Jae Hoon Jeong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jae Hoon Jeong has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Yeoun Sook Chun
Department of Ophthalmology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
6 shared publications - Jae-Chan Kim
School of Civil, Environmental and Architectural Engineering Korea University Seoul Republic of Korea
5 shared publications Jeom Hwa Han
Fruit Research Division, National Institute of Horticultural & Herbal Science, RDA, Wanju 55365, Korea
4 shared publications- Jin Wook Jeoung
Department of Ophthalmology, Seoul National University Hospital, Seoul, Korea; Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
3 shared publications - Ki Ho Park
Department of Ophthalmology, Seoul National University Hospital, Seoul, Republic of Korea
3 shared publications Nam Ju Moon
Department of Ophthalmology, Chung-Ang University Hospital, Seoul, Korea
3 shared publications
Latest Publications
- Open Access
- 16 September 2026
- Published by Springer Nature in BMC Ophthalmology
Longitudinal changes in objective scatter index and associated clinical factors in phakic eyes
- 16 September 2026
- Published by Springer Nature in BMC Ophthalmology
Open AccessLongitudinal changes in objective scatter index and associated clinical factors in phakic eyes
- Open Access
- 18 November 2023
- Published by Springer Nature in Eye
- Vol. 38  (5) , 980-987
Effect of Bergmeister papilla on disc parameters in spectral domain optical coherence tomography
Objectives: To investigate the morphological characteristics of Bergmeister papilla (BMP), a persistent hyaloid remnant tissue, and its effects on the measurements and repeatability of spectral-domain optical coherence tomography (OCT). Subjects/Methods: The subjects of this prospective cross-sectional study including 83 patients with BMP and 76 unaffected individuals, all had open-angle structures. Images, including a 5-line raster and three consecutive optic disc cube scans centred on the optic disc, were acquired using the Cirrus high-definition OCT. BMP’s structural characteristics were classified based on the raster scan images, and repeatability of acquiring optic nerve head and retinal nerve fibre layer parameters acquisition was analysed by calculating the test-retest standard deviation (Sw), coefficient of variance (CV), and intraclass correlation coefficient. Results: BMPs (n = 83) were categorised into lifting edge (LE) type (63.9%, n = 53), which partially covers the edge of the optic nerve head, and covering disc (CD) type (36.1%, n = 30), which completely covers the cupping area like a cap. The average cup-to-disc ratio (0.58 ± 0.21), vertical cup-to-disc ratio (0.55 ± 0.21), and cup volume (0.22 ± 0.22) of the CD type were lower than those of the LE type (0.66 ± 0.13, 0.64 ± 0.13, and 0.4 ± 0.27, respectively; all P < 0.05). Tolerability indices for repeatability of cup volume (Sw = 0.40 and CV = 0.36) and inferonasal (4 o’clock) retinal nerve fibre layer (Sw = 0.27 and CV = 0.25) in LE-type BMPs exceeded the cut-off value (0.22) and demonstrated stronger correlation with BMP location than that of the controls. Conclusion: Caution should be exercised when interpreting OCT findings in eyes with BMP, as BMP can introduce a pitfall in OCT imaging.
- 18 November 2023
- Published by Springer Nature in Eye
- Vol. 38  (5) , 980-987
Open AccessEffect of Bergmeister papilla on disc parameters in spectral domain optical coherence tomography
Objectives: To investigate the morphological characteristics of Bergmeister papilla (BMP), a persistent hyaloid remnant tissue, and its effects on the measurements and repeatability of spectral-domain optical coherence tomography (OCT). Subjects/Methods: The subjects of this prospective cross-sectional study including 83 patients with BMP and 76 unaffected individuals, all had open-angle structures. Images, including a 5-line raster and three consecutive optic disc cube scans centred on the optic disc, were acquired using the Cirrus high-definition OCT. BMP’s structural characteristics were classified based on the raster scan images, and repeatability of acquiring optic nerve head and retinal nerve fibre layer parameters acquisition was analysed by calculating the test-retest standard deviation (Sw), coefficient of variance (CV), and intraclass correlation coefficient. Results: BMPs (n = 83) were categorised into lifting edge (LE) type (63.9%, n = 53), which partially covers the edge of the optic nerve head, and covering disc (CD) type (36.1%, n = 30), which completely covers the cupping area like a cap. The average cup-to-disc ratio (0.58 ± 0.21), vertical cup-to-disc ratio (0.55 ± 0.21), and cup volume (0.22 ± 0.22) of the CD type were lower than those of the LE type (0.66 ± 0.13, 0.64 ± 0.13, and 0.4 ± 0.27, respectively; all P < 0.05). Tolerability indices for repeatability of cup volume (Sw = 0.40 and CV = 0.36) and inferonasal (4 o’clock) retinal nerve fibre layer (Sw = 0.27 and CV = 0.25) in LE-type BMPs exceeded the cut-off value (0.22) and demonstrated stronger correlation with BMP location than that of the controls. Conclusion: Caution should be exercised when interpreting OCT findings in eyes with BMP, as BMP can introduce a pitfall in OCT imaging.
- Open Access
- 30 January 2023
- Published by Springer Nature in Research Square
Effect of Bergmeister papilla on disc parameters in spectral domain optical coherence tomography
Background: To demonstrate the morphological characteristics of Bergmeister papilla (BMP), a persistent hyaloid remnant tissue, and its effects on the measurements and repeatability of spectral domain optical coherence tomography (OCT). Methods: A prospective cross-sectional study was used to collect 83 patients with BMP and 76 age-matched unaffected individuals from a tertiary care institution. Imaging including 5-line raster and 3 consecutive optic disc cube scans centered on the optic disc were acquired using the Cirrus HD-OCT. Structural characteristics of BMP were classified according to the images of raster scans, and the repeatability of optic nerve head and retinal nerve fiber layer parameters was analyzed by calculating the test-retest standard deviation, coefficient of variance, and intraclass correlation coefficient. Results: BMP was categorized into lifting edge (LE) type where does not cover the entire optic nerve head, but partially covers the corners, and covering disc (CD) type in which covers the entire cupping area like a cap. Among the BMP of 83 eyes, 58 (63.9%) were lifting edge type and 33 (36.1%) were CD type, and some of the optic nerve head parameters in OCT showed significant differences between the CD and LE types and normal control eyes. The analysis of repeatability showed that eyes with LE types affected cup volume and nasal retinal nerve fiber layer parameters and correlated with BMP location. Conclusion: Because BMP might be a pitfall in OCT imaging, it is necessary to be careful when interpreting OCT in an eye with BMP.
- 30 January 2023
- Published by Springer Nature in Research Square
Open AccessEffect of Bergmeister papilla on disc parameters in spectral domain optical coherence tomography
Background: To demonstrate the morphological characteristics of Bergmeister papilla (BMP), a persistent hyaloid remnant tissue, and its effects on the measurements and repeatability of spectral domain optical coherence tomography (OCT). Methods: A prospective cross-sectional study was used to collect 83 patients with BMP and 76 age-matched unaffected individuals from a tertiary care institution. Imaging including 5-line raster and 3 consecutive optic disc cube scans centered on the optic disc were acquired using the Cirrus HD-OCT. Structural characteristics of BMP were classified according to the images of raster scans, and the repeatability of optic nerve head and retinal nerve fiber layer parameters was analyzed by calculating the test-retest standard deviation, coefficient of variance, and intraclass correlation coefficient. Results: BMP was categorized into lifting edge (LE) type where does not cover the entire optic nerve head, but partially covers the corners, and covering disc (CD) type in which covers the entire cupping area like a cap. Among the BMP of 83 eyes, 58 (63.9%) were lifting edge type and 33 (36.1%) were CD type, and some of the optic nerve head parameters in OCT showed significant differences between the CD and LE types and normal control eyes. The analysis of repeatability showed that eyes with LE types affected cup volume and nasal retinal nerve fiber layer parameters and correlated with BMP location. Conclusion: Because BMP might be a pitfall in OCT imaging, it is necessary to be careful when interpreting OCT in an eye with BMP.
- Open Access
- 6 April 2021
- Published by Taylor & Francis in Current Eye Research
- Vol. 46  (10) , 1516-1524
Deep Learning Ensemble Method for Classifying Glaucoma Stages Using Fundus Photographs and Convolutional Neural Networks
Purpose: This study developed and evaluated a deep learning ensemble method to automatically grade the stages of glaucoma depending on its severity. Materials and Methods: After cross-validation of three glaucoma specialists, the final dataset comprised of 3,460 fundus photographs taken from 2,204 patients were divided into three classes: unaffected controls, early-stage glaucoma, and late-stage glaucoma. The mean deviation value of standard automated perimetry was used to classify the glaucoma cases. We modeled 56 convolutional neural networks (CNN) with different characteristics and developed an ensemble system to derive the best performance by combining several modeling results. Results: The proposed method with an accuracy of 88.1% and an average area under the receiver operating characteristic of 0.975 demonstrates significantly better performance to classify glaucoma stages compared to the best single CNN model that has an accuracy of 85.2% and an average area under the receiver operating characteristic of 0.950. The false negative is the least adjacent misprediction, and it is less in the proposed method than in the best single CNN model. Conclusions: The method of averaging multiple CNN models can better classify glaucoma stages by using fundus photographs than a single CNN model. The ensemble method would be useful as a clinical decision support system in glaucoma screening for primary care because it provides high and stable performance with a relatively small amount of data.
- 6 April 2021
- Published by Taylor & Francis in Current Eye Research
- Vol. 46  (10) , 1516-1524
Open AccessDeep Learning Ensemble Method for Classifying Glaucoma Stages Using Fundus Photographs and Convolutional Neural Networks
Purpose: This study developed and evaluated a deep learning ensemble method to automatically grade the stages of glaucoma depending on its severity. Materials and Methods: After cross-validation of three glaucoma specialists, the final dataset comprised of 3,460 fundus photographs taken from 2,204 patients were divided into three classes: unaffected controls, early-stage glaucoma, and late-stage glaucoma. The mean deviation value of standard automated perimetry was used to classify the glaucoma cases. We modeled 56 convolutional neural networks (CNN) with different characteristics and developed an ensemble system to derive the best performance by combining several modeling results. Results: The proposed method with an accuracy of 88.1% and an average area under the receiver operating characteristic of 0.975 demonstrates significantly better performance to classify glaucoma stages compared to the best single CNN model that has an accuracy of 85.2% and an average area under the receiver operating characteristic of 0.950. The false negative is the least adjacent misprediction, and it is less in the proposed method than in the best single CNN model. Conclusions: The method of averaging multiple CNN models can better classify glaucoma stages by using fundus photographs than a single CNN model. The ensemble method would be useful as a clinical decision support system in glaucoma screening for primary care because it provides high and stable performance with a relatively small amount of data.
- Open Access
- 15 July 2020
- Published by Korean Ophthalmological Society in Journal of the Korean Ophthalmological Society
- Vol. 61  (7) , 828-833
Visual Field Patterns of Pseudo-optic Discs in Chorioretinal Coloboma
Purpose: We report three cases of asymptomatic pseudo-optic discs in chorioretinal colobomas highlighted on visual fields patterns. Case summary: (Case 1) A 36-year-old man was found to have a pseudo-optic disc below the optic nerve with a relatively intact neurosensory retina over the lesion. There were no obvious abnormalities on the visual field test, so he underwent no treatment and was followed up every 6 months. (Case 2) A 37-year-old woman diagnosed with glaucoma had abrupt convergence of the neurosensory retinal layers on the boundary of the pseudo-optic disc and a focal retinal nerve fiber layer defect in the inferior sector. An antiglaucoma eyedrop was used to manage the superior hemifield defect, and no significant progression was observed in the structural and functional tests during the 5-year follow-up. (Case 3) A 57-year-old man had a pseudo-optic disc with diffuse retinal nerve fiber layer atrophy in both the superior and inferior sectors. The pseudo-optic disc had protruded into the vitreous cavity. Antiglaucoma eyedrops were used to manage both the superior and inferior hemifield defects, and no significant progression was observed using the structural and functional tests during the 6-year follow-up period. Conclusions: Various visual field results may occur with pseudo-optic discs in chorioretinal colobomas depending on the status of residual retinal tissues and underlying glaucoma. Further evaluations and management options should be considered according to the patient's condition.
- 15 July 2020
- Published by Korean Ophthalmological Society in Journal of the Korean Ophthalmological Society
- Vol. 61  (7) , 828-833
Open AccessVisual Field Patterns of Pseudo-optic Discs in Chorioretinal Coloboma
Purpose: We report three cases of asymptomatic pseudo-optic discs in chorioretinal colobomas highlighted on visual fields patterns. Case summary: (Case 1) A 36-year-old man was found to have a pseudo-optic disc below the optic nerve with a relatively intact neurosensory retina over the lesion. There were no obvious abnormalities on the visual field test, so he underwent no treatment and was followed up every 6 months. (Case 2) A 37-year-old woman diagnosed with glaucoma had abrupt convergence of the neurosensory retinal layers on the boundary of the pseudo-optic disc and a focal retinal nerve fiber layer defect in the inferior sector. An antiglaucoma eyedrop was used to manage the superior hemifield defect, and no significant progression was observed in the structural and functional tests during the 5-year follow-up. (Case 3) A 57-year-old man had a pseudo-optic disc with diffuse retinal nerve fiber layer atrophy in both the superior and inferior sectors. The pseudo-optic disc had protruded into the vitreous cavity. Antiglaucoma eyedrops were used to manage both the superior and inferior hemifield defects, and no significant progression was observed using the structural and functional tests during the 6-year follow-up period. Conclusions: Various visual field results may occur with pseudo-optic discs in chorioretinal colobomas depending on the status of residual retinal tissues and underlying glaucoma. Further evaluations and management options should be considered according to the patient's condition.
- Open Access
- 1 October 2019
- Published by The Korean Society for Bio-Environment Control in Protected Horticulture and Plant Factory
- Vol. 28  (4) , 352-357
Influence of Thermal Treatments on Germination and Internal Compositions of ‘Hongro’ and ‘Fuji’ Apple Trees during Endodormancy
- 1 October 2019
- Published by The Korean Society for Bio-Environment Control in Protected Horticulture and Plant Factory
- Vol. 28  (4) , 352-357
Open AccessInfluence of Thermal Treatments on Germination and Internal Compositions of ‘Hongro’ and ‘Fuji’ Apple Trees during Endodormancy
- Open Access
- 1 July 2019
- Published by The Korean Society for Bio-Environment Control in Protected Horticulture and Plant Factory
- Vol. 28  (3) , 234-242
Skin Coloration and Endogenous Hormonal Changes of ‘Kyoho’ Grape by High Temperature at Veraison
- 1 July 2019
- Published by The Korean Society for Bio-Environment Control in Protected Horticulture and Plant Factory
- Vol. 28  (3) , 234-242
Open AccessSkin Coloration and Endogenous Hormonal Changes of ‘Kyoho’ Grape by High Temperature at Veraison
- Open Access
- 24 October 2017
- Published by CABI Publishing in European Journal of Horticultural Science
- Vol. 82  (5) , 232-238
Night temperatures affect fruit coloration and expressions of anthocyanin biosynthetic genes in ‘Hongro’ apple fruit skins
- 24 October 2017
- Published by CABI Publishing in European Journal of Horticultural Science
- Vol. 82  (5) , 232-238
Open AccessNight temperatures affect fruit coloration and expressions of anthocyanin biosynthetic genes in ‘Hongro’ apple fruit skins
- Open Access
- 1 October 2017
- Published by The Korean Society for Bio-Environment Control in Protected Horticulture and Plant Factory
- Vol. 26  (4) , 346-352
Development of Prediction Model on Fruit Width Using Climatic Environmental Factors in ‘Fuji’ Apple
- 1 October 2017
- Published by The Korean Society for Bio-Environment Control in Protected Horticulture and Plant Factory
- Vol. 26  (4) , 346-352
Open AccessDevelopment of Prediction Model on Fruit Width Using Climatic Environmental Factors in ‘Fuji’ Apple
- Open Access
- 11 March 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17  (1) , 1-8
Ganglion cell-inner plexiform layer and retinal nerve fiber layer thickness according to myopia and optic disc area: a quantitative and three-dimensional analysis
To determine the influences of myopia and optic disc size on ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) thickness profiles obtained by spectral domain optical coherence tomography (OCT). One hundred and sixty-eight eyes of 168 young myopic subjects were recruited and assigned to one of three groups according to their spherical equivalent (SE) values and optic disc area. All underwent Cirrus HD-OCT imaging. The influences of myopia and optic disc size on the GCIPL and RNFL thickness profiles were evaluated by multiple comparisons and linear regression analysis. Three-dimensional surface plots of GCIPL and RNFL thickness corresponding to different combinations of myopia and optic disc size were constructed. Each of the quadrant RNFL thicknesses and their overall average were significantly thinner in high myopia compared to low myopia, except for the temporal quadrant (all Ps ≤0.003). The average and all-sectors GCIPL were significantly thinner in high myopia than in moderate- and/or low-myopia (all Ps ≤0.002). The average OCT RNFL thickness was correlated significantly with SE (0.81 μm/diopter, P < 0.001), axial length (-1.44 μm/mm, P < 0.001), and optic disc area (5.35 μm/mm2, P < 0.001) by linear regression analysis. As for the OCT GCIPL parameters, average GCIPL thickness showed a significant correlation with SE (0.84 μm/diopter, P < 0.001) and axial length (-1.65 μm/mm, P < 0.001). There was no significant correlation of average GCIPL thickness with optic disc area. Three-dimensional curves showed that larger optic discs were associated with increased average RNFL thickness and that more-myopic eyes were associated with decreased average GCIPL and RNFL thickness. Myopia can significantly affect GCIPL and RNFL thickness profiles, and optic disc size has a significant influence on RNFL thickness. The current OCT maps employed in the evaluation of glaucoma should be analyzed in consideration of refractive status and optic disc size.
- 11 March 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17  (1) , 1-8
Open AccessGanglion cell-inner plexiform layer and retinal nerve fiber layer thickness according to myopia and optic disc area: a quantitative and three-dimensional analysis
To determine the influences of myopia and optic disc size on ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) thickness profiles obtained by spectral domain optical coherence tomography (OCT). One hundred and sixty-eight eyes of 168 young myopic subjects were recruited and assigned to one of three groups according to their spherical equivalent (SE) values and optic disc area. All underwent Cirrus HD-OCT imaging. The influences of myopia and optic disc size on the GCIPL and RNFL thickness profiles were evaluated by multiple comparisons and linear regression analysis. Three-dimensional surface plots of GCIPL and RNFL thickness corresponding to different combinations of myopia and optic disc size were constructed. Each of the quadrant RNFL thicknesses and their overall average were significantly thinner in high myopia compared to low myopia, except for the temporal quadrant (all Ps ≤0.003). The average and all-sectors GCIPL were significantly thinner in high myopia than in moderate- and/or low-myopia (all Ps ≤0.002). The average OCT RNFL thickness was correlated significantly with SE (0.81 μm/diopter, P < 0.001), axial length (-1.44 μm/mm, P < 0.001), and optic disc area (5.35 μm/mm2, P < 0.001) by linear regression analysis. As for the OCT GCIPL parameters, average GCIPL thickness showed a significant correlation with SE (0.84 μm/diopter, P < 0.001) and axial length (-1.65 μm/mm, P < 0.001). There was no significant correlation of average GCIPL thickness with optic disc area. Three-dimensional curves showed that larger optic discs were associated with increased average RNFL thickness and that more-myopic eyes were associated with decreased average GCIPL and RNFL thickness. Myopia can significantly affect GCIPL and RNFL thickness profiles, and optic disc size has a significant influence on RNFL thickness. The current OCT maps employed in the evaluation of glaucoma should be analyzed in consideration of refractive status and optic disc size.