Masato Kitayama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masato Kitayama has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Hashimoto
Hirosaki University Medicine Hospital
2 shared publications- Junichi Saito
Department of Anesthesiology, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
2 shared publications Kazuyoshi Hirota
Hirosaki University Graduate School of Medicine
2 shared publications- Kazuyoshi Hirota
Working Group for Academic Promotion Project, Japan Federation of Anesthesiologists, Kobe, Japan
2 shared publications Morito Wada
Aomori Prefectural Central Hospital
2 shared publicationsTsuyoshi Kudo
Hirosaki University Graduate School of Medicine
2 shared publications
Latest Publications
- Open Access
- 13 January 2017
- Published by Springer Nature in JA Clinical Reports
- Vol. 3 (1) , 6
Interference with pulse oximetry by the Stealth Station™ Image Guidance System
A pulse oximeter is one of the most important monitors to save patients undergoing anesthesia and monitored sedation. The authors report a case of orthopedic surgery, in which interference of pulse oximetry occurred when using a Stealth Station™ navigation system (Medtronic Sofamor Danek, Memphis, TN). Applying a black plastic shield (Masimo Ambient Shield: Masimo Corporation, Irvine, CA) completely eliminated the interference. A 37-year-old male patient with a giant cell tumor of the left femur was scheduled to undergo curettage of the femur using an intraoperative CT three-dimensional imaging system (O-arm™) and Stealth Station™ navigation system. During the surgery, the SpO2 value, which was maintained between 97 and 99% until the time, disappeared suddenly with abnormal pulse wave. Because a distortion in the SpO2 value was reproduced by repeated movement of cameras on the head of the Stealth Station™ navigation system, we recognized that the interference signal was coming from the navigation system. To eliminate the infrared light, the pulse oximetry probe was covered with a black plastic shield and the interference was completely eliminated. The Stealth Station™ navigation system was found to interfere with the SpO2 value, and a black plastic shield was useful for eliminating the interfering signal. Anesthesiologists should understand the risk of interference by the neuro-navigation system and know how to solve the problem.
- 13 January 2017
- Published by Springer Nature in JA Clinical Reports
- Vol. 3 (1) , 6
Open AccessInterference with pulse oximetry by the Stealth Station™ Image Guidance System
A pulse oximeter is one of the most important monitors to save patients undergoing anesthesia and monitored sedation. The authors report a case of orthopedic surgery, in which interference of pulse oximetry occurred when using a Stealth Station™ navigation system (Medtronic Sofamor Danek, Memphis, TN). Applying a black plastic shield (Masimo Ambient Shield: Masimo Corporation, Irvine, CA) completely eliminated the interference. A 37-year-old male patient with a giant cell tumor of the left femur was scheduled to undergo curettage of the femur using an intraoperative CT three-dimensional imaging system (O-arm™) and Stealth Station™ navigation system. During the surgery, the SpO2 value, which was maintained between 97 and 99% until the time, disappeared suddenly with abnormal pulse wave. Because a distortion in the SpO2 value was reproduced by repeated movement of cameras on the head of the Stealth Station™ navigation system, we recognized that the interference signal was coming from the navigation system. To eliminate the infrared light, the pulse oximetry probe was covered with a black plastic shield and the interference was completely eliminated. The Stealth Station™ navigation system was found to interfere with the SpO2 value, and a black plastic shield was useful for eliminating the interfering signal. Anesthesiologists should understand the risk of interference by the neuro-navigation system and know how to solve the problem.
- 9 January 2017
- Published by Springer Nature in Journal of Anesthesia
- Vol. 31 (2) , 193-197
Impact of acute changes in perfusion index and blood pressure on the accuracy of non-invasive continuous hemoglobin concentration measurements during induction of anesthesia
Purpose Several factors affect the accuracy of non-invasive continuous hemoglobin concentration (SpHb) measurements. We had previously shown an increase in the perfusion index (PI) following induction of anesthesia which was associated with an increase in the difference between SpHb and total hemoglobin (tHb) (SpHb–tHb). We hypothesized that blunting the increase in PI by maintaining blood pressure during induction of anesthesia would improve the agreement between SpHb and tHb measurements. Methods Twenty-nine adult patients were enrolled. Patients were randomly assigned by use of sequentially numbered, opaque sealed envelopes to a control (group C) or a phenylephrine group (group P). Anesthesia was induced and maintained with propofol, remifentanil, and ketamine. In group P, phenylephrine was infused at 0.5 µg/kg/min during induction of anesthesia. SpHb and PI were monitored with a Radical-7 Pulse CO-Oximeter. tHb and hematocrit were measured with the ABL800 blood gas analyzer. Results Following induction of anesthesia, PI increased significantly in both groups (p < 0.001 and p < 0.05 in groups C and P, respectively). However, the increase in PI was significantly smaller in group P than in group C (2.6 ± 1.3 vs 0.8 ± 1.4%, p < 0.001). Similarly, the change in SpHb–tHb was significantly smaller in group P than in group C (0.40 ± 0.78 vs 0.97 ± 0.70 g/dl, p < 0.05). Changes in SpHb–tHb are correlated with changes in PI (r = 0.46, p < 0.05). Conclusions The findings suggest that blunting the increase in PI by maintaining arterial pressure during induction of anesthesia improves the agreement between SpHb and tHb values.
- 9 January 2017
- Published by Springer Nature in Journal of Anesthesia
- Vol. 31 (2) , 193-197
Impact of acute changes in perfusion index and blood pressure on the accuracy of non-invasive continuous hemoglobin concentration measurements during induction of anesthesia
Purpose Several factors affect the accuracy of non-invasive continuous hemoglobin concentration (SpHb) measurements. We had previously shown an increase in the perfusion index (PI) following induction of anesthesia which was associated with an increase in the difference between SpHb and total hemoglobin (tHb) (SpHb–tHb). We hypothesized that blunting the increase in PI by maintaining blood pressure during induction of anesthesia would improve the agreement between SpHb and tHb measurements. Methods Twenty-nine adult patients were enrolled. Patients were randomly assigned by use of sequentially numbered, opaque sealed envelopes to a control (group C) or a phenylephrine group (group P). Anesthesia was induced and maintained with propofol, remifentanil, and ketamine. In group P, phenylephrine was infused at 0.5 µg/kg/min during induction of anesthesia. SpHb and PI were monitored with a Radical-7 Pulse CO-Oximeter. tHb and hematocrit were measured with the ABL800 blood gas analyzer. Results Following induction of anesthesia, PI increased significantly in both groups (p < 0.001 and p < 0.05 in groups C and P, respectively). However, the increase in PI was significantly smaller in group P than in group C (2.6 ± 1.3 vs 0.8 ± 1.4%, p < 0.001). Similarly, the change in SpHb–tHb was significantly smaller in group P than in group C (0.40 ± 0.78 vs 0.97 ± 0.70 g/dl, p < 0.05). Changes in SpHb–tHb are correlated with changes in PI (r = 0.46, p < 0.05). Conclusions The findings suggest that blunting the increase in PI by maintaining arterial pressure during induction of anesthesia improves the agreement between SpHb and tHb values.
- 29 January 2014
- Published by Springer Nature in Journal of Anesthesia
- Vol. 28 (4) , 631-634
Effects of adding epinephrine on the early systemic absorption kinetics of local anesthetics in abdominal truncal blocks
We evaluated the pharmacokinetics of ropivacaine following rectus sheath block (RSB) and transversus abdominis plane (TAP) block with or without epinephrine. A total of 26 adult patients undergoing lower abdominal surgery with RSB (=RSB trial) and another 26 adult patients undergoing open prostatectomy with TAP block (=TAP trial) were enrolled. Patients were randomly assigned to receive either a mixture of 0.75 % ropivacaine 13.2 mL with 1 % plain lidocaine 6.8 mL (TAP-E(−) and RSB-E(−) groups) or a mixture of 0.75 % ropivacaine 13.2 mL and 1 % lidocaine containing adrenaline (1:100,000) 6.8 mL (TAP-E(+) and RSB-E(+) groups) under general anesthesia. The serum concentrations of ropivacaine were measured using gas chromatography with mass spectrometry. The peak concentration was significantly lower and time to peak concentration was significantly longer in the TAP-E(+) group than in the TAP-E(−) group (P < 0.05 and <0.01, respectively), while there were no significant differences in these parameters between the RSB-E(+) and RSB-E(−) groups. These results indicate that epinephrine attenuates the early phase of local anesthetic absorption from the injected site in TAP blocks, but not RSB.
- 29 January 2014
- Published by Springer Nature in Journal of Anesthesia
- Vol. 28 (4) , 631-634
Effects of adding epinephrine on the early systemic absorption kinetics of local anesthetics in abdominal truncal blocks
We evaluated the pharmacokinetics of ropivacaine following rectus sheath block (RSB) and transversus abdominis plane (TAP) block with or without epinephrine. A total of 26 adult patients undergoing lower abdominal surgery with RSB (=RSB trial) and another 26 adult patients undergoing open prostatectomy with TAP block (=TAP trial) were enrolled. Patients were randomly assigned to receive either a mixture of 0.75 % ropivacaine 13.2 mL with 1 % plain lidocaine 6.8 mL (TAP-E(−) and RSB-E(−) groups) or a mixture of 0.75 % ropivacaine 13.2 mL and 1 % lidocaine containing adrenaline (1:100,000) 6.8 mL (TAP-E(+) and RSB-E(+) groups) under general anesthesia. The serum concentrations of ropivacaine were measured using gas chromatography with mass spectrometry. The peak concentration was significantly lower and time to peak concentration was significantly longer in the TAP-E(+) group than in the TAP-E(−) group (P < 0.05 and <0.01, respectively), while there were no significant differences in these parameters between the RSB-E(+) and RSB-E(−) groups. These results indicate that epinephrine attenuates the early phase of local anesthetic absorption from the injected site in TAP blocks, but not RSB.
- 28 December 2013
- Published by Springer Nature in Journal of Anesthesia
- Vol. 28 (1) , 152-155
Role of regional anesthesia in the enhanced recovery after surgery program
- 28 December 2013
- Published by Springer Nature in Journal of Anesthesia
- Vol. 28 (1) , 152-155
Role of regional anesthesia in the enhanced recovery after surgery program
- 18 December 2013
- Published by Springer Nature in Journal of Anesthesia
- Vol. 28 (4) , 576-579
Plasma ropivacaine concentrations after ultrasound-guided transversus abdominis plane block for open retropubic prostatectomy
Ropivacaine-induced vasoconstriction may affect the early absorption speed of ropivacaine; however, the effects of dose on pharmacokinetics following transversus abdominis plane (TAP) block have not been studied. In this study, we have examined plasma ropivacaine concentrations following TAP block with various ropivacaine concentrations (0.25, 0.5, and 0.75 %). With the approval of our University ethics committee and informed consent, 39 adult patients undergoing open retropubic prostatectomy were enrolled. Patients were randomly assigned to three groups (n = 13 each) receiving TAP block with 20 ml (10 ml each side) of different concentrations of ropivacaine. To determine plasma concentrations, blood samples were drawn before and 15, 30, 45, 60, 90, 120, and 180 min after completion of bilateral TAP blocks. Plasma ropivacaine concentrations were analyzed by gas chromatography with mass spectrometry. We found that the peak plasma concentrations (C max) increased dose dependently (0.41 ± 0.14, 0.89 ± 0.55, and 1.56 ± 0.50 µg/ml), but the times to C max (23.0 ± 15.8, 23.1 ± 14.5, and 20.8 ± 11.5 min) were not different between 0.25, 0.5, and 0.75 % ropivacaine doses, respectively. Terminal elimination half-life (t 1/2), total body clearance (CL), and distribution volume (V d) were also not different among the three groups. Ropivacaine concentration did not alter pharmacokinetic profile following TAP blocks.
- 18 December 2013
- Published by Springer Nature in Journal of Anesthesia
- Vol. 28 (4) , 576-579
Plasma ropivacaine concentrations after ultrasound-guided transversus abdominis plane block for open retropubic prostatectomy
Ropivacaine-induced vasoconstriction may affect the early absorption speed of ropivacaine; however, the effects of dose on pharmacokinetics following transversus abdominis plane (TAP) block have not been studied. In this study, we have examined plasma ropivacaine concentrations following TAP block with various ropivacaine concentrations (0.25, 0.5, and 0.75 %). With the approval of our University ethics committee and informed consent, 39 adult patients undergoing open retropubic prostatectomy were enrolled. Patients were randomly assigned to three groups (n = 13 each) receiving TAP block with 20 ml (10 ml each side) of different concentrations of ropivacaine. To determine plasma concentrations, blood samples were drawn before and 15, 30, 45, 60, 90, 120, and 180 min after completion of bilateral TAP blocks. Plasma ropivacaine concentrations were analyzed by gas chromatography with mass spectrometry. We found that the peak plasma concentrations (C max) increased dose dependently (0.41 ± 0.14, 0.89 ± 0.55, and 1.56 ± 0.50 µg/ml), but the times to C max (23.0 ± 15.8, 23.1 ± 14.5, and 20.8 ± 11.5 min) were not different between 0.25, 0.5, and 0.75 % ropivacaine doses, respectively. Terminal elimination half-life (t 1/2), total body clearance (CL), and distribution volume (V d) were also not different among the three groups. Ropivacaine concentration did not alter pharmacokinetic profile following TAP blocks.