Xiaojun Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaojun Wang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jiaye Ye
School of Chemistry and Physics Faculty of Science Queensland University of Technology Brisbane Queensland Australia
2 shared publications - Chunli Guo
College of Materials Science and Engineering Taiyuan University of Technology Taiyuan P. R. China
1 shared publication - Genwei Wang
College of Aeronautics and Astronautics, Taiyuan University of Technology, Jinzhong 030600, China
1 shared publication - Hui Song
College of Aeronautics and Astronautics, Taiyuan University of Technology, Taiyuan 030024, China
1 shared publication - Jiajun Chen
Institute of Applied Mechanics, College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, Taiyuan 030024, China
1 shared publication - Meiqing Guo
College of Mechanics, Taiyuan University of Technology, Taiyuan 030024, China
1 shared publication
Latest Publications
- Open Access
Electrochemical Performance and Stress Distribution of Sb/Sb2O3 Nanoparticles as Anode Materials for Sodium-Ion Batteries
We synthesize Sb/Sb2O3 nanoparticles by the oxidation of Sb nanoparticles at 100, 200, and 300 °C. The half sodium-ion batteries with Sb/Sb2O3-200 exhibit the optimal performance with a charge capacity of 540 mAh g−1 after 100 cycles at 0.1 A g−1, maintaining up to six times more capacity than pure Sb, and superior rate performance with 95.7% retention after cycling at varied current densities. One reason for this is that Sb/Sb2O3-200 is at exactly the optimum ratio of Sb2O3:Sb and the particle size of Sb/Sb2O3 to ensure both high capacity for Na+ and small stress during sodiation/desodiation, which is confirmed by the diffusion–stress coupled results. It indicates that increasing the ratio of Sb2O3:Sb causes a decrease of Mises equivalent stress, radial stress, and tangential stress in the range of 1:1–3.5:1, and an increase in the range of 3.5:1–4:1. These stresses decrease with a particle radius in the range of 30–50 nm and increase with a particle radius in the range of 50–70 nm. Additionally, another reason is related to the formation of cycling-induced coral-like Sb, which can promote Na+ diffusion, relieve cycling-induced volume changes, and provide exceptional Na+ storage.
Open AccessElectrochemical Performance and Stress Distribution of Sb/Sb2O3 Nanoparticles as Anode Materials for Sodium-Ion Batteries
We synthesize Sb/Sb2O3 nanoparticles by the oxidation of Sb nanoparticles at 100, 200, and 300 °C. The half sodium-ion batteries with Sb/Sb2O3-200 exhibit the optimal performance with a charge capacity of 540 mAh g−1 after 100 cycles at 0.1 A g−1, maintaining up to six times more capacity than pure Sb, and superior rate performance with 95.7% retention after cycling at varied current densities. One reason for this is that Sb/Sb2O3-200 is at exactly the optimum ratio of Sb2O3:Sb and the particle size of Sb/Sb2O3 to ensure both high capacity for Na+ and small stress during sodiation/desodiation, which is confirmed by the diffusion–stress coupled results. It indicates that increasing the ratio of Sb2O3:Sb causes a decrease of Mises equivalent stress, radial stress, and tangential stress in the range of 1:1–3.5:1, and an increase in the range of 3.5:1–4:1. These stresses decrease with a particle radius in the range of 30–50 nm and increase with a particle radius in the range of 50–70 nm. Additionally, another reason is related to the formation of cycling-induced coral-like Sb, which can promote Na+ diffusion, relieve cycling-induced volume changes, and provide exceptional Na+ storage.
- 25 August 2020
- Vol. 37 (4) , 608-613
Corvis ST 检测在体角膜生物力学性能的有限元模拟
角膜的刚度降低是导致圆锥角膜的关键因素,角膜中胶原纤维刚度和纤维分散程度与角膜生物力学性能密切相关。本文通过建立基于角膜微结构即考虑胶原纤维的准分子激光原位角膜磨镶术(LASIK)术前和术后人眼角膜有限元模型,模拟了可视化角膜生物力学分析仪的检测过程,并与临床实际检测结果对比,确定屈光手术前后人眼角膜材料的超弹性本构参数及角膜胶原纤维刚度模量。研究发现 LASIK 术后,角膜胶原纤维刚度模量较术前明显增大,并与中央角膜厚度(CCT)高度相关;术前术后角膜胶原纤维刚度模量与对应中央角膜厚度的预测关系分别为:k1 术前 = exp(9.14 − 0.009CCT 术前),k1 术后 = exp(8.82 − 0.008CCT 术后)。根据本文的研究结果,可由患者的中央角膜厚度值估算其术前术后胶原纤维刚度模量,进而建立与患者实际情况更相符的个性化角膜模型,为更准确地预测角膜安全手术切削量提供理论参考。
- 25 August 2020
- Vol. 37 (4) , 608-613
Corvis ST 检测在体角膜生物力学性能的有限元模拟
角膜的刚度降低是导致圆锥角膜的关键因素,角膜中胶原纤维刚度和纤维分散程度与角膜生物力学性能密切相关。本文通过建立基于角膜微结构即考虑胶原纤维的准分子激光原位角膜磨镶术(LASIK)术前和术后人眼角膜有限元模型,模拟了可视化角膜生物力学分析仪的检测过程,并与临床实际检测结果对比,确定屈光手术前后人眼角膜材料的超弹性本构参数及角膜胶原纤维刚度模量。研究发现 LASIK 术后,角膜胶原纤维刚度模量较术前明显增大,并与中央角膜厚度(CCT)高度相关;术前术后角膜胶原纤维刚度模量与对应中央角膜厚度的预测关系分别为:k1 术前 = exp(9.14 − 0.009CCT 术前),k1 术后 = exp(8.82 − 0.008CCT 术后)。根据本文的研究结果,可由患者的中央角膜厚度值估算其术前术后胶原纤维刚度模量,进而建立与患者实际情况更相符的个性化角膜模型,为更准确地预测角膜安全手术切削量提供理论参考。
- Open Access
- 17 January 2017
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 16 (1) , 20
Effects of ablation depth and repair time on the corneal elastic modulus after laser in situ keratomileusis
The biomechanical properties of the cornea should be taken into account in the refractive procedure in order to perform refractive surgery more accurately. The effects of the ablation depth and repair time on the elastic modulus of the rabbit cornea after laser in situ keratomileusis (LASIK) are still unclear. In this study, LASIK was performed on New Zealand rabbits with different ablation depth (only typical LASIK flaps were created; residual stroma bed was 50 or 30% of the whole cornea thickness respectively). The animals without any treatment were served as normal controls. The corneal thickness was measured by ultrasonic pachymetry before animals were humanly killed after 7 or 28 days post-operatively. The corneal elastic modulus was measured by uniaxial tensile testing. A mathematical procedure considering the actual geometrics of the cornea was created to analyze the corneal elastic modulus. There were no obvious differences among all groups in the elastic modulus on after 7 days post-operatively. However, after 28th days post-operatively, there was a significant increase in the elastic modulus with 50 and 30% residual stroma bed; only the elastic modulus of the cornea with 30% residual stroma bed was significantly higher than that of 7 days. Changes in elastic modulus after LASIK suggest that this biomechanical effect may correlate with the ablation depth and repair time.
- 17 January 2017
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 16 (1) , 20
Open AccessEffects of ablation depth and repair time on the corneal elastic modulus after laser in situ keratomileusis
The biomechanical properties of the cornea should be taken into account in the refractive procedure in order to perform refractive surgery more accurately. The effects of the ablation depth and repair time on the elastic modulus of the rabbit cornea after laser in situ keratomileusis (LASIK) are still unclear. In this study, LASIK was performed on New Zealand rabbits with different ablation depth (only typical LASIK flaps were created; residual stroma bed was 50 or 30% of the whole cornea thickness respectively). The animals without any treatment were served as normal controls. The corneal thickness was measured by ultrasonic pachymetry before animals were humanly killed after 7 or 28 days post-operatively. The corneal elastic modulus was measured by uniaxial tensile testing. A mathematical procedure considering the actual geometrics of the cornea was created to analyze the corneal elastic modulus. There were no obvious differences among all groups in the elastic modulus on after 7 days post-operatively. However, after 28th days post-operatively, there was a significant increase in the elastic modulus with 50 and 30% residual stroma bed; only the elastic modulus of the cornea with 30% residual stroma bed was significantly higher than that of 7 days. Changes in elastic modulus after LASIK suggest that this biomechanical effect may correlate with the ablation depth and repair time.
- 12 May 2016
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 45 (8) , 4237-4245
Facile Synthesis of Hierarchical CuO Nanoflower for Supercapacitor Electrodes
- 12 May 2016
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 45 (8) , 4237-4245
Facile Synthesis of Hierarchical CuO Nanoflower for Supercapacitor Electrodes