Dong Lv
Research Subjects
Research Interests
Dong Lv has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Aiqiang Xu
Shandong Center for Disease Control and Prevention, Jinan, China
1 shared publication - Haiyan Wang
Shandong Provincial Key Laboratory of Infectious Disease Control and Prevention; Shandong Center for Disease Control and Prevention, No. 16992 Jingshi Road, Jinan, 250014, People's Republic of China
1 shared publication - Huaning Zhang
Shandong Center for Disease Control and Prevention, Shandong Province Key Laboratory of Intelligent Monitoring, Early Warning, and Prevention of Infectious Diseases, Jinan, China
1 shared publication - Nan Zhou
Key Laboratory of Environmental Medicine and Engineering of Ministry of Education, Department of Epidemiology and Health Statistics, School of Public Health Southeast University Nanjing China
1 shared publication - Pei Wang
Department of Epidemiology, School of Public Health, Shandong University, No. 44 Wenhuaxi Road, Jinan, 250012, People's Republic of China
1 shared publication - Peibin Hou
Academy of Preventive Medicine, Shandong University, Jinan, 250014, China
1 shared publication
Latest Publications
- Open Access
- 13 September 2016
- Published by Springer Nature in Virology Journal
- Vol. 13 (1) , 1-8
Continuous detection and genetic diversity of human rotavirus A in sewage in eastern China, 2013–2014
Rotavirus is the leading viral agent for pediatric gastroenteritis. However, the case-based surveillance for rotavirus is limited in China, and its circulation in the environment is not well investigated. From 2013 to 2014, rotavirus was detected in raw sewage samples of Jinan and Linyi by quantitative PCR (qPCR) and conventional reverse transcription PCR (RT-PCR). After sequenced and genotyped, sequences analysis was conducted. A total of 46 sewage samples were collected monthly for the detection of rotavirus, and rotavirus was positive in 43 samples (93.5 %, 43/46). By quantitative assessment, the concentrations of rotavirus in raw sewage ranged from 4.1 × 103 to 1.3 × 106 genome copies (GC)/L in Jinan, and from 1.5 × 103 to 3.0 × 105 GC/L in Linyi. A total of 318 sequences of 5 G-genotypes and 318 sequences of 5 P-genotypes were obtained. G9 (91.8 %, 292/318) and P[8] (56.0 %, 178/318) were the most common G- and P-genotype, respectively. Multiple transmission lineages were recognized in these genotypes. Interestingly, an intragenic recombination event between two G9 lineages was observed. This study provided the first report of comprehensive environmental surveillance for rotavirus in China. The results suggest that the concentration of rotavirus in raw sewage was high, and multiple rotavirus transmission lineages continuously co-circulated in Shandong.
- 13 September 2016
- Published by Springer Nature in Virology Journal
- Vol. 13 (1) , 1-8
Open AccessContinuous detection and genetic diversity of human rotavirus A in sewage in eastern China, 2013–2014
Rotavirus is the leading viral agent for pediatric gastroenteritis. However, the case-based surveillance for rotavirus is limited in China, and its circulation in the environment is not well investigated. From 2013 to 2014, rotavirus was detected in raw sewage samples of Jinan and Linyi by quantitative PCR (qPCR) and conventional reverse transcription PCR (RT-PCR). After sequenced and genotyped, sequences analysis was conducted. A total of 46 sewage samples were collected monthly for the detection of rotavirus, and rotavirus was positive in 43 samples (93.5 %, 43/46). By quantitative assessment, the concentrations of rotavirus in raw sewage ranged from 4.1 × 103 to 1.3 × 106 genome copies (GC)/L in Jinan, and from 1.5 × 103 to 3.0 × 105 GC/L in Linyi. A total of 318 sequences of 5 G-genotypes and 318 sequences of 5 P-genotypes were obtained. G9 (91.8 %, 292/318) and P[8] (56.0 %, 178/318) were the most common G- and P-genotype, respectively. Multiple transmission lineages were recognized in these genotypes. Interestingly, an intragenic recombination event between two G9 lineages was observed. This study provided the first report of comprehensive environmental surveillance for rotavirus in China. The results suggest that the concentration of rotavirus in raw sewage was high, and multiple rotavirus transmission lineages continuously co-circulated in Shandong.