Ming Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ming Li has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Song Liu
Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China
3 shared publications - Chen Chu
Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
2 shared publications - Jian He
Department of Nuclear Medicine, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210008, Jiangsu Province, China.
2 shared publications - Nan Zhou
Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
2 shared publications - Weibo Chen
Philips healthcare Company, Shanghai, China
2 shared publications - Xin Dou
Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
2 shared publications
Latest Publications
- Open Access
- 27 November 2025
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 19, 1725953
Cardiac structure and inflammation drive memory impairment via dual pathways of heart-brain axis dysregulation in atrial fibrillation patients undergoing catheter ablation
Background: Atrial fibrillation (AF) patients undergoing catheter ablation (CA) frequently present with cardiac structural and functional alterations and persistent memory impairment. This study aimed to investigate how cardiac structure and function impacts memory-related brain structure and function, whether CA reverses impaired memory networks, and to delineate the dual-pathway regulatory mechanism of the heart-brain axis underlying AF-associated memory deficits. Methods: Thirty-eight AF patients underwent longitudinal assessments [memory function tests, clinical evaluations including blood biomarkers and cardiac function, structural/functional magnetic resonance imaging (MRI)] before CA and on postoperative day 7. Forty-five healthy controls (CN) were included for comparison. Hippocampal functional connectivity (FC) and voxel-based morphometry were used to quantify memory-related brain networks and gray matter (GM) volume. Bivariate correlations explored relationships between GM alterations, hippocampal FC, memory performance, and clinical features (cardiac structural parameters and blood-borne inflammatory markers). Results: First, compared with CN, AF patients showed memory impairment, reduced GM volume in the bilateral calcarine cortex, cuneus, lingual gyrus, inferior/middle temporal gyri, and left fusiform gyrus, and increased hippocampal FC with the bilateral middle frontal gyrus, insula, Rolandic operculum, left inferior frontal gyrus (opercular/orbital/triangular parts), and right postcentral/supramarginal/superior temporal gyri. Second, left ventricular end-diastolic diameter (LVDd) was positively associated with GM volume in the left middle temporal gyrus (MTG.L, p = 0.016), right inferior temporal gyrus ( p = 0.006), and left cuneus ( p = 0.026); MTG.L GM volume correlated positively with Auditory Verbal Learning Test (AVLT)-Recall scores ( p = 0.044), while hippocampal FC with the right postcentral gyrus correlated negatively with both inflammatory markers (PCT, p = 0.010) and AVLT-Delayed Recall (20 min) scores ( p = 0.013). Third, post catheter ablation (post-CA), AF patients exhibited increased hippocampal FC with the right middle frontal gyrus, right midcingulate cortex, and left superior frontal gyrus, and decreased FC with the right lingual gyrus and calcarine cortex. Conclusion: Cardiac structural parameters (LVDd) associate with memory-related brain atrophy, whereas blood-borne inflammatory markers link to hippocampal memory network dysregulation—two distinct pathways driving AF-related memory impairment. These findings clarify the dual-pathway regulatory mechanism of the heart-brain axis, offering novel insights into AF-associated cognitive dysfunction and potential CA-mediated memory recovery.
- 27 November 2025
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 19, 1725953
Open AccessCardiac structure and inflammation drive memory impairment via dual pathways of heart-brain axis dysregulation in atrial fibrillation patients undergoing catheter ablation
Background: Atrial fibrillation (AF) patients undergoing catheter ablation (CA) frequently present with cardiac structural and functional alterations and persistent memory impairment. This study aimed to investigate how cardiac structure and function impacts memory-related brain structure and function, whether CA reverses impaired memory networks, and to delineate the dual-pathway regulatory mechanism of the heart-brain axis underlying AF-associated memory deficits. Methods: Thirty-eight AF patients underwent longitudinal assessments [memory function tests, clinical evaluations including blood biomarkers and cardiac function, structural/functional magnetic resonance imaging (MRI)] before CA and on postoperative day 7. Forty-five healthy controls (CN) were included for comparison. Hippocampal functional connectivity (FC) and voxel-based morphometry were used to quantify memory-related brain networks and gray matter (GM) volume. Bivariate correlations explored relationships between GM alterations, hippocampal FC, memory performance, and clinical features (cardiac structural parameters and blood-borne inflammatory markers). Results: First, compared with CN, AF patients showed memory impairment, reduced GM volume in the bilateral calcarine cortex, cuneus, lingual gyrus, inferior/middle temporal gyri, and left fusiform gyrus, and increased hippocampal FC with the bilateral middle frontal gyrus, insula, Rolandic operculum, left inferior frontal gyrus (opercular/orbital/triangular parts), and right postcentral/supramarginal/superior temporal gyri. Second, left ventricular end-diastolic diameter (LVDd) was positively associated with GM volume in the left middle temporal gyrus (MTG.L, p = 0.016), right inferior temporal gyrus ( p = 0.006), and left cuneus ( p = 0.026); MTG.L GM volume correlated positively with Auditory Verbal Learning Test (AVLT)-Recall scores ( p = 0.044), while hippocampal FC with the right postcentral gyrus correlated negatively with both inflammatory markers (PCT, p = 0.010) and AVLT-Delayed Recall (20 min) scores ( p = 0.013). Third, post catheter ablation (post-CA), AF patients exhibited increased hippocampal FC with the right middle frontal gyrus, right midcingulate cortex, and left superior frontal gyrus, and decreased FC with the right lingual gyrus and calcarine cortex. Conclusion: Cardiac structural parameters (LVDd) associate with memory-related brain atrophy, whereas blood-borne inflammatory markers link to hippocampal memory network dysregulation—two distinct pathways driving AF-related memory impairment. These findings clarify the dual-pathway regulatory mechanism of the heart-brain axis, offering novel insights into AF-associated cognitive dysfunction and potential CA-mediated memory recovery.
- Open Access
- 21 January 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (6) , 2505-2515
Improving Image Quality and Decreasing SAR With High Dielectric Constant Pads in 3 T Fetal MRI
Background: At high magnetic fields, degraded image quality due to dielectric artifacts and elevated specific absorption rate (SAR) are two technical challenges in fetal MRI.Purpose: To assess the potential of high dielectric constant (HDC) pad in increasing image quality and decreasing SAR for 3 T fetal MRI.Study Type: Prospective.Field Strength/Sequence: 3 T. Balanced steady‐state free precession (bSSFP) and single‐shot fast spin‐echo (SSFSE).Population: One hundred twenty‐eight participants (maternal‐age 29.0 ± 3.6, range 20–40; gestational‐age 30.3 ± 3.5 weeks, range 22–37 weeks) undertook bSSFP and 40 participants (maternal‐age 29.5 ± 3.8, range 19–40; gestational‐age 30.4 ± 3.5 weeks, range 23–37 weeks) undertook SSFSE.Assessment: Patient clinical characteristics were recorded, such as gestational‐age, amniotic‐fluid‐index, abdominal‐circumference, body‐mass‐index, and fetal‐presentation. Quantitative Image‐quality analysis included signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR). Qualitative analysis was performed by three radiologists with four‐point scale to evaluate overall image quality, dielectric artifact, and diagnostic confidence. Whole‐body total SAR was obtained from the vendor workstation.Statistical Testing: Paired rank sum test was used to analyze the differences in SNR, CNR, overall image quality, dielectric artifact, diagnostic confidence, and SAR with and without HDC pad. Spearman correlation test was used to detect correlations between image quality variable changes and patient clinical characteristics. P values P‐values ranging from 0.072 to 0.992).Data Conclusion: In the clinical setting, adding a HDC pad might increase image quality while reducing dielectric artifact and SAR.Plan Language Summary: Dielectric artifacts and elevated SAR are two technical problems in 3T fetal MRI. In a prospective analysis of 168 pregnant participants undertaking 3.0T fetal MRI scanning, high dielectric constant (HDC) pad increased SNR by 41.45%, CNR by 54.05% on bSSFP, and SNR by 258.76%, CNR by 459.55% on SSFSE. Overall image quality, dielectric artifact reduction, and diagnostic confidence assessed by three radiologists was improved. Whole‐body total SAR decreased by 32.60% on bSSFP and by 15.40% on SSFSE. These findings suggested that the HDC pad can enhance fetal MRI safety and quality, making it a promising tool for clinical practice.Evidence Level: 2Technical Efficacy: Stage 5
- 21 January 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (6) , 2505-2515
Open AccessImproving Image Quality and Decreasing SAR With High Dielectric Constant Pads in 3 T Fetal MRI
Background: At high magnetic fields, degraded image quality due to dielectric artifacts and elevated specific absorption rate (SAR) are two technical challenges in fetal MRI.Purpose: To assess the potential of high dielectric constant (HDC) pad in increasing image quality and decreasing SAR for 3 T fetal MRI.Study Type: Prospective.Field Strength/Sequence: 3 T. Balanced steady‐state free precession (bSSFP) and single‐shot fast spin‐echo (SSFSE).Population: One hundred twenty‐eight participants (maternal‐age 29.0 ± 3.6, range 20–40; gestational‐age 30.3 ± 3.5 weeks, range 22–37 weeks) undertook bSSFP and 40 participants (maternal‐age 29.5 ± 3.8, range 19–40; gestational‐age 30.4 ± 3.5 weeks, range 23–37 weeks) undertook SSFSE.Assessment: Patient clinical characteristics were recorded, such as gestational‐age, amniotic‐fluid‐index, abdominal‐circumference, body‐mass‐index, and fetal‐presentation. Quantitative Image‐quality analysis included signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR). Qualitative analysis was performed by three radiologists with four‐point scale to evaluate overall image quality, dielectric artifact, and diagnostic confidence. Whole‐body total SAR was obtained from the vendor workstation.Statistical Testing: Paired rank sum test was used to analyze the differences in SNR, CNR, overall image quality, dielectric artifact, diagnostic confidence, and SAR with and without HDC pad. Spearman correlation test was used to detect correlations between image quality variable changes and patient clinical characteristics. P values P‐values ranging from 0.072 to 0.992).Data Conclusion: In the clinical setting, adding a HDC pad might increase image quality while reducing dielectric artifact and SAR.Plan Language Summary: Dielectric artifacts and elevated SAR are two technical problems in 3T fetal MRI. In a prospective analysis of 168 pregnant participants undertaking 3.0T fetal MRI scanning, high dielectric constant (HDC) pad increased SNR by 41.45%, CNR by 54.05% on bSSFP, and SNR by 258.76%, CNR by 459.55% on SSFSE. Overall image quality, dielectric artifact reduction, and diagnostic confidence assessed by three radiologists was improved. Whole‐body total SAR decreased by 32.60% on bSSFP and by 15.40% on SSFSE. These findings suggested that the HDC pad can enhance fetal MRI safety and quality, making it a promising tool for clinical practice.Evidence Level: 2Technical Efficacy: Stage 5
- 18 December 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (7) , 2817-2827
Dual-energy CT for predicting serosal invasion in gastric cancer and subtype analysis
Purpose To predict the serosal invasion of gastric cancer (GC) using dual-energy CT (DECT)-based parameters and analyze the diagnostic performance according to different subtypes. Methods The patients were divided into the T1-3 group and T4a group. The irregular region of interest (ROI) was manually delineated on the largest cross-section of the lesion. The ROI area, iodine concentration (IC), normalized iodine concentration (nIC), fat fraction, CT value mean, and standard deviation were measured in the late arterial (LAP) and venous phase (VP). The Mann-Whitney U test was used to assess differences between different T-stage groups and histopathological subtypes of GC. A model was established based on DECT parameters, and the receiver operating characteristic (ROC) curve was used to evaluate the diagnostic performance. Results Preliminary analysis showed that there were significant differences in ROI area, IC, nIC and CT value mean in VP and ROI area in LAP between T1-3 and T4a GC (all p < 0.05). The AUC of the comprehensive model composed of ROI and nIC in VP was 0.805. For different subtypes, multiple DECT parameters of poorly cohesive carcinoma (PCC) showed significant differences. Conclusion ROI area in LAP and VP, IC, nIC, and CT value mean in VP have significant differences in distinguishing between T1-3 and T4a GC. Iodine-related parameters in VP differed significantly between T1-3 and T4a in PCCs, rather than TACs. Considering the heterogeneity of different WHO subtypes, DECT iodine-related parameters in VP are more predictive of the serosal invasion status of GC compared to LAP. Graphical Abstract
- 18 December 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (7) , 2817-2827
Dual-energy CT for predicting serosal invasion in gastric cancer and subtype analysis
Purpose To predict the serosal invasion of gastric cancer (GC) using dual-energy CT (DECT)-based parameters and analyze the diagnostic performance according to different subtypes. Methods The patients were divided into the T1-3 group and T4a group. The irregular region of interest (ROI) was manually delineated on the largest cross-section of the lesion. The ROI area, iodine concentration (IC), normalized iodine concentration (nIC), fat fraction, CT value mean, and standard deviation were measured in the late arterial (LAP) and venous phase (VP). The Mann-Whitney U test was used to assess differences between different T-stage groups and histopathological subtypes of GC. A model was established based on DECT parameters, and the receiver operating characteristic (ROC) curve was used to evaluate the diagnostic performance. Results Preliminary analysis showed that there were significant differences in ROI area, IC, nIC and CT value mean in VP and ROI area in LAP between T1-3 and T4a GC (all p < 0.05). The AUC of the comprehensive model composed of ROI and nIC in VP was 0.805. For different subtypes, multiple DECT parameters of poorly cohesive carcinoma (PCC) showed significant differences. Conclusion ROI area in LAP and VP, IC, nIC, and CT value mean in VP have significant differences in distinguishing between T1-3 and T4a GC. Iodine-related parameters in VP differed significantly between T1-3 and T4a in PCCs, rather than TACs. Considering the heterogeneity of different WHO subtypes, DECT iodine-related parameters in VP are more predictive of the serosal invasion status of GC compared to LAP. Graphical Abstract
- Open Access
- 1 January 2020
- Published by Elsevier in NeuroImage: Clinical
- Vol. 26, 102224
Altered gray matter volumes in post-stroke depressive patients after subcortical stroke
- 1 January 2020
- Published by Elsevier in NeuroImage: Clinical
- Vol. 26, 102224
Open AccessAltered gray matter volumes in post-stroke depressive patients after subcortical stroke
- 26 November 2016
- Published by Elsevier in European Journal of Radiology
- Vol. 86, 241-247
Correlation between intravoxel incoherent motion MR parameters and MR nodular grade of parotid glands in patients with Sjögren’s syndrome: A pilot study
- 26 November 2016
- Published by Elsevier in European Journal of Radiology
- Vol. 86, 241-247
Correlation between intravoxel incoherent motion MR parameters and MR nodular grade of parotid glands in patients with Sjögren’s syndrome: A pilot study
- Open Access
- 8 November 2016
- Published by Springer Nature in BMC Cancer
- Vol. 16 (1) , 1-10
Early evaluation of irradiated parotid glands with intravoxel incoherent motion MR imaging: correlation with dynamic contrast-enhanced MR imaging
Radiation-induced parotid damage is one of the most common complications in patients with nasopharyngeal carcinoma (NPC) undergoing radiotherapy (RT). Intravoxel incoherent motion (IVIM) magnetic resonance (MR) imaging has been reported for evaluating irradiated parotid damage. However, the changes of IVIM perfusion-related parameters in irradiated parotid glands have not been confirmed by conventional perfusion measurements obtained from dynamic contrast-enhanced (DCE) MR imaging. The purposes of this study were to monitor radiation-induced parotid damage using IVIM and DCE MR imaging and to investigate the correlations between changes of these MR parameters. Eighteen NPC patients underwent bilateral parotid T1-weighted, IVIM and DCE MR imaging pre-RT (2 weeks before RT) and post-RT (4 weeks after RT). Parotid volume; IVIM MR parameters, including apparent diffusion coefficient (ADC), pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f); and DCE MR parameters, including maximum relative enhancement (MRE), time to peak (TTP), Wash in Rate, and the degree of xerostomia were recorded. Correlations of parotid MR parameters with mean radiation dose, atrophy rate and xerostomia degree, as well as the relationships between IVIM and DCE MR parameters, were investigated. From pre-RT to post-RT, all of the IVIM and DCE MR parameters increased significantly (p < 0.001 for ADC, D, f, MRE, Wash in Rate; p = 0.024 for D*; p = 0.037 for TTP). Change rates of ADC, f and MRE were negatively correlated with atrophy rate significantly (all p < 0.05). Significant correlations were observed between the change rates of D* and MRE (r = 0.371, p = 0.026) and between the change rates of D* and TTP (r = 0.396, p = 0.017). The intra- and interobserver reproducibility of IVIM and DCE MR parameters was good to excellent (intraclass correlation coefficient, 0.633–0.983). Early radiation-induced changes of parotid glands could be evaluated by IVIM and DCE MR imaging. Certain IVIM and DCE MR parameters were correlated significantly.
- 8 November 2016
- Published by Springer Nature in BMC Cancer
- Vol. 16 (1) , 1-10
Open AccessEarly evaluation of irradiated parotid glands with intravoxel incoherent motion MR imaging: correlation with dynamic contrast-enhanced MR imaging
Radiation-induced parotid damage is one of the most common complications in patients with nasopharyngeal carcinoma (NPC) undergoing radiotherapy (RT). Intravoxel incoherent motion (IVIM) magnetic resonance (MR) imaging has been reported for evaluating irradiated parotid damage. However, the changes of IVIM perfusion-related parameters in irradiated parotid glands have not been confirmed by conventional perfusion measurements obtained from dynamic contrast-enhanced (DCE) MR imaging. The purposes of this study were to monitor radiation-induced parotid damage using IVIM and DCE MR imaging and to investigate the correlations between changes of these MR parameters. Eighteen NPC patients underwent bilateral parotid T1-weighted, IVIM and DCE MR imaging pre-RT (2 weeks before RT) and post-RT (4 weeks after RT). Parotid volume; IVIM MR parameters, including apparent diffusion coefficient (ADC), pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f); and DCE MR parameters, including maximum relative enhancement (MRE), time to peak (TTP), Wash in Rate, and the degree of xerostomia were recorded. Correlations of parotid MR parameters with mean radiation dose, atrophy rate and xerostomia degree, as well as the relationships between IVIM and DCE MR parameters, were investigated. From pre-RT to post-RT, all of the IVIM and DCE MR parameters increased significantly (p < 0.001 for ADC, D, f, MRE, Wash in Rate; p = 0.024 for D*; p = 0.037 for TTP). Change rates of ADC, f and MRE were negatively correlated with atrophy rate significantly (all p < 0.05). Significant correlations were observed between the change rates of D* and MRE (r = 0.371, p = 0.026) and between the change rates of D* and TTP (r = 0.396, p = 0.017). The intra- and interobserver reproducibility of IVIM and DCE MR parameters was good to excellent (intraclass correlation coefficient, 0.633–0.983). Early radiation-induced changes of parotid glands could be evaluated by IVIM and DCE MR imaging. Certain IVIM and DCE MR parameters were correlated significantly.