Cyril Breque
Research Subjects
Research Interests
Cyril Breque has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Jean Pierre Faure
A B S Lab, UFR Medicine and Pharmacy, Poitiers Cedex 9, France
3 shared publications - Jérôme Danion
A B S Lab, UFR Medicine and Pharmacy, Poitiers Cedex 9, France
3 shared publications - Richer Jean-Pierre
A B S Lab, UFR Medicine and Pharmacy, Poitiers Cedex 9, France
3 shared publications - Juan Sandoval
Department of Mechanical Engineering and Complex Systems (GMSC), Pprime Institute French National Centre for Scientific Research (CNRS), National Higher School of Mechanics and Aeroengineering (ENSMA), University of Poitiers, UPR 3346 Poitiers, France
2 shared publications - Med Amine Laribi
University of Poitiers
2 shared publications - My-Van Nguyen
A B S Lab, UFR Medicine and Pharmacy, Poitiers Cedex 9, France
2 shared publications
Latest Publications
- Open Access
- 22 February 2023
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 45 (4) , 503
Correction to: Morphodynamic study of the corona mortis using the SimLife® technology
- 22 February 2023
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 45 (4) , 503
Open AccessCorrection to: Morphodynamic study of the corona mortis using the SimLife® technology
- 31 December 2022
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 45 (2) , 89-99
Morphodynamic study of the corona mortis using the SimLife® technology
Purpose Open book pelvic ring fractures are potentially life-threatening, due to their instability and major hemorrhage risk. During the open reduction and internal fixation, the pelvic approach remains a technical challenge, as the surgeon wants to prevent any iatrogenic damage of the vascular loop located in the retro-pubic area called corona mortis (CMOR). Recently, the cadaver perfused SimLife® technology has been developed to improve the surgeon training, out of the operating room. This study aimed to compare two models of cadaveric dissection, to assess the interest of the perfused SimLife® in providing dynamic aspect of anatomy in the identification of CMOR and its topography. Methods Twelve human cadaveric pelvises have been dissected, following two protocols. 12 hemi-pelvises of the dissections were performed without perfusion (Model A), whereas the 12 other hemi-pelvises have been prepared with the SimLife® pulsatile perfusion (Model B). The prevalence and morphologic parameters determined: length, diameter and distance between the CMOR and the pubic symphysis. Results The CMOR has been found in 66.67% of the cases. The length, the diameter, and the distance between the CMOR and the pubic symphysis were significantly higher in model B (respectively p = 0.029, p = 0.01, and p = 0.022). Conclusion These results suggest that the CMOR is easier to identify and to dissect with the SimLife® perfusion. As part of the surgical training of any trauma surgeon, this model could help him to keep in mind the CMOR topography, to improve the open book lesion management.
- 31 December 2022
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 45 (2) , 89-99
Morphodynamic study of the corona mortis using the SimLife® technology
Purpose Open book pelvic ring fractures are potentially life-threatening, due to their instability and major hemorrhage risk. During the open reduction and internal fixation, the pelvic approach remains a technical challenge, as the surgeon wants to prevent any iatrogenic damage of the vascular loop located in the retro-pubic area called corona mortis (CMOR). Recently, the cadaver perfused SimLife® technology has been developed to improve the surgeon training, out of the operating room. This study aimed to compare two models of cadaveric dissection, to assess the interest of the perfused SimLife® in providing dynamic aspect of anatomy in the identification of CMOR and its topography. Methods Twelve human cadaveric pelvises have been dissected, following two protocols. 12 hemi-pelvises of the dissections were performed without perfusion (Model A), whereas the 12 other hemi-pelvises have been prepared with the SimLife® pulsatile perfusion (Model B). The prevalence and morphologic parameters determined: length, diameter and distance between the CMOR and the pubic symphysis. Results The CMOR has been found in 66.67% of the cases. The length, the diameter, and the distance between the CMOR and the pubic symphysis were significantly higher in model B (respectively p = 0.029, p = 0.01, and p = 0.022). Conclusion These results suggest that the CMOR is easier to identify and to dissect with the SimLife® perfusion. As part of the surgical training of any trauma surgeon, this model could help him to keep in mind the CMOR topography, to improve the open book lesion management.
- Open Access
- 3 March 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (5) , 1398
Toward Optimal Learning of the Gesture in Laparoscopic Surgery: Methodology and Performance
Classical surgical education has to face both a forensic reality and a technical issue: to train a learner in more complex techniques in an increasingly short time. Moreover, surgical training is still based on an empirical hierarchical relationship in which learners must reproduce a sequence of actions in a situation of strong emotional pressure. However, the effectiveness of learning and its quality are linked to the emotional states in which learners find themselves. Among these emotions, epistemic confusion can be found that arises in complex learning situations where there is a cognitive imbalance related to the comprehension of the task, and which results from a rupture between the pre-established patterns of the learner and the new learning task. Although one knows that confusion can have a beneficial or a negative impact on learning, depending on whether it is well regulated or not, the factors that can influence it positively are still poorly understood. Thus, the objective of this experiment is to assess the impact of confusion on the learning of a surgical procedure in an augmented reality context and to determine if this impact varies according to the feedback given to the learners and according to the occurrence of disruptive events. Medical externs were recruited (N = 15) who were required to perform a suturing task on a simulator and whose performance was measured using a Motion Capture (MoCap) system. Even though the statistical analyzes did not allow a conclusion to be reached, the protocol already established makes it possible to consider a longer-term study that will allow (by increasing the number of sessions and the number of participants) more significant results to be obtained in order to develop new surgical learning protocols. This preliminary study opens a new field of research on the influence of epistemic emotions, and more particularly of confusion, which is likely to upset traditional surgical teaching, and is based on negative conditioning and strong emotions with negative valence as well as stress and coercion.
- 3 March 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (5) , 1398
Open AccessToward Optimal Learning of the Gesture in Laparoscopic Surgery: Methodology and Performance
Classical surgical education has to face both a forensic reality and a technical issue: to train a learner in more complex techniques in an increasingly short time. Moreover, surgical training is still based on an empirical hierarchical relationship in which learners must reproduce a sequence of actions in a situation of strong emotional pressure. However, the effectiveness of learning and its quality are linked to the emotional states in which learners find themselves. Among these emotions, epistemic confusion can be found that arises in complex learning situations where there is a cognitive imbalance related to the comprehension of the task, and which results from a rupture between the pre-established patterns of the learner and the new learning task. Although one knows that confusion can have a beneficial or a negative impact on learning, depending on whether it is well regulated or not, the factors that can influence it positively are still poorly understood. Thus, the objective of this experiment is to assess the impact of confusion on the learning of a surgical procedure in an augmented reality context and to determine if this impact varies according to the feedback given to the learners and according to the occurrence of disruptive events. Medical externs were recruited (N = 15) who were required to perform a suturing task on a simulator and whose performance was measured using a Motion Capture (MoCap) system. Even though the statistical analyzes did not allow a conclusion to be reached, the protocol already established makes it possible to consider a longer-term study that will allow (by increasing the number of sessions and the number of participants) more significant results to be obtained in order to develop new surgical learning protocols. This preliminary study opens a new field of research on the influence of epistemic emotions, and more particularly of confusion, which is likely to upset traditional surgical teaching, and is based on negative conditioning and strong emotions with negative valence as well as stress and coercion.
- Open Access
- 16 July 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (14) , 6534
Torque Reduction of a Reconfigurable Spherical Parallel Mechanism Based on Craniotomy Experimental Data
This paper deals with a robotic manipulator dedicated to craniotomy with a remote center of motion based on a Spherical Parallel Manipulator (SPM) architecture. The SPM is proposed to handle the drilling tool through the requested craniotomy Degrees of Freedom (DoF) with two rotations. The proposed architecture allows one degree of redundancy according to the total DoF. Thus, a first contribution of this work focuses on the experimental analysis of craniotomy surgery tasks. Secondly, its behavior is improved, taking advantage of the redundancy of the SPM using the spinning motion as a reconfiguration variable. The spinning angle modulation allows the reconfigurable manipulator to minimize its motor torques. A series of motion capture and force experimentations is performed for the analysis of the kinematic and force interaction characterizing Burr hole craniotomy procedures. Experimentations were carried out by a neurosurgeon on a human cadaver, ensuring highly realistic conditions.
- 16 July 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (14) , 6534
Open AccessTorque Reduction of a Reconfigurable Spherical Parallel Mechanism Based on Craniotomy Experimental Data
This paper deals with a robotic manipulator dedicated to craniotomy with a remote center of motion based on a Spherical Parallel Manipulator (SPM) architecture. The SPM is proposed to handle the drilling tool through the requested craniotomy Degrees of Freedom (DoF) with two rotations. The proposed architecture allows one degree of redundancy according to the total DoF. Thus, a first contribution of this work focuses on the experimental analysis of craniotomy surgery tasks. Secondly, its behavior is improved, taking advantage of the redundancy of the SPM using the spinning motion as a reconfiguration variable. The spinning angle modulation allows the reconfigurable manipulator to minimize its motor torques. A series of motion capture and force experimentations is performed for the analysis of the kinematic and force interaction characterizing Burr hole craniotomy procedures. Experimentations were carried out by a neurosurgeon on a human cadaver, ensuring highly realistic conditions.
- 3 July 2020
- Published by Springer Nature in Obesity Surgery
- Vol. 30 (11) , 4352-4358
Bariatric Surgical Simulation: Evaluation in a Pilot Study of SimLife, a New Dynamic Simulated Body Model
Background The demand for bariatric surgery is high and so is the need for training future bariatric surgeons. Bariatric surgery, as a technically demanding surgery, imposes a learning curve that may initially induce higher morbidity. In order to limit the clinical impact of this learning curve, a simulation preclinical training can be offered. The aim of the work was to assess the realism of a new cadaveric model for simulated bariatric surgery (sleeve and Roux in Y gastric bypass). Aim A face validation study of SimLife, a new dynamic cadaveric model of simulated body for acquiring operative skills by simulation. The objectives of this study are first of all to measure the realism of this model, the satisfaction of learners, and finally the ability of this model to facilitate a learning process. Methods SimLife technology is based on a fresh body (frozen/thawed) given to science associated to a patented technical module, which can provide pulsatile vascularization with simulated blood heated to 37 °C and ventilation. Results Twenty-four residents and chief residents from 3 French University Digestive Surgery Departments were enrolled in this study. Based on their evaluation, the overall satisfaction of the cadaveric model was rated as 8.52, realism as 8.91, anatomic correspondence as 8.64, and the model’s ability to be learning tool as 8.78. Conclusion The use of the SimLife model allows proposing a very realistic surgical simulation model to realistically train and objectively evaluate the performance of young surgeons.
- 3 July 2020
- Published by Springer Nature in Obesity Surgery
- Vol. 30 (11) , 4352-4358
Bariatric Surgical Simulation: Evaluation in a Pilot Study of SimLife, a New Dynamic Simulated Body Model
Background The demand for bariatric surgery is high and so is the need for training future bariatric surgeons. Bariatric surgery, as a technically demanding surgery, imposes a learning curve that may initially induce higher morbidity. In order to limit the clinical impact of this learning curve, a simulation preclinical training can be offered. The aim of the work was to assess the realism of a new cadaveric model for simulated bariatric surgery (sleeve and Roux in Y gastric bypass). Aim A face validation study of SimLife, a new dynamic cadaveric model of simulated body for acquiring operative skills by simulation. The objectives of this study are first of all to measure the realism of this model, the satisfaction of learners, and finally the ability of this model to facilitate a learning process. Methods SimLife technology is based on a fresh body (frozen/thawed) given to science associated to a patented technical module, which can provide pulsatile vascularization with simulated blood heated to 37 °C and ventilation. Results Twenty-four residents and chief residents from 3 French University Digestive Surgery Departments were enrolled in this study. Based on their evaluation, the overall satisfaction of the cadaveric model was rated as 8.52, realism as 8.91, anatomic correspondence as 8.64, and the model’s ability to be learning tool as 8.78. Conclusion The use of the SimLife model allows proposing a very realistic surgical simulation model to realistically train and objectively evaluate the performance of young surgeons.
- Open Access
- 1 May 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (sup1) , S132-S134
The torsion of tibial tuberosity, a new factor of patellar instability
- 1 May 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (sup1) , S132-S134
Open AccessThe torsion of tibial tuberosity, a new factor of patellar instability
- Open Access
- 23 March 2017
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 4 (1) , 9
Biomechanical cadaveric comparison of patellar ligament suture protected by a steel cable versus a synthetic cable
Purpose and hypothesis: Patellar ligament rupture is a rare disabling pathology requiring a surgical ligament suture protected by a frame. The gold standard is the steel cable, but its rigidity and the necessity of a surgical re-intervention for its removal render it unsatisfactory. The objective of this paper is to quantify the mechanical protection provided by the terylene® in comparison with steel. Twenty-four knees of 12 fresh frozen cadaveric subjects were divided into 2 homogeneous groups (terylene and steel) of 12 knees (mean age = 69.3 years). Proximal ligament repair was performed according to a three-tunnel transosseous reinsertion technique. Mechanical tests were performed in flexion to simulate movement of the knee. The interligament gap and the amplitude angulation of the knee were measured by a system of extensometer and optical goniometer. Mechanical analysis permitted calculation of flexion amplitude for a ligament gap of 1 and 2 mm taking as initial angle the adjusting angle of pretension of the protection frame. Study of deformations of frames was performed. Statistical analysis was performed with a Wilcoxon Mann Whitney test. There is no significant difference in protection of the ligament suture between the “terylene” and “steel” groups. Mean flexion amplitudes (mΔF) show no significant differences between the 2 groups for a distension of the suture of 1 mm (m ΔF terylene1 = 4.74 °; mΔF steel1 = 5.91°; p = 0.198) and 2 mm (mΔF terylene2 = 8.71°; mΔF steel2 = 10.41°; p = 0.114). Elastic deformation of terylene was significantly greater than that of steel (p = 0.0004). Suture protection of the patellar ligament by a terylene wire is not significantly different from that provided by steel frame. The elastic properties of terylene and absence of a need for re intervention to secure its removal lead us towards its use in acute ruptures of the patellar ligament. The main limits involve the properties of the chain extenders with no contraction/muscle shortening and partial dehydration of tendons and ligaments and the mean age of 69.3 years. Level 5.
- 23 March 2017
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 4 (1) , 9
Open AccessBiomechanical cadaveric comparison of patellar ligament suture protected by a steel cable versus a synthetic cable
Purpose and hypothesis: Patellar ligament rupture is a rare disabling pathology requiring a surgical ligament suture protected by a frame. The gold standard is the steel cable, but its rigidity and the necessity of a surgical re-intervention for its removal render it unsatisfactory. The objective of this paper is to quantify the mechanical protection provided by the terylene® in comparison with steel. Twenty-four knees of 12 fresh frozen cadaveric subjects were divided into 2 homogeneous groups (terylene and steel) of 12 knees (mean age = 69.3 years). Proximal ligament repair was performed according to a three-tunnel transosseous reinsertion technique. Mechanical tests were performed in flexion to simulate movement of the knee. The interligament gap and the amplitude angulation of the knee were measured by a system of extensometer and optical goniometer. Mechanical analysis permitted calculation of flexion amplitude for a ligament gap of 1 and 2 mm taking as initial angle the adjusting angle of pretension of the protection frame. Study of deformations of frames was performed. Statistical analysis was performed with a Wilcoxon Mann Whitney test. There is no significant difference in protection of the ligament suture between the “terylene” and “steel” groups. Mean flexion amplitudes (mΔF) show no significant differences between the 2 groups for a distension of the suture of 1 mm (m ΔF terylene1 = 4.74 °; mΔF steel1 = 5.91°; p = 0.198) and 2 mm (mΔF terylene2 = 8.71°; mΔF steel2 = 10.41°; p = 0.114). Elastic deformation of terylene was significantly greater than that of steel (p = 0.0004). Suture protection of the patellar ligament by a terylene wire is not significantly different from that provided by steel frame. The elastic properties of terylene and absence of a need for re intervention to secure its removal lead us towards its use in acute ruptures of the patellar ligament. The main limits involve the properties of the chain extenders with no contraction/muscle shortening and partial dehydration of tendons and ligaments and the mean age of 69.3 years. Level 5.