LRLaura Ronchi

Laura Ronchi

*This is an algorithmically generated author record based on publicly available information.

Laura Ronchi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Barriers and facilitators to the implementation of orthodontic mini implants in clinical practice: a systematic review

    by Reint Meursinge Reynders, Laura Ronchi, Luisa Ladu, Nicola Di Girolamo, Jan de Lange, Nia Roberts, Sharon Mickan

    Numerous surveys have shown that orthodontic mini implants (OMIs) are underused in clinical practice. To investigate this implementation issue, we conducted a systematic review to (1) identify barriers and facilitators to the implementation of OMIs for all potential stakeholders and (2) quantify these implementation constructs, i.e., record their prevalence. We also recorded the prevalence of clinicians in the eligible studies that do not use OMIs. Methods were based on our published protocol. Broad-spectrum eligibility criteria were defined. A barrier was defined as any variable that impedes or obstructs the use of OMIs and a facilitator as any variable that eases and promotes their use. Over 30 databases including gray literature were searched until 15 January 2016. The Joanna Briggs Institute tool for studies reporting prevalence and incidence data was used to critically appraise the included studies. Outcomes were qualitatively synthesized, and meta-analyses were only conducted when pre-set criteria were fulfilled. Three reviewers conducted all research procedures independently. We also contacted authors of eligible studies to obtain additional information. Three surveys fulfilled the eligibility criteria. Seventeen implementation constructs were identified in these studies and were extracted from a total of 165 patients and 1391 clinicians. Eight of the 17 constructs were scored by more than 50 % of the pertinent stakeholders. Three of these constructs overlapped between studies. Contacting of authors clarified various uncertainties but was not always successful. Limitations of the eligible studies included (1) the small number of studies; (2) not defining the research questions, i.e., the primary outcomes; (3) the research design (surveys) of the studies and the exclusive use of closed-ended questions; (4) not consulting standards for identifying implementation constructs; (5) the lack of pilot testing; (6) high heterogeneity; (7) the risk of reporting bias; and (8) additional shortcomings. Meta-analyses were not possible because of these limitations. Two eligible studies found that respectively 56.3 % (952/1691) and 40.16 % (439/1093) of clinicians do not use OMIs. Notwithstanding the limitations of the eligible studies, their findings were important because (1) 17 implementation constructs were identified of which 8 were scored by more than 50 % of the stakeholders; (2) the various shortcomings showed how to improve on future implementation studies; and (3) the underuse of OMIs in the selected studies and in the literature demonstrated the need to identify, quantify, and address implementation constructs. Prioritizing of future research questions on OMIs with all pertinent stakeholders is an important first step and could redirect research studies on OMIs towards implementation issues. Patients, clinicians, researchers, policymakers, insurance companies, implant companies, and research sponsors will all be beneficiaries.


  • Open Access

    Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: a systematic review

    by Reint Meursinge Reynders, Luisa Ladu, Laura Ronchi, Nicola Di Girolamo, Jan de Lange, Nia Roberts, Annette Plüddemann

    Most orthodontic mini-implants (OMIs) are inserted between dental roots. The prevalence of contacting these structures is high. Such contacts can cause permanent root damage and implant instability. Increased torque levels during implant insertion (the index test) could be a more accurate and immediate measure for diagnosing implant-root contact (the target condition) than radiographs (the reference standard) and could ultimately lead to a reduction or elimination of X-ray exposure. To address this issue, we asked three questions: (1) whether OMIs with root contact had higher insertion torque values than those without, (2) what is the accuracy of the index test compared with the reference standard to diagnose the target condition and what are the adverse effects of the index test, and (3) whether intermediate torque values have clinical diagnostic utility. Methods were conducted according to our published protocol, which was based on the PRISMA-P 2015 statement. We applied broad spectrum eligibility criteria that included randomized and non-randomized studies on clinical, animal, and cadaver models. Not including such models would be unethical because it could slow down knowledge creation on the adverse effects of implant insertion. We conducted searches in more than 40 electronic databases including MEDLINE and 10 journals were hand-searched. Grey literature and reference lists were also searched. All research procedures were conducted independently by three reviewers. Authors of selected studies were contacted to obtain additional information. Outcomes on the three different research models were analysed separately. Systematic error was assessed with the Cochrane ‘Risk of bias tool’ for non-randomized studies. One clinical, two animal, and two cadaver studies fulfilled the eligibility criteria of the first research question. All studies and subgroups demonstrated higher insertion torque values for OMIs with the target condition than those without. Mean differences (MD) between these effect estimates were statistically significant in one beagle model (MD, 4.64; 95 % CI, 3.50 to 5.79) and three subgroups of cadaver studies (MD, 2.70; 95 % CI, 1.42 to 3.98) (MD, 3.97; 95 % CI, 2.17 to 5.78) (MD, 0.93; 95 % CI, 0.67 to 1.20). Highest mean differences were identified in most self-drilling compared with pre-drilling groups. Clinical heterogeneity between studies was high, and many items were underreported. All studies except one cadaver study scored at least one domain as ‘serious risk’ of bias. No studies addressed the second research question. One cadaver study addressed the third question which showed the importance of recording torque levels during the entire implant insertion process. Responses of contacted authors were helpful, but often difficult to obtain. Implants fractured in one animal and in one cadaver model. All eligible studies scored higher insertion torque values for implants with root contact than those without, but none of these studies assessed the diagnostic accuracy of the index test. The inclusion of non-randomized and animal and cadaver models in this systematic review provided key findings that otherwise would have been wasted. Such studies are important in the context of the wide applicability of this test, the high prevalence of the target condition, and the underreporting of adverse effects of interventions. A protocol for a potential new diagnostic pathway was presented, and the importance of contacting authors was addressed. The applicability of the findings should be interpreted in the context of underreporting and the many limitations of the included studies.


  • Open Access

    Barriers and facilitators to the implementation of orthodontic mini-implants in clinical practice: a protocol for a systematic review and meta-analysis

    by Reint Meursinge Reynders, Laura Ronchi, Luisa Ladu, Nicola Di Girolamo, Jan de Lange, Nia Roberts, Sharon Mickan

    Most orthodontic treatment plans need some form of anchorage to control the reciprocal forces of tooth movement. Orthodontic mini implants (OMIs) have been hailed for having revolutionized orthodontics, because they provide anchorage without depending on the collaboration of patients, they have a favorable effectiveness compared with conventional anchorage devices, and they can be used for a wide scale of treatment objectives. However, surveys have shown that many orthodontists never or rarely use them. To understand the rationale behind this knowledge-to-action gap, we will conduct a systematic review that will identify and quantify potential barriers and facilitators to the implementation of OMIs in clinical practice for all potential stakeholders, i.e., patients, family members, clinicians, office staff, clinic owners, policy makers, etc. The prevalence of clinicians that do not use OMIs will be our secondary outcome. The Preferred Reporting Items for Systematic review and Meta-Analysis Protocols (PRISMA-P) 2015 Statement was adopted as the framework for reporting this manuscript. We will apply broad-spectrum search strategies and will search MEDLINE and more than 40 other databases. We will conduct searches in the gray literature, screen reference lists, and hand-search 12 journals. All study designs, stakeholders, interventions, settings, and languages will be eligible. We will search studies that report on barriers or facilitators to the implementation of orthodontic mini implants (OMIs) in clinical practice. Implementation constructs and their prevalence among pertinent stakeholders will be our primary outcomes. All searching and data extraction procedures will be conducted by three experienced reviewers. We will also contact authors and investigators to obtain additional information on data items and unidentified studies. Risk of bias will be scored with tools designed for the specific study designs. We will assess heterogeneity, meta-biases, and the robustness of the overall evidence of outcomes. We will present findings in a systematic narrative synthesis and plan meta-analyses when pertinent criteria are met. Knowledge creation on this research topic could identify and quantify both expected and unexpected implementation constructs and their stakeholders. Such knowledge can help develop strategies to address implementation issues and redirect future studies on OMIs towards knowledge translation. This could lead to improved patient-health experiences and a reduction in research waste.


  • Open Access

    Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: protocol for a systematic review

    by Reint Meursinge Reynders, Luisa Ladu, Laura Ronchi, Nicola Di Girolamo, Jan de Lange, Nia Roberts, Annette Plüddemann

    Hitting a dental root during the insertion of orthodontic mini-implants (OMIs) is a common adverse effect of this intervention. This condition can permanently damage these structures and can cause implant instability. Increased torque levels (index test) recorded during the insertion of OMIs may provide a more accurate and immediate diagnosis of implant-root contact (target condition) than radiographic imaging (reference standard). An accurate index test could reduce or eliminate X-ray exposure. These issues, the common use of OMIs, the high prevalence of the target condition, and because most OMIs are placed between roots warrant a systematic review. We will assess 1) the diagnostic accuracy and the adverse effects of the index test, 2) whether OMIs with root contact have higher insertion torque values than those without, and 3) whether intermediate torque values have clinical diagnostic utility. The Preferred Reporting Items for Systematic review and Meta-Analysis Protocols (PRISMA-P) 2015 statement was used as a the guideline for reporting this protocol. Inserting implants deliberately into dental roots of human participants would not be approved by ethical review boards and adverse effects of interventions are generally underreported. We will therefore apply broad spectrum eligibility criteria, which will include clinical, animal and cadaver models. Not including these models could slow down knowledge translation. Both randomized and non-randomized research studies will be included. Comparisons of interest and subgroups are pre-specified. We will conduct searches in MEDLINE and more than 40 other electronic databases. We will search the grey literature and reference lists and hand-search ten journals. All methodological procedures will be conducted by three reviewers. Study selection, data extraction and analyses, and protocols for contacting authors and resolving conflicts between reviewers are described. Designed specific risk of bias tools will be tailored to the research question. Different research models will be analysed separately. Parameters for exploring statistical heterogeneity and conducting meta-analyses are pre-specified. The quality of evidence for outcomes will be assessed through the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. The findings of this systematic review will be useful for patients, clinicians, researchers, guideline developers, policymakers, and surgical companies.