Lynne Haslett
Research Subjects
Research Interests
Lynne Haslett has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Angela Fagerlin
University of Utah
2 shared publications - Anik Giguère
VITAM, Research Center for Sustainable Health, Integrated University Health and Social Services Center (CIUSSS) of the Capitale-Nationale, Laval University, Québec, QC, Canada
2 shared publications - Aubri Hoffman
Department of Gynecological Oncology and Reproductive Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
2 shared publications - Dawn Stacey
School of Nursing, University of Ottawa, Ottawa, Canada
2 shared publications - France Légaré
Department of Family Medicine and Emergency Medicine, Université Laval, Quebec, Quebec, Canada
2 shared publications - Gratianne Vaisson
Department of Family and Emergency Medicine, Faculty of Medicine, Laval University, Quebec City, Québec, Canada
2 shared publications
Latest Publications
- Open Access
- 16 March 2021
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 23 (3) , e15032
An 11-Item Measure of User- and Human-Centered Design for Personal Health Tools (UCD-11): Development and Validation
Background: Researchers developing personal health tools employ a range of approaches to involve prospective users in design and development. Objective: The aim of this paper was to develop a validated measure of the human- or user-centeredness of design and development processes for personal health tools. Methods: We conducted a psychometric analysis of data from a previous systematic review of the design and development processes of 348 personal health tools. Using a conceptual framework of user-centered design, our team of patients, caregivers, health professionals, tool developers, and researchers analyzed how specific practices in tool design and development might be combined and used as a measure. We prioritized variables according to their importance within the conceptual framework and validated the resultant measure using principal component analysis with Varimax rotation, classical item analysis, and confirmatory factor analysis. Results: We retained 11 items in a 3-factor structure explaining 68% of the variance in the data. The Cronbach alpha was .72. Confirmatory factor analysis supported our hypothesis of a latent construct of user-centeredness. Items were whether or not: (1) patient, family, caregiver, or surrogate users were involved in the steps that help tool developers understand users or (2) develop a prototype, (3) asked their opinions, (4) observed using the tool or (5) involved in steps intended to evaluate the tool, (6) the process had 3 or more iterative cycles, (7) changes between cycles were explicitly reported, (8) health professionals were asked their opinion and (9) consulted before the first prototype was developed or (10) between initial and final prototypes, and (11) a panel of other experts was involved. Conclusions: The User-Centered Design 11-item measure (UCD-11) may be used to quantitatively document the user/human-centeredness of design and development processes of patient-centered tools. By building an evidence base about such processes, we can help ensure that tools are adapted to people who will use them, rather than requiring people to adapt to tools.
- 16 March 2021
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 23 (3) , e15032
Open AccessAn 11-Item Measure of User- and Human-Centered Design for Personal Health Tools (UCD-11): Development and Validation
Background: Researchers developing personal health tools employ a range of approaches to involve prospective users in design and development. Objective: The aim of this paper was to develop a validated measure of the human- or user-centeredness of design and development processes for personal health tools. Methods: We conducted a psychometric analysis of data from a previous systematic review of the design and development processes of 348 personal health tools. Using a conceptual framework of user-centered design, our team of patients, caregivers, health professionals, tool developers, and researchers analyzed how specific practices in tool design and development might be combined and used as a measure. We prioritized variables according to their importance within the conceptual framework and validated the resultant measure using principal component analysis with Varimax rotation, classical item analysis, and confirmatory factor analysis. Results: We retained 11 items in a 3-factor structure explaining 68% of the variance in the data. The Cronbach alpha was .72. Confirmatory factor analysis supported our hypothesis of a latent construct of user-centeredness. Items were whether or not: (1) patient, family, caregiver, or surrogate users were involved in the steps that help tool developers understand users or (2) develop a prototype, (3) asked their opinions, (4) observed using the tool or (5) involved in steps intended to evaluate the tool, (6) the process had 3 or more iterative cycles, (7) changes between cycles were explicitly reported, (8) health professionals were asked their opinion and (9) consulted before the first prototype was developed or (10) between initial and final prototypes, and (11) a panel of other experts was involved. Conclusions: The User-Centered Design 11-item measure (UCD-11) may be used to quantitatively document the user/human-centeredness of design and development processes of patient-centered tools. By building an evidence base about such processes, we can help ensure that tools are adapted to people who will use them, rather than requiring people to adapt to tools.
- Open Access
- 13 June 2019
- Published by JMIR Publications Inc. in JMIR Preprints
An 11-Item Measure of User- and Human-Centered Design for Personal Health Tools (UCD-11): Development and Validation (Preprint)
BACKGROUND Researchers developing personal health tools employ a range of approaches to involve prospective users in design and development. OBJECTIVE The aim of this paper was to develop a validated measure of the human- or user-centeredness of design and development processes for personal health tools. METHODS We conducted a psychometric analysis of data from a previous systematic review of the design and development processes of 348 personal health tools. Using a conceptual framework of user-centered design, our team of patients, caregivers, health professionals, tool developers, and researchers analyzed how specific practices in tool design and development might be combined and used as a measure. We prioritized variables according to their importance within the conceptual framework and validated the resultant measure using principal component analysis with Varimax rotation, classical item analysis, and confirmatory factor analysis. RESULTS We retained 11 items in a 3-factor structure explaining 68% of the variance in the data. The Cronbach alpha was .72. Confirmatory factor analysis supported our hypothesis of a latent construct of user-centeredness. Items were whether or not: (1) patient, family, caregiver, or surrogate users were involved in the steps that help tool developers understand users or (2) develop a prototype, (3) asked their opinions, (4) observed using the tool or (5) involved in steps intended to evaluate the tool, (6) the process had 3 or more iterative cycles, (7) changes between cycles were explicitly reported, (8) health professionals were asked their opinion and (9) consulted before the first prototype was developed or (10) between initial and final prototypes, and (11) a panel of other experts was involved. CONCLUSIONS The User-Centered Design 11-item measure (UCD-11) may be used to quantitatively document the user/human-centeredness of design and development processes of patient-centered tools. By building an evidence base about such processes, we can help ensure that tools are adapted to people who will use them, rather than requiring people to adapt to tools.
- 13 June 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAn 11-Item Measure of User- and Human-Centered Design for Personal Health Tools (UCD-11): Development and Validation (Preprint)
BACKGROUND Researchers developing personal health tools employ a range of approaches to involve prospective users in design and development. OBJECTIVE The aim of this paper was to develop a validated measure of the human- or user-centeredness of design and development processes for personal health tools. METHODS We conducted a psychometric analysis of data from a previous systematic review of the design and development processes of 348 personal health tools. Using a conceptual framework of user-centered design, our team of patients, caregivers, health professionals, tool developers, and researchers analyzed how specific practices in tool design and development might be combined and used as a measure. We prioritized variables according to their importance within the conceptual framework and validated the resultant measure using principal component analysis with Varimax rotation, classical item analysis, and confirmatory factor analysis. RESULTS We retained 11 items in a 3-factor structure explaining 68% of the variance in the data. The Cronbach alpha was .72. Confirmatory factor analysis supported our hypothesis of a latent construct of user-centeredness. Items were whether or not: (1) patient, family, caregiver, or surrogate users were involved in the steps that help tool developers understand users or (2) develop a prototype, (3) asked their opinions, (4) observed using the tool or (5) involved in steps intended to evaluate the tool, (6) the process had 3 or more iterative cycles, (7) changes between cycles were explicitly reported, (8) health professionals were asked their opinion and (9) consulted before the first prototype was developed or (10) between initial and final prototypes, and (11) a panel of other experts was involved. CONCLUSIONS The User-Centered Design 11-item measure (UCD-11) may be used to quantitatively document the user/human-centeredness of design and development processes of patient-centered tools. By building an evidence base about such processes, we can help ensure that tools are adapted to people who will use them, rather than requiring people to adapt to tools.