Jean-François Léger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jean-François Léger has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Laurent Bourdieu
Institut de biologie de l’Ecole normale supérieure (IBENS), Ecole normale supérieure, CNRS, INSERM, Université PSL, Paris, France
13 shared publications - Sylvain Gigan
LKB - ENS - Sorbonne Université
4 shared publications D. Chatenay
Laboratoire de Physique Statistique, UMR CNRS 8550, Ecole Normale Supérieure, Département de Physique, 24 rue Lhomond, 75005 Paris, France
3 shared publicationsDidier Chatenay
3 shared publications- Stéphane Dieudonné
Institut de Biologie de l'Ecole Normale Superieure (IBENS), Ecole Normale Superieure, CNRS, INSERM, PSL Research University, Paris 75005, France
3 shared publications - Yves Kremer
Department of Basic Neurosciences, Medical Faculty, University of Geneva, 1211 Geneva, Switzerland
3 shared publications
Latest Publications
- Open Access
- 21 November 2016
- Published by Springer Nature in Nature Communications
- Vol. 7 (1) , 13528
A radial map of multi-whisker correlation selectivity in the rat barrel cortex
In the barrel cortex, several features of single-whisker stimuli are organized in functional maps. The barrel cortex also encodes spatio-temporal correlation patterns of multi-whisker inputs, but so far the cortical mapping of neurons tuned to such input statistics is unknown. Here we report that layer 2/3 of the rat barrel cortex contains an additional functional map based on neuronal tuning to correlated versus uncorrelated multi-whisker stimuli: neuron responses to uncorrelated multi-whisker stimulation are strongest above barrel centres, whereas neuron responses to correlated and anti-correlated multi-whisker stimulation peak above the barrel–septal borders, forming rings of multi-whisker synchrony-preferring cells.
- 21 November 2016
- Published by Springer Nature in Nature Communications
- Vol. 7 (1) , 13528
Open AccessA radial map of multi-whisker correlation selectivity in the rat barrel cortex
In the barrel cortex, several features of single-whisker stimuli are organized in functional maps. The barrel cortex also encodes spatio-temporal correlation patterns of multi-whisker inputs, but so far the cortical mapping of neurons tuned to such input statistics is unknown. Here we report that layer 2/3 of the rat barrel cortex contains an additional functional map based on neuronal tuning to correlated versus uncorrelated multi-whisker stimuli: neuron responses to uncorrelated multi-whisker stimulation are strongest above barrel centres, whereas neuron responses to correlated and anti-correlated multi-whisker stimulation peak above the barrel–septal borders, forming rings of multi-whisker synchrony-preferring cells.
- Open Access
- 19 October 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (22) , 28191-28205
Fast spatial beam shaping by acousto-optic diffraction for 3D non-linear microscopy
Acousto-optic deflection (AOD) devices offer unprecedented fast control of the entire spatial structure of light beams, most notably their phase. AOD light modulation of ultra-short laser pulses, however, is not straightforward to implement because of intrinsic chromatic dispersion and non-stationarity of acousto-optic diffraction. While schemes exist to compensate chromatic dispersion, non-stationarity remains an obstacle. In this work we demonstrate an efficient AOD light modulator for stable phase modulation using time-locked generation of frequency-modulated acoustic waves at the full repetition rate of a high power laser pulse amplifier of 80 kHz. We establish the non-local relationship between the optical phase and the generating acoustic frequency function and verify the system for temporal stability, phase accuracy and generation of non-linear two-dimensional phase functions.
- 19 October 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (22) , 28191-28205
Open AccessFast spatial beam shaping by acousto-optic diffraction for 3D non-linear microscopy
Acousto-optic deflection (AOD) devices offer unprecedented fast control of the entire spatial structure of light beams, most notably their phase. AOD light modulation of ultra-short laser pulses, however, is not straightforward to implement because of intrinsic chromatic dispersion and non-stationarity of acousto-optic diffraction. While schemes exist to compensate chromatic dispersion, non-stationarity remains an obstacle. In this work we demonstrate an efficient AOD light modulator for stable phase modulation using time-locked generation of frequency-modulated acoustic waves at the full repetition rate of a high power laser pulse amplifier of 80 kHz. We establish the non-local relationship between the optical phase and the generating acoustic frequency function and verify the system for temporal stability, phase accuracy and generation of non-linear two-dimensional phase functions.
- Top Cited PapersOpen Access
- 14 May 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (10) , 13505-13516
Characterization of the angular memory effect of scattered light in biological tissues
High resolution optical microscopy is essential in neuroscience but suffers from scattering in biological tissues and therefore grants access to superficial brain layers only. Recently developed techniques use scattered photons for imaging by exploiting angular correlations in transmitted light and could potentially increase imaging depths. But those correlations (‘angular memory effect’) are of a very short range and should theoretically be only present behind and not inside scattering media. From measurements on neural tissues and complementary simulations, we find that strong forward scattering in biological tissues can enhance the memory effect range and thus the possible field-of-view by more than an order of magnitude compared to isotropic scattering for ∼1 mm thick tissue layers.
- 14 May 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (10) , 13505-13516
Top Cited PapersOpen AccessCharacterization of the angular memory effect of scattered light in biological tissues
High resolution optical microscopy is essential in neuroscience but suffers from scattering in biological tissues and therefore grants access to superficial brain layers only. Recently developed techniques use scattered photons for imaging by exploiting angular correlations in transmitted light and could potentially increase imaging depths. But those correlations (‘angular memory effect’) are of a very short range and should theoretically be only present behind and not inside scattering media. From measurements on neural tissues and complementary simulations, we find that strong forward scattering in biological tissues can enhance the memory effect range and thus the possible field-of-view by more than an order of magnitude compared to isotropic scattering for ∼1 mm thick tissue layers.
- Open Access
- 13 September 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (10) , 2510-2525
Measuring aberrations in the rat brain by coherence-gated wavefront sensing using a Linnik interferometer
Aberrations limit the resolution, signal intensity and achievable imaging depth in microscopy. Coherence-gated wavefront sensing (CGWS) allows the fast measurement of aberrations in scattering samples and therefore the implementation of adaptive corrections. However, CGWS has been demonstrated so far only in weakly scattering samples. We designed a new CGWS scheme based on a Linnik interferometer and a SLED light source, which is able to compensate dispersion automatically and can be implemented on any microscope. In the highly scattering rat brain tissue, where multiply scattered photons falling within the temporal gate of the CGWS can no longer be neglected, we have measured known defocus and spherical aberrations up to a depth of 400 µm.
- 13 September 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (10) , 2510-2525
Open AccessMeasuring aberrations in the rat brain by coherence-gated wavefront sensing using a Linnik interferometer
Aberrations limit the resolution, signal intensity and achievable imaging depth in microscopy. Coherence-gated wavefront sensing (CGWS) allows the fast measurement of aberrations in scattering samples and therefore the implementation of adaptive corrections. However, CGWS has been demonstrated so far only in weakly scattering samples. We designed a new CGWS scheme based on a Linnik interferometer and a SLED light source, which is able to compensate dispersion automatically and can be implemented on any microscope. In the highly scattering rat brain tissue, where multiply scattered photons falling within the temporal gate of the CGWS can no longer be neglected, we have measured known defocus and spherical aberrations up to a depth of 400 µm.
- 20 July 2012
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 134 (36) , 14923-14931
Calcium Rubies: A Family of Red-Emitting Functionalizable Indicators Suitable for Two-Photon Ca2+ Imaging
We designed Calcium Rubies, a family of functionalizable BAPTA-based red-fluorescent calcium (Ca2+) indicators as new tools for biological Ca2+ imaging. The specificity of this Ca2+-indicator family is its side arm, attached on the ethylene glycol bridge that allows coupling the indicator to various groups while leaving open the possibility of aromatic substitutions on the BAPTA core for tuning the Ca2+-binding affinity. Using this possibility we now synthesize and characterize three different CaRubies with affinities between 3 and 22 μM. Their long excitation and emission wavelengths (peaks at 586/604 nm) allow their use in otherwise challenging multicolor experiments, e.g., when combining Ca2+ uncaging or optogenetic stimulation with Ca2+ imaging in cells expressing fluorescent proteins. We illustrate this capacity by the detection of Ca2+ transients evoked by blue light in cultured astrocytes expressing CatCh, a light-sensitive Ca2+-translocating channelrhodopsin linked to yellow fluorescent protein. Using time-correlated single-photon counting, we measured fluorescence lifetimes for all CaRubies and demonstrate a 10-fold increase in the average lifetime upon Ca2+ chelation. Since only the fluorescence quantum yield but not the absorbance of the CaRubies is Ca2+-dependent, calibrated two-photon fluorescence excitation measurements of absolute Ca2+ concentrations are feasible.
- 20 July 2012
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 134 (36) , 14923-14931
Calcium Rubies: A Family of Red-Emitting Functionalizable Indicators Suitable for Two-Photon Ca2+ Imaging
We designed Calcium Rubies, a family of functionalizable BAPTA-based red-fluorescent calcium (Ca2+) indicators as new tools for biological Ca2+ imaging. The specificity of this Ca2+-indicator family is its side arm, attached on the ethylene glycol bridge that allows coupling the indicator to various groups while leaving open the possibility of aromatic substitutions on the BAPTA core for tuning the Ca2+-binding affinity. Using this possibility we now synthesize and characterize three different CaRubies with affinities between 3 and 22 μM. Their long excitation and emission wavelengths (peaks at 586/604 nm) allow their use in otherwise challenging multicolor experiments, e.g., when combining Ca2+ uncaging or optogenetic stimulation with Ca2+ imaging in cells expressing fluorescent proteins. We illustrate this capacity by the detection of Ca2+ transients evoked by blue light in cultured astrocytes expressing CatCh, a light-sensitive Ca2+-translocating channelrhodopsin linked to yellow fluorescent protein. Using time-correlated single-photon counting, we measured fluorescence lifetimes for all CaRubies and demonstrate a 10-fold increase in the average lifetime upon Ca2+ chelation. Since only the fluorescence quantum yield but not the absorbance of the CaRubies is Ca2+-dependent, calibrated two-photon fluorescence excitation measurements of absolute Ca2+ concentrations are feasible.
- Open Access
- 1 November 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (11) , 116012-1160129
Single myelin fiber imaging in living rodents without labeling by deep optical coherence microscopy
Myelin sheath disruption is responsible for multiple neuropathies in the central and peripheral nervous system. Myelin imaging has thus become an important diagnosis tool. However, in vivo imaging has been limited to either low-resolution techniques unable to resolve individual fibers or to low-penetration imaging of single fibers, which cannot provide quantitative information about large volumes of tissue, as required for diagnostic purposes. Here, we perform myelin imaging without labeling and at micron-scale resolution with >300-μm penetration depth on living rodents. This was achieved with a prototype [termed deep optical coherence microscopy (deep-OCM)] of a high-numerical aperture infrared full-field optical coherence microscope, which includes aberration correction for the compensation of refractive index mismatch and high-frame-rate interferometric measurements. We were able to measure the density of individual myelinated fibers in the rat cortex over a large volume of gray matter. In the peripheral nervous system, deep-OCM allows, after minor surgery, in situ imaging of single myelinated fibers over a large fraction of the sciatic nerve. This allows quantitative comparison of normal and Krox20 mutant mice, in which myelination in the peripheral nervous system is impaired. This opens promising perspectives for myelin chronic imaging in demyelinating diseases and for minimally invasive medical diagnosis.
- 1 November 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (11) , 116012-1160129
Open AccessSingle myelin fiber imaging in living rodents without labeling by deep optical coherence microscopy
Myelin sheath disruption is responsible for multiple neuropathies in the central and peripheral nervous system. Myelin imaging has thus become an important diagnosis tool. However, in vivo imaging has been limited to either low-resolution techniques unable to resolve individual fibers or to low-penetration imaging of single fibers, which cannot provide quantitative information about large volumes of tissue, as required for diagnostic purposes. Here, we perform myelin imaging without labeling and at micron-scale resolution with >300-μm penetration depth on living rodents. This was achieved with a prototype [termed deep optical coherence microscopy (deep-OCM)] of a high-numerical aperture infrared full-field optical coherence microscope, which includes aberration correction for the compensation of refractive index mismatch and high-frame-rate interferometric measurements. We were able to measure the density of individual myelinated fibers in the rat cortex over a large volume of gray matter. In the peripheral nervous system, deep-OCM allows, after minor surgery, in situ imaging of single myelinated fibers over a large fraction of the sciatic nerve. This allows quantitative comparison of normal and Krox20 mutant mice, in which myelination in the peripheral nervous system is impaired. This opens promising perspectives for myelin chronic imaging in demyelinating diseases and for minimally invasive medical diagnosis.
- Open Access
- 20 July 2011
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 31 (29) , 10689-10700
Late Emergence of the Vibrissa Direction Selectivity Map in the Rat Barrel Cortex
In the neocortex, neuronal selectivities for multiple sensorimotor modalities are often distributed in topographical maps thought to emerge during a restricted period in early postnatal development. Rodent barrel cortex contains a somatotopic map for vibrissa identity, but the existence of maps representing other tactile features has not been clearly demonstrated. We addressed the issue of the existence in the rat cortex of an intrabarrel map for vibrissa movement direction using in vivo two-photon imaging. We discovered that the emergence of a direction map in rat barrel cortex occurs long after all known critical periods in the somatosensory system. This map is remarkably specific, taking a pinwheel-like form centered near the barrel center and aligned to the barrel cortex somatotopy. We suggest that this map may arise from intracortical mechanisms and demonstrate by simulation that the combination of spike-timing-dependent plasticity at synapses between layer 4 and layer 2/3 and realistic pad stimulation is sufficient to produce such a map. Its late emergence long after other classical maps suggests that experience-dependent map formation and refinement continue throughout adult life.
- 20 July 2011
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 31 (29) , 10689-10700
Open AccessLate Emergence of the Vibrissa Direction Selectivity Map in the Rat Barrel Cortex
In the neocortex, neuronal selectivities for multiple sensorimotor modalities are often distributed in topographical maps thought to emerge during a restricted period in early postnatal development. Rodent barrel cortex contains a somatotopic map for vibrissa identity, but the existence of maps representing other tactile features has not been clearly demonstrated. We addressed the issue of the existence in the rat cortex of an intrabarrel map for vibrissa movement direction using in vivo two-photon imaging. We discovered that the emergence of a direction map in rat barrel cortex occurs long after all known critical periods in the somatosensory system. This map is remarkably specific, taking a pinwheel-like form centered near the barrel center and aligned to the barrel cortex somatotopy. We suggest that this map may arise from intracortical mechanisms and demonstrate by simulation that the combination of spike-timing-dependent plasticity at synapses between layer 4 and layer 2/3 and realistic pad stimulation is sufficient to produce such a map. Its late emergence long after other classical maps suggests that experience-dependent map formation and refinement continue throughout adult life.
- 28 February 2011
- Published by Optica Publishing Group in Optics Express
- Vol. 19 (6) , 4833-4847
Brain refractive index measured in vivo with high-NA defocus-corrected full-field OCT and consequences for two-photon microscopy
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 28 February 2011
- Published by Optica Publishing Group in Optics Express
- Vol. 19 (6) , 4833-4847
Brain refractive index measured in vivo with high-NA defocus-corrected full-field OCT and consequences for two-photon microscopy
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 23 June 2008
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (14) , 10066-10076
A spatio-temporally compensated acousto-optic scanner for two-photon microscopy providing large field of view
Acousto-optic deflectors (AOD) are promising ultrafast scanners for non-linear microscopy. Their use has been limited until now by their small scanning range and by the spatial and temporal dispersions of the laser beam going through the deflectors. We show that the use of AOD of large aperture (13mm) compared to standard deflectors allows accessing much larger field of view while minimizing spatio-temporal distortions. An acousto-optic modulator (AOM) placed at distance of the AOD is used to compensate spatial and temporal dispersions. Fine tuning of the AOM-AOD setup using a frequency-resolved optical gating (GRENOUILLE) allows elimination of pulse front tilt whereas spatial chirp is minimized thanks to the large aperture AOD.
- 23 June 2008
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (14) , 10066-10076
A spatio-temporally compensated acousto-optic scanner for two-photon microscopy providing large field of view
Acousto-optic deflectors (AOD) are promising ultrafast scanners for non-linear microscopy. Their use has been limited until now by their small scanning range and by the spatial and temporal dispersions of the laser beam going through the deflectors. We show that the use of AOD of large aperture (13mm) compared to standard deflectors allows accessing much larger field of view while minimizing spatio-temporal distortions. An acousto-optic modulator (AOM) placed at distance of the AOD is used to compensate spatial and temporal dispersions. Fine tuning of the AOM-AOD setup using a frequency-resolved optical gating (GRENOUILLE) allows elimination of pulse front tilt whereas spatial chirp is minimized thanks to the large aperture AOD.
- 1 June 2006
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 154 (1-2) , 161-174
Ultrafast random-access scanning in two-photon microscopy using acousto-optic deflectors
- 1 June 2006
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 154 (1-2) , 161-174
Ultrafast random-access scanning in two-photon microscopy using acousto-optic deflectors