Stefan Studier-Fischer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stefan Studier-Fischer has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Felix Porschke
BG Trauma Center Ludwigshafen at Heidelberg University Hospital, Ludwigshafen, Germany
4 shared publications - Marc Schnetzke
Deutsches Gelenkzentrum, ATOS Klinik Heidelberg, Heidelberg, Deutschland
4 shared publications - Paul Alfred Gruetzner
BG Klinik Ludwigshafen, Department for Orthopaedics and Trauma Surgery at Heidelberg University, Ludwig-Guttmann-Str. 13, 67071 Ludwigshafen, Germany
4 shared publications - Thorsten Guehring
Department of Trauma and Orthopaedic Surgery, BG Trauma Center Ludwigshafen at the University of Heidelberg, Ludwigshafen on the Rhine, Germany
3 shared publications - Christel Weiss
Institute of Medical Statistics and Biomathematics, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
2 shared publications - Christoph Luecke
BG Trauma Center Ludwigshafen at Heidelberg University Hospital, Ludwigshafen, Germany
1 shared publication
Latest Publications
- 21 January 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 142 (11) , 3395-3403
Biomechanical analysis of the interval slide procedure: a fresh porcine cadaver study
Introduction The interval slide procedure (IS) has been introduced to improve mobility in massive, retracted rotator cuff tears. As clinical studies showed controversial results, the benefit of the IS is still widely discussed. Aim Aim of this study was to analyze the effect of IS procedure on tendon mobility in a fresh porcine cadaver model. Materials and methods In 30 fresh porcine cadaver shoulders with artificial supraspinatus defect tendon mobility was tested by measuring the load (in N) during tendon reduction to the footprint at the greater tubercle using a sensor enhanced arthroscopic grasper (t1). In intervention group (N = 15) anterior IS (t2), posterior IS (t3) and intraarticular capsule release (t4) were successively performed, each followed by tendon mobility assessment. Tendon mobility of the control group (N = 15) was measured in same time schedule without intervention. Results Mobility did not differ between groups for native tendons (CG 28.0 ± 11.2 N vs. IG 26.6 ± 11.6 N; P = 0.75). IS procedure significantly improves mobility at about 25.2% (t1 26.6 ± 11.6 N vs. t4 19.9 ± 12.3 N; P < 0.001) compared to the native tendon and 34.1% compared to CG (CG 30.2 ± 13.7 N vs. 19.9 ± 12.3 N; P = 0.026). In posthoc analyzes, anterior IS (P < 0.001) and capsule release (P = 0.005) significantly increased mobility, whereas the posterior IS did not (P = 0.778). Conclusion The IS procedure results in increased supraspinatus tendon mobility in fresh porcine cadaver shoulders. However, performing the posterior IS subsequent to the anterior IS no significant improvement of mobility has been observed.
- 21 January 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 142 (11) , 3395-3403
Biomechanical analysis of the interval slide procedure: a fresh porcine cadaver study
Introduction The interval slide procedure (IS) has been introduced to improve mobility in massive, retracted rotator cuff tears. As clinical studies showed controversial results, the benefit of the IS is still widely discussed. Aim Aim of this study was to analyze the effect of IS procedure on tendon mobility in a fresh porcine cadaver model. Materials and methods In 30 fresh porcine cadaver shoulders with artificial supraspinatus defect tendon mobility was tested by measuring the load (in N) during tendon reduction to the footprint at the greater tubercle using a sensor enhanced arthroscopic grasper (t1). In intervention group (N = 15) anterior IS (t2), posterior IS (t3) and intraarticular capsule release (t4) were successively performed, each followed by tendon mobility assessment. Tendon mobility of the control group (N = 15) was measured in same time schedule without intervention. Results Mobility did not differ between groups for native tendons (CG 28.0 ± 11.2 N vs. IG 26.6 ± 11.6 N; P = 0.75). IS procedure significantly improves mobility at about 25.2% (t1 26.6 ± 11.6 N vs. t4 19.9 ± 12.3 N; P < 0.001) compared to the native tendon and 34.1% compared to CG (CG 30.2 ± 13.7 N vs. 19.9 ± 12.3 N; P = 0.026). In posthoc analyzes, anterior IS (P < 0.001) and capsule release (P = 0.005) significantly increased mobility, whereas the posterior IS did not (P = 0.778). Conclusion The IS procedure results in increased supraspinatus tendon mobility in fresh porcine cadaver shoulders. However, performing the posterior IS subsequent to the anterior IS no significant improvement of mobility has been observed.
- Open Access
- 13 August 2020
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (2) , 617-626
Mobility Assessment of the Supraspinatus in a Porcine Cadaver Model Using a Sensor-Enhanced, Arthroscopic Grasper
Tendon mobility is highly relevant in rotator cuff surgery. Objective data about rotator cuff mobility is rare. Tendon mobility still needs to be evaluated subjectively by the surgeon. This study aims to establish a porcine animal model for mobility analysis of the supraspinatus. In this context, we introduce a sensor-enhanced, arthroscopic grasper (SEAG) suitable for objective intraoperative measurements of tendon mobility in clinical praxis. Tendon mobility of 15 fresh porcine cadaver shoulders with artificial rotator cuff tears was evaluated using the SEAG. Mobility characteristics (load–displacement curves, maximum load, stiffness) were studied and inter- and intraobserver agreement (intraclass correlation coefficient (ICC)) were tested. Factors with a potential adverse effect (plastic deformation and rigor mortis) were also evaluated. All shoulders showed characteristic reproducible load–displacement curves with a nonlinear part at the start, followed by a linear part. Mean maximum load was 28.6 N ± 12.5. Mean stiffness was 6.0 N/mm ± 2.6. We found substantial interobserver agreement (ICC 0.672) and nearly perfect intraobserver agreement (0.944) for maximum load measurement. Inter- (0.021) and intraobserver (0.774) agreement for stiffness was lower. Plastic deformation and rigor mortis were excluded. The animal model demonstrates reliable and in vivo-like measurements of tendon mobility. The SEAG is a reliable tool for tendon mobility assessment.
- 13 August 2020
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (2) , 617-626
Open AccessMobility Assessment of the Supraspinatus in a Porcine Cadaver Model Using a Sensor-Enhanced, Arthroscopic Grasper
Tendon mobility is highly relevant in rotator cuff surgery. Objective data about rotator cuff mobility is rare. Tendon mobility still needs to be evaluated subjectively by the surgeon. This study aims to establish a porcine animal model for mobility analysis of the supraspinatus. In this context, we introduce a sensor-enhanced, arthroscopic grasper (SEAG) suitable for objective intraoperative measurements of tendon mobility in clinical praxis. Tendon mobility of 15 fresh porcine cadaver shoulders with artificial rotator cuff tears was evaluated using the SEAG. Mobility characteristics (load–displacement curves, maximum load, stiffness) were studied and inter- and intraobserver agreement (intraclass correlation coefficient (ICC)) were tested. Factors with a potential adverse effect (plastic deformation and rigor mortis) were also evaluated. All shoulders showed characteristic reproducible load–displacement curves with a nonlinear part at the start, followed by a linear part. Mean maximum load was 28.6 N ± 12.5. Mean stiffness was 6.0 N/mm ± 2.6. We found substantial interobserver agreement (ICC 0.672) and nearly perfect intraobserver agreement (0.944) for maximum load measurement. Inter- (0.021) and intraobserver (0.774) agreement for stiffness was lower. Plastic deformation and rigor mortis were excluded. The animal model demonstrates reliable and in vivo-like measurements of tendon mobility. The SEAG is a reliable tool for tendon mobility assessment.
- 31 March 2020
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 140 (8) , 1073-1079
Functional outcome and tendon integrity of rotator cuff reconstruction after primary traumatic glenohumeral dislocation
Introduction Rotator cuff tears (rct) subsequent to glenohumeral dislocation are relevant concomitant injuries, can lead to impaired shoulder function and increase risk of recurrent dislocation. Aim The aim of this study was to determine the functional outcome, recurrent dislocation rate and tendon integrity after rotator cuff repair after primary traumatic shoulder dislocation. Materials and methods In this retrospective case series, 23 patients (age 56.4 years ± 6.3) who underwent a rotator cuff reconstruction after primary traumatic shoulder dislocation with confirmed combination of full-thickness RCT and Bankart lesion were enrolled after a minimum follow-up of 2 years. Clinical outcome (age and gender adjusted Constant Murley Score (CMS), DASH, Rowe Score) (n = 23) and sonographic tendon integrity (n = 19) were studied. Results After a mean follow-up of 58 ± 32 months, a CMS of 85.1% ± 14.7, DASH of 14.2 ± 20.5, and Rowe Score of 82.4 ± 15.2 indicated good functional outcome. In 4 of 19 patients (21.1%) a re-tear was found during sonographic evaluation. In 3 cases (13%), a revision was performed (2 × stiff shoulder, 1 × postoperative infection). One patient had a single traumatic re-dislocation (4.3%). Conclusions Patients undergone reconstruction of the rotator cuff following a primary traumatic shoulder dislocation can achieve good functional results and a low rate of recurrent dislocation. Postoperative tendon integrity is comparable with known data about non traumatic tears.
- 31 March 2020
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 140 (8) , 1073-1079
Functional outcome and tendon integrity of rotator cuff reconstruction after primary traumatic glenohumeral dislocation
Introduction Rotator cuff tears (rct) subsequent to glenohumeral dislocation are relevant concomitant injuries, can lead to impaired shoulder function and increase risk of recurrent dislocation. Aim The aim of this study was to determine the functional outcome, recurrent dislocation rate and tendon integrity after rotator cuff repair after primary traumatic shoulder dislocation. Materials and methods In this retrospective case series, 23 patients (age 56.4 years ± 6.3) who underwent a rotator cuff reconstruction after primary traumatic shoulder dislocation with confirmed combination of full-thickness RCT and Bankart lesion were enrolled after a minimum follow-up of 2 years. Clinical outcome (age and gender adjusted Constant Murley Score (CMS), DASH, Rowe Score) (n = 23) and sonographic tendon integrity (n = 19) were studied. Results After a mean follow-up of 58 ± 32 months, a CMS of 85.1% ± 14.7, DASH of 14.2 ± 20.5, and Rowe Score of 82.4 ± 15.2 indicated good functional outcome. In 4 of 19 patients (21.1%) a re-tear was found during sonographic evaluation. In 3 cases (13%), a revision was performed (2 × stiff shoulder, 1 × postoperative infection). One patient had a single traumatic re-dislocation (4.3%). Conclusions Patients undergone reconstruction of the rotator cuff following a primary traumatic shoulder dislocation can achieve good functional results and a low rate of recurrent dislocation. Postoperative tendon integrity is comparable with known data about non traumatic tears.
- Open Access
- 12 February 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-7
Return to work after acromioclavicular joint stabilization: a retrospective case control study
Considering the epidemiology of acromioclavicular (AC) dislocation related to young and active patients, the impact on working capacity is highly relevant. The purpose of this study was to determine the capacity of work and time to return to work (RTW) after AC joint stabilization. We hypothesized that manual working patients show more restrictions returning to work. In this retrospective case series, pre- and posttraumatic working capacity of 54 patients (FU-rate 80.1%, FU time 23, range 18–45 month) stabilized in single TightRope technique was analyzed. Clinical outcome (DASH, Constant-Murley score) and complications were evaluated in addition. Fifty one of 54 patients (94.5%) were returned to work at final follow-up. The median time to return was 13 (5–143) weeks. Manual working patients showed lower RTW-rates (91.2% vs. 100%; p = .151), longer RTW-time (15.5 vs. 6 weeks; p = .008), and more often persistent shoulder symptoms at work (55.9% vs. 5%; p < .001). After stabilization of AC joint dislocation, the majority of patients returned to work, needing substantial time to return. Manual working patients required more time and often suffer under persistent symptoms at work.
- 12 February 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-7
Open AccessReturn to work after acromioclavicular joint stabilization: a retrospective case control study
Considering the epidemiology of acromioclavicular (AC) dislocation related to young and active patients, the impact on working capacity is highly relevant. The purpose of this study was to determine the capacity of work and time to return to work (RTW) after AC joint stabilization. We hypothesized that manual working patients show more restrictions returning to work. In this retrospective case series, pre- and posttraumatic working capacity of 54 patients (FU-rate 80.1%, FU time 23, range 18–45 month) stabilized in single TightRope technique was analyzed. Clinical outcome (DASH, Constant-Murley score) and complications were evaluated in addition. Fifty one of 54 patients (94.5%) were returned to work at final follow-up. The median time to return was 13 (5–143) weeks. Manual working patients showed lower RTW-rates (91.2% vs. 100%; p = .151), longer RTW-time (15.5 vs. 6 weeks; p = .008), and more often persistent shoulder symptoms at work (55.9% vs. 5%; p < .001). After stabilization of AC joint dislocation, the majority of patients returned to work, needing substantial time to return. Manual working patients required more time and often suffer under persistent symptoms at work.