JLJung Hee Lee

Jung Hee Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jung Hee Lee has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Geun Ho Im

    Department of Radiology and Center for Molecular and Cellular Imaging, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea

    2 shared publications
  • Jae-Hun Kim

    Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

    2 shared publications
  • Tae Yeon Jeon

    Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

    2 shared publications
  • Byung Kwan Park

    Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea

    1 shared publication
  • Chan Kyo Kim

    Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

    1 shared publication
  • Dongil Choi

    Smart Healthcare Medical Device Research Center , Samsung Medical Center , 81, Irwon-ro , Gangnam-gu, Seoul 06351 , Republic of Korea

    1 shared publication

Latest Publications

  • Biocompatible and Biodegradable Fe3+–Melanoidin Chelate as a Potentially Safe Contrast Agent for Liver MRI

    by Min-Young Lee, Dongil Choi, Moon-Sun Jang, Jung Hee Lee

    Currently, most MRI probes available for clinical use contain gadolinium, which is a high-risk paramagnetic metal that can cause severe side effects (e.g., nephrogenic systemic fibrosis). To limit such side effects and improve diagnostic efficacy, we developed a novel biocompatible MRI contrast agent using glucose, glycine, and paramagnetic iron ion. Glucose and glycine were polymerized into melanoidin by the nonenzymatic Maillard reaction, and Fe3+ was chelated stably with the melanoidin during polymerization. The Fe3+–melanoidin chelate had biocompatibility, biodegradability, and unique contrast effects on both T1- and T2-weighted MRI, depending on the pH and oxidative environments. The administration of the Fe3+–melanoidin chelate to a mouse model of liver cancer showed highly enhanced liver-to-tumor contrasts on both T1- and T2-weighted MRI.


  • Hollow manganese oxide nanoparticle-enhanced MRI of hypoxic-ischaemic brain injury in the neonatal rat

    by Tae Yeon Jeon, Ji Hye Kim, Geun Ho Im, Jae-Hun Kim, Jehoon Yang, So-Young Yoo, Jung Hee Lee

    Objective:To determine the utility of hollow manganese oxide nanoparticle (HMON)-enhanced MRI in depicting and monitoring apoptotic area following hypoxic–ischaemic injury in a neonatal rat brain and to evaluate the longitudinal evolution of hypoxic–ischaemic brain injury (HII) up to 21 days.Methods:The institutional animal care and use committee approval was obtained. The Rice–Vannucci model of HII was used in 7-day-old rat pups (n = 17). MRI was performed 1, 3, 7, 14 and 21 days after HII with intraperitoneal injection of HMON. Relative contrast values in the injured hemisphere and mean apparent diffusion coefficient values were calculated at each time point. Apoptosis and reactive astrogliosis were detected by terminal deoxynucleotidyl transferase-mediated dUTP-biotin nick end-labelling (TUNEL) and glial fibrillary acidic protein staining, and the distribution and intensity of immunohistochemical staining were directly compared with those of HMON enhancement on MRI.Results:The dorsolateral thalamus, hi...


  • Assessment of early therapeutic response to sorafenib in renal cell carcinoma xenografts by dynamic contrast-enhanced and diffusion-weighted MR imaging

    by T Y Jeon, C K Kim, J-H Kim, G H Im, B K Park, J H Lee

    Objective:To investigate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) and diffusion-weighted MRI (DWI) in monitoring early therapeutic response to sorafenib in renal cell carcinoma (RCC) xenograft models.Methods:Sorafenib (40 mg kg−1) was administered orally to BALB/c nude mice (n = 9) bearing subcutaneous tumours of human RCC ACHN xenografts. DCE-MRI and DWI were obtained 0, 1, 3 and 7 days after therapy, and DCE-MRI parameters (Ktrans and ve) and apparent diffusion coefficient (ADC) values were calculated. Tumour size and volume changes were correlated with changes in DCE-MRI parameters or ADC values after therapy.Results:Following therapy, Ktrans showed a significant decrease over time (p = 0.005), whereas ve did not demonstrate significant changes between time points (p = 0.97). ADC values showed a progressive increase over time (p = 0.004). Compared with pre-therapy, Ktrans showed a significant decrease after 3 days of therapy (p = 0.039), and ADC values increased significantly after 7 ...