NSNorihiko Suzuki

Norihiko Suzuki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Norihiko Suzuki has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A technique for esophagojejunostomy following robot-assisted gastrectomy: a liner stapler and barbed suture device-based technique: a case series

    by Hironori Ohdaira, Teppei Kamada, Junji Takahashi, Keigo Nakashima, Yuichi Nakaseko, Takayuki Ishigaki, Norihiko Suzuki, Masashi Yoshida, Eigoro Yamanouchi, Yutaka Suzuki

    Background: Intracorporeal esophagojejunostomy after total or proximal robot-assisted gastrectomy is technically more demanding than gastroduodenostomy and gastrojejunostomy for distal gastrectomy, as well as laparoscopic surgery. We have established a safe and simple esophagojejunostomy procedure using a liner stapler attached to the Da Vinci Surgical System and a barbed suture device. Patients and methods: For esophagojejunostomy after total gastrectomy or proximal gastrectomy with double-tract reconstruction, we choose the “overlap method,” in which entry holes were made at the left of the esophageal stump and at 5 cm of the anal side in antimesentric area of the jejunum, followed by anastomosis on the left of the esophagus using SureForm (blue 45 mm) and hand-sewing closure of the common entry hole with V-Loc. We analyzed the short-term surgical outcomes of all patients. Results: 23 patients underwent this reconstruction technique. None of the patients required any further open surgeries. The mean time to perform anastomosis was 24.7±2.8 min. The postoperative course was uneventful in 22 patients; a single patient developed minor anastomotic leakage (Clavien–Dindo grade 3), which was treated with conservative therapy employing a drainage tube. Conclusion: Our esophagojejunostomy method following robot-assisted gastrectomy is simple and feasible, with acceptable short-term outcomes, and could represent the procedure of choice for esophagojejunostomy.


  • Open Access

    Acute respiratory distress syndrome due to sepsis caused by Bacteroides ovatus after acute appendicectomy

    by Yoshinobu Fuse, Hironori Ohdaira, Teppei Kamada, Junji Takahashi, Keigo Nakashima, Yuichi Nakaseko, Norihiko Suzuki, Masashi Yoshida, Shinya Okada, Yutaka Suzuki

    Background: Appendicectomy is generally a minimally invasive surgery, after which postoperative complications such as acute respiratory distress syndrome (ARDS) are rare. We describe a case of ARDS due to sepsis caused by Bacteroides ovatus after appendicectomy. Case presentation: A man in his 60 s presented to our hospital with a chief complaint of right lower quadrant abdominal pain. He was diagnosed with acute appendicitis and underwent emergency laparoscopic appendicectomy. Cefmetazole was administered as a perioperative antibacterial drug. Postoperatively, the abdominal findings improved. However, on postoperative day three, bloody sputum and respiratory distress were observed. We performed thoracoabdominal computed tomography (CT) and observed bilateral pleural effusion and mottled frosted glass shadows extending to both lung fields. ARDS was diagnosed. We treated the patient with steroids and sivelestat sodium and switched the antibacterial drug to meropenem. The patient’s general condition improved. After the patient was treated, Bacteroides ovatus was isolated from preoperative blood culture, which was resistant to cefmetazole. Conclusions: We encountered a case in which ARDS due to sepsis was caused by Bacteroides ovatus after acute appendicectomy. Blood culture to isolate the causative organism and determine its antimicrobial sensitivity after commencement of empiric antibiotics is important even in common diseases, such as acute appendicitis.


  • Open Access

    Nivolumab in combination with radiotherapy for metastatic esophageal neuroendocrine carcinoma after esophagectomy: a case report

    by Kuniyasu Takagi, Teppei Kamada, Yoshinobu Fuse, Wataru Kai, Junji Takahashi, Keigo Nakashima, Yuichi Nakaseko, Norihiko Suzuki, Masashi Yoshida, Shinya Okada, et al.

    Background: Metastatic neuroendocrine carcinoma has an extremely poor prognosis, and no effective second-line treatment is available. Herein, we describe a case of multiple metastases after primary resection of esophageal neuroendocrine carcinoma successfully treated with nivolumab plus radiotherapy in a short time. Case presentation: A man in his 70s presented to our hospital after an abnormality was detected on an upper gastrointestinal series. Upper gastrointestinal endoscopy revealed a type 2 tumor spanning the endothelial cell junction to the abdominal esophagus. Histopathological examination of the biopsy confirmed a diagnosis of esophageal neuroendocrine carcinoma. The patient had no distant metastases. Thoracoscopic esophagectomy with three-field lymph node dissection was performed. Histopathological examination confirmed a diagnosis of esophageal neuroendocrine carcinoma with features of adenoid cystic-like carcinoma and squamoid pattern (pT2 [MP], INF a, ly1, v1 [EVG], pIM0, pDM0, pRM0, pN1 [1/28], M0; Stage II), which was positive for synaptophysin. The postoperative course was good, with no complications. The patient was treated with 100 mg of irinotecan and 100 mg of cisplatin, administered every 4 weeks, as postoperative adjuvant chemotherapy. Grade 3 loss of appetite was observed, and adjuvant chemotherapy was discontinued after four cycles of first-line treatment. A positron emission tomography–computed tomography scan 3 years after surgery showed abnormal uptake in the subaortic, left hilar, and left axillary lymph nodes, and in a mass in the right lung apex. The patient was diagnosed with metastatic esophageal neuroendocrine carcinoma postoperatively. First-line treatment could not be repeated due to toxicity from the initial treatment. Nivolumab (240 mg every 2 weeks) was administered as second-line treatment, and radiotherapy was started (56 Gy delivered in 28 fractions to the local [subaortic and hilar] lymph nodes). After 10 cycles of nivolumab in combination with radiotherapy (56 Gy), a positron emission tomography–computed tomography scan showed disappearance of all lesions. A complete response was achieved. Maintenance therapy (240 mg of nivolumab) was continued. No recurrence has been observed for 42 months. Conclusions: We experienced a case in which nivolumab in combination with radiotherapy was effective for metastatic esophageal neuroendocrine carcinoma after primary resection.


  • Open Access

    Perineal stapled prolapse resection in combination with Thiersch operation for relapsed rectal prolapse: a case report

    by Teppei Kamada, Hironori Ohdaira, Junji Takahashi, Yoshinobu Fuse, Wataru Kai, Keigo Nakashima, Yuichi Nakaseko, Norihiko Suzuki, Masashi Yoshida, Takeo Usui, et al.

    Background Treatment options for complete rectal prolapse include over 100 procedures. In previous reports, operative rectal prolapse repair, regardless of the technique by perineal approach, was associated with high recurrence rates. However, there is no consensus on the optimal surgical procedure for relapsed rectal prolapse. Case presentation A 97-year-old woman was admitted to our hospital with a chief complaint of complete rectal prolapse measuring > 5 cm. The patient had a history of laparoscopic anterior suture rectopexy without sigmoid resection under general anesthesia for complete rectal prolapse one year prior. The patient's postoperative course was uneventful. However, her dementia worsened (Hasegawa's dementia scale: 5/30 points) after the first operation. Further, moderate-to-severe aortic valve stenosis was first diagnosed with heart failure 6 months after the operation. Nine months after the initial surgery, she experienced a recurrence of complete rectal prolapse measuring approximately 5 cm. Considering the coexistence of advanced age, severe dementia, and aortic valve stenosis, surgery under general anesthesia was not indicated. Perineal stapled prolapse resection in combination with the t operation was planned because of its minimal invasiveness and shortened hospital stay. The procedure was performed by a team of two surgeons in the jack knife position, under spinal anesthesia. The prolapse was cut along the long-axis direction with three linear staplers and resected along the short-axis direction with four linear staplers. The cross-section of the linear stapler was reinforced with 3-0 Vicryl sutures. After rectal resection, the Thiersch operation using 1-0 nylon thread 1 cm away from the anal verge was additionally performed. The operative time was 24 min, and intraoperative blood loss was 1 mL. The postoperative course was uneventful. Three months after the operation, no recurrence was observed, and defecation function was good with improvements of Wexner score. Conclusions Perineal stapled prolapse resection in combination with the Thiersch operation could be a useful option for patients with relapsed rectal prolapse and with poor general condition, who are not indicated for other surgical procedures.

  • Open Access

    Indocyanine green fluorescence-guided laparoscopic colorectal cancer surgery with prophylactic retrograde transileal conduit ureteral catheter placement after previous total cystectomy: a case report

    by Teppei Kamada, Yuichi Nakaseko, Masashi Yoshida, Wataru Kai, Junji Takahashi, Keigo Nakashima, Norihiko Suzuki, Hironori Ohdaira, Eigoro Yamanouchi, Yutaka Suzuki

    Background: Iatrogenic ureteral injury (UI) is a potentially serious complication of colorectal cancer surgery. Performing perioperative placement of ureteral stents or intraoperative fluorescence navigation surgery for the ureter using indocyanine green (ICG) has been employed as a method of preventing UI. However, transileal conduit stent placement has been considered challenging because it is difficult to identify the ureteral orifice due to the anatomical changes caused by a previous surgery. We report a case in which laparoscopic colectomy was safely performed using a combination of prophylactic transileal conduit ureteral catheter placement and intraoperative ICG fluorescence navigation surgery. Case presentation: A 75-year-old man presented to our hospital complaining of vomiting and abdominal distension. He had a history of open total cystectomy and ileal conduit urinary diversion 11 years prior to admission. Computed tomography confirmed colon dilation with fecal impaction from the ascending colon to the sigmoid colon and wall thickening in the sigmoid colon. Colonoscopy during the transanal ileus tube insertion revealed a Borrmann type II tumor with circumferential stenosis 10 cm distal to the junction between the descending colon and the sigmoid colon. The patient was diagnosed with colorectal ileus due to obstructive sigmoid colon cancer and underwent transanal ileus tube insertion. Severe intra-abdominal adhesions were expected due to the previous total cystectomy, and the left ureter was near the sigmoid colon tumor; therefore, prophylactic retrograde transileal conduit ureteral catheter placement was performed one day before the elective surgery. During the operation, 20 ml (5.0 × 10–2 mg/ml) ICG was administered from the transileal conduit ureteral catheter, and ICG fluorescence of the ureter was observed in the retroperitoneum. Laparoscopic Hartmann's operation was successfully performed, confirming ureter fluorescence. The operation time was 231 min, with 5 mL of intraoperative bleeding. The ureteral catheter was removed 3 days after the operation. The patient’s postoperative course was good with no complications, and he was discharged on postoperative day 7. Conclusions: Prophylactic transileal conduit ureteral catheter placement and ICG fluorescence navigation surgery were effective in performing laparoscopic colorectal surgery with severe adhesions after urinary diversion.


  • Open Access

    Pembrolizumab plus platinum-based chemotherapy for unfavorable cancer of unknown primary site: Case report

    by Teppei Kamada, Hiroshi Ishiguro, Shinya Okada, Hideyuki Takeuchi, Junji Takahashi, Keigo Nakashima, Yuichi Nakaseko, Norihiko Suzuki, Hironori Ohdaira, Yutaka Suzuki

    Introduction: We report a case of sustained complete response in unfavorable cancer of unknown primary site (CUP) successfully treated with chemotherapy combining pembrolizumab, pemetrexed and platinum. Case presentation: A 66-year-old man was presented with weight loss and cough for 3 months. Contrast-enhanced computed tomography (CT) confirmed a mass in the superior anterior mediastinum and multiple enlarged mediastinal and axillary lymph nodes. Positron emission tomography-CT (PET-CT) showed abnormal uptake in the corresponding lesions. Histopathological analysis of the left axillary nodule revealed poorly differentiated adenocarcinoma. Immunohistochemistry showed the tumor cells were positive for cytokeratin 7 and thyroid transcription factor-1 and negative for cytokeratin 20. Thus, the patient was diagnosed as poorly differentiated adenocarcinoma of unknown primary, and treated as non-small-cell lung cancer. Additional genetic testing revealed the patient was negative for EGFR, ALK fluorescence in situ hybridization, ROS1, BRAF, and PD-L1 22C3 IHC with Tumor Proportion Score (TPS) was less than 1%. The patient received six cycles of pembrolizumab, platinum, and pemetrexed intravenously. Cisplatin was switched to carboplatin because of cisplatin nephrotoxicity in one course. PET-CT after six cycles showed all lesions disappeared; complete response was considered to have been achieved. Maintenance therapy of pembrolizumab and pemetrexed has been continued for 6 months after the induction therapies to prevent progressive disease. Complete response has been maintained. Discussion: Chemotherapy with pembrolizumab, platinum and pemetrexed could be valuable for treating unfavorable CUP. Conclusion: Chemotherapy with pembrolizumab, platinum, and pemetrexed helped achieved sustained complete response in a patient with unfavorable CUP.


  • Open Access

    Magnetic compression anastomosis for non-anastomotic stenosis of the proximal jejunum after total gastrectomy with Roux-en-Y reconstruction: a case report

    by Teppei Kamada, Hironori Ohdaira, Hideyuki Takeuchi, Junji Takahashi, Rui Marukuchi, Norihiko Suzuki, Satoshi Narihiro, Sojun Hoshimoto, Masashi Yoshida, Eigoro Yamanouchi, et al.

    Background: Postoperative non-anastomotic stenosis of the proximal jejunum after total gastrectomy with Roux-en-Y reconstruction is a rare complication. If endoscopic balloon dilation proves ineffective, patients need re-operation under general anesthesia and experience a high rate of postoperative complications. Magnetic compression anastomosis is a nonsurgical procedure that can create an anastomosis similar to that obtained through surgery. We report a case in which magnetic compression anastomosis was successfully performed to avoid re-operation for non-anastomotic stenosis of the proximal jejunum after total gastrectomy with Roux-en-Y reconstruction. Case presentation: A 70-year-old woman was admitted to our hospital for treatment of non-anastomotic stenosis of the proximal jejunum. Open total gastrectomy and Roux-en-Y reconstruction were performed 2 years previously for advanced gastric cancer at another hospital. She complained of anorexia and obstructed passage of food. No recurrence of gastric cancer was identified. Esophagogastroduodenoscopy showed circumferential membranous stenosis of the jejunum 3 cm distal to the esophago-jejunal anastomosis. Endoscopic balloon dilation was performed three times, but proved ineffective. Magnetic compression anastomosis was planned because the stenosis existed near the esophago-jejunal anastomosis and re-operation was a highly invasive procedure requiring intrathoracic anastomosis. Endoscopic balloon dilation preceded placement of the parent magnet on the anal side of the stenosis. Confirming the improvement of stenosis, the parent magnet was placed on the anal side of the stenosis during esophagogastroduodenoscopy. The parent magnet attached to nylon thread was fixed to the cheek to prevent magnet migration. A week after placing the parent magnet, restenosis was confirmed and the daughter magnet was placed via nylon thread on the oral side of the stenosis. The two magnets were adsorbed in the end-to-end direction across the stenosis. Magnets adsorbed in the end-to-end direction moved to the anal side 11 days after placement. Wide anastomosis was confirmed by esophagogastroduodenoscopy. Endoscopic balloon dilation was regularly performed to prevent restenosis after magnetic compression anastomosis. No complications were observed postoperatively. The patient was able to eat normally and successfully reintegrated into society. Conclusions: Magnetic compression anastomosis could be a feasible procedure to avoid surgery for non-anastomotic stenosis of the proximal jejunum after gastrectomy with Roux-en-Y reconstruction.


  • Open Access

    Near-infrared fluorescent clip guided gastrectomy: Report of 2 cases (Case reports)

    by Satoshi Narihiro, Masashi Yoshida, Hironori Ohdaira, Hideyuki Takeuchi, Teppei Kamada, Rui Marukuchi, Norihiko Suzuki, Sojun Hoshimoto, Takayuki Sato, Yutaka Suzuki

    Introduction: This is the first report on near-infrared fluorescent (NIRF) clip-guided gastrectomy. The NIRF clip, ZEOCLIP FS, emits NIRF signals when excited. We hypothesized that preoperative placement of the ZEOCLIP FS near a gastric lesion would allow fluorescence laparoscopic localization of the clip, and hence, the lesion, during surgery. We report this technique in two cases. Case presentation: Case 1: An 81-year-old female was diagnosed with early gastric cancer and a pedunculated 4 cm large hyperplastic polyp that had prolapsed into the duodenum, and was scheduled for laparoscopy-assisted distal gastrectomy, due to the potential risk of dissection of the polyp with the duodenal wall. On the day before surgery, ZEOCLIP FS clips were endoscopically placed at the cancer site and the polyp. The locations of the fluorescent clips were confirmed intraoperatively using a full-color fluorescence laparoscope. Case 2: An 81-year-old male was scheduled for laparoscopy-assisted total gastrectomy for gastric cancer under fluorescent clip-guidance. Clip locations could not be confirmed during initial intraoperative observation. However, when the stomach wall was raised using forceps during a second observation attempt, the fluorescent clip locations were confirmed. Discussion: In case 1, it was easy to confirm clip location, facilitating complete resection of early gastric cancer without dissecting the polyp. In case 2, the fluorescent clip was located by raising the stomach and adjusting the angle between the stomach wall and the fluorescence laparoscope. Conclusion: The positive results of these two cases warrant conducting feasibility studies for use of this method.


  • Open Access

    Magnetic compression anastomosis with atypical anastomosis for anastomotic stenosis of the sigmoid colon: a case report

    by Teppei Kamada, Hironori Ohdaira, Sojun Hoshimoto, Satoshi Narihiro, Norihiko Suzuki, Rui Marukuchi, Hideyuki Takeuchi, Masashi Yoshida, Eigoro Yamanouchi, Yutaka Suzuki

    Background: Magnetic compression anastomosis (MCA) is mainly applied in the gastrointestinal and biliary tracts through a nonsurgical procedure that can create an anastomosis similar to that obtained through surgery. Magnets usually adsorb in the end-to-end direction (end-to-end anastomosis), exert a strong magnetic force and create an anastomosis according to the size of the magnets. Regular endoscopic dilation is required to prevent restenosis when the anastomotic size is small. We report a case in which MCA was successfully used to treat anastomotic stenosis of the sigmoid colon; the magnets adsorbed in the side-to-side direction rather than the end-to-end direction and generated a wide anastomosis in a short time that did not require endoscopic dilation. Case presentation: An 81-year-old woman was admitted to our hospital to treat anastomotic stenosis of the sigmoid colon for closure of transverse colostomy. Two years prior, the Hartmann operation and drainage were performed at other hospitals due to perforated diverticulitis of the sigmoid colon. Obstruction of the sigmoid colostomy occurred, and a transverse colostomy was performed. One year after the first surgery, high anterior resection was performed, but anastomotic stenosis occurred, causing obstruction. MCA was planned because the patient had a history of multiple operations and was expected to have strong adhesions postoperatively. MCA was safely performed, but two magnets were accidently adsorbed in the side-to-side direction. The magnet position could not be changed. The two magnets were expected to move and adsorb in an end-to-end direction naturally due to bowel movements. The magnets that adsorbed in the side-to-side direction dropped from the anus 5 days after treatment, and the anastomosis was observed by colonoscopy. Three ileus tubes were placed from the transverse colostomy beyond the anastomosis to prevent restenosis. Colonoscopy showed that the anastomosis diameter was wider than expected at 14 days after treatment, and endoscopic dilation was not necessary. No complications were observed in this patient’s postoperative course. Finally, closure of the patient’s colostomy was successfully performed. Conclusions: MCA with side-to-side anastomosis generated a wide anastomosis in a short time.


  • Open Access

    Introduction of VISIONSENSE® for indocyanine green fluorescence-guided parathyroidectomy

    by Teppei Kamada, Masashi Yoshida, Norihiko Suzuki, Hideyuki Takeuchi, Junji Takahashi, Rui Marukuchi, Satoshi Narihiro, Hironori Ohdaira, Yutaka Suzuki

    Introduction: VISIONSENSE® is a new near-infrared (NIR) fluorescence laparoscope and has an NIR overlay threshold function that allows us to set a floor for the NIR signal to be included in the overlay. We report the case of a patient who underwent indocyanine green (ICG) fluorescence-guided parathyroidectomy for primary hyperparathyroidism due to parathyroid adenoma using the threshold-adjustment function of VISIONSENSE®. Presentation of case: A 40-year-old man was referred to our department for examination and treatment of hypercalcemia. ICG fluorescence-guided parathyroidectomy using VISIONSENSE® was planned on diagnosis of primary hyperparathyroidism due to parathyroid tumor. In the operation, we were unable to readily recognize the parathyroid gland (PG). After intravenous injection of ICG, fluorescence from ICG appeared from the left thyroid lobe to the PG, but PG contours remained unclear. We therefore used the threshold-adjustment function of VISIONSENSE® to discard NIR signal values <50%. Clear contours of the PG were subsequently obtained, allowing recognition of the gland and successful ICG-guided parathyroidectomy. No postoperative complications were encountered and the pathological diagnosis was parathyroid adenoma. Discussion: In our case, both PG and thyroid showed ICG fluorescence, but the intensity of thyroid fluorescence was slightly little lower than that of PG fluorescence. To differentiate between fluorescence from PG and thyroid, the threshold-adjustment function of VISIONSENSE® may prove useful. Conclusion: This case suggests that the threshold-adjustment function of VISIONSENSE® may be useful to readily identify the PG in parathyroid surgery. Highlights: