Ramón Cisterna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ramón Cisterna has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Andía
Department of Obstetrics and Gynaecology, Basurto University Hospital, Bilbao, 48013, Spain
2 shared publications - Miren Basaras
Department of Immunology, Microbiology and Parasitology, Medicine and Odontology Faculty, University of Basque Country (UPV/EHU), Sarriena auzoa, 48940, Leioa-Bizkaia, Spain.
2 shared publications - Nerea Fontecha
Department of Immunology, Microbiology and Parasitology, Medicine and Odontology Faculty, University of Basque Country (UPV/EHU), Sarriena auzoa, 48940, Leioa-Bizkaia, Spain
2 shared publications - María Carmen Nieto Toboso
Clinical microbiology service. Bilbao, Basurto University Hospital, Basque Country, Spain
1 shared publication - Silvia Hernáez
Servicio de Microbiología, Hospital Universitario de Álava (HUA), 01009 Álava, Spain
1 shared publication
Latest Publications
- Open Access
- 9 March 2017
- Published by Springer Nature in Virology Journal
- Vol. 14 (1) , 1-7
RNA extraction method is crucial for human papillomavirus E6/E7 oncogenes detection
Human papillomavirus (HPV) DNA testing plays a main role in the management of cervical cancer, however to improve the specificity in cervical screening, there is a need to develop and validate different approaches that can identify women at risk for progressive disease. Nowadays, mRNA expression of viral E6 and E7 HPV oncogenes stands up as a potential biomarker to improve cervical screening. We aimed to validate a method for RNA extraction, detect HPV mRNA expression and, assess the relationship between E6/E7 mRNA expression and pathology of patients’ lesions and progression. This study included 50 specimens that had been previously genotyped as HPV16, 18, 31, 33 and/or 45. Cervical swabs were extracted with three different RNA extraction methods -Nuclisens manual extraction kit (bioMérieux), High Pure Viral RNA Kit (Roche) and RNeasy Plus Mini kit (Qiagen)-, and mRNA was detected with NucliSens EasyQ HPV version 1 test (bioMérieux) afterwards. Association of oncogene expression with pathology and lesion progression was analyzed for each extraction method. E6/E7 mRNA positivity rate was higher in samples analyzed with bioMérieux (62%), followed by Roche (24%) and Qiagen (6%). Women with lesions and lesion progression showed a higher prevalence of viral RNA expression than women that had not lesions or with lesion persistence. While bioMérieux revealed a higher sensitivity (77.27%), Roche presented a higher PPV (75%) and an increased specificity (89.28%). Extraction methods based on magnetic beads provided better RNA yield than those based in columns. Both Nuclisens manual extraction kit (bioMérieux) and High Pure Viral RNA Kit (Roche) seemed to be adequate for E6/E7 mRNA detection. However, none of them revealed both high sensitivity and specificity values. Further studies are needed to obtain and validate a standard gold method for RNA expression detection, to be included as part of the routine cervical screening program.
- 9 March 2017
- Published by Springer Nature in Virology Journal
- Vol. 14 (1) , 1-7
Open AccessRNA extraction method is crucial for human papillomavirus E6/E7 oncogenes detection
Human papillomavirus (HPV) DNA testing plays a main role in the management of cervical cancer, however to improve the specificity in cervical screening, there is a need to develop and validate different approaches that can identify women at risk for progressive disease. Nowadays, mRNA expression of viral E6 and E7 HPV oncogenes stands up as a potential biomarker to improve cervical screening. We aimed to validate a method for RNA extraction, detect HPV mRNA expression and, assess the relationship between E6/E7 mRNA expression and pathology of patients’ lesions and progression. This study included 50 specimens that had been previously genotyped as HPV16, 18, 31, 33 and/or 45. Cervical swabs were extracted with three different RNA extraction methods -Nuclisens manual extraction kit (bioMérieux), High Pure Viral RNA Kit (Roche) and RNeasy Plus Mini kit (Qiagen)-, and mRNA was detected with NucliSens EasyQ HPV version 1 test (bioMérieux) afterwards. Association of oncogene expression with pathology and lesion progression was analyzed for each extraction method. E6/E7 mRNA positivity rate was higher in samples analyzed with bioMérieux (62%), followed by Roche (24%) and Qiagen (6%). Women with lesions and lesion progression showed a higher prevalence of viral RNA expression than women that had not lesions or with lesion persistence. While bioMérieux revealed a higher sensitivity (77.27%), Roche presented a higher PPV (75%) and an increased specificity (89.28%). Extraction methods based on magnetic beads provided better RNA yield than those based in columns. Both Nuclisens manual extraction kit (bioMérieux) and High Pure Viral RNA Kit (Roche) seemed to be adequate for E6/E7 mRNA detection. However, none of them revealed both high sensitivity and specificity values. Further studies are needed to obtain and validate a standard gold method for RNA expression detection, to be included as part of the routine cervical screening program.
- Open Access
- 5 November 2016
- Published by Springer Nature in BMC Cancer
- Vol. 16 (1) , 1-7
Assessment of human papillomavirus E6/E7 oncogene expression as cervical disease biomarker
The aims of this study were to detect HPV E6/E7 mRNA expression in women with high-risk genotypes (HPV-16, -18, -31, -33 and -45) analysing its relationship with tissue pathology and 2) 2-year follow-up of E6/E7 mRNA tested group. Our samples were genotyped and classified by pathologists according to Bethesda system. After RNA extraction, E6/E7 oncogene mRNA detection was performed by NucliSens® EasyQ® HPV v1 Test (bioMérieux). The results of the present study showed that E6/E7 mRNA positivity rate was 68.29 % in women tested once and 69.56 % in women tested twice. According to tissue pathology, all samples with high-grade lesions were positive for mRNA. Among women with low-grade lesions varied over the years from 89.28 to 84 % in women tested once and from 77.77 to 70 % in tested twice. Among women without lesion, positivity rate maintained in women tested once (from 50 to 41.38 %) and decreased in tested twice, from 63.63 to 44.44 %. Regarding lesion evolution, mRNA positivity was higher in women with lesion progression (53.13 %) and in women with positive results in two tested samples (83.33 %). HPV E6/E7 mRNA detection may be an effective screening test and biomarker for cervical cancer in women infected with these five genotypes. Nonetheless, further studies are needed to standardize as routine triage test.
- 5 November 2016
- Published by Springer Nature in BMC Cancer
- Vol. 16 (1) , 1-7
Open AccessAssessment of human papillomavirus E6/E7 oncogene expression as cervical disease biomarker
The aims of this study were to detect HPV E6/E7 mRNA expression in women with high-risk genotypes (HPV-16, -18, -31, -33 and -45) analysing its relationship with tissue pathology and 2) 2-year follow-up of E6/E7 mRNA tested group. Our samples were genotyped and classified by pathologists according to Bethesda system. After RNA extraction, E6/E7 oncogene mRNA detection was performed by NucliSens® EasyQ® HPV v1 Test (bioMérieux). The results of the present study showed that E6/E7 mRNA positivity rate was 68.29 % in women tested once and 69.56 % in women tested twice. According to tissue pathology, all samples with high-grade lesions were positive for mRNA. Among women with low-grade lesions varied over the years from 89.28 to 84 % in women tested once and from 77.77 to 70 % in tested twice. Among women without lesion, positivity rate maintained in women tested once (from 50 to 41.38 %) and decreased in tested twice, from 63.63 to 44.44 %. Regarding lesion evolution, mRNA positivity was higher in women with lesion progression (53.13 %) and in women with positive results in two tested samples (83.33 %). HPV E6/E7 mRNA detection may be an effective screening test and biomarker for cervical cancer in women infected with these five genotypes. Nonetheless, further studies are needed to standardize as routine triage test.