Yong Luan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yong Luan has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Lizhong Mu
Key Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education Affiliation, Dalian University of Technology, Dalian, China
5 shared publications - Ying He
School of Energy and Power Engineering, Dalian University of Technology, Dalian, China
4 shared publications - Kai-Rong Qin
Institute of Cardio-Cerebrovascular Medicine, Central Hospital of Dalian University of Technology, Dalian, People’s Republic of China
3 shared publications - Bo Liu
Women and Children’s Hospital of Dalian University of Technology
2 shared publications - Lili Long
Key Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education, School of Energy and Power Engineering, Dalian University of Technology, Dalian 116024, China
2 shared publications - Qing-Zhuo Chi
Key Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education Affiliation, Dalian University of Technology, Dalian, China
2 shared publications
Latest Publications
- Open Access
- 21 November 2025
- Published by Springer Nature in BMC Anesthesiology
- Vol. 25 (1) , 583
A clinical prediction model for postoperative delirium following surgical treatment of femoral fractures in older adult patients: development and validation study
Postoperative delirium (POD) represents a significant postoperative complication in older adult patients undergoing femoral fracture surgery, associated with substantial mortality, extended hospitalization, and heightened healthcare expenditure. This study aimed to develop and validate a clinical model to predict POD in older adult patients with femoral fractures, facilitating early risk identification and targeted interventions. We retrospectively analyzed patients aged ≥ 65 years who underwent femoral surgery at the First Affiliated Hospital of Dalian Medical University from June 2017 to June 2023. Demographic, laboratory, and perioperative data were collected, with POD as the primary outcome. After multivariable logistic regression identified independent predictors, which were incorporated into a nomogram. The cohort was divided into training (70%) and validation (30%) sets. Model performance was assessed by area under the ROC curve (AUC), Hosmer–Lemeshow(HL) test, calibration plots, and decision curve analysis (DCA). The multivariable analysis identified only three independent predictors of postoperative delirium: tranexamic acid use, preoperative glucose levels, and preoperative lymphocyte counts. Among 2,029 patients, POD incidence was 23.8%. Multiple factors were associated with POD in univariable analysis, including history of cerebral infarction, laboratory abnormalities, and perioperative factors. However, multivariable analysis identified only three independent predictors. Notably, tranexamic acid use (adjusted OR = 0.32, 95% CI: 0.24–0.44) and higher preoperative lymphocyte counts (adjusted OR = 0.60, 95% CI: 0.48–0.75) were protective, while elevated preoperative blood glucose increased risk (adjusted OR = 1.41, 95% CI: 1.35–1.49). The model showed strong discrimination (AUC 0.85 training, 0.80 validation) and good calibration (test HL P = 0.385). DCA indicated significant net clinical benefit within probability thresholds of 0.2–0.6. Sensitivity and specificity at the optimal cut-off point (0.257) were 82.4% (95% CI: 80.0%-85.0%) and 75.0% (95% CI: 71.0%-80.0%), respectively. This validated model, integrating multidimensional perioperative factors, enables individualized risk stratification for POD in older adult femoral fracture patients. Key predictors include tranexamic acid use, preoperative glucose, and preoperative lymphocyte counts, supporting early identification and preventive strategies.
- 21 November 2025
- Published by Springer Nature in BMC Anesthesiology
- Vol. 25 (1) , 583
Open AccessA clinical prediction model for postoperative delirium following surgical treatment of femoral fractures in older adult patients: development and validation study
Postoperative delirium (POD) represents a significant postoperative complication in older adult patients undergoing femoral fracture surgery, associated with substantial mortality, extended hospitalization, and heightened healthcare expenditure. This study aimed to develop and validate a clinical model to predict POD in older adult patients with femoral fractures, facilitating early risk identification and targeted interventions. We retrospectively analyzed patients aged ≥ 65 years who underwent femoral surgery at the First Affiliated Hospital of Dalian Medical University from June 2017 to June 2023. Demographic, laboratory, and perioperative data were collected, with POD as the primary outcome. After multivariable logistic regression identified independent predictors, which were incorporated into a nomogram. The cohort was divided into training (70%) and validation (30%) sets. Model performance was assessed by area under the ROC curve (AUC), Hosmer–Lemeshow(HL) test, calibration plots, and decision curve analysis (DCA). The multivariable analysis identified only three independent predictors of postoperative delirium: tranexamic acid use, preoperative glucose levels, and preoperative lymphocyte counts. Among 2,029 patients, POD incidence was 23.8%. Multiple factors were associated with POD in univariable analysis, including history of cerebral infarction, laboratory abnormalities, and perioperative factors. However, multivariable analysis identified only three independent predictors. Notably, tranexamic acid use (adjusted OR = 0.32, 95% CI: 0.24–0.44) and higher preoperative lymphocyte counts (adjusted OR = 0.60, 95% CI: 0.48–0.75) were protective, while elevated preoperative blood glucose increased risk (adjusted OR = 1.41, 95% CI: 1.35–1.49). The model showed strong discrimination (AUC 0.85 training, 0.80 validation) and good calibration (test HL P = 0.385). DCA indicated significant net clinical benefit within probability thresholds of 0.2–0.6. Sensitivity and specificity at the optimal cut-off point (0.257) were 82.4% (95% CI: 80.0%-85.0%) and 75.0% (95% CI: 71.0%-80.0%), respectively. This validated model, integrating multidimensional perioperative factors, enables individualized risk stratification for POD in older adult femoral fracture patients. Key predictors include tranexamic acid use, preoperative glucose, and preoperative lymphocyte counts, supporting early identification and preventive strategies.
- Open Access
- 27 October 2025
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1704679
Ultrasound-responsive phase-transitional nanomedicine enables intensity-tunable postoperative analgesia
Introduction: Effective handling of pain after surgery is a major clinical issue, since insufficient pain relief is associated with extended recovery, excessive opioid use, and increased healthcare. Current approaches are limited by the short duration of local anesthetics, opioid-related adverse effects, and the lack of dynamic adjustability in pain relief. Here we report a theranostic nanoplatform, Rg3-liposomes@DMSN-levobupivacaine-PFP (RDLP), which integrates ultrasound-triggered phase transition, contrast-enhanced ultrasound (CEUS) imaging, and intensity-tunable drug release to address these limitations. Methods: RDLP features a core-shell architecture: dendritic mesoporous silica nanoparticles (DMSN) encapsulate the local anesthetic levobupivacaine and the phase-transition agent perfluoropentane (PFP), with a biocompatible Rg3-liposome coating enhancing stability and reducing drug leakage. Upon ultrasound irradiation, PFP undergoes liquid-to-gas phase transition, generating microbubbles that amplify CEUS signals for real-time visualization of drug distribution and drive inertial cavitation to trigger burst release of levobupivacaine. This design achieves high levobupivacaine encapsulation efficiency and enables spatiotemporally controlled release, with ultrasound accelerating drug release kinetics in vitro . Results: RDLP combined with ultrasound prolonged analgesia compared to free levobupivacaine and enabled on-demand adjustment of pain relief intensity via multiple ultrasound irradiation cycles, restoring paw withdrawal thresholds and latencies to near-baseline levels in vivo . The platform exhibits exceptional biocompatibility, with no histopathological damage to sciatic nerves. Discussion: RDLP bridges imaging guidance and therapeutic intervention, leveraging ultrasound’s deep tissue penetration and Rg3’s natural biocompatibility to overcome limitations of conventional nerve blocks and ultrasound-responsive systems. This non-invasive, adjustable strategy offering potential to reduce opioid reliance and improve patient outcomes in perioperative care.
- 27 October 2025
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1704679
Open AccessUltrasound-responsive phase-transitional nanomedicine enables intensity-tunable postoperative analgesia
Introduction: Effective handling of pain after surgery is a major clinical issue, since insufficient pain relief is associated with extended recovery, excessive opioid use, and increased healthcare. Current approaches are limited by the short duration of local anesthetics, opioid-related adverse effects, and the lack of dynamic adjustability in pain relief. Here we report a theranostic nanoplatform, Rg3-liposomes@DMSN-levobupivacaine-PFP (RDLP), which integrates ultrasound-triggered phase transition, contrast-enhanced ultrasound (CEUS) imaging, and intensity-tunable drug release to address these limitations. Methods: RDLP features a core-shell architecture: dendritic mesoporous silica nanoparticles (DMSN) encapsulate the local anesthetic levobupivacaine and the phase-transition agent perfluoropentane (PFP), with a biocompatible Rg3-liposome coating enhancing stability and reducing drug leakage. Upon ultrasound irradiation, PFP undergoes liquid-to-gas phase transition, generating microbubbles that amplify CEUS signals for real-time visualization of drug distribution and drive inertial cavitation to trigger burst release of levobupivacaine. This design achieves high levobupivacaine encapsulation efficiency and enables spatiotemporally controlled release, with ultrasound accelerating drug release kinetics in vitro . Results: RDLP combined with ultrasound prolonged analgesia compared to free levobupivacaine and enabled on-demand adjustment of pain relief intensity via multiple ultrasound irradiation cycles, restoring paw withdrawal thresholds and latencies to near-baseline levels in vivo . The platform exhibits exceptional biocompatibility, with no histopathological damage to sciatic nerves. Discussion: RDLP bridges imaging guidance and therapeutic intervention, leveraging ultrasound’s deep tissue penetration and Rg3’s natural biocompatibility to overcome limitations of conventional nerve blocks and ultrasound-responsive systems. This non-invasive, adjustable strategy offering potential to reduce opioid reliance and improve patient outcomes in perioperative care.
- Open Access
- 9 December 2022
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 13 (4) , 290
Experimental Study of the Propagation Process of Dissection Using an Aortic Silicone Phantom
Background: The mortality of acute aortic dissection (AD) can reach 65~70%. However, it is challenging to follow the progress of AD formation. The purpose of this work was to observe the process of dissection development using a novel tear-embedded silicone phantom. Methods: Silicone phantoms were fabricated by embedding a torn area and primary tear feature on the inner layer. CT scanning and laser lightening were conducted to observe the variations in thickness and volume of the true lumen (TL) and false lumen (FL) during development. Results: The model with a larger interlayer adhesion damage required a lower pressure to trigger the development of dissection. At the initiation stage of dissection, the volume of TL increased by 25.5%, accompanied by a 19.5% enlargement of tear size. The force analysis based on the change of tear size verified the deduction of the process of interlaminar separation from the earlier studies. Conclusions: The primary tear and the weakening adhesion of the vessel layers are key factors in AD development, suggesting that some forms of primary damage to the arterial wall, in particular, the lumen morphology of vessels with straight inner lumen, should be considered as early risk predictors of AD.
- 9 December 2022
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 13 (4) , 290
Open AccessExperimental Study of the Propagation Process of Dissection Using an Aortic Silicone Phantom
Background: The mortality of acute aortic dissection (AD) can reach 65~70%. However, it is challenging to follow the progress of AD formation. The purpose of this work was to observe the process of dissection development using a novel tear-embedded silicone phantom. Methods: Silicone phantoms were fabricated by embedding a torn area and primary tear feature on the inner layer. CT scanning and laser lightening were conducted to observe the variations in thickness and volume of the true lumen (TL) and false lumen (FL) during development. Results: The model with a larger interlayer adhesion damage required a lower pressure to trigger the development of dissection. At the initiation stage of dissection, the volume of TL increased by 25.5%, accompanied by a 19.5% enlargement of tear size. The force analysis based on the change of tear size verified the deduction of the process of interlaminar separation from the earlier studies. Conclusions: The primary tear and the weakening adhesion of the vessel layers are key factors in AD development, suggesting that some forms of primary damage to the arterial wall, in particular, the lumen morphology of vessels with straight inner lumen, should be considered as early risk predictors of AD.
- Open Access
- 27 October 2022
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 13 (4) , 205
Lingering Dynamics of Type 2 Diabetes Mellitus Red Blood Cells in Retinal Arteriolar Bifurcations
It has been proven that the deformability of red blood cells (RBC) is reduced owing to changes in mechanical properties, such as diabetes mellitus and hypertension. To probe the effects of RBC morphological and physical parameters on the flow field in bifurcated arterioles, three types of RBC models with various degrees of biconcave shapes were built based on the in vitro experimental data. The dynamic behaviors of the RBCs in shear flow were simulated to validate the feasibility of the finite element-Arbitrary Lagrangian–Eulerian method with a moving mesh. The influences of the shear rate and viscosity ratios on RBC motions were investigated. The motion of RBCs in arteriolar bifurcations was further simulated. Abnormal variations in the morphological and physical parameters of RBCs may lead to diminished tank-tread motion and enhanced tumbling motion in shear flow. Moreover, abnormal RBC variations can result in slower RBC motion at the bifurcation with a longer transmit time and greater flow resistance, which may further cause inadequate local oxygen supply. These findings would provide useful insights into the microvascular complications in diabetes mellitus.
- 27 October 2022
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 13 (4) , 205
Open AccessLingering Dynamics of Type 2 Diabetes Mellitus Red Blood Cells in Retinal Arteriolar Bifurcations
It has been proven that the deformability of red blood cells (RBC) is reduced owing to changes in mechanical properties, such as diabetes mellitus and hypertension. To probe the effects of RBC morphological and physical parameters on the flow field in bifurcated arterioles, three types of RBC models with various degrees of biconcave shapes were built based on the in vitro experimental data. The dynamic behaviors of the RBCs in shear flow were simulated to validate the feasibility of the finite element-Arbitrary Lagrangian–Eulerian method with a moving mesh. The influences of the shear rate and viscosity ratios on RBC motions were investigated. The motion of RBCs in arteriolar bifurcations was further simulated. Abnormal variations in the morphological and physical parameters of RBCs may lead to diminished tank-tread motion and enhanced tumbling motion in shear flow. Moreover, abnormal RBC variations can result in slower RBC motion at the bifurcation with a longer transmit time and greater flow resistance, which may further cause inadequate local oxygen supply. These findings would provide useful insights into the microvascular complications in diabetes mellitus.
- Open Access
- 21 September 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Effects of a Short-Term Left Ventricular Assist Device on Hemodynamics in a Heart Failure Patient-Specific Aorta Model: A CFD Study
Patients with heart failure (HF) or undergoing cardiogenic shock and percutaneous coronary intervention require short-term cardiac support. Short-term cardiac support using a left ventricular assist device (LVAD) alters the pressure and flows of the vasculature by enhancing perfusion and improving the hemodynamic performance for the HF patients. However, due to the position of the inflow and outflow of the LVAD, the local hemodynamics within the aorta is altered with the LVAD support. Specifically, blood velocity, wall shear stress, and pressure difference are altered within the aorta. In this study, computational fluid dynamics (CFD) was used to elucidate the effects of a short-term LVAD for hemodynamic performance in a patient-specific aorta model. The three-dimensional (3D) geometric models of a patient-specific aorta and a short-term LVAD, Impella CP, were created. Velocity, wall shear stress, and pressure difference in the patient-specific aorta model with the Impella CP assistance were calculated and compared with the baseline values of the aorta without Impella CP support. Impella CP support augmented cardiac output, blood velocity, wall shear stress, and pressure difference in the aorta. The proposed CFD study could analyze the quantitative changes in the important hemodynamic parameters while considering the effects of Impella CP, and provide a scientific basis for further predicting and assessing the effects of these hemodynamic signals on the aorta.
- 21 September 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Open AccessEffects of a Short-Term Left Ventricular Assist Device on Hemodynamics in a Heart Failure Patient-Specific Aorta Model: A CFD Study
Patients with heart failure (HF) or undergoing cardiogenic shock and percutaneous coronary intervention require short-term cardiac support. Short-term cardiac support using a left ventricular assist device (LVAD) alters the pressure and flows of the vasculature by enhancing perfusion and improving the hemodynamic performance for the HF patients. However, due to the position of the inflow and outflow of the LVAD, the local hemodynamics within the aorta is altered with the LVAD support. Specifically, blood velocity, wall shear stress, and pressure difference are altered within the aorta. In this study, computational fluid dynamics (CFD) was used to elucidate the effects of a short-term LVAD for hemodynamic performance in a patient-specific aorta model. The three-dimensional (3D) geometric models of a patient-specific aorta and a short-term LVAD, Impella CP, were created. Velocity, wall shear stress, and pressure difference in the patient-specific aorta model with the Impella CP assistance were calculated and compared with the baseline values of the aorta without Impella CP support. Impella CP support augmented cardiac output, blood velocity, wall shear stress, and pressure difference in the aorta. The proposed CFD study could analyze the quantitative changes in the important hemodynamic parameters while considering the effects of Impella CP, and provide a scientific basis for further predicting and assessing the effects of these hemodynamic signals on the aorta.
- 16 February 2021
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 12 (2) , 250
Correction to: A Brush–Spin–Coating Method for Fabricating In Vitro Patient-Specific Vascular Models by Coupling 3D-Printing
- 16 February 2021
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 12 (2) , 250
Correction to: A Brush–Spin–Coating Method for Fabricating In Vitro Patient-Specific Vascular Models by Coupling 3D-Printing
- 2 December 2020
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 12 (2) , 200-214
A Brush–Spin–Coating Method for Fabricating In Vitro Patient-Specific Vascular Models by Coupling 3D-Printing
Purpose In vitro patient-specific flexible vascular models are helpful for understanding the haemodynamic changes before and after endovascular treatment and for effective training of neuroendovascular interventionalists. However, it is difficult to fabricate models of overall unified or controllable thickness using existing manufacturing methods. In this study, we developed an improved and easily implemented method by combining 3D printing and brush-spin–coating processes to produce a transparent silicone model of uniform or varied thickness. Methods First, a water-soluble inner-skeleton model, based on clinical data, was printed on a 3D printer. The skeleton model was subsequently fixed in a single-axis-rotation machine to enable continuous coating of silicone, the thickness of which was manually controlled by adsorption and removal of excess silicone in a brush-spinning operation. After the silicone layer was solidified, the inner skeleton was further dissolved in a hot water bath, affording a transparent vascular model with real geometry. To verify the controllability of the coating thickness by using this method, a straight tube, an idealised aneurysm model, a patient-specific aortic arch model, and an abdominal aortic aneurysm model were manufactured. Results The different thicknesses of the manufactured tubes could be well controlled, with the relative standard deviations being 5.6 and 8.1% for the straight and aneurysm tubes, respectively. Despite of the diameter changing from 33 to 20 mm in the patient-specific aorta, the thickness of the fabricated aortic model remains almost the same along the longitudinal direction with a lower standard deviation of 3.1%. In the more complex patient-specific abdominal aneurysm model, varied thicknesses were realized to mimic the measured data from the CT images, where the middle of the aneurysm was with 2 mm and abdominal aorta as well as the iliac arteries had the normal thickness of 2.3 mm. Conclusion Through the brush–spin–coating method, models of different sizes and complexity with prescribed thickness can be manufactured, which will be helpful for developing surgical treatment strategies or training neuroendovascular interventionalists.
- 2 December 2020
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 12 (2) , 200-214
A Brush–Spin–Coating Method for Fabricating In Vitro Patient-Specific Vascular Models by Coupling 3D-Printing
Purpose In vitro patient-specific flexible vascular models are helpful for understanding the haemodynamic changes before and after endovascular treatment and for effective training of neuroendovascular interventionalists. However, it is difficult to fabricate models of overall unified or controllable thickness using existing manufacturing methods. In this study, we developed an improved and easily implemented method by combining 3D printing and brush-spin–coating processes to produce a transparent silicone model of uniform or varied thickness. Methods First, a water-soluble inner-skeleton model, based on clinical data, was printed on a 3D printer. The skeleton model was subsequently fixed in a single-axis-rotation machine to enable continuous coating of silicone, the thickness of which was manually controlled by adsorption and removal of excess silicone in a brush-spinning operation. After the silicone layer was solidified, the inner skeleton was further dissolved in a hot water bath, affording a transparent vascular model with real geometry. To verify the controllability of the coating thickness by using this method, a straight tube, an idealised aneurysm model, a patient-specific aortic arch model, and an abdominal aortic aneurysm model were manufactured. Results The different thicknesses of the manufactured tubes could be well controlled, with the relative standard deviations being 5.6 and 8.1% for the straight and aneurysm tubes, respectively. Despite of the diameter changing from 33 to 20 mm in the patient-specific aorta, the thickness of the fabricated aortic model remains almost the same along the longitudinal direction with a lower standard deviation of 3.1%. In the more complex patient-specific abdominal aneurysm model, varied thicknesses were realized to mimic the measured data from the CT images, where the middle of the aneurysm was with 2 mm and abdominal aorta as well as the iliac arteries had the normal thickness of 2.3 mm. Conclusion Through the brush–spin–coating method, models of different sizes and complexity with prescribed thickness can be manufactured, which will be helpful for developing surgical treatment strategies or training neuroendovascular interventionalists.
- 1 October 2017
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 89, 236-247
Numerical analysis of wall shear stress in ascending aorta before tearing in type A aortic dissection
- 1 October 2017
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 89, 236-247
Numerical analysis of wall shear stress in ascending aorta before tearing in type A aortic dissection
- Open Access
- 28 December 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (S2) , 154
A multi-component parallel-plate flow chamber system for studying the effect of exercise-induced wall shear stress on endothelial cells
In vivo studies have demonstrated that reasonable exercise training can improve endothelial function. To confirm the key role of wall shear stress induced by exercise on endothelial cells, and to understand how wall shear stress affects the structure and the function of endothelial cells, it is crucial to design and fabricate an in vitro multi-component parallel-plate flow chamber system which can closely replicate exercise-induced wall shear stress waveforms in artery. The in vivo wall shear stress waveforms from the common carotid artery of a healthy volunteer in resting and immediately after 30 min acute aerobic cycling exercise were first calculated by measuring the inner diameter and the center-line blood flow velocity with a color Doppler ultrasound. According to the above in vivo wall shear stress waveforms, we designed and fabricated a parallel-plate flow chamber system with appropriate components based on a lumped parameter hemodynamics model. To validate the feasibility of this system, human umbilical vein endothelial cells (HUVECs) line were cultured within the parallel-plate flow chamber under abovementioned two types of wall shear stress waveforms and the intracellular actin microfilaments and nitric oxide (NO) production level were evaluated using fluorescence microscope. Our results show that the trends of resting and exercise-induced wall shear stress waveforms, especially the maximal, minimal and mean wall shear stress as well as oscillatory shear index, generated by the parallel-plate flow chamber system are similar to those acquired from the common carotid artery. In addition, the cellular experiments demonstrate that the actin microfilaments and the production of NO within cells exposed to the two different wall shear stress waveforms exhibit different dynamic behaviors; there are larger numbers of actin microfilaments and higher level NO in cells exposed in exercise-induced wall shear stress condition than resting wall shear stress condition. The parallel-plate flow chamber system can well reproduce wall shear stress waveforms acquired from the common carotid artery in resting and immediately after exercise states. Furthermore, it can be used for studying the endothelial cells responses under resting and exercise-induced wall shear stress environments in vitro.
- 28 December 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (S2) , 154
Open AccessA multi-component parallel-plate flow chamber system for studying the effect of exercise-induced wall shear stress on endothelial cells
In vivo studies have demonstrated that reasonable exercise training can improve endothelial function. To confirm the key role of wall shear stress induced by exercise on endothelial cells, and to understand how wall shear stress affects the structure and the function of endothelial cells, it is crucial to design and fabricate an in vitro multi-component parallel-plate flow chamber system which can closely replicate exercise-induced wall shear stress waveforms in artery. The in vivo wall shear stress waveforms from the common carotid artery of a healthy volunteer in resting and immediately after 30 min acute aerobic cycling exercise were first calculated by measuring the inner diameter and the center-line blood flow velocity with a color Doppler ultrasound. According to the above in vivo wall shear stress waveforms, we designed and fabricated a parallel-plate flow chamber system with appropriate components based on a lumped parameter hemodynamics model. To validate the feasibility of this system, human umbilical vein endothelial cells (HUVECs) line were cultured within the parallel-plate flow chamber under abovementioned two types of wall shear stress waveforms and the intracellular actin microfilaments and nitric oxide (NO) production level were evaluated using fluorescence microscope. Our results show that the trends of resting and exercise-induced wall shear stress waveforms, especially the maximal, minimal and mean wall shear stress as well as oscillatory shear index, generated by the parallel-plate flow chamber system are similar to those acquired from the common carotid artery. In addition, the cellular experiments demonstrate that the actin microfilaments and the production of NO within cells exposed to the two different wall shear stress waveforms exhibit different dynamic behaviors; there are larger numbers of actin microfilaments and higher level NO in cells exposed in exercise-induced wall shear stress condition than resting wall shear stress condition. The parallel-plate flow chamber system can well reproduce wall shear stress waveforms acquired from the common carotid artery in resting and immediately after exercise states. Furthermore, it can be used for studying the endothelial cells responses under resting and exercise-induced wall shear stress environments in vitro.
- Open Access
- 22 November 2016
- Published by MDPI AG in Preprints.org
A Y-Shaped Microfluidic Device to Study the Combined Effect of Wall Shear Stress and ATP Signals on Intracellular Calcium Dynamics in Vascular Endothelial Cells
The intracellular calcium dynamics in vascular endothelial cells (VECs) in response to wall shear stress (WSS) and/or adenosine triphosphate (ATP) have been commonly regarded as an important factor in regulating VEC function and behavior including proliferation, migration and apoptosis. However, the effects of time-varying ATP signals have been usually neglected in the past investigations in the field of VEC mechanobiology. In order to investigate the combined effects of WSS and dynamic ATP signals on the intracellular calcium dynamic in VECs, a Y-shaped microfluidic device, which can provide the cultured cells on the bottom of its mixing micro-channel with stimuli of WSS signal alone and different combinations of WSS and ATP signals in one single micro-channel, is proposed. Both numerical simulation and experimental studies verify the feasibility of its application. Cellular experimental results also suggest that a combination of WSS and ATP signals rather than a WSS signal alone might play a more significant role in VEC Ca2+ signal transduction induced by blood flow.
- 22 November 2016
- Published by MDPI AG in Preprints.org
Open AccessA Y-Shaped Microfluidic Device to Study the Combined Effect of Wall Shear Stress and ATP Signals on Intracellular Calcium Dynamics in Vascular Endothelial Cells
The intracellular calcium dynamics in vascular endothelial cells (VECs) in response to wall shear stress (WSS) and/or adenosine triphosphate (ATP) have been commonly regarded as an important factor in regulating VEC function and behavior including proliferation, migration and apoptosis. However, the effects of time-varying ATP signals have been usually neglected in the past investigations in the field of VEC mechanobiology. In order to investigate the combined effects of WSS and dynamic ATP signals on the intracellular calcium dynamic in VECs, a Y-shaped microfluidic device, which can provide the cultured cells on the bottom of its mixing micro-channel with stimuli of WSS signal alone and different combinations of WSS and ATP signals in one single micro-channel, is proposed. Both numerical simulation and experimental studies verify the feasibility of its application. Cellular experimental results also suggest that a combination of WSS and ATP signals rather than a WSS signal alone might play a more significant role in VEC Ca2+ signal transduction induced by blood flow.