Joy E. Gray-Munro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joy E. Gray-Munro has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Afrah Al Hegy
Dept. of Chemistry and Biochemistry, Laurentian University, Sudbury, Ontario, P3E 2C6, Canada
2 shared publicationsM. Strong
2 shared publicationsChristine Seguin
Department of Chemistry and Biochemistry, Laurentian University, Sudbury, Ontario, Canada P3E 2C6
1 shared publicationEric R. Gauthier
Dept. of Chemistry and Biochemistry, Laurentian University, Sudbury, Ontario, P3E 2C6, Canada
1 shared publication- Eric R. Gauthier
Department of Chemistry and Biochemistry, Laurentian University, Sudbury, Ontario, Canada
1 shared publication Michael Strong
Department of Chemistry and Biochemistry, Laurentian University, Sudbury, Ontario, Canada P3E 2C6
1 shared publication
Latest Publications
- Open Access
- 1 March 2020
- Published by KEAI Publishing in Bioactive Materials
- Vol. 5 (1) , 26-33
Investigation of a cyanine dye assay for the evaluation of the biocompatibility of magnesium alloys by direct and indirect methods
Magnesium and its alloys are promising candidates for a new generation of biodegradable metals in orthopaedic applications due to their excellent biocompatibility, biodegradability, and mechanical properties that are similar to natural bone. However, direct in vitro assessment of these materials in the presence of cells is complicated by degradation products from the alloy that lead to a false positive for the most commonly used cell adhesion and cell proliferation assays. In this paper, a cyanine dye was used to quantitatively evaluate the in vitro biocompatibility of a Mg AZ31 alloy by both direct and indirect methods. The cytotoxicity of the corrosion products was evaluated via an indirect method; a 25% decrease in cell viability compared to control samples was observed. Moreover, direct assessment of cell adhesion and proliferation showed a statistically significant increase in cell number at the surface after 72 h. In addition, the degradation rate and surface characteristics of the Mg AZ31 alloy were evaluated for both direct and indirect tests. The degradation rate was unaffected by the presence of cells while evidence of an increase in calcium phosphate deposition on the magnesium alloy surface in the presence of cells was observed. This study demonstrates that a cyanine dye based assay provides a more accurate assessment of the overall in vitro biocompatibility of biodegradable metals than the more commonly used assays reported in the literature to date.
- 1 March 2020
- Published by KEAI Publishing in Bioactive Materials
- Vol. 5 (1) , 26-33
Open AccessInvestigation of a cyanine dye assay for the evaluation of the biocompatibility of magnesium alloys by direct and indirect methods
Magnesium and its alloys are promising candidates for a new generation of biodegradable metals in orthopaedic applications due to their excellent biocompatibility, biodegradability, and mechanical properties that are similar to natural bone. However, direct in vitro assessment of these materials in the presence of cells is complicated by degradation products from the alloy that lead to a false positive for the most commonly used cell adhesion and cell proliferation assays. In this paper, a cyanine dye was used to quantitatively evaluate the in vitro biocompatibility of a Mg AZ31 alloy by both direct and indirect methods. The cytotoxicity of the corrosion products was evaluated via an indirect method; a 25% decrease in cell viability compared to control samples was observed. Moreover, direct assessment of cell adhesion and proliferation showed a statistically significant increase in cell number at the surface after 72 h. In addition, the degradation rate and surface characteristics of the Mg AZ31 alloy were evaluated for both direct and indirect tests. The degradation rate was unaffected by the presence of cells while evidence of an increase in calcium phosphate deposition on the magnesium alloy surface in the presence of cells was observed. This study demonstrates that a cyanine dye based assay provides a more accurate assessment of the overall in vitro biocompatibility of biodegradable metals than the more commonly used assays reported in the literature to date.
- Open Access
- 27 January 2017
- Published by KEAI Publishing in Bioactive Materials
- Vol. 2 (1) , 35-43
Influence of mixed organosilane coatings with variable RGD surface densities on the adhesion and proliferation of human osteosarcoma Saos-2 cells to magnesium alloy AZ31
In the last decade, the use of magnesium and its alloys as biodegradable implant materials has become increasingly accepted. However, surface modification of these materials to control the degradation rate in the early stages of healing and improve their biocompatibility is crucial to the successful implementation of magnesium alloy implants in medicine. Cell adhesion and proliferation at the implant surface is a vital factor for successful integration of a biomaterial within the body. Cells accomplish this task by binding to ligands such as the arginine-glycine-aspartic acid peptide sequence (RGD) commonly found on adhesive proteins present in the extracellular matrix. In this paper, we report a biomimetic surface modification strategy involving deposition of a mixed organosilane layer on Mg AZ31 followed by covalent immobilization of RGD peptides through a heterobifunctional cross-linker molecule. Our results indicate that with optimized deposition conditions uniform organosilane coatings were successfully deposited on the Mg AZ31 substrate. Furthermore, we have demonstrated that the surface density of immobilized RGD can be varied by depositing organosilane layers from solutions containing two different organosilanes in specified ratios. Increases in cell adhesion and cell proliferation were observed on the surface modified substrates.
- 27 January 2017
- Published by KEAI Publishing in Bioactive Materials
- Vol. 2 (1) , 35-43
Open AccessInfluence of mixed organosilane coatings with variable RGD surface densities on the adhesion and proliferation of human osteosarcoma Saos-2 cells to magnesium alloy AZ31
In the last decade, the use of magnesium and its alloys as biodegradable implant materials has become increasingly accepted. However, surface modification of these materials to control the degradation rate in the early stages of healing and improve their biocompatibility is crucial to the successful implementation of magnesium alloy implants in medicine. Cell adhesion and proliferation at the implant surface is a vital factor for successful integration of a biomaterial within the body. Cells accomplish this task by binding to ligands such as the arginine-glycine-aspartic acid peptide sequence (RGD) commonly found on adhesive proteins present in the extracellular matrix. In this paper, we report a biomimetic surface modification strategy involving deposition of a mixed organosilane layer on Mg AZ31 followed by covalent immobilization of RGD peptides through a heterobifunctional cross-linker molecule. Our results indicate that with optimized deposition conditions uniform organosilane coatings were successfully deposited on the Mg AZ31 substrate. Furthermore, we have demonstrated that the surface density of immobilized RGD can be varied by depositing organosilane layers from solutions containing two different organosilanes in specified ratios. Increases in cell adhesion and cell proliferation were observed on the surface modified substrates.
- 1 March 2013
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 393, 421-428
A study on the interfacial chemistry of magnesium hydroxide surfaces in aqueous phosphate solutions: Influence of Ca2+, Cl− and protein
- 1 March 2013
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 393, 421-428
A study on the interfacial chemistry of magnesium hydroxide surfaces in aqueous phosphate solutions: Influence of Ca2+, Cl− and protein
- 23 September 2008
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 91A (1) , 221-230
Influence of surface modification on the in vitro corrosion rate of magnesium alloy AZ31
In recent years, magnesium alloys have been proposed as a new class of metallic bioabsorbable implant material. Unfortunately, the production of hydrogen gas and an increase in alkalinity are both by‐products of the degradation process of these materials. This necessitates the development of magnesium alloys with controlled degradation rates. Furthermore, biocompatible coatings that can delay the onset of corrosion would ensure that the mechanical integrity of the implant remains intact in the early stages of healing. This article explores the influence of surface modification by biomimetic calcium phosphate coating, biodegradable polymer coatings, and acid etching on the corrosion rate of the AZ31 magnesium alloy in simulated body fluid. Our results indicate that all of these surface treatments have a positive impact on the corrosion rate of the material and that in the early stages of implantation it is possible to tailor the corrosion rate through an appropriate choice of surface treatment. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009
- 23 September 2008
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 91A (1) , 221-230
Influence of surface modification on the in vitro corrosion rate of magnesium alloy AZ31
In recent years, magnesium alloys have been proposed as a new class of metallic bioabsorbable implant material. Unfortunately, the production of hydrogen gas and an increase in alkalinity are both by‐products of the degradation process of these materials. This necessitates the development of magnesium alloys with controlled degradation rates. Furthermore, biocompatible coatings that can delay the onset of corrosion would ensure that the mechanical integrity of the implant remains intact in the early stages of healing. This article explores the influence of surface modification by biomimetic calcium phosphate coating, biodegradable polymer coatings, and acid etching on the corrosion rate of the AZ31 magnesium alloy in simulated body fluid. Our results indicate that all of these surface treatments have a positive impact on the corrosion rate of the material and that in the early stages of implantation it is possible to tailor the corrosion rate through an appropriate choice of surface treatment. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009
- 28 May 2008
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 90A (2) , 339-350
The mechanism of deposition of calcium phosphate coatings from solution onto magnesium alloy AZ31
In recent years, magnesium alloys have been proposed as a new class of metallic bioabsorbable implant material. Unfortunately, hydrogen gas evolution and an increase in alkalinity are both byproducts of the degradation process. This necessitates the development of magnesium alloys with controlled degradation rates. The development of biocompatible coatings that can delay the onset of corrosion is essential for improving the lifetime and performance of these materials in vivo. Calcium phosphate coatings have been shown to improve the biocompatibility of metallic implants for orthopedic applications. In this article, we report a solution chemistry technique for depositing calcium phosphate coatings on magnesium alloy surfaces. Our kinetic studies indicate that the deposition of the coating is related to the anodic dissolution of the substrate. Characterization of the coating by XPS, SEM/EDS, and XRD reveal that the coating produced is a poorly crystalline calcium magnesium hydroxyapatite material. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009
- 28 May 2008
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 90A (2) , 339-350
The mechanism of deposition of calcium phosphate coatings from solution onto magnesium alloy AZ31
In recent years, magnesium alloys have been proposed as a new class of metallic bioabsorbable implant material. Unfortunately, hydrogen gas evolution and an increase in alkalinity are both byproducts of the degradation process. This necessitates the development of magnesium alloys with controlled degradation rates. The development of biocompatible coatings that can delay the onset of corrosion is essential for improving the lifetime and performance of these materials in vivo. Calcium phosphate coatings have been shown to improve the biocompatibility of metallic implants for orthopedic applications. In this article, we report a solution chemistry technique for depositing calcium phosphate coatings on magnesium alloy surfaces. Our kinetic studies indicate that the deposition of the coating is related to the anodic dissolution of the substrate. Characterization of the coating by XPS, SEM/EDS, and XRD reveal that the coating produced is a poorly crystalline calcium magnesium hydroxyapatite material. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009