Donhee Ham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Donhee Ham has a total of 248 co-authors. Here are the top co-authors by number of shared publications:
- Hongkun Park
Harvard University
12 shared publications - Henry Hinton
Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
8 shared publications Rona S. Gertner
Department of Chemistry and Chemical Biology, Harvard University, Cambridge, USA
8 shared publicationsHan Sae Jung
John A. Paulson School of Engineering and Applied Sciences Harvard University 02138 Cambridge MA USA
5 shared publications- Han Sae Jung
John A. Paulson School of Engineering and Applied Sciences, Harvard University 1 , Cambridge, Massachusetts 02138
5 shared publications Henry Hinton
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, USA
5 shared publications
Latest Publications
- Open Access
- 23 June 2026
- Published by Springer Nature in Research Square
Why intracellular electrodes converge to the microscale
Nanoscale structures have long been pursued for intracellular recording on the premise that smaller electrodes couple more intimately with cells. This vision animated two decades of nano-bio research in electrophysiology, yet experimental reality has told a different story. Robust intracellular recording in neurons, with reliable subthreshold sensitivity, has remained elusive at the nanoscale; where it has been clearly achieved, the effective electrode dimension has been microscale. Here we show that an optimal electrode size arises intrinsically in intracellular recording, from the competition between electrical physics and probabilistic cell-electrode geometry. We then formalize this competition by extending the standard cell-electrode interface model into a generalized probabilistic model that captures both physics and geometry. This model yields an optimum in or near the microscale range under realistic conditions, accounting for the historical convergence toward microscale electrodes. It also provides a practical basis for analyzing and designing intracellular interfaces.
- 23 June 2026
- Published by Springer Nature in Research Square
Open AccessWhy intracellular electrodes converge to the microscale
Nanoscale structures have long been pursued for intracellular recording on the premise that smaller electrodes couple more intimately with cells. This vision animated two decades of nano-bio research in electrophysiology, yet experimental reality has told a different story. Robust intracellular recording in neurons, with reliable subthreshold sensitivity, has remained elusive at the nanoscale; where it has been clearly achieved, the effective electrode dimension has been microscale. Here we show that an optimal electrode size arises intrinsically in intracellular recording, from the competition between electrical physics and probabilistic cell-electrode geometry. We then formalize this competition by extending the standard cell-electrode interface model into a generalized probabilistic model that captures both physics and geometry. This model yields an optimum in or near the microscale range under realistic conditions, accounting for the historical convergence toward microscale electrodes. It also provides a practical basis for analyzing and designing intracellular interfaces.
- 17 June 2026
- Published by Springer Nature in Nature Electronics
- Vol. 9 (8) , 932-940
Parallel enzymatic DNA synthesis using a semiconductor chip
- 17 June 2026
- Published by Springer Nature in Nature Electronics
- Vol. 9 (8) , 932-940
Parallel enzymatic DNA synthesis using a semiconductor chip
- Open Access
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
Two-dimensional adhesion noise spectroscopy: a CMOS-based, non-invasive modality for real-time cell and tissue monitoring
Non-invasive monitoring of adherent cells by adhesion noise spectroscopy without the need of optical imaging or external stimuli for lab-on-chip applications.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
Open AccessTwo-dimensional adhesion noise spectroscopy: a CMOS-based, non-invasive modality for real-time cell and tissue monitoring
Non-invasive monitoring of adherent cells by adhesion noise spectroscopy without the need of optical imaging or external stimuli for lab-on-chip applications.
- 28 July 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (4)
Microwave-regime demonstration of plasmonic non-reciprocity in a flowing two-dimensional electron gas
The speed of a plasmonic wave in the presence of electron drift in a conductor depends on the wave's propagation direction, with the wave traveling along the drift (“forward wave”) faster than the wave traveling against the drift (“backward wave”). Phenomena related to this plasmonic non-reciprocity—which is relatively more pronounced in two-dimensional conductors than in bulk conductors and could lead to solid-state device applications—have been studied in THz and optical spectral regimes. Here, we demonstrate the plasmonic non-reciprocity at microwave frequencies (10–50 GHz). Concretely, we conduct, at 4 K, a microwave network analysis on a gated GaAs two-dimensional electron gas with electron drift (i.e., DC), directly measuring the forward and backward wave speeds via their propagation phase delays. We resolve, for example, forward and backward wave speeds of 4.26×10−3±8.97×10−6 (normalized to the speed of light). Sufficient consistency between the electron drift speed obtained from the microwave measurement and that alternatively estimated by a DC transport theory further confirms the non-reciprocity. We conclude this paper with a discussion on how to enhance the non-reciprocity for real-world applications, where degeneracy pressure would play an important role.
- 28 July 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (4)
Microwave-regime demonstration of plasmonic non-reciprocity in a flowing two-dimensional electron gas
The speed of a plasmonic wave in the presence of electron drift in a conductor depends on the wave's propagation direction, with the wave traveling along the drift (“forward wave”) faster than the wave traveling against the drift (“backward wave”). Phenomena related to this plasmonic non-reciprocity—which is relatively more pronounced in two-dimensional conductors than in bulk conductors and could lead to solid-state device applications—have been studied in THz and optical spectral regimes. Here, we demonstrate the plasmonic non-reciprocity at microwave frequencies (10–50 GHz). Concretely, we conduct, at 4 K, a microwave network analysis on a gated GaAs two-dimensional electron gas with electron drift (i.e., DC), directly measuring the forward and backward wave speeds via their propagation phase delays. We resolve, for example, forward and backward wave speeds of 4.26×10−3±8.97×10−6 (normalized to the speed of light). Sufficient consistency between the electron drift speed obtained from the microwave measurement and that alternatively estimated by a DC transport theory further confirms the non-reciprocity. We conclude this paper with a discussion on how to enhance the non-reciprocity for real-world applications, where degeneracy pressure would play an important role.
- Open Access
Impedance-tuned microwave loop for fast, homogeneous Rabi oscillations of a dense ensemble of NV-diamond electronic spins
Obtaining a high Rabi oscillation frequency homogeneously across a spatially-extended population of nitrogen-vacancy (NV) center electronic spins in diamond is useful for efficient spin-state manipulation of the NV ensemble and in using NVs to detect ensembles of other spin species. Here, we achieve a high, homogeneous Rabi frequency for a dense NV ensemble by enhancing the microwave magnetic fields in the center region of a diamond-coupled planar metallic loop via systematic engineering that increases the microwave current driving of the loop, while avoiding off-center proximity to the loop that gives strong but inhomogeneous microwave fields. With such enhanced microwave fields at 2.55 GHz, we achieve a 136.3 MHz NV Rabi frequency with 1.5% inhomogeneity over a 40 $\times$ 40 $μm^{2}$ diamond area; and use the NV ensemble to detect a ~30-MHz magnetic signal, similar to a nuclear magnetic resonance signal at a tesla-scale bias magnetic field, with Hz-scale spectral resolution.Open AccessImpedance-tuned microwave loop for fast, homogeneous Rabi oscillations of a dense ensemble of NV-diamond electronic spins
Obtaining a high Rabi oscillation frequency homogeneously across a spatially-extended population of nitrogen-vacancy (NV) center electronic spins in diamond is useful for efficient spin-state manipulation of the NV ensemble and in using NVs to detect ensembles of other spin species. Here, we achieve a high, homogeneous Rabi frequency for a dense NV ensemble by enhancing the microwave magnetic fields in the center region of a diamond-coupled planar metallic loop via systematic engineering that increases the microwave current driving of the loop, while avoiding off-center proximity to the loop that gives strong but inhomogeneous microwave fields. With such enhanced microwave fields at 2.55 GHz, we achieve a 136.3 MHz NV Rabi frequency with 1.5% inhomogeneity over a 40 $\times$ 40 $μm^{2}$ diamond area; and use the NV ensemble to detect a ~30-MHz magnetic signal, similar to a nuclear magnetic resonance signal at a tesla-scale bias magnetic field, with Hz-scale spectral resolution. - 11 February 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 9 (7) , 1144-1154
Synaptic connectivity mapping among thousands of neurons via parallelized intracellular recording with a microhole electrode array
The massive parallelization of neuronal intracellular recording, which enables the measurement of synaptic signals across a neuronal network, and thus the mapping and characterization of synaptic connections, is an open challenge, with the state of the art being limited to the mapping of about 300 synaptic connections. Here we report a 4,096 platinum/platinum-black microhole electrode array fabricated on a complementary metal-oxide semiconductor chip for parallel intracellular recording and thus for synaptic-connectivity mapping. The microhole–neuron interface, together with current-clamp electronics in the underlying semiconductor chip, allowed a 90% average intracellular coupling rate in rat neuronal cultures, generating network-wide intracellular-recording data with abundant synaptic signals. From these data, we extracted more than 70,000 plausible synaptic connections among more than 2,000 neurons and catalogued them into electrical synaptic connections and into inhibitory, weak/uneventful excitatory and strong/eventful excitatory chemical synaptic connections, with an estimated overall error rate of about 5%. This scale of synaptic-connectivity mapping and the ability to characterize synaptic connections is a step towards the functional connectivity mapping of large-scale neuronal networks.
- 11 February 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 9 (7) , 1144-1154
Synaptic connectivity mapping among thousands of neurons via parallelized intracellular recording with a microhole electrode array
The massive parallelization of neuronal intracellular recording, which enables the measurement of synaptic signals across a neuronal network, and thus the mapping and characterization of synaptic connections, is an open challenge, with the state of the art being limited to the mapping of about 300 synaptic connections. Here we report a 4,096 platinum/platinum-black microhole electrode array fabricated on a complementary metal-oxide semiconductor chip for parallel intracellular recording and thus for synaptic-connectivity mapping. The microhole–neuron interface, together with current-clamp electronics in the underlying semiconductor chip, allowed a 90% average intracellular coupling rate in rat neuronal cultures, generating network-wide intracellular-recording data with abundant synaptic signals. From these data, we extracted more than 70,000 plausible synaptic connections among more than 2,000 neurons and catalogued them into electrical synaptic connections and into inhibitory, weak/uneventful excitatory and strong/eventful excitatory chemical synaptic connections, with an estimated overall error rate of about 5%. This scale of synaptic-connectivity mapping and the ability to characterize synaptic connections is a step towards the functional connectivity mapping of large-scale neuronal networks.
- Open Access
Microwave-regime demonstration of plasmonic non-reciprocity in a flowing two-dimensional electron gas
The speed of a plasmonic wave in the presence of electron drift in a conductor depends on the wave's propagation direction, with the wave traveling along the drift (`forward wave') faster than the wave traveling against the drift (`backward wave'). Phenomena related to this plasmonic non-reciprocity -- which is relatively more pronounced in two-dimensional conductors than in bulk conductors and could lead to solid-state device applications -- have been studied in THz and optical spectral regimes. Here we demonstrate the plasmonic non-reciprocity at microwave frequencies (10 $\sim$ 50 GHz). Concretely, we conduct, at 4K, a microwave network analysis on a gated GaAs two-dimensional electron gas with electron drift (i.e., DC current), directly measuring out forward and backward wave speeds via their propagation phase delays. We resolve, for example, forward and backward wave speeds of $4.26 \times 10^{-3} \pm 8.97 \times 10^{-6}$ (normalized to the speed of light). Sufficient consistency between the electron drift speed obtained from the microwave measurement and that alternatively estimated by a DC transport theory further confirms the non-reciprocity. We conclude this paper with a discussion on how to enhance the non-reciprocity for real-world applications, where degeneracy pressure would play an important role.Open AccessMicrowave-regime demonstration of plasmonic non-reciprocity in a flowing two-dimensional electron gas
The speed of a plasmonic wave in the presence of electron drift in a conductor depends on the wave's propagation direction, with the wave traveling along the drift (`forward wave') faster than the wave traveling against the drift (`backward wave'). Phenomena related to this plasmonic non-reciprocity -- which is relatively more pronounced in two-dimensional conductors than in bulk conductors and could lead to solid-state device applications -- have been studied in THz and optical spectral regimes. Here we demonstrate the plasmonic non-reciprocity at microwave frequencies (10 $\sim$ 50 GHz). Concretely, we conduct, at 4K, a microwave network analysis on a gated GaAs two-dimensional electron gas with electron drift (i.e., DC current), directly measuring out forward and backward wave speeds via their propagation phase delays. We resolve, for example, forward and backward wave speeds of $4.26 \times 10^{-3} \pm 8.97 \times 10^{-6}$ (normalized to the speed of light). Sufficient consistency between the electron drift speed obtained from the microwave measurement and that alternatively estimated by a DC transport theory further confirms the non-reciprocity. We conclude this paper with a discussion on how to enhance the non-reciprocity for real-world applications, where degeneracy pressure would play an important role. - 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (3) , 577-589
A Cyto-Silicon Hybrid System with On-Chip Closed-Loop Modulation
We introduce a bioelectronic interface between biological electrogenic cells and a mixed-signal CMOS integrated circuit with an array of surface electrodes, where not only is the CMOS electrode array capable of electrophysiological recording and stimulation of the cells with 1,024 recording and stimulation channels, but it can also provide low-latency artificial signal pathways from cells it records to cells it stimulates. This on-chip closed-loop modulation has an intrinsic latency less than 5 μs. To demonstrate the utility of the on-chip closed loop modulation as an artificial feedback pathway between biological cells, we develop a silicon-cardiomyocyte self-sustained oscillator with a tunable frequency to which both the relevant part of the CMOS chip and cells are locked, and also a silicon-neuron interface with a silicon inhibitory connection between neuronal cells. This line of cyto-silicon hybrid system, where the boundary between biological and semiconductor systems is blurred, may find applications in prosthesis, brain-machine interface, and fundamental biology research.
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (3) , 577-589
A Cyto-Silicon Hybrid System with On-Chip Closed-Loop Modulation
We introduce a bioelectronic interface between biological electrogenic cells and a mixed-signal CMOS integrated circuit with an array of surface electrodes, where not only is the CMOS electrode array capable of electrophysiological recording and stimulation of the cells with 1,024 recording and stimulation channels, but it can also provide low-latency artificial signal pathways from cells it records to cells it stimulates. This on-chip closed-loop modulation has an intrinsic latency less than 5 μs. To demonstrate the utility of the on-chip closed loop modulation as an artificial feedback pathway between biological cells, we develop a silicon-cardiomyocyte self-sustained oscillator with a tunable frequency to which both the relevant part of the CMOS chip and cells are locked, and also a silicon-neuron interface with a silicon inhibitory connection between neuronal cells. This line of cyto-silicon hybrid system, where the boundary between biological and semiconductor systems is blurred, may find applications in prosthesis, brain-machine interface, and fundamental biology research.
- Top Cited PapersOpen Access
- 1 September 2024
- Published by AIP Publishing in APL Materials
- Vol. 12 (9)
Roadmap on low-power electronics
R. Ramesh(*rr73@rice.edu) R. Ramesh(*rr73@rice.edu)
- 1 September 2024
- Published by AIP Publishing in APL Materials
- Vol. 12 (9)
Top Cited PapersOpen AccessRoadmap on low-power electronics
R. Ramesh(*rr73@rice.edu) R. Ramesh(*rr73@rice.edu)
- Open Access
- 17 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-9
Anti-distortion bioinspired camera with an inhomogeneous photo-pixel array
The bioinspired camera, comprising a single lens and a curved image sensor—a photodiode array on a curved surface—, was born of flexible electronics. Its economical build lends itself well to space-constrained machine vision applications. The curved sensor, much akin to the retina, helps image focusing, but the curvature also creates a problem of image distortion, which can undermine machine vision tasks such as object recognition. Here we report an anti-distortion single-lens camera, where 4096 silicon photodiodes arrayed on a curved surface in a nonuniform pattern assimilated to the distorting optics are the key to anti-distortion engineering. That is, the photo-pixel distribution pattern itself is warped in the same manner as images are warped, which correctively reverses distortion. Acquired images feature no appreciable distortion across a 120° horizontal view, as confirmed by their neural-network recognition accuracies. This distortion correction via photo-pixel array reconfiguration is a form of in-sensor computing.
- 17 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-9
Open AccessAnti-distortion bioinspired camera with an inhomogeneous photo-pixel array
The bioinspired camera, comprising a single lens and a curved image sensor—a photodiode array on a curved surface—, was born of flexible electronics. Its economical build lends itself well to space-constrained machine vision applications. The curved sensor, much akin to the retina, helps image focusing, but the curvature also creates a problem of image distortion, which can undermine machine vision tasks such as object recognition. Here we report an anti-distortion single-lens camera, where 4096 silicon photodiodes arrayed on a curved surface in a nonuniform pattern assimilated to the distorting optics are the key to anti-distortion engineering. That is, the photo-pixel distribution pattern itself is warped in the same manner as images are warped, which correctively reverses distortion. Acquired images feature no appreciable distortion across a 120° horizontal view, as confirmed by their neural-network recognition accuracies. This distortion correction via photo-pixel array reconfiguration is a form of in-sensor computing.