ASAnna M. Sailer

Anna M. Sailer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anna M. Sailer has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 18F-FDG PET/MRI in the diagnosis of an infected aortic aneurysm

    by Anna M. Sailer, Frans C. Bakers, Jan W. Daemen, Stefan Vöö

    We report a case where an integrated whole body 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/magnetic resonance imaging (MRI) is performed in the diagnostic work-up of a saccular aortic aneurysm. The integrated whole body 18F-FDG PET/MRI study answered all relevant diagnostic questions, clearly marking an infected aortic aneurysm, depicting the extent of the infected area in relation to the aortic branch vessels, and indicating the aortic lesion as the primary site of infection. The patient was successfully treated by open type V TAAA repair and pericardial graft replacement. Aortic wall infection was proven in cultures of the surgical specimen.


  • Open Access

    Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice

    by Anna M. Sailer, Leonie Paulis, Laura Vergoossen, Axel O. Kovac, Geert Wijnhoven, Geert Willem H. Schurink, Barend Mees, Marco Das, Joachim E. Wildberger, Michiel W. de Haan, et al.

    Purpose Knowledge of medical radiation exposure permits application of radiation protection principles. In our center, the first dedicated real-time, automated patient and staff dose monitoring system (DoseWise Portal, Philips Healthcare) was installed. Aim of this study was to obtain insight in the procedural and occupational doses. Materials and Methods All interventional radiologists, vascular surgeons, and technicians wore personal dose meters (PDMs, DoseAware, Philips Healthcare). The dose monitoring system simultaneously registered for each procedure dose-related data as the dose area product (DAP) and effective staff dose (E) from PDMs. Use and type of shielding were recorded separately. All procedures were analyzed according to procedure type; these included among others cerebral interventions (n = 112), iliac and/or caval venous recanalization procedures (n = 68), endovascular aortic repair procedures (n = 63), biliary duct interventions (n = 58), and percutaneous gastrostomy procedure (n = 28). Results Median (±IQR) DAP doses ranged from 2.0 (0.8–3.1) (percutaneous gastrostomy) to 84 (53–147) Gy cm2 (aortic repair procedures). Median (±IQR) first operator doses ranged from 1.6 (1.1–5.0) μSv to 33.4 (12.1–125.0) for these procedures, respectively. The relative exposure, determined as first operator dose normalized to procedural DAP, ranged from 1.9 in biliary interventions to 0.1 μSv/Gy cm2 in cerebral interventions, indicating large variation in staff dose per unit DAP among the procedure types. Conclusion Real-time dose monitoring was able to identify the types of interventions with either an absolute or relatively high staff dose, and may allow for specific optimization of radiation protection.


  • Open Access

    Endovascular treatment of complex aortic aneurysms: prevalence of acute kidney injury and effect on long-term renal function

    by Anna M. Sailer, Patricia J. Nelemans, Camille van Berlo, Ozan Yazar, Michiel W. de Haan, Dominik Fleischmann, Geert Willem H. Schurink

    Objectives To analyse predictors for short- and long-term renal function changes after fenestrated and branched endovascular aortic repair (EVAR). Methods A total of 157 patients underwent fenestrated and branched EVAR. Procedural intra-arterial iodinated contrast volume was documented. Serum creatinine and estimated glomerular filtration rate (eGFR) at baseline, during 48 h following EVAR, at discharge and latest moment of follow-up were recorded. Development of post-EVAR acute kidney injury (AKI; according to AKIN criteria), and potential risk factors for renal failure were recorded. Multivariate regression analyses were used to identify independent risk factors for AKI and eGFR decrease during follow-up. Results Forty-three patients (28 %) developed post-EVAR AKI. Long procedure time and occlusion of accessory renal arteries were independent risk factors for development of AKI. (odds ratio (OR) 1.005 per minute, 95 % CI 1.001–1.01; p = 0.025 and OR 3.02, 95 % CI 1.19–8.16; p = 0.029). Post-EVAR AKI was associated with a significantly increased risk for eGFR decrease at discharge and latest follow-up (hazard ratio (HR) 3.47, 95 % CI 1.63–7.36, p = 0.001 and HR 3.01, 95 % CI 1.56–5.80; p = 0.001). Iodinated contrast volume was not an independent risk factor for AKI or eGFR decrease during follow-up. Conclusion Development of post-EVAR AKI is an independent risk factor for long-term renal function decrease. Key Points • Longer procedure time is associated with an increased risk for AKI. • Renal perfusion defects on angiography are associated with increased risk for AKI. • Post-EVAR AKI is associated with higher probability for long-term eGFR decrease. • Iodinated contrast volume is not an independent risk factor for AKI. • Iodinated contrast volume is not an independent risk factor for long-term eGFR decrease.


  • Quantification of Respiratory Movement of the Aorta and Side Branches

    by Anna M. Sailer, Bart A. J. M. Wagemans, Marco Das, Michiel W. de Haan, Patricia J. Nelemans, Joachim E. Wildberger, Geert Willem H. Schurink

    Purpose: To assess and quantify the magnitude and direction of respiratory movement of the aorta and origins of its side branches. Methods: A quantitative 3-dimensional (3D) subtraction analysis of computed tomography (CT) scans during inspiration and expiration was performed to determine the respiratory geometric movements of the aorta and side branches in 60 patients. During breath-hold expiration and inspiration, 1-mm-thick CT slices of the aorta were acquired in unenhanced and contrast-enhanced scans. The datasets were compared using dedicated multiplanar reformation image subtraction software to determine the change in position of relevant anatomic sections, including the ascending thoracic aorta (AA), the origins of the brachiocephalic artery (BA) and left subclavian artery (LSA), the descending thoracic aorta (DTA) at the level of the tenth thoracic vertebra, as well as the origins of the celiac trunk, superior mesenteric artery, and the renal arteries. Results: Complex movement was visible during inspiration; the regions of interest in the thoracic aorta and side branches moved in the anterior, medial, and caudal directions compared with the expiration state. Mean 3D movement vectors (± standard deviation) were 8.9±3.6 mm (AA), 12.0±4.1 mm (BA), 11.1±3.9 mm (LSA), and 4.9±2.5 mm (DTA). Abdominal side branches moved in the caudal direction 1.3±1.1 mm. There was significantly less movement in the DTA compared to AA (p<0.001). The correlation coefficient between the extent of LSA movement and thoracic excursion was 0.78. Conclusion: The aorta and side branches undergo considerable respiratory movement. The results from this study provide an important contribution to understanding aortic dynamics.