Christopher Dydula
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Christopher Dydula has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Paul C. Johns
Department of Physics, Carleton University , 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6, Canada
2 shared publications Andrew Bayley
Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON, Canada
1 shared publication- Angus Z. Lau
Sunnybrook Research Institute
1 shared publication Antoine Eskander
Department of Otolaryngology - Head and Neck Surgery, Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON, Canada
1 shared publicationDanny Enepekides
Department of Otolaryngology - Head and Neck Surgery, Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON, Canada
1 shared publicationEyesha Younus
Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON, Canada
1 shared publication
Latest Publications
- 4 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 186, 109790
Cine MRI-based analysis of intrafractional motion in radiation treatment planning of head and neck cancer patients
- 4 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 186, 109790
Cine MRI-based analysis of intrafractional motion in radiation treatment planning of head and neck cancer patients
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 115106
Development and assessment of an x-ray tube-based multi-beam x-ray scatter projection imaging system
Coherent scatter x-ray imaging systems are sensitive to material structure and chemical composition, and generate soft-material images with contrast superior to conventional transmission x-ray imaging. For practicality in medical or security applications, the image data acquisition time should be 2 object with 6000 pixels was 8.8 min. The width of a sharp edge in the scatter image was consistent with the pencil beam diameter. Contrast-detail performance was similar to our synchrotron-based system. In this first x-ray tube-based system, for simplicity, the transmitted x rays are measured through attenuators using the same flat-panel detector that measures scattered x rays. As a result, the primary image quality was reduced.
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 115106
Development and assessment of an x-ray tube-based multi-beam x-ray scatter projection imaging system
Coherent scatter x-ray imaging systems are sensitive to material structure and chemical composition, and generate soft-material images with contrast superior to conventional transmission x-ray imaging. For practicality in medical or security applications, the image data acquisition time should be 2 object with 6000 pixels was 8.8 min. The width of a sharp edge in the scatter image was consistent with the pencil beam diameter. Contrast-detail performance was similar to our synchrotron-based system. In this first x-ray tube-based system, for simplicity, the transmitted x rays are measured through attenuators using the same flat-panel detector that measures scattered x rays. As a result, the primary image quality was reduced.
- 1 March 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (3) , 035104
Development and assessment of a multi-beam continuous-phantom-motion x-ray scatter projection imaging system
X-ray image formation using scattered radiation can yield a superior contrast-to-noise ratio compared to conventional transmission x-ray imaging. A barrier to practical implementation of scatter imaging systems has been slow image acquisition. We have developed a projection imaging system which uses five monoenergetic pencil beams in combination with continuous phantom motion to achieve acquisition times that are practical for medical and security applications. The system was configured at the Canadian Light Source synchrotron and consists of a primary collimator, motorized stages for phantom translation, a flat-panel x-ray detector for measuring scattered x rays, and photodiodes for simultaneously measuring transmitted x rays. Image generation requires several corrections to raw data artifacts arising from the nature of the detector, x-ray source, and acquisition procedure. We developed a novel correction for pixel location inaccuracy arising from continuous phantom motion. A five-beam system had nearly five times faster acquisition than a single-beam system. Continuous motion acquisition was approximately 30 times faster than step-and-shoot acquisition. The total acquisition time for a 9 cm × 5 cm phantom with 8425 pixels was just over 2 min. Image quality was also assessed, in part to determine its relation to acquisition speed. The width of sharp material boundaries was found to be at a minimum equal to the pencil beam width (1.75 mm) and to have an additional width equal to the product of the phantom translation speed and the acquisition time per pixel (up to 1.0 mm in our experiments). Contrast-detail performance was independent of acquisition speed, depending only on phantom entrance x-ray fluence. Pixel signal-to-noise ratio measurements indicate that detector readout noise is important for the scatter data, even for phantom air kerma as high as 30 mGy. Images could be improved with a detector having lower readout noise and higher sensitivity. Its spatial resolution could be moderate. We confirmed that for the same range of λ−1 sin(θ/2), where λ is the x-ray wavelength and θ is the scattering angle, scatter images acquired using different beam energies (33–70 keV) had nearly identical contrast.
- 1 March 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (3) , 035104
Development and assessment of a multi-beam continuous-phantom-motion x-ray scatter projection imaging system
X-ray image formation using scattered radiation can yield a superior contrast-to-noise ratio compared to conventional transmission x-ray imaging. A barrier to practical implementation of scatter imaging systems has been slow image acquisition. We have developed a projection imaging system which uses five monoenergetic pencil beams in combination with continuous phantom motion to achieve acquisition times that are practical for medical and security applications. The system was configured at the Canadian Light Source synchrotron and consists of a primary collimator, motorized stages for phantom translation, a flat-panel x-ray detector for measuring scattered x rays, and photodiodes for simultaneously measuring transmitted x rays. Image generation requires several corrections to raw data artifacts arising from the nature of the detector, x-ray source, and acquisition procedure. We developed a novel correction for pixel location inaccuracy arising from continuous phantom motion. A five-beam system had nearly five times faster acquisition than a single-beam system. Continuous motion acquisition was approximately 30 times faster than step-and-shoot acquisition. The total acquisition time for a 9 cm × 5 cm phantom with 8425 pixels was just over 2 min. Image quality was also assessed, in part to determine its relation to acquisition speed. The width of sharp material boundaries was found to be at a minimum equal to the pencil beam width (1.75 mm) and to have an additional width equal to the product of the phantom translation speed and the acquisition time per pixel (up to 1.0 mm in our experiments). Contrast-detail performance was independent of acquisition speed, depending only on phantom entrance x-ray fluence. Pixel signal-to-noise ratio measurements indicate that detector readout noise is important for the scatter data, even for phantom air kerma as high as 30 mGy. Images could be improved with a detector having lower readout noise and higher sensitivity. Its spatial resolution could be moderate. We confirmed that for the same range of λ−1 sin(θ/2), where λ is the x-ray wavelength and θ is the scattering angle, scatter images acquired using different beam energies (33–70 keV) had nearly identical contrast.