Yan Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yan Chen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Jian-Jiang Xu
Department of Ophthalmology, Eye and ENT Hospital of Fudan University, Shanghai, China
2 shared publications - Jiaxu Hong
Department of Ophthalmology, Eye & ENT Hospital, State Key Laboratory of Medical Neurobiology and MOE Frontiers Center for Brain Science, Fudan University, Shanghai, 200031, China
2 shared publications Shuling Pan
Shanghai Aier Eye Hospital, Wuzhong Road, Xuhui District, Shanghai, China
2 shared publications- Yujing Yang
Eye Institute, Eye & ENT Hospital, Shanghai Medical College, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia (Fudan University), Laboratory of Myopia, Chinese Academy of Medical Sciences, China
2 shared publications - Feng Zhao
Department of Ophthalmology and Visual Science, Eye, and ENT Hospital, Shanghai Medical College, Fudan University, 83 Fenyang Road, Shanghai, China
1 shared publication - Huiyu Chen
Department of Ophthalmology and Visual Science, Eye, and ENT Hospital, Shanghai Medical College, Fudan University, 83 Fenyang Road, Shanghai, China
1 shared publication
Latest Publications
- 12 June 2026
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 50 (15) , 5992-6000
The Impact of Full-Incision Double-Eyelid Blepharoplasty on Dry Eye: Association with Short-Term Meibomian Gland Dysfunction and Increased Incomplete Blinking
This study aims to comprehensively evaluate the short-term changes in ocular surface parameters and meibomian gland function following Full-incision double-eyelid blepharoplast. In this observational self-controlled study, 50 patients (100 eyes) undergoing full-incision double-eyelid blepharoplasty were enrolled. Assessments were conducted preoperatively and at 1 week, 1 month, and 3 months postoperatively. These included the Ocular Surface Disease Index (OSDI) questionnaire, fluorescein tear film break-up time (FBUT), corneal fluorescein staining (CFS), Schirmer I test, meibum quality, meibomian gland expressibility, meibomian gland dropout (excluding 1-week), lipid layer thickness (LLT), and incomplete blinking rate (IBR). Statistical comparisons were performed using ANOVA with post-hoc analysis. Compared to baseline, OSDI scores, meibum quality, meibomian gland expressibility, and IBR showed statistically significant deterioration at both 1 week and 1 month post-surgery (all p < 0.001). In contrast, no significant changes were observed in FBUT, CFS, Schirmer I test, LLT, or meibomian gland dropout at any time point. By the 3-month follow-up, all significantly altered parameters-OSDI, meibum quality, expressibility, and IBR-had recovered to levels that were not statistically different from preoperative baseline values. Full-incision double-eyelid blepharoplasty induces a transient but significant dysfunction of the ocular surface and meibomian glands in the early postoperative period, which is closely associated with a sharp increase in incomplete blinking. These findings underscore the importance of proactive postoperative management, including dry eye counseling, artificial tears, and blink training, to enhance patient comfort during the recovery phase. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
- 12 June 2026
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 50 (15) , 5992-6000
The Impact of Full-Incision Double-Eyelid Blepharoplasty on Dry Eye: Association with Short-Term Meibomian Gland Dysfunction and Increased Incomplete Blinking
This study aims to comprehensively evaluate the short-term changes in ocular surface parameters and meibomian gland function following Full-incision double-eyelid blepharoplast. In this observational self-controlled study, 50 patients (100 eyes) undergoing full-incision double-eyelid blepharoplasty were enrolled. Assessments were conducted preoperatively and at 1 week, 1 month, and 3 months postoperatively. These included the Ocular Surface Disease Index (OSDI) questionnaire, fluorescein tear film break-up time (FBUT), corneal fluorescein staining (CFS), Schirmer I test, meibum quality, meibomian gland expressibility, meibomian gland dropout (excluding 1-week), lipid layer thickness (LLT), and incomplete blinking rate (IBR). Statistical comparisons were performed using ANOVA with post-hoc analysis. Compared to baseline, OSDI scores, meibum quality, meibomian gland expressibility, and IBR showed statistically significant deterioration at both 1 week and 1 month post-surgery (all p < 0.001). In contrast, no significant changes were observed in FBUT, CFS, Schirmer I test, LLT, or meibomian gland dropout at any time point. By the 3-month follow-up, all significantly altered parameters-OSDI, meibum quality, expressibility, and IBR-had recovered to levels that were not statistically different from preoperative baseline values. Full-incision double-eyelid blepharoplasty induces a transient but significant dysfunction of the ocular surface and meibomian glands in the early postoperative period, which is closely associated with a sharp increase in incomplete blinking. These findings underscore the importance of proactive postoperative management, including dry eye counseling, artificial tears, and blink training, to enhance patient comfort during the recovery phase. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
- Open Access
- 25 August 2021
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 69 (9) , 2389-2394
A clinical study on the correlation between demodex infestation and ocular surface changes in patients with meibomian gland dysfunction
Purpose: To observe the effect of demodex infection on the ocular surface changes of patients with meibomian gland dysfunction (MGD) and analyze the correlation between the number of demodex and the changes of the ocular surface. Methods: Hundred patients with MGD aged 18–70 years who visited the dry eye center of Shanghai Aier Eye Hospital were recruited. All patients were examined with in vivo confocal microscopy to quantify the demodex and divided them into two groups (demodex negative group and demodex positive group) according to the number of demodex mites. The subjects underwent questionnaires of ocular surface disease index (OSDI) and a series of examinations. Parameters including the OSDI score, fluorescein tear film break-up time (FBUT), meibum quality, meibum gland expressibility, meibomian gland dropout (MG dropout), and ocular redness were recorded and compared between the two groups. The correlation between the number of demodex and the ocular surface changes was further analyzed. Results: Among 100 patients, 51 were positive for demodex. The demodex-positive group showed significantly increased scores of OSDI (24.41 ± 3.43 vs 20.98 ± 2.31, P = 0.00), ocular redness score (1.38 ± 0.46 vs 1.00 ± 0.30, P = 0.00), and MG dropout (3.00 ± 1.13 vs 2.18 ± 0.64, P = 0.00) and decreased FBUT (6.40 ± 1.63 vs 6.54 ± 1.83, P = 0.00), compared to the demodex-negative group. A significant correlation was noted between the number of demodex and OSDI, ocular redness, and FBUT. Conclusion: Ocular demodex infestation might play a role in the ocular surface discomfort, inflammation, and meibomian gland dropout in MGD patients. It is necessary to pay attention to the examination and treatment of demodex mite in patients with MGD.
- 25 August 2021
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 69 (9) , 2389-2394
Open AccessA clinical study on the correlation between demodex infestation and ocular surface changes in patients with meibomian gland dysfunction
Purpose: To observe the effect of demodex infection on the ocular surface changes of patients with meibomian gland dysfunction (MGD) and analyze the correlation between the number of demodex and the changes of the ocular surface. Methods: Hundred patients with MGD aged 18–70 years who visited the dry eye center of Shanghai Aier Eye Hospital were recruited. All patients were examined with in vivo confocal microscopy to quantify the demodex and divided them into two groups (demodex negative group and demodex positive group) according to the number of demodex mites. The subjects underwent questionnaires of ocular surface disease index (OSDI) and a series of examinations. Parameters including the OSDI score, fluorescein tear film break-up time (FBUT), meibum quality, meibum gland expressibility, meibomian gland dropout (MG dropout), and ocular redness were recorded and compared between the two groups. The correlation between the number of demodex and the ocular surface changes was further analyzed. Results: Among 100 patients, 51 were positive for demodex. The demodex-positive group showed significantly increased scores of OSDI (24.41 ± 3.43 vs 20.98 ± 2.31, P = 0.00), ocular redness score (1.38 ± 0.46 vs 1.00 ± 0.30, P = 0.00), and MG dropout (3.00 ± 1.13 vs 2.18 ± 0.64, P = 0.00) and decreased FBUT (6.40 ± 1.63 vs 6.54 ± 1.83, P = 0.00), compared to the demodex-negative group. A significant correlation was noted between the number of demodex and OSDI, ocular redness, and FBUT. Conclusion: Ocular demodex infestation might play a role in the ocular surface discomfort, inflammation, and meibomian gland dropout in MGD patients. It is necessary to pay attention to the examination and treatment of demodex mite in patients with MGD.
- 21 April 2020
- Published by Springer Nature in International Ophthalmology
- Vol. 40 (8) , 2065-2075
Femtosecond laser-assisted Descemet’s stripping endothelial keratoplasty: a prospective study of 6-month visual outcomes, corneal thickness and endothelial cell loss
Purpose To report 6-month outcomes of visual acuity, the corneal thickness and endothelial cell density (ECD) in patients undergoing femtosecond laser-assisted Descemet’s stripping endothelial keratoplasty (FS-DSEK). Methods This prospective, consecutive, interventional series examined 25 eyes of 25 patients who underwent FS-DSEK for Fuchs endothelial dystrophy and bullous keratopathy. The pre-cut corneal endothelial graft thickness (CET) was 150 µm. Best-corrected visual acuity (BCVA), central corneal thickness (CCT), donor CET, recipient corneal stromal thickness (CST) and ECD were assessed at 1 week and 1, 2, 3 and 6 months postoperatively. Results The mean BCVA at 6 months was 0.76 ± 0.35 logMAR units, improving from 1.54 ± 0.52 logMAR. CCT decreased significantly, from 759.8 ± 152.4 µm at 1 week to 631.7 ± 79.7 µm at 6 months (P = 0.001) postoperatively. CET recovered to 153.4 ± 33.7 µm (P = 0.076) at 6 months as pre-cut status. The CST decreased from 561.5 ± 96.3 µm at 1 week to 479.7 ± 57.9 µm at 6 months (P < 0.001). Preoperatively, the donor ECD was 2747.6 ± 255.4 cells/mm2, and the ECD decreased to 1729.1 ± 562.9 cells/mm2 at 6 months, for a peak ECD loss of 36.86%. A greater decrease in CST observed from 1 week to 6 months postoperatively correlated with a lower ECD loss (P = 0.019) and a lower preoperative ECD (P = 0.012). However, a thinner CET correlated with a higher preoperative ECD (P = 0.028). Conclusions FS-DSEK is a safe and effective surgical alternative for corneal endothelial decompensation. The donor ECD and its changes could be used as predictive factors for the improvement of CST and CET.
- 21 April 2020
- Published by Springer Nature in International Ophthalmology
- Vol. 40 (8) , 2065-2075
Femtosecond laser-assisted Descemet’s stripping endothelial keratoplasty: a prospective study of 6-month visual outcomes, corneal thickness and endothelial cell loss
Purpose To report 6-month outcomes of visual acuity, the corneal thickness and endothelial cell density (ECD) in patients undergoing femtosecond laser-assisted Descemet’s stripping endothelial keratoplasty (FS-DSEK). Methods This prospective, consecutive, interventional series examined 25 eyes of 25 patients who underwent FS-DSEK for Fuchs endothelial dystrophy and bullous keratopathy. The pre-cut corneal endothelial graft thickness (CET) was 150 µm. Best-corrected visual acuity (BCVA), central corneal thickness (CCT), donor CET, recipient corneal stromal thickness (CST) and ECD were assessed at 1 week and 1, 2, 3 and 6 months postoperatively. Results The mean BCVA at 6 months was 0.76 ± 0.35 logMAR units, improving from 1.54 ± 0.52 logMAR. CCT decreased significantly, from 759.8 ± 152.4 µm at 1 week to 631.7 ± 79.7 µm at 6 months (P = 0.001) postoperatively. CET recovered to 153.4 ± 33.7 µm (P = 0.076) at 6 months as pre-cut status. The CST decreased from 561.5 ± 96.3 µm at 1 week to 479.7 ± 57.9 µm at 6 months (P < 0.001). Preoperatively, the donor ECD was 2747.6 ± 255.4 cells/mm2, and the ECD decreased to 1729.1 ± 562.9 cells/mm2 at 6 months, for a peak ECD loss of 36.86%. A greater decrease in CST observed from 1 week to 6 months postoperatively correlated with a lower ECD loss (P = 0.019) and a lower preoperative ECD (P = 0.012). However, a thinner CET correlated with a higher preoperative ECD (P = 0.028). Conclusions FS-DSEK is a safe and effective surgical alternative for corneal endothelial decompensation. The donor ECD and its changes could be used as predictive factors for the improvement of CST and CET.
- Open Access
- 20 September 2016
- Published by Springer Nature in BMC Ophthalmology
- Vol. 16 (1) , 1-6
Measurement of corneal and limbal epithelial thickness by anterior segment optical coherence tomography and in vivo confocal microscopy
To compare corneal epithelial thickness (CET) and limbal epithelial thickness (LET) measured by anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscope (IVCM) in normal subjects, and evaluate the consistency between them. Thirty-eight normal subjects (17 men and 21 women) were enrolled in this study. AS-OCT was performed at central cornea and the superior, inferior, nasal and temporal limbus. Then followed by IVCM examination performed at the same location. Agreement was analyzed by mean difference (AS-OCT minus IVCM), 95 % limits of agreement (LoA) (1.96 standard deviation of the difference), and Bland-Altman analysis. The average CET measured by AS-OCT and IVCM was 55.6 ± 4.0 μm and 51.9 ± 4.9 μm respectively. The value measured by IVCM was significantly lower than that measured by AS-OCT (P = 0.015). The average LET values tested by AS-OCT were 10.3 and 10.9 % less at nasal and temporal quadrant (nasal: P = 0.019, temporal: P = 0.003), and were similar as those measured by IVCM at superior and inferior quadrant. In subjects older than 40 years, CET and LET values measured by AS-OCT were significantly higher than those by IVCM. Such differences were not found in subjects ≤ 40 years old. CET values measured by IVCM are lower than those by AS-OCT, while LET values measured by two devices have good agreement. These two techniques have their own advantages in measuring epithelial thickness and are mutually complementary.
- 20 September 2016
- Published by Springer Nature in BMC Ophthalmology
- Vol. 16 (1) , 1-6
Open AccessMeasurement of corneal and limbal epithelial thickness by anterior segment optical coherence tomography and in vivo confocal microscopy
To compare corneal epithelial thickness (CET) and limbal epithelial thickness (LET) measured by anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscope (IVCM) in normal subjects, and evaluate the consistency between them. Thirty-eight normal subjects (17 men and 21 women) were enrolled in this study. AS-OCT was performed at central cornea and the superior, inferior, nasal and temporal limbus. Then followed by IVCM examination performed at the same location. Agreement was analyzed by mean difference (AS-OCT minus IVCM), 95 % limits of agreement (LoA) (1.96 standard deviation of the difference), and Bland-Altman analysis. The average CET measured by AS-OCT and IVCM was 55.6 ± 4.0 μm and 51.9 ± 4.9 μm respectively. The value measured by IVCM was significantly lower than that measured by AS-OCT (P = 0.015). The average LET values tested by AS-OCT were 10.3 and 10.9 % less at nasal and temporal quadrant (nasal: P = 0.019, temporal: P = 0.003), and were similar as those measured by IVCM at superior and inferior quadrant. In subjects older than 40 years, CET and LET values measured by AS-OCT were significantly higher than those by IVCM. Such differences were not found in subjects ≤ 40 years old. CET values measured by IVCM are lower than those by AS-OCT, while LET values measured by two devices have good agreement. These two techniques have their own advantages in measuring epithelial thickness and are mutually complementary.
- Open Access
- 6 June 2012
- Published by Springer Nature in BMC Public Health
- Vol. 12 (1) , 409
Analysis of medical expenditure and socio-economic status in patients with ocular chemical burns in East China: a retrospective study
Background: Little has been known regarding the relationship between ocular chemical injury and victims’ medical expenditure, income loss and socio-economic status changes. So we conduct this retrospective cross-sectional study in patients with ocular chemical burns in East China.Methods: Fifty-six patients were enrolled and required to complete a self-report questionnaire consisting of the following contents: entire expenditure on medical treatment; the victims’ personal and household per capita income, and income loss caused by the injury; and the changes of socioeconomic status as well.Results: The median expense of medical treatment was CNY 40,000 (approximately US$5,900). The medical expenditure rose significantly with increased injury severity, prolonged hospital stay, and increased frequency of surgery. More than half victims (51.8 %, 29/56) paid all or the majority of medical expense by themselves. The expense of only 5 victims was mainly paid by medical insurance, accounting for less than ten percent (8.9 %, 5/56). The victims’ personal and household per capita income both decreased significantly after the injury, with the median reduction being CNY 24,000 and CNY 7,800 (approximately US$3600 and US$1200) per year respectively. The reduction amplitude of personal and household per capita income rose with increased injury severity and prolonged time of care required. The injury caused emotional depression or anxiety in 76.8 % (43/56) victims, and the relationship with their relatives got worse in 51.9 % (29/56) patients. Moreover, only 21.4 % (12/56) patients felt that the whole society gave them care and concern after the injury, whereas 46.4 % (26/56) and 28.6 % (16/56) felt indifference or discrimination from society as a whole (X2 = 16.916, P = 0.028).Conclusions: The medical expense was a huge economic burden to most victims of ocular chemical burns, and personal and household per capita income of the victims decreased significantly after injury, both of which had a close relationship with the injury severity. Formal legislation was urgently needed to compel the employer to purchase injury or medical insurance and provide more compulsory protection to the population working in high risk occupations. In addition, psychological counseling and instruction shouldn’t be neglected in the aid and treatment of victims.
- 6 June 2012
- Published by Springer Nature in BMC Public Health
- Vol. 12 (1) , 409
Open AccessAnalysis of medical expenditure and socio-economic status in patients with ocular chemical burns in East China: a retrospective study
Background: Little has been known regarding the relationship between ocular chemical injury and victims’ medical expenditure, income loss and socio-economic status changes. So we conduct this retrospective cross-sectional study in patients with ocular chemical burns in East China.Methods: Fifty-six patients were enrolled and required to complete a self-report questionnaire consisting of the following contents: entire expenditure on medical treatment; the victims’ personal and household per capita income, and income loss caused by the injury; and the changes of socioeconomic status as well.Results: The median expense of medical treatment was CNY 40,000 (approximately US$5,900). The medical expenditure rose significantly with increased injury severity, prolonged hospital stay, and increased frequency of surgery. More than half victims (51.8 %, 29/56) paid all or the majority of medical expense by themselves. The expense of only 5 victims was mainly paid by medical insurance, accounting for less than ten percent (8.9 %, 5/56). The victims’ personal and household per capita income both decreased significantly after the injury, with the median reduction being CNY 24,000 and CNY 7,800 (approximately US$3600 and US$1200) per year respectively. The reduction amplitude of personal and household per capita income rose with increased injury severity and prolonged time of care required. The injury caused emotional depression or anxiety in 76.8 % (43/56) victims, and the relationship with their relatives got worse in 51.9 % (29/56) patients. Moreover, only 21.4 % (12/56) patients felt that the whole society gave them care and concern after the injury, whereas 46.4 % (26/56) and 28.6 % (16/56) felt indifference or discrimination from society as a whole (X2 = 16.916, P = 0.028).Conclusions: The medical expense was a huge economic burden to most victims of ocular chemical burns, and personal and household per capita income of the victims decreased significantly after injury, both of which had a close relationship with the injury severity. Formal legislation was urgently needed to compel the employer to purchase injury or medical insurance and provide more compulsory protection to the population working in high risk occupations. In addition, psychological counseling and instruction shouldn’t be neglected in the aid and treatment of victims.