BMBerton R. Moed

Berton R. Moed

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Berton R. Moed has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • J. Gary Bledsoe

    Department of Orthopaedic Surgery, Saint Louis University School of Medicine, 3635 Vista Avenue, 7th Floor Desloge Towers, St. Louis, MO, 63110, USA

    2 shared publications
  • Adham A. Abdelfattah

    Department of Orthopaedic Surgery, Saint Louis University School of Medicine, 3635 Vista Avenue, 7th Floor Desloge Towers, St. Louis, MO, 63110, USA

    1 shared publication
  • Adham Abdelfattah

    Department of Orthopaedic Surgery, Saint Louis University School of Medicine, 3635 Vista Avenue, 7th Floor Desloge Towers, St. Louis, MO 63110, United States

    1 shared publication
  • Benjamin L. Geer

    1 shared publication
  • Christopher J. Lenarz

    Department of Orthopaedic Surgery, Saint Louis University, 3635 Vista Avenue, Saint Louis, MO 63110, USA

    1 shared publication
  • Christopher P. O’boynick

    Department of Orthopaedic Surgery, Saint Louis University School of Medicine, 3635 Vista Avenue, 7th Floor Desloge Towers, St. Louis 63110, Missouri, United States

    1 shared publication

Latest Publications

  • The Acetabular Fracture Prognostic Nomogram

    by Berton R. Moed, Megan J. BS McMahon, Eric S. Armbrecht

    Objectives: A recently proposed nomogram is an attempt to define the subset of acetabular fractures at risk for primary total hip arthroplasty (THA) within 2 years of open reduction and internal fixation (ORIF). Our objectives were to determine whether this nomogram provides information adequate to reliably (1) prognosticate outcome within 2 years after ORIF or (2) identify optimal initial treatment choice (THA vs. ORIF) for patients with a posterior wall fracture. Design: Retrospective case series. Setting: University level 1 Trauma Center. Patients: From a database of consecutive posterior wall fractures treated by ORIF, 103 patients were identified for analysis: 6 with an unsatisfactory result at less than 2 years and 97 followed 2–14 years. Intervention: Calculation of percent risk of requiring THA within 2 years using the nomogram. Main Outcome Measurements: Comparison of this percent risk to the actual clinical outcome within 2 years after ORIF, measured in 2 ways: (1) THA performed (5 patients) and (2) overall unsatisfactory hip function determined by the modified Merle d'Aubigné score (9 patients total: the 5 with THA plus 4 additional without THA but having unsatisfactory hip function). Results: The calculated percent risk ranged widely, with much overlap among patients having satisfactory or unsatisfactory results of ORIF. Statistical analysis did not yield a clinically useful positive predictive value: 0.25 [95% confidence interval (CI), 0.08–0.53] for THA and 0.44 (95% CI, 0.21–0.69) for an overall unsatisfactory clinical result. Conclusions: The acetabular fracture prognostic nomogram in its current form does not provide sufficient information to prognosticate outcome after ORIF or to determine appropriate surgical management for posterior wall fractures. Level of Evidence: Diagnostic Level I. See Instructions for Authors for a complete description of levels of evidence.


  • Open Access

    Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw

    by Pooria Salari, Berton R. Moed, J. Gary Bledsoe

    A single iliosacral screw placed into the S1 vertebral body has been shown to be clinically unreliable for certain type C pelvic ring injuries. Insertion of a second supplemental iliosacral screw into the S1 or S2 vertebral body has been widely used. However, clinical fixation failures have been reported using this technique, and a supplemental long iliosacral or transsacral screw has been used. The purpose of this study was to compare the biomechanical effect of a supplemental S1 long iliosacral screw versus a transsacral screw in an unstable type C vertically oriented sacral fracture model.


  • Open Access

    Do asymptomatic patients have normal function after percutaneous fixation of the posterior pelvic ring? A case-control pilot study

    by Pooria Salari, Lisa K Cannada, Berton R Moed

    Following treatment of a posterior pelvic disruption, residual deformity or associated injuries can adversely affect functional recovery. No study has been performed on gait and functional outcome after closed reduction and percutaneous screw fixation (CRPSF) of posterior pelvic disruption in clinically asymptomatic patients. The purpose of this study was to determine if gait and functional outcome are different from normal in asymptomatic patients with a posterior pelvic injury after CRPSF, serving as a pilot study in this regard. Six asymptomatic patients with no grossly evident gait abnormality, treated by CRPSF for a posterior pelvic disruption, were included in the study (SG). A control group (CG) of six healthy volunteers was created. All participants completed the 12-Item Short Form Health Survey version 2 (SF-12v2), the Majeed Pelvic Score (MPS), and the Iowa Pelvic Score (IPS). In addition, the participants’ gait was analyzed. Pelvic drop was significantly smaller on the uninjured side in the SG when compared to the injured side in the SG. There was no significant difference between the injured and uninjured side for other gait parameters within the SG. Knee angle at initial contact was significantly greater on the injured side when compared to the CG. The SG scored statistically worse than the CG on the Physical Component Summary part of the SF-12v2. However, when evaluated by age group using national mean scores, the SG differences were minimal. All six patients in our study scored “excellent” on both MPS and IPS. Despite having subclinical alterations in gait, asymptomatic pelvic ring injured patients show minimal, if any, evidence of impaired functional outcome following successful reduction of a posterior pelvic disruption treated by CRPSF.


  • The modified Gibson approach to the acetabulum

    by B.R. Moed

    Providing a surgical approach similar to the Kocher–Langenbeck but having improved anterosuperior access, less risk of injury to branches of the inferior gluteal nerve supplying the anterior portion of the gluteus maximus muscle, and improved cosmesis. Any surgery that would otherwise call for the Kocher–Langenbeck approach. Fractures of the anterior column and/or wall; transtectal T-shaped fractures. Transverse fractures and infra/juxtatectal T-shaped fractures having the major displacement anteriorly at the pelvic brim with only minor posterior displacement. Exposure of the acetabulum fracture through a straight skin incision, developing the plane between the anterior border of the gluteus maximus muscle and the tensor fasciae latae. The gluteus maximus is reflected posteriorly to reveal the underlying deep anatomic structures. Thromboprophylaxis and prophylaxis as indicated for the prevention of heterotopic ossification are instituted. The patient is mobilized as quickly as the associated injuries will allow. Toe-touch weight-bearing is continued for 10–12 weeks. However, progression to full weight-bearing should be individualized. Between 1996 and 2000, 16 patients having a fracture of the acetabulum were operated on through the modified Gibson approach with 15 patients followed up for 1 year or more. Fracture types were posterior wall in eight patients, transverse in one, posterior column and wall in two, transverse and posterior wall in four, and T-shaped in one. There were no intraoperative or immediate postoperative complications. Clinical outcome was determined using a modification of the method developed by Merle d’Aubigné and Postel and was good-to-excellent in 14 patients and poor in one (a patient who developed osteonecrosis of the femoral head unrelated to the approach). Operativer Zugangsweg ähnlich wie nach Kocher-Langenbeck, aber mit besserem anterosuperiorem Zugang, geringerem Verletzungsrisiko für die Äste des N. glutaeus inferior, die den vorderen Anteil des M. glutaeus maximus versorgen, und größerer Unaufffälligkeit. Operationen, bei denen sonst der Zugang nach Kocher-Langenbeck erforderlich wäre. Frakturen der Vordersäule und/oder -wand. Transtektale T-förmige Frakturen. Querfrakturen und infra-/juxtatektale T-förmige Frakturen, bei denen die wesentliche Dislokation vorn am Beckenrand und nur eine kleinere hintere Dislokation besteht. Darstellung der Azetabulumfraktur mittels gerader Hautinzision und Freilegung der Ebene zwischen der vorderen Begrenzung des M. glutaeus maximus und des M. tensor fasciae latae. Der M. glutaeus maximus wird nach hinten umgeklappt, um die tiefen anatomischen Strukturen sichtbar zu machen. Verordnung einer Thromboseprophylaxe sowie, bei entsprechender Indikation, einer Prophylaxe zur Prävention heterotoper Ossifikationen. Der Patient wird so schnell mobilisiert, wie es die begleitenden Verletzungen erlauben. Zehenbelastung für 10–12 Wochen. Jedoch sollte der Übergang zur Vollbelastung individuell gehandhabt werden. Zwischen 1996 und 2000 wurden 16 Patienten mit einer Azetabulumfraktur über einen modifizierten Zugangsweg nach Gibson operiert, bei 15 von ihnen wurde der Verlauf mindestens ein Jahr nachbeobachtet. An Frakturtypen lagen vor: Hinterwandfraktur bei 8, Querfraktur bei einem, Hintersäule und -wand bei zwei, Quer- und Hinterwandfraktur bei 4 sowie T-förmige Fraktur bei einem Patienten. Es gab weder intra- noch unmittelbar postoperative Komplikationen. Das klinische Ergebnis wurde anhand einer Modifikation der von Merle d’Aubigné und Postel entwickelten Methode ermittelt und war bei 14 Patienten gut bis ausgezeichnet sowie bei einem schlecht (Patient, bei dem eine Osteonekrose des Femurkopfes unabhängig vom Zugangsweg auftrat).


  • Disruptions of the Pelvic Ring: An Update: Editorial Comment

    by Berton R. Moed, Mark S. Vrahas

    For more than three decades, since the publication of the first pelvic symposium in Clinical Orthopaedics and Related Research in 1980, much progress has been made in the evaluation and treatment of disruptions of the pelvic ring. Despite this progress, many questions remain unanswered and new ones have been raised. This symposium attempts to address a number of these unresolved issues. Its content should be of interest and value to all those involved in the management of patients sustaining an injury to the pelvic ring. An injury to the pelvic ring often results from a high-energy traumatic event, such as a motor vehicle accident. Therefore, these high-energy pelvic ring disruptions are frequently accompanied by additional musculoskeletal or other system injuries. With the advent of Advanced Trauma Life Support protocols and the stratification of medical centers based on their ability to evaluate and treat those who sustain high-energy trauma, patient survival has dramatically improved