Haidong Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Haidong Huang has a total of 188 co-authors. Here are the top co-authors by number of shared publications:
- Paul Zarogoulidis
Pulmonary Department, General Clinic Euromedica, Thessaloniki, Greece
15 shared publications - Chong Bai
Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Naval Medical University, Shanghai, China
7 shared publications Qin Wang
Department of Respiratory and Critical Care Medicine, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
7 shared publications- Wolfgang Hohenforst-Schmidt
Sana Clinic Group Franken, Department of Cardiology/Pulmonology/Intensive Care/Nephrology, “Hof” Clinics, University of Erlangen, 91052 Hof, Germany
7 shared publications Chong Bai
Department of Respiratory and Critical Care Medicine, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
5 shared publicationsKonstantinos Sapalidis
rd Surgery Department, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
5 shared publications
Latest Publications
- Open Access
- 25 May 2026
- Published by Ivyspring International Publisher in Journal of Cancer
- Vol. 17 (6) , 1187-1194
CellVizio ® System for Mesothorax Lymphadenopathy Rapid on Site, 18G needle: Pros and Cons
Introduction: The best tissue sample is still very important for the diagnosis of mesothorax lymphadenopathy. In the past 20 years endobronchial ultrasound (EBUS) has been used efficiently in most cases of primary lung cancer disease or metastatic disease. Several new type of needles have been created such 19G, 18G and hybrid biopsies with cryoprobes. Rapid on-site evaluation (ROSE) is used as an additional initial diagnostic tool. Confocal microscopy is a method of rapid on-site evaluation.
- 25 May 2026
- Published by Ivyspring International Publisher in Journal of Cancer
- Vol. 17 (6) , 1187-1194
Open AccessCellVizio ® System for Mesothorax Lymphadenopathy Rapid on Site, 18G needle: Pros and Cons
Introduction: The best tissue sample is still very important for the diagnosis of mesothorax lymphadenopathy. In the past 20 years endobronchial ultrasound (EBUS) has been used efficiently in most cases of primary lung cancer disease or metastatic disease. Several new type of needles have been created such 19G, 18G and hybrid biopsies with cryoprobes. Rapid on-site evaluation (ROSE) is used as an additional initial diagnostic tool. Confocal microscopy is a method of rapid on-site evaluation.
- Open Access
- 19 May 2026
- Published by Wolters Kluwer Health in Chinese Medical Journal
- Vol. 139 (13) , 2033-2035
Macroscopic on-site evaluation based on core tissues length and weight during EBUS-TBNA using 22-gauge needles
- 19 May 2026
- Published by Wolters Kluwer Health in Chinese Medical Journal
- Vol. 139 (13) , 2033-2035
Open AccessMacroscopic on-site evaluation based on core tissues length and weight during EBUS-TBNA using 22-gauge needles
- Open Access
- 21 March 2025
- Published by Ivyspring International Publisher in Journal of Cancer
- Vol. 16 (7) , 2124-2144
Vessel sign analysis paves the way to optimized CBCT application in interventional pulmonology: COMBINED algorithm as a one-stop-shop
Introduction: We used CBCT application as one-stop-shop nodule orientated approach in regards to increase DY, reduce complication rate, reduce time on-table and economical costs with classical peripheral instruments including mini-cryoprobe (ERBE 1,1mm), rEBUS (Olympus) and standard RUFBs (Olympus Company) with at least 2mm working channel and 4,2mm outer diameter for the diagnosis of peripheral targets (iSPNs) in a prospective all-comers registry after detailed analysis of pre-interventional CT for vessel- and bronchus sign classes.
- 21 March 2025
- Published by Ivyspring International Publisher in Journal of Cancer
- Vol. 16 (7) , 2124-2144
Open AccessVessel sign analysis paves the way to optimized CBCT application in interventional pulmonology: COMBINED algorithm as a one-stop-shop
Introduction: We used CBCT application as one-stop-shop nodule orientated approach in regards to increase DY, reduce complication rate, reduce time on-table and economical costs with classical peripheral instruments including mini-cryoprobe (ERBE 1,1mm), rEBUS (Olympus) and standard RUFBs (Olympus Company) with at least 2mm working channel and 4,2mm outer diameter for the diagnosis of peripheral targets (iSPNs) in a prospective all-comers registry after detailed analysis of pre-interventional CT for vessel- and bronchus sign classes.
- 6 January 2025
- Published by Elsevier in Archivos de Bronconeumología
- Vol. 61 (5) , 303-304
Multimodality Imaging With Confocal Laser Endomicroscopy, Red Dichromatic Imaging, and Virtual Bronchoscopic Navigation Guided Recanalization of Complete Airway Obstruction Caused by Tracheobronchial Amyloidosis
- 6 January 2025
- Published by Elsevier in Archivos de Bronconeumología
- Vol. 61 (5) , 303-304
Multimodality Imaging With Confocal Laser Endomicroscopy, Red Dichromatic Imaging, and Virtual Bronchoscopic Navigation Guided Recanalization of Complete Airway Obstruction Caused by Tracheobronchial Amyloidosis
- Open Access
- 1 May 2024
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 11, 1293940
A preclinical animal study to evaluate the operability and safety of domestic one-way endobronchial valves
Purpose: To evaluate the operability and safety of bronchoscopic domestic one-way endobronchial valves (EBV) on animals.Methods: Nine pigs were randomly assigned (2:1) to receive domestic one-way EBV (the experimental group, n = 6) and Zephyr® EBV (the control group, n = 3). Routine blood tests, arterial blood gases, and CT scans of the lungs were performed 1 day pre-procedure in addition to 1 week and 1 month post-procedure to assess changes in blood markers and lung volumes. At 1 month post-procedure, the animals were sacrificed, followed by removal of all valves via bronchoscopy. Pathological examinations of critical organs were subsequently performed.Results: A total of 15 valves were placed in the experimental group and 6 valves were placed in the control group, without serious complications. Routine blood tests and arterial blood gas examinations at 1 day pre-procedure, 1 week post-procedure, and 1 month post-procedure did not differ significantly in both groups. No EBV displacement was noted under bronchoscopy, and the valve was smoothly removable by bronchoscope at 1 month post-procedure. At 1 week post-procedure, varying degrees of target lung lobe volume reduction were observed on lung CT in both groups. Lung volume reduction was achieved at 1 month post-procedure in both groups, without significant statistical difference. Although 3 cases in the experimental group and 1 case in the control group developed varying degrees of pneumonia, the inflammatory response did not increase over time during the experimental period. Pathological examination revealed no significant abnormal changes in the critical organs for both groups.Conclusion: Our results demonstrate that domestic EBV is safe and reliable for endobronchial application in general-grade laboratory white pigs. The safety of domestic EBV is similar to that of Zephyr® EBV, with good ease of use and operability. This kind of domestic EBV can meet the safety evaluation requirements for animal testing.
- 1 May 2024
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 11, 1293940
Open AccessA preclinical animal study to evaluate the operability and safety of domestic one-way endobronchial valves
Purpose: To evaluate the operability and safety of bronchoscopic domestic one-way endobronchial valves (EBV) on animals.Methods: Nine pigs were randomly assigned (2:1) to receive domestic one-way EBV (the experimental group, n = 6) and Zephyr® EBV (the control group, n = 3). Routine blood tests, arterial blood gases, and CT scans of the lungs were performed 1 day pre-procedure in addition to 1 week and 1 month post-procedure to assess changes in blood markers and lung volumes. At 1 month post-procedure, the animals were sacrificed, followed by removal of all valves via bronchoscopy. Pathological examinations of critical organs were subsequently performed.Results: A total of 15 valves were placed in the experimental group and 6 valves were placed in the control group, without serious complications. Routine blood tests and arterial blood gas examinations at 1 day pre-procedure, 1 week post-procedure, and 1 month post-procedure did not differ significantly in both groups. No EBV displacement was noted under bronchoscopy, and the valve was smoothly removable by bronchoscope at 1 month post-procedure. At 1 week post-procedure, varying degrees of target lung lobe volume reduction were observed on lung CT in both groups. Lung volume reduction was achieved at 1 month post-procedure in both groups, without significant statistical difference. Although 3 cases in the experimental group and 1 case in the control group developed varying degrees of pneumonia, the inflammatory response did not increase over time during the experimental period. Pathological examination revealed no significant abnormal changes in the critical organs for both groups.Conclusion: Our results demonstrate that domestic EBV is safe and reliable for endobronchial application in general-grade laboratory white pigs. The safety of domestic EBV is similar to that of Zephyr® EBV, with good ease of use and operability. This kind of domestic EBV can meet the safety evaluation requirements for animal testing.
- Open Access
- 1 January 2024
- Published by SAGE Publications in Therapeutic Advances in Respiratory Disease
- Vol. 18
Comparison of Synapse 3D system (Version 4.4) and DirectPath system (Version 2.0) in virtual bronchoscopic navigation application for peripheral pulmonary nodules
Background: Differences between virtual bronchoscopic navigation (VBN) systems and their impacts on the diagnostic yield of transbronchial biopsy (TBB) of peripheral pulmonary nodules (PPNs) remain unclear. Objectives: To compare the Synapse 3D system (Version 4.4, Fujifilm, Japan) and DirectPath system (Version 2.0, Olympus, Japan) in the VBN application of PPNs. Design: Retrospective study with self-paired design and exploratory study with retrospective cohort design. Methods: The study analyzed patients with PPNs using the Synapse 3D system (Group S) and DirectPath system (Group D) and compared differences between the two groups in bronchial tree reconstruction, navigation pathway planning, and VBN-assisted TBB of PPNs. Results: In all, 289 patients were analyzed ultimately. Bronchial tree reconstruction quality was better in Group S ( p < 0.001). Navigation pathway planning duration in Group S was longer than that in Group D (median 1.35 vs 1.04 s, p < 0.001). Automated navigation pathway planning success rate in Group S was higher than that in Group D (36.7% vs 19.7%, p < 0.001), and CT image reconstruction parameter and nodule diameter, bronchus sign, and distance from the hilum had significant effects on it in both groups. Fifty-six patients in Group S and forty-two patients in Group D were analyzed ultimately. The localization success rate and diagnostic yield of PPNs between the two groups were not significantly different (85.3% vs 91.2% and 67.6% vs 61.8%, respectively, p > 0.05). Conclusion: Synapse 3D system (Version 4.4) and DirectPath system (Version 2.0) had their own merits. Localization success rate and diagnostic yield of VBN-assisted TBB were of no statistical difference for these two VBN systems. Improvements in segmentation algorithms of VBN systems and using the most suitable chest CT scan data for them may be the breakthrough to improve the efficiency of VBN, especially for poor experienced interventional physicians.
- 1 January 2024
- Published by SAGE Publications in Therapeutic Advances in Respiratory Disease
- Vol. 18
Open AccessComparison of Synapse 3D system (Version 4.4) and DirectPath system (Version 2.0) in virtual bronchoscopic navigation application for peripheral pulmonary nodules
Background: Differences between virtual bronchoscopic navigation (VBN) systems and their impacts on the diagnostic yield of transbronchial biopsy (TBB) of peripheral pulmonary nodules (PPNs) remain unclear. Objectives: To compare the Synapse 3D system (Version 4.4, Fujifilm, Japan) and DirectPath system (Version 2.0, Olympus, Japan) in the VBN application of PPNs. Design: Retrospective study with self-paired design and exploratory study with retrospective cohort design. Methods: The study analyzed patients with PPNs using the Synapse 3D system (Group S) and DirectPath system (Group D) and compared differences between the two groups in bronchial tree reconstruction, navigation pathway planning, and VBN-assisted TBB of PPNs. Results: In all, 289 patients were analyzed ultimately. Bronchial tree reconstruction quality was better in Group S ( p < 0.001). Navigation pathway planning duration in Group S was longer than that in Group D (median 1.35 vs 1.04 s, p < 0.001). Automated navigation pathway planning success rate in Group S was higher than that in Group D (36.7% vs 19.7%, p < 0.001), and CT image reconstruction parameter and nodule diameter, bronchus sign, and distance from the hilum had significant effects on it in both groups. Fifty-six patients in Group S and forty-two patients in Group D were analyzed ultimately. The localization success rate and diagnostic yield of PPNs between the two groups were not significantly different (85.3% vs 91.2% and 67.6% vs 61.8%, respectively, p > 0.05). Conclusion: Synapse 3D system (Version 4.4) and DirectPath system (Version 2.0) had their own merits. Localization success rate and diagnostic yield of VBN-assisted TBB were of no statistical difference for these two VBN systems. Improvements in segmentation algorithms of VBN systems and using the most suitable chest CT scan data for them may be the breakthrough to improve the efficiency of VBN, especially for poor experienced interventional physicians.
- Open Access
- 1 January 2024
- Published by Ivyspring International Publisher in Journal of Cancer
- Vol. 15 (4) , 908-915
EBUS-TBLC increase the diagnosis rate in different type of peripheral pulmonary lesions
Background and objective: Recently, endobronchial ultrasonography with guide sheath-guided (EBUS-GS) has been increasingly used in the diagnosis of peripheral pulmonary lesions (PPLs) from human natural orifice. However, the diagnostic rate is still largely dependent on the location of the lesion and the probe. Here, we reported a new procedure to improve the diagnostic rate of EBUS-transbronchial lung cryobiopsy (EBUS-TBLC), which performed under general anesthesia with laryngeal mask airway (LMA) in all of the patients. This study retrospectively evaluated the diagnosis of PPLs with 'blind-ending' type (Type I) and 'pass-through' type procedures (Type II) of EBUS-GS-TBLB or EBUS-TBLC respectively.
- 1 January 2024
- Published by Ivyspring International Publisher in Journal of Cancer
- Vol. 15 (4) , 908-915
Open AccessEBUS-TBLC increase the diagnosis rate in different type of peripheral pulmonary lesions
Background and objective: Recently, endobronchial ultrasonography with guide sheath-guided (EBUS-GS) has been increasingly used in the diagnosis of peripheral pulmonary lesions (PPLs) from human natural orifice. However, the diagnostic rate is still largely dependent on the location of the lesion and the probe. Here, we reported a new procedure to improve the diagnostic rate of EBUS-transbronchial lung cryobiopsy (EBUS-TBLC), which performed under general anesthesia with laryngeal mask airway (LMA) in all of the patients. This study retrospectively evaluated the diagnosis of PPLs with 'blind-ending' type (Type I) and 'pass-through' type procedures (Type II) of EBUS-GS-TBLB or EBUS-TBLC respectively.
- Open Access
- 31 July 2023
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 13, 1168870
Predictive value of the resistance of the probe to pass through the lesion in the diagnosis of peripheral pulmonary lesions using radial probe endobronchial ultrasound with a guide sheath
Background: Transbronchial lung biopsy guided by radial probe endobronchial ultrasonography with a guide sheath (EBUS-GS-TBLB) is becoming a significant approach for diagnosing peripheral pulmonary lesions (PPLs). We aimed to explore the clinical value of the resistance of the probe to pass through the lesion in the diagnosis of PPLs when performing EBUS-GS-TBLB, and to determine the optimum number of EBUS-GS-TBLB.Methods: We performed a prospective, single-center study of 126 consecutive patients who underwent EBUS-GS-TBLB for solid and positive-bronchus-sign PPLs where the probe was located within the lesion from September 2019 to May 2022. The classification of probe resistance for each lesion was carried out by two bronchoscopists independently, and the final result depended on the bronchoscopist responsible for the procedures. The primary endpoint was the diagnostic yield according with the resistance pattern. The secondary endpoints were the optimum number of EBUS-GS-TBLB and factors affecting diagnostic yield. Procedural complications were also recorded.Results: The total diagnostic yield of EBUS-GS-TBLB was 77.8%, including 83.8% malignant and 67.4% benign diseases (P=0.033). Probe resistance type II displayed the highest diagnostic yield (87.5%), followed by type III (81.0%) and type I (61.1%). A significant difference between the diagnostic yield of malignant and benign diseases was detected in type II (P = 0.008), whereas others did not. Although most of the malignant PPLs with a definitive diagnosis using EBUS-GS-TBLB in type II or type III could be diagnosed in the first biopsy, the fourth biopsy contributed the most sufficient biopsy samples. In contrast, considerably limited tissue specimens could be obtained for each biopsy in type I. The inter-observer agreement of the two blinded bronchoscopists for the classification of probe resistance was excellent (κ = 0.84).Conclusion: The probe resistance is a useful predictive factor for successful EBUS-GS-TBLB diagnosis of solid and positive-bronchus-sign PPLs where the probe was located within the lesion. Four serial biopsies are appropriate for both probe resistance type II and type III, and additional diagnostic procedures are needed for type I.
- 31 July 2023
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 13, 1168870
Open AccessPredictive value of the resistance of the probe to pass through the lesion in the diagnosis of peripheral pulmonary lesions using radial probe endobronchial ultrasound with a guide sheath
Background: Transbronchial lung biopsy guided by radial probe endobronchial ultrasonography with a guide sheath (EBUS-GS-TBLB) is becoming a significant approach for diagnosing peripheral pulmonary lesions (PPLs). We aimed to explore the clinical value of the resistance of the probe to pass through the lesion in the diagnosis of PPLs when performing EBUS-GS-TBLB, and to determine the optimum number of EBUS-GS-TBLB.Methods: We performed a prospective, single-center study of 126 consecutive patients who underwent EBUS-GS-TBLB for solid and positive-bronchus-sign PPLs where the probe was located within the lesion from September 2019 to May 2022. The classification of probe resistance for each lesion was carried out by two bronchoscopists independently, and the final result depended on the bronchoscopist responsible for the procedures. The primary endpoint was the diagnostic yield according with the resistance pattern. The secondary endpoints were the optimum number of EBUS-GS-TBLB and factors affecting diagnostic yield. Procedural complications were also recorded.Results: The total diagnostic yield of EBUS-GS-TBLB was 77.8%, including 83.8% malignant and 67.4% benign diseases (P=0.033). Probe resistance type II displayed the highest diagnostic yield (87.5%), followed by type III (81.0%) and type I (61.1%). A significant difference between the diagnostic yield of malignant and benign diseases was detected in type II (P = 0.008), whereas others did not. Although most of the malignant PPLs with a definitive diagnosis using EBUS-GS-TBLB in type II or type III could be diagnosed in the first biopsy, the fourth biopsy contributed the most sufficient biopsy samples. In contrast, considerably limited tissue specimens could be obtained for each biopsy in type I. The inter-observer agreement of the two blinded bronchoscopists for the classification of probe resistance was excellent (κ = 0.84).Conclusion: The probe resistance is a useful predictive factor for successful EBUS-GS-TBLB diagnosis of solid and positive-bronchus-sign PPLs where the probe was located within the lesion. Four serial biopsies are appropriate for both probe resistance type II and type III, and additional diagnostic procedures are needed for type I.
- Open Access
Positron Emission-Computed Tomography, Cryobiopsy versus Bronchoalveolar Lavage and Computed Tomography Findings for Interstitial Lung Disease: A Long-Term Follow-Up
Background and Objectives: Interstitial lung diseases have always been an issue for pulmonary and rheumatology physicians. Computed tomography scans with a high-resolution protocol and bronchoalveolar lavage have been used along with biochemical blood tests to reach a diagnosis. Materials and Methods: We included 80 patients in total. First, all patients had their diagnosis with computed tomography of the thorax, serological/ immunological blood tests and bronchoalveolar lavage. However; after 3 months, all were divided into 2 groups: those who had bronchoalveolar lavage again and those who had cryobiopsy instead of bronchoalveolar lavage (40/40). Positron emission-computed tomography was also performed upon the first and second diagnosis. The patients’ follow-up was 4 years from diagnosis. Results: Patients suffered most from chronic obstructive pulmonary disease (56, 70%), while lung cancer was rarely encountered in the sample (7, 9.75%). Age distribution ranged between 53 and 68 years with a mean value of 60 years. The computed tomography findings revealed 25 patients with typical diagnosis (35.2%), 17 with interstitial pulmonary fibrosis (23.9%) and 11 with probable diagnosis (11%). The cryobiopsy technique led to a new diagnosis in 28 patients (35% of the total sample). Patients who had a new diagnosis with cryobiopsy had a mean survival time of 710 days (Conclusions: Cryobiopsy is a safe tool for patients with interstitial lung disease and can assist in the diagnosis of interstitial lung diseases. The survival of patients was increased in the cryobiopsy group versus only bronchoalveolar lavage for disease diagnosis.
Open AccessPositron Emission-Computed Tomography, Cryobiopsy versus Bronchoalveolar Lavage and Computed Tomography Findings for Interstitial Lung Disease: A Long-Term Follow-Up
Background and Objectives: Interstitial lung diseases have always been an issue for pulmonary and rheumatology physicians. Computed tomography scans with a high-resolution protocol and bronchoalveolar lavage have been used along with biochemical blood tests to reach a diagnosis. Materials and Methods: We included 80 patients in total. First, all patients had their diagnosis with computed tomography of the thorax, serological/ immunological blood tests and bronchoalveolar lavage. However; after 3 months, all were divided into 2 groups: those who had bronchoalveolar lavage again and those who had cryobiopsy instead of bronchoalveolar lavage (40/40). Positron emission-computed tomography was also performed upon the first and second diagnosis. The patients’ follow-up was 4 years from diagnosis. Results: Patients suffered most from chronic obstructive pulmonary disease (56, 70%), while lung cancer was rarely encountered in the sample (7, 9.75%). Age distribution ranged between 53 and 68 years with a mean value of 60 years. The computed tomography findings revealed 25 patients with typical diagnosis (35.2%), 17 with interstitial pulmonary fibrosis (23.9%) and 11 with probable diagnosis (11%). The cryobiopsy technique led to a new diagnosis in 28 patients (35% of the total sample). Patients who had a new diagnosis with cryobiopsy had a mean survival time of 710 days (Conclusions: Cryobiopsy is a safe tool for patients with interstitial lung disease and can assist in the diagnosis of interstitial lung diseases. The survival of patients was increased in the cryobiopsy group versus only bronchoalveolar lavage for disease diagnosis.