    Digitally Assisted Training System for Home-Based Scoliosis Therapy: Proof-of-Concept and Technical Verification Study

    by Florian Günther, Sandra Hunger, Michael Werner, Nikolaus Landerer, Christoph-Eckhard Heyde, Welf-Guntram Drossel

    Background: Schroth therapy is one of the conservative methods used to treat scoliosis. It includes not only therapeutic exercises in physiotherapy facilities but also concepts for independent training at home. Consistent and correct performance of this training has a major impact on the success of the therapy. However, without guidance and supervision by a therapist, patient motivation may decline. In addition, incorrect training techniques may be used, which can have a negative impact on the success of the therapy. Objective: This study aimed to develop a digitally assisted training system for home-based scoliosis therapy and to verify it technically on a laboratory scale. Methods: On the basis of training devices used in Schroth therapy, such as mirrors, balance boards, wall bars, and exercise sticks, we developed a concept for a modular, digitally assisted scoliosis training system (iScoolio). The development process included a requirements specification, iterative design drafts, and the transfer of the concepts into a functional demonstrator. Finally, a theoretical evaluation of the use cases and a technical verification of the measurement functions were carried out using specifically developed test scenarios. Results: A demonstrator with tracking, training, and modification functions was developed, consisting of 4 modules. Technical verification of the integrated measurement functions showed that the angle measurement in motion tracking (n=50) had a mean deviation of 2.29° (SD 1.66°) compared to the ARAMIS 3D optical reference system. Respiration tracking enabled the detection of all simulated respiratory cycles (n=40) and the significant distinction between shallow and deep breathing ( t 39 =−27.4; P <.001). The investigation of the 2 force sensor concepts in the handles ( χ ² 2 =80.0; P <.001) and supporting feet ( χ ² 2 =50.0; P <.001) showed a significant differentiation between 3 force levels, but approximately linear drift behavior in each case. When tracking the stance width (n=50), the mean value was 15.4 (SD 0.54) cm. Verification of the center of pressure measurement function (n=50) showed that 48% of the measurements had a deviation of ≤10 mm, and 82% of the measurements had a deviation of ≤20 mm. Conclusions: In this paper, we have presented the iScoolio concept, which has the potential to support home-based scoliosis therapy through adaptable devices and tracking elements. Integrated sensors enable monitoring of movements, breathing, forces, and pressure distribution during training. An associated web application visualizes the recorded data and serves as a guide for performing the exercises. Technical verification indicates that the integrated tracking methods are functional; however, there is still room for optimization in terms of hardware and software. Further validation is required before conducting clinical trials under real-world conditions.

  • Open Access

    Influence of a Modified Procedure of Joining Ceramic Head and Adapter Sleeve on the Stem Taper in Revision: An Experimental Study

    by Sandra Hunger, Christian Rotsch, Florian Günther, Welf-Guntram Drossel, Christoph-Eckhard Heyde

    In revision operations, ceramic heads of modular hip implants can be replaced. As the surface of the stem taper can be damaged, additional adapter sleeves are applied. The components are usually connected manually by the surgeon in a one-step procedure by hammer impacts. In this study, we investigated a two-step joining procedure with reproducible impaction force. First, the adapter sleeve and head were joined quasi-statically with a force of 2 kN using an assembly device. In the second step, these components were applied to the stem taper using a pulse-controlled instrument. For reference, the joints were assembled according to standard conditions using a tensile testing machine. An average pull-off force of 1309 ± 201 N was achieved for the components joined by the instrument, and the average measured values for the components joined by the testing machine were 1290 ± 140 N. All specimens achieved a force >350 N when released and therefore met the acceptance criterion defined for this study. This study showed that a modified procedure in two steps with a defined force has a positive effect on the reproducibility of the measured joining forces compared to previous studies.

  • Open Access

    Evaluating the Feasibility and Reproducibility of a Novel Insertion Method for Modular Acetabular Ceramic Liners

    by Sandra Hunger, Alexander Seidler, Christian Rotsch, Christoph-Eckhard Heyde, Welf-Guntram Drossel

    Modern hip implants have a modular design. In case of wear or other damage it allows surgeons to change the tribological partners, i.e., the acetabular liner and femoral ball. In both revision and primary surgery, the secure joining of the implant components is important for the success of the operation. The two components, namely the ceramic liner and hip cup, are connected via a conical press connection and should be concentrically aligned to avoid chipping. Malseated liners can reduce the life span in situ. The amount of the joining force, which is usually applied via a hammer, depends on the surgeon. In this study, an alternative joining method for acetabular ceramic liners in hip cups was investigated, which intends to make the process more reproducible and thus safer. For this purpose, a handpiece was used to apply a defined force impulse of 4 kN. For the concentric alignment of a ceramic liner in the hip cup, an adapter was developed based on findings via a qualitative finite element (FE) analysis. Insertion and pushout tests of the acetabular cup–liner connection were performed in the laboratory with the new instrument (handpiece with the connected adapter) to evaluate the functionality of the instrument and the reproducibility of the new insertion method. For comparison, liners and acetabular cups were joined using a testing machine according to the standard. The presented results demonstrate the technical proof-of-concept of the new joining method under laboratory conditions. They meet the acceptance criteria of established manufacturers, which proves the equivalency to proven methods for joining modular implant components. To verify the improvement of the new joining method compared to the conventionally used joining method, an application-oriented study with different surgeons and the new joining instrument under clinical conditions is necessary.


  • Open Access

    Improving Home-Based Scoliosis Therapy: Findings From a Web-Based Survey

    by Florian Günther, Fabian Schober, Sandra Hunger, Julia Schellnock, Steffen Derlien, Stefan Schleifenbaum, Welf-Guntram Drossel, Christoph-Eckhard Heyde

    Background: Conservative scoliosis therapy in the form of assisted physiotherapeutic scoliosis exercises is supplemented by self-contained training at home, depending on the approach (eg, Schroth, the Scientific Exercises Approach to Scoliosis). Complex exercises, lack of awareness of the importance of training, and missing supervision by therapists often lead to uncertainty and reduced motivation, which in turn reduces the success of home-based therapy. Increasing digitalization in the health care sector offers opportunities to close this gap. However, research is needed to analyze the requirements and translate the potential of digital tools into concrete solution concepts. Objective: The aim of this study is to evaluate the potential for optimizing home-based scoliosis therapy in terms of motivation, assistive devices, and digital tools. Methods: In collaboration with the Institute of Physiotherapy at the Jena University Hospital, a survey was initiated to address patients with scoliosis and physical therapists. A digital questionnaire was created for each target group and distributed via physiotherapies, scoliosis forums, the Bundesverband für Skoliose Selbsthilfe e. V. newsletter via a link, and a quick response code. The survey collected data on demographics, therapy, exercise habits, motivation, assistive devices, and digital tools. Descriptive statistics were used for evaluation. Results: Of 141 survey participants, 72 (51.1%; n=62, 86.1%, female; n=10, 13.9%, male) patients with scoliosis with an average age of 40 (SD 17.08) years and 30 scoliosis therapists completed the respective questionnaires. The analysis of home-based therapy showed that patients with scoliosis exercise less per week (2 times or less; 45/72, 62.5%) than they are recommended to do by therapists (at least 3 times; 53/72, 73.6%). Patients indicated that their motivation could be increased by practicing together with friends and acquaintances (54/72, 75%), a supporting therapy device (48/72, 66.7%), or a digital profile (46/72, 63.9%). The most important assistive devices, which are comparatively rarely used in home-based therapy, included balance boards (20/72, 27.8%), wall bars (23/72, 31.9%), mirrors (36/72, 50%), and long bars (40/72, 55.6%). Therapists saw the greatest benefit of digital tools for scoliosis therapy in increasing motivation (26/30, 87%), improving home therapy (25/30, 83%), monitoring therapy progress (25/30, 83%), and demonstrating exercise instructions (24/30, 80%). Conclusions: In this study, we investigated whether there is any potential for improvement in home-based scoliosis therapy. For this purpose, using online questionnaires, we asked patients with scoliosis and therapists questions about the following topics: exercise habits, outpatient and home-based therapy, motivation, supportive devices, and digital tools. The results showed that a lack of motivation, suitable training equipment, and tools for self-control leads to a low training workload. From the perspective of the patients surveyed, this problem can be addressed through community training with friends or acquaintances, a supportive therapy device, and digital elements, such as apps, with training instructions and user profiles.


  • Open Access

    Improving Home-Based Scoliosis Therapy: Findings From a Web-Based Survey (Preprint)

    by Florian Günther, Fabian Schober, Sandra Hunger, Julia Schellnock, Steffen Derlien, Stefan Schleifenbaum, Welf-Guntram Drossel, Christoph-Eckhard Heyde

    BACKGROUND Conservative scoliosis therapy in the form of assisted physiotherapeutic scoliosis exercises is supplemented by self-contained training at home, depending on the approach (eg, Schroth, the Scientific Exercises Approach to Scoliosis). Complex exercises, lack of awareness of the importance of training, and missing supervision by therapists often lead to uncertainty and reduced motivation, which in turn reduces the success of home-based therapy. Increasing digitalization in the health care sector offers opportunities to close this gap. However, research is needed to analyze the requirements and translate the potential of digital tools into concrete solution concepts. OBJECTIVE The aim of this study is to evaluate the potential for optimizing home-based scoliosis therapy in terms of motivation, assistive devices, and digital tools. METHODS In collaboration with the Institute of Physiotherapy at the Jena University Hospital, a survey was initiated to address patients with scoliosis and physical therapists. A digital questionnaire was created for each target group and distributed via physiotherapies, scoliosis forums, the Bundesverband für Skoliose Selbsthilfe e. V. newsletter via a link, and a quick response code. The survey collected data on demographics, therapy, exercise habits, motivation, assistive devices, and digital tools. Descriptive statistics were used for evaluation. RESULTS Of 141 survey participants, 72 (51.1%; n=62, 86.1%, female; n=10, 13.9%, male) patients with scoliosis with an average age of 40 (SD 17.08) years and 30 scoliosis therapists completed the respective questionnaires. The analysis of home-based therapy showed that patients with scoliosis exercise less per week (2 times or less; 45/72, 62.5%) than they are recommended to do by therapists (at least 3 times; 53/72, 73.6%). Patients indicated that their motivation could be increased by practicing together with friends and acquaintances (54/72, 75%), a supporting therapy device (48/72, 66.7%), or a digital profile (46/72, 63.9%). The most important assistive devices, which are comparatively rarely used in home-based therapy, included balance boards (20/72, 27.8%), wall bars (23/72, 31.9%), mirrors (36/72, 50%), and long bars (40/72, 55.6%). Therapists saw the greatest benefit of digital tools for scoliosis therapy in increasing motivation (26/30, 87%), improving home therapy (25/30, 83%), monitoring therapy progress (25/30, 83%), and demonstrating exercise instructions (24/30, 80%). CONCLUSIONS In this study, we investigated whether there is any potential for improvement in home-based scoliosis therapy. For this purpose, using online questionnaires, we asked patients with scoliosis and therapists questions about the following topics: exercise habits, outpatient and home-based therapy, motivation, supportive devices, and digital tools. The results showed that a lack of motivation, suitable training equipment, and tools for self-control leads to a low training workload. From the perspective of the patients surveyed, this problem can be addressed through community training with friends or acquaintances, a supportive therapy device, and digital elements, such as apps, with training instructions and user profiles.

  • Open Access

    Position Control and Force Estimation Method for Surgical Forceps Using SMA Actuators and Sensors

    by Dennis Braun, David Weik, Sophia Elsner, Sandra Hunger, Michael Werner, Welf-Guntram Drossel

    Minimally invasive surgery is increasingly used in many medical operations because of the benefits for the patients. However, for the surgeons, accessing the situs through a small incision or natural orifice comes with a reduction of the degrees of freedom of the instrument. Due to friction of the mechanical coupling, the haptic feedback lacks sensitivity that could lead to damage of the tissue. The approach of this work to overcome these problems is to develop a control concept for position control and force estimation with shape memory alloys (SMA) which could offer haptic feedback in a novel handheld instrument. The concept aims to bridge the gap between manually actuated laparoscopic instruments and surgical robots. Nickel-titanium shape memory alloys are used for actuation because of their high specific energy density. The work includes the manufacturing of a functional model as a proof of concept comprising the development of a suitable forceps mechanism and electronic circuit for position control and gripping force measurement, as well as designing an ergonomic user interface with haptic force feedback.


  • Open Access

    Biocompatibility and Inflammatory Potential of Titanium Alloys Cultivated with Human Osteoblasts, Fibroblasts and Macrophages

    by Jana Markhoff, Martin Krogull, Christian Schulze, Christian Rotsch, Sandra Hunger, Rainer Bader

    The biomaterials used to maintain or replace functions in the human body consist mainly of metals, ceramics or polymers. In orthopedic surgery, metallic materials, especially titanium and its alloys, are the most common, due to their excellent mechanical properties, corrosion resistance, and biocompatibility. Aside from the established Ti6Al4V alloy, shape memory materials such as nickel-titanium (NiTi) have risen in importance, but are also discussed because of the adverse effects of nickel ions. These might be reduced by specific surface modifications. In the present in vitro study, the osteoblastic cell line MG-63 as well as primary human osteoblasts, fibroblasts, and macrophages were cultured on titanium alloys (forged Ti6Al4V, additive manufactured Ti6Al4V, NiTi, and Diamond-Like-Carbon (DLC)-coated NiTi) to verify their specific biocompatibility and inflammatory potential. Additive manufactured Ti6Al4V and NiTi revealed the highest levels of metabolic cell activity. DLC-coated NiTi appeared as a suitable surface for cell growth, showing the highest collagen production. None of the implant materials caused a strong inflammatory response. In general, no distinct cell-specific response could be observed for the materials and surface coating used. In summary, all tested titanium alloys seem to be biologically appropriate for application in orthopedic surgery.