, such as the COVID-19 pandemic. This study examined the screen-time behaviors among Chinese children and adolescents and investigated the efficacy of artificial intelligence (AI)-based alerts in modifying screen-time practices.Methods: A cross-sectional analysis was performed using data from 6,716 children and adolescents with AI-enhanced tablets that monitored and recorded their behavior and environmental light during screen time.Results: The median daily screen time of all participants was 58.82 min. Among all age groups, elementary-school students had the longest median daily screen time, which was 87.25 min and exceeded 4 h per week. Children younger than 2 years engaged with tablets for a median of 41.84 min per day. Learning accounted for 54.88% of participants’ screen time, and 51.03% (3,390/6,643) of the participants used tablets for 1 h at an average distance p < 0.05).Conclusion: Young children are increasingly using digital screens, with school-age children and adolescents showing longer screen time than preschoolers. The study highlighted inadequate lighting conditions during screen use. AI alerts proved effective in prompting users to correct their screen-related behavior promptly.
- 22 February 2024
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 12, 1352759
Open AccessAlgorithmic and sensor-based research on Chinese children’s and adolescents’ screen use behavior and light environment
Background: Myopia poses a global health concern and is influenced by both genetic and environmental factors. The incidence of myopia tends to increase during infectious outbreaks, such as the COVID-19 pandemic. This study examined the screen-time behaviors among Chinese children and adolescents and investigated the efficacy of artificial intelligence (AI)-based alerts in modifying screen-time practices.Methods: A cross-sectional analysis was performed using data from 6,716 children and adolescents with AI-enhanced tablets that monitored and recorded their behavior and environmental light during screen time.Results: The median daily screen time of all participants was 58.82 min. Among all age groups, elementary-school students had the longest median daily screen time, which was 87.25 min and exceeded 4 h per week. Children younger than 2 years engaged with tablets for a median of 41.84 min per day. Learning accounted for 54.88% of participants’ screen time, and 51.03% (3,390/6,643) of the participants used tablets for 1 h at an average distance p < 0.05).Conclusion: Young children are increasingly using digital screens, with school-age children and adolescents showing longer screen time than preschoolers. The study highlighted inadequate lighting conditions during screen use. AI alerts proved effective in prompting users to correct their screen-related behavior promptly.
- Open Access
- 15 September 2023
- Published by Springer Nature in Research Square
Big data-based artificial intelligence for efficient digital screen usage management among Chinese children and adolescents during the COVID-19 pandemic
This study investigated screen-time behaviors of Chinese children and adolescents and the efficacy of artificial intelligence (AI)-based alerts in screen-time behavior correction. Data from 6,716 children and adolescents with AI-enhanced tablets that recorded behavioral and light environment data during use were analyzed. The mean daily screen time was 67.10 ± 48.26 min. The screen time of junior-high-school students exceeded 1.5 h (92.50 ± 75.06 min) and that of school-aged participants exceeded 4 h per week. Children younger than two years used tablets for more than 45 min per day. Learning accounted for more than 50% of participants’ screen time. The distance alarm was triggered 807,355 times. Some participants (31.03%, 2061/6643) used tablets for 1 h at an average distance < 50 cm. Over 70% of the participants used the tablet under an illuminance < 300 lx during the day and more than 60% under an illuminance < 100 lx at night. More than 85% of the participants’ ambient light exceeded 4,000 K color temperature at night. The screen time of school-aged participants was longer than that of preschool-aged children. The recorded illumination was insufficient and was paired with a high color temperature at night. AI can effectively remind children and adolescents to correct unhealthy behaviors during screen time.
- 15 September 2023
- Published by Springer Nature in Research Square
Open AccessBig data-based artificial intelligence for efficient digital screen usage management among Chinese children and adolescents during the COVID-19 pandemic
This study investigated screen-time behaviors of Chinese children and adolescents and the efficacy of artificial intelligence (AI)-based alerts in screen-time behavior correction. Data from 6,716 children and adolescents with AI-enhanced tablets that recorded behavioral and light environment data during use were analyzed. The mean daily screen time was 67.10 ± 48.26 min. The screen time of junior-high-school students exceeded 1.5 h (92.50 ± 75.06 min) and that of school-aged participants exceeded 4 h per week. Children younger than two years used tablets for more than 45 min per day. Learning accounted for more than 50% of participants’ screen time. The distance alarm was triggered 807,355 times. Some participants (31.03%, 2061/6643) used tablets for 1 h at an average distance < 50 cm. Over 70% of the participants used the tablet under an illuminance < 300 lx during the day and more than 60% under an illuminance < 100 lx at night. More than 85% of the participants’ ambient light exceeded 4,000 K color temperature at night. The screen time of school-aged participants was longer than that of preschool-aged children. The recorded illumination was insufficient and was paired with a high color temperature at night. AI can effectively remind children and adolescents to correct unhealthy behaviors during screen time.
- 12 August 2023
- Published by Springer Nature in Lasers in Medical Science
- Vol. 38 (1) , 1-6
Seven-year corneal densitometry changes after small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis
This study aims to investigate the 7-year changes in corneal densitometry (CD) after small incision lenticule extraction (SMILE) and femtosecond laser-assisted in situ keratomileusis (FS-LASIK). Forty-two eyes undergoing SMILE and thirty-one undergoing FS-LASIK were included in this retrospective study. CD was measured preoperatively and at 3 and 7 years postoperatively. Three concentric radial zones (0–2, 2–6, and 6–10 mm) of three different corneal depths (anterior 120 μm, posterior 60 μm, and central layer) were analyzed. In all three zones of the three corneal layers, no significant difference in CD was found between the two groups preoperatively and at 3 and 7 years postoperatively (all P > 0.05). All CD values in the three zones of the anterior and central layers significantly declined at 3 years postoperatively (all P < 0.001), and then increased at 7 years postoperatively compared to corresponding 3-year values (all P < 0.01). In the posterior layer, CD values in the 0–2-mm and 2–6-mm zones decreased at 3 years postoperatively (all P < 0.01) and continued to decrease at 7 years postoperatively (all P < 0.01). Similar CD trends were observed after SMILE and FS-LASIK. Posterior layer CD showed a decrease throughout the study period. In the anterior and central layers, CD values decreased and then increased at 7 years postoperatively. The transparency changes might have been due to age-related three-dimensional growth of collagen fibers and wound-healing reactions.
- 12 August 2023
- Published by Springer Nature in Lasers in Medical Science
- Vol. 38 (1) , 1-6
Seven-year corneal densitometry changes after small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis
This study aims to investigate the 7-year changes in corneal densitometry (CD) after small incision lenticule extraction (SMILE) and femtosecond laser-assisted in situ keratomileusis (FS-LASIK). Forty-two eyes undergoing SMILE and thirty-one undergoing FS-LASIK were included in this retrospective study. CD was measured preoperatively and at 3 and 7 years postoperatively. Three concentric radial zones (0–2, 2–6, and 6–10 mm) of three different corneal depths (anterior 120 μm, posterior 60 μm, and central layer) were analyzed. In all three zones of the three corneal layers, no significant difference in CD was found between the two groups preoperatively and at 3 and 7 years postoperatively (all P > 0.05). All CD values in the three zones of the anterior and central layers significantly declined at 3 years postoperatively (all P < 0.001), and then increased at 7 years postoperatively compared to corresponding 3-year values (all P < 0.01). In the posterior layer, CD values in the 0–2-mm and 2–6-mm zones decreased at 3 years postoperatively (all P < 0.01) and continued to decrease at 7 years postoperatively (all P < 0.01). Similar CD trends were observed after SMILE and FS-LASIK. Posterior layer CD showed a decrease throughout the study period. In the anterior and central layers, CD values decreased and then increased at 7 years postoperatively. The transparency changes might have been due to age-related three-dimensional growth of collagen fibers and wound-healing reactions.
- Open Access
- 1 December 2022
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 10, 1030458
Predictive models for IOPs measured with NCT, GAT, and ORA among patients undergoing SMILE
Purpose: To develop predictive models for the intraocular pressure (IOP) of patients undergoing small incision lenticule extraction (SMILE) procedures, measured with a noncontact tonometer (NCT), Goldmann applanation tonometry (GAT), and an ocular response analyzer (ORA).Methods: In this prospective study, a total of 104 eyes (−6.23 ± 2.06 diopters) of 52 patients (24.38 ± 4.76 years) undergoing SMILE procedures were included. The intraocular pressure was measured (IOPNCT with NCT, IOPGAT with GAT, and IOPcc and IOPg with ORA) before surgery and at postoperative 6 months. Information on age, preoperative and attempted spherical equivalent (SE), ablation depth, preoperative values and postoperative changes in central corneal thickness (CCT), K1, K2, Km, corneal hysteresis (CH) and corneal resistance factor (CRF) values was collected in order to predict IOPs.Results: All surgeries were uneventful. At postoperative 6 months, the efficacy and safety index were 1.04 ± 0.15 and 1.08 ± 0.18, respectively. Significant decreases were detected in postoperative IOPNCT, IOPGAT, IOPcc, and IOPg compared to preoperative values (all p < 0.001). No relationship was found between any IOP and ablation depth, attempted SE, and preoperative SE, as well as CCTdifference (all p > 0.05). Predictive models for IOPs were constructed to predict preoperative values, and R2 values were 67.5% (IOPNCT), 64.5% (IOPGAT), 78.7% (IOPcc), and 82.0% (IOPg). The prediction band of IOPNCT and IOPGAT was 7.4–15.1 mmHg and 8–16 mmHg, respectively.Conclusion: Predictive models for IOP measurements after SMILE procedures can be helpful in clinical practice.
- 1 December 2022
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 10, 1030458
Open AccessPredictive models for IOPs measured with NCT, GAT, and ORA among patients undergoing SMILE
Purpose: To develop predictive models for the intraocular pressure (IOP) of patients undergoing small incision lenticule extraction (SMILE) procedures, measured with a noncontact tonometer (NCT), Goldmann applanation tonometry (GAT), and an ocular response analyzer (ORA).Methods: In this prospective study, a total of 104 eyes (−6.23 ± 2.06 diopters) of 52 patients (24.38 ± 4.76 years) undergoing SMILE procedures were included. The intraocular pressure was measured (IOPNCT with NCT, IOPGAT with GAT, and IOPcc and IOPg with ORA) before surgery and at postoperative 6 months. Information on age, preoperative and attempted spherical equivalent (SE), ablation depth, preoperative values and postoperative changes in central corneal thickness (CCT), K1, K2, Km, corneal hysteresis (CH) and corneal resistance factor (CRF) values was collected in order to predict IOPs.Results: All surgeries were uneventful. At postoperative 6 months, the efficacy and safety index were 1.04 ± 0.15 and 1.08 ± 0.18, respectively. Significant decreases were detected in postoperative IOPNCT, IOPGAT, IOPcc, and IOPg compared to preoperative values (all p < 0.001). No relationship was found between any IOP and ablation depth, attempted SE, and preoperative SE, as well as CCTdifference (all p > 0.05). Predictive models for IOPs were constructed to predict preoperative values, and R2 values were 67.5% (IOPNCT), 64.5% (IOPGAT), 78.7% (IOPcc), and 82.0% (IOPg). The prediction band of IOPNCT and IOPGAT was 7.4–15.1 mmHg and 8–16 mmHg, respectively.Conclusion: Predictive models for IOP measurements after SMILE procedures can be helpful in clinical practice.
- Open Access
- 29 March 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 1-4
Corneal densitometry changes in a patient with interface fluid syndrome after small incision lenticule extraction
To report a case of interface fluid syndrome (IFS) following small incision lenticule extraction (SMILE) evaluated with corneal densitometry and optical coherence tomography (OCT). An 18-year-old man reported sudden vision loss 24 days after SMILE procedure. Intraocular pressure (IOP) was 36.3 mmHg (OD) and 36.7 mmHg (OS) by noncontact tonometry. Moderate corneal edema, interface fluid pocket and haze were observed by OCT and confirmed by corneal densitometry values. Discontinuation of steroids and addition of hypotensive medication were offered immediately. The symptoms were cured after the medication. Changes of corneal densitometry were consistent with the clinical course of IFS. This case illustrates that it is crucial to be aware that a history of SMILE can also cause IFS. Both OCT and corneal densitometry can serve as auxiliary means to evaluate the clinical course of IFS, and appropriate IOP management is an effective approach.
- 29 March 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 1-4
Open AccessCorneal densitometry changes in a patient with interface fluid syndrome after small incision lenticule extraction
To report a case of interface fluid syndrome (IFS) following small incision lenticule extraction (SMILE) evaluated with corneal densitometry and optical coherence tomography (OCT). An 18-year-old man reported sudden vision loss 24 days after SMILE procedure. Intraocular pressure (IOP) was 36.3 mmHg (OD) and 36.7 mmHg (OS) by noncontact tonometry. Moderate corneal edema, interface fluid pocket and haze were observed by OCT and confirmed by corneal densitometry values. Discontinuation of steroids and addition of hypotensive medication were offered immediately. The symptoms were cured after the medication. Changes of corneal densitometry were consistent with the clinical course of IFS. This case illustrates that it is crucial to be aware that a history of SMILE can also cause IFS. Both OCT and corneal densitometry can serve as auxiliary means to evaluate the clinical course of IFS, and appropriate IOP management is an effective approach.