Berivan Atashkar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Berivan Atashkar has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
E. Jalalian
Associate Professor, Department of Fix Prostodontics, Dental Branch, Azad University, Tehran, Iran
1 shared publicationHossein Heidari
Postgraduate Student in Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
1 shared publicationKianoosh Torabi
Dept. of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
1 shared publicationMahroo Vojdani
Dept. of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
1 shared publicationMahshid Torabi Ardakani
Dept. of Prosthodontics, School of Dentistry, Azad University of Medical Sciences, Tehran, Iran
1 shared publicationR. Rostami
Dentist, Department of Fix Prostodontics, Dental Branch, Azad University, Tehran, Iran
1 shared publication
Latest Publications
- Open Access
- 1 December 2016
- Vol. 17 (4) , 301-308
A Comparison of the Marginal and Internal Fit of Cobalt- Chromium Copings Fabricated by Two Different CAD/CAM Systems (CAD/ Milling, CAD/ Ceramill Sintron)
Marginal fitness is the most important criteria for evaluation of the clinical acceptability of a cast restoration. Marginal gap which is due to cement solubility and plaque retention is potentially detrimental to both tooth and periodontal tissues. This in vitro study aimed to evaluate the marginal and internal fit of cobalt- chromium (Co-Cr) copings fabricated by two different CAD/CAM systems: (CAD/ milling and CAD/ Ceramill Sintron). We prepared one machined standard stainless steel master model with following dimensions: 7 mm height, 5mm diameter, 90˚ shoulder marginal finish line with 1 mm width, 10˚ convergence angle and anti-rotational surface on the buccal aspect of the die. There were 10 copings produced from hard presintered Co-Cr blocks according to CAD/ Milling technique and ten copings from soft non- presintered Co-Cr blocks according to CAD/ Ceramill Sintron technique. Marginal and internal accuracies of copings were documented by the replica technique. Replicas were examined at ten reference points under a digital microscope (230X). The Student's t-test was used for statistical analysis. p< 0.001 was considered significant. Statistically significant differences existed between the groups (p< 0.001). The CAD/milling group (hard copings) had a mean marginal discrepancy (MD) of 104 µm, axial discrepancy (AD) of 23 µm and occlusal discrepancy of 130 µm. For CAD/ Ceramill Sintron group, these values were 195 µm (MD), 46 µm (AD), and 232 µm (OD). Internal total discrepancy (ITD) for the CAD/milling group was 77 µm, whereas for the CAD/Ceramill Sintron group was 143 µm. Hard presintered Co-Cr copings had significantly higher marginal and internal accuracies compared to the soft non-presintered copings.
- 1 December 2016
- Vol. 17 (4) , 301-308
Open AccessA Comparison of the Marginal and Internal Fit of Cobalt- Chromium Copings Fabricated by Two Different CAD/CAM Systems (CAD/ Milling, CAD/ Ceramill Sintron)
Marginal fitness is the most important criteria for evaluation of the clinical acceptability of a cast restoration. Marginal gap which is due to cement solubility and plaque retention is potentially detrimental to both tooth and periodontal tissues. This in vitro study aimed to evaluate the marginal and internal fit of cobalt- chromium (Co-Cr) copings fabricated by two different CAD/CAM systems: (CAD/ milling and CAD/ Ceramill Sintron). We prepared one machined standard stainless steel master model with following dimensions: 7 mm height, 5mm diameter, 90˚ shoulder marginal finish line with 1 mm width, 10˚ convergence angle and anti-rotational surface on the buccal aspect of the die. There were 10 copings produced from hard presintered Co-Cr blocks according to CAD/ Milling technique and ten copings from soft non- presintered Co-Cr blocks according to CAD/ Ceramill Sintron technique. Marginal and internal accuracies of copings were documented by the replica technique. Replicas were examined at ten reference points under a digital microscope (230X). The Student's t-test was used for statistical analysis. p< 0.001 was considered significant. Statistically significant differences existed between the groups (p< 0.001). The CAD/milling group (hard copings) had a mean marginal discrepancy (MD) of 104 µm, axial discrepancy (AD) of 23 µm and occlusal discrepancy of 130 µm. For CAD/ Ceramill Sintron group, these values were 195 µm (MD), 46 µm (AD), and 232 µm (OD). Internal total discrepancy (ITD) for the CAD/milling group was 77 µm, whereas for the CAD/Ceramill Sintron group was 143 µm. Hard presintered Co-Cr copings had significantly higher marginal and internal accuracies compared to the soft non-presintered copings.
- Open Access
- 30 September 2011
- Vol. 8 (3) , 123-129
The Effect of Preparation Design on the Fracture Resistance of Zirconia Crown Copings (Computer Associated Design/Computer Associated Machine, CAD/CAM System)
One of the major problems of all ceramic restorations is their probable fracture against the occlusal force. The aim of the present in-vitro study is was to compare the effect of two marginal designs (chamfer & shoulder) on the fracture resistance of zirconia copings, CERCON (CAD/CAM). This in vitro study was done with single blind experimental technique. One stainless steel dye with 50′ chamfer finish line design (0.8 mm depth) was prepared using milling machine. Ten epoxy resin dyes were made, The same dye was retrieved and 50′ chamfer was converted into shoulder (1 mm).again ten epoxy resin dyes were made from shoulder dyes. Zirconia cores with 0.4 mm thickness and 35 μm cement Space fabricated on the 20 epoxy resin dyes (10 samples chamfer and 10 samples shoulder) in a dental laboratory. Then the zirconia cores were cemented on the epoxy resin dyes and underwent a fracture test with a universal testing machine (GOTECH AI-700LAC, Arson, USA) and samples were investigated from the point of view of the origin of the failure. The mean value of fracture resistance for shoulder margins were 788.90±99.56 N and for the chamfer margins were 991.75±112.00 N. The student’s T-test revealed a statistically significant difference between groups (P=0.001). The result of this study indicates that marginal design of the zirconia cores effects on their fracture resistance. A chamfer margin could improve the biomechanical performance of posterior single zirconia crown restorations. This may be because of strong unity and round internal angle in chamfer margin.
- 30 September 2011
- Vol. 8 (3) , 123-129
Open AccessThe Effect of Preparation Design on the Fracture Resistance of Zirconia Crown Copings (Computer Associated Design/Computer Associated Machine, CAD/CAM System)
One of the major problems of all ceramic restorations is their probable fracture against the occlusal force. The aim of the present in-vitro study is was to compare the effect of two marginal designs (chamfer & shoulder) on the fracture resistance of zirconia copings, CERCON (CAD/CAM). This in vitro study was done with single blind experimental technique. One stainless steel dye with 50′ chamfer finish line design (0.8 mm depth) was prepared using milling machine. Ten epoxy resin dyes were made, The same dye was retrieved and 50′ chamfer was converted into shoulder (1 mm).again ten epoxy resin dyes were made from shoulder dyes. Zirconia cores with 0.4 mm thickness and 35 μm cement Space fabricated on the 20 epoxy resin dyes (10 samples chamfer and 10 samples shoulder) in a dental laboratory. Then the zirconia cores were cemented on the epoxy resin dyes and underwent a fracture test with a universal testing machine (GOTECH AI-700LAC, Arson, USA) and samples were investigated from the point of view of the origin of the failure. The mean value of fracture resistance for shoulder margins were 788.90±99.56 N and for the chamfer margins were 991.75±112.00 N. The student’s T-test revealed a statistically significant difference between groups (P=0.001). The result of this study indicates that marginal design of the zirconia cores effects on their fracture resistance. A chamfer margin could improve the biomechanical performance of posterior single zirconia crown restorations. This may be because of strong unity and round internal angle in chamfer margin.