Christophe Nich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christophe Nich has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Moussa Hamadouche
Laboratoire de Biomécanique et Biomatériaux Ostéo-Articulaires – UMR CNRS 7052, Faculté de Médecine, Université Paris 7, Paris, France
3 shared publications- Stuart Barry Goodman
Stanford University Medical Center
3 shared publications Allison J. Rao
Department of Orthopaedic Surgery Stanford University School of Medicine Stanford California
2 shared publications- Arnaud Marchadier
INSERM U 658‐IPROS CHR Orléans BP 2439 Orléans Cedex 1 France
2 shared publications Bernard Augereau
European Hospital of Paris
2 shared publicationsHervé Petite
Laboratoire de Biomécanique et Biomatériaux Ostéo-Articulaires – UMR CNRS 7052, Faculté de Médecine, Université Paris 7, Paris, France
2 shared publications
Latest Publications
- 1 January 2020
- Published by Elsevier in Journal of Orthopaedics
- Vol. 17, 69-72
Perioperative complications and causes of 30- and 90-day readmission after direct anterior approach primary total hip arthroplasty
- 1 January 2020
- Published by Elsevier in Journal of Orthopaedics
- Vol. 17, 69-72
Perioperative complications and causes of 30- and 90-day readmission after direct anterior approach primary total hip arthroplasty
- 8 March 2018
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (11) , 2543-2548
Outcomes after revision of metal on metal hip resurfacing to total arthroplasty using the direct anterior approach
Function after revision total hip arthroplasty (THA) in failed metal-on-metal (MoM) hip resurfacing arthroplasty (HRA) is variable, but post-operative complication rates are reportedly high. We hypothesized HRA conversion to THA using the direct anterior approach (DAA) would be associated with optimal outcome.
- 8 March 2018
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (11) , 2543-2548
Outcomes after revision of metal on metal hip resurfacing to total arthroplasty using the direct anterior approach
Function after revision total hip arthroplasty (THA) in failed metal-on-metal (MoM) hip resurfacing arthroplasty (HRA) is variable, but post-operative complication rates are reportedly high. We hypothesized HRA conversion to THA using the direct anterior approach (DAA) would be associated with optimal outcome.
- 1 February 2017
- Published by Wolters Kluwer Health
- Vol. 475 (2) , 384-386
CORR Insights®: Two- to 4-year Followup of a Short Stem THA Construct: Excellent Fixation, Thigh Pain a Concern
- 1 February 2017
- Published by Wolters Kluwer Health
- Vol. 475 (2) , 384-386
CORR Insights®: Two- to 4-year Followup of a Short Stem THA Construct: Excellent Fixation, Thigh Pain a Concern
- 1 November 2015
- Published by Wolters Kluwer Health
- Vol. 473 (11) , 3465-3467
CORR Insights®: What Is the Rerevision Rate After Revising a Hip Resurfacing Arthroplasty? Analysis From the AOANJRR
Hip resurfacing arthroplasty has been proposed as an alternative to standard THA for young adults with advanced osteoarthritis. There now exists good evidence to demonstrate excellent short-term functional results and lower dislocation rates compared to standard THA. However, the analysis of national joint registries [3, 5] revealed higher revision rates for hip resurfacing arthroplasty devices, notably metal-on-metal (MoM) bearings in women, compared with THA devices. To date, we have few data to guide our choices regarding the right technical choices (such as implant selection) or to inform our prognostic estimates when considering the revision of a failed hip resurfacing arthroplasty. The current study by Wong and colleagues attempts to evaluate the rerevision rate for hip resurfacing arthroplasty revisions, with a focus on whether the acetabular component alone, or both the acetabular and femoral components were revised. The authors analyzed the Australian Orthopae ...
- 1 November 2015
- Published by Wolters Kluwer Health
- Vol. 473 (11) , 3465-3467
CORR Insights®: What Is the Rerevision Rate After Revising a Hip Resurfacing Arthroplasty? Analysis From the AOANJRR
Hip resurfacing arthroplasty has been proposed as an alternative to standard THA for young adults with advanced osteoarthritis. There now exists good evidence to demonstrate excellent short-term functional results and lower dislocation rates compared to standard THA. However, the analysis of national joint registries [3, 5] revealed higher revision rates for hip resurfacing arthroplasty devices, notably metal-on-metal (MoM) bearings in women, compared with THA devices. To date, we have few data to guide our choices regarding the right technical choices (such as implant selection) or to inform our prognostic estimates when considering the revision of a failed hip resurfacing arthroplasty. The current study by Wong and colleagues attempts to evaluate the rerevision rate for hip resurfacing arthroplasty revisions, with a focus on whether the acetabular component alone, or both the acetabular and femoral components were revised. The authors analyzed the Australian Orthopae ...
- 11 August 2015
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 474 (2) , 383-385
CORR Insights®: Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners
- 11 August 2015
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 474 (2) , 383-385
CORR Insights®: Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners
- 1 August 2015
- Published by Elsevier in Journal of Infection
- Vol. 71 (2) , 200-206
Dramatic reduction of clindamycin serum concentration in staphylococcal osteoarticular infection patients treated with the oral clindamycin-rifampicin combination
- 1 August 2015
- Published by Elsevier in Journal of Infection
- Vol. 71 (2) , 200-206
Dramatic reduction of clindamycin serum concentration in staphylococcal osteoarticular infection patients treated with the oral clindamycin-rifampicin combination
- 1 November 2014
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 100 (7) , 721-726
Does partial tear repair of adjacent tendons improve the outcome of supraspinatus tendonfull-thickness tear reinsertion?
- 1 November 2014
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 100 (7) , 721-726
Does partial tear repair of adjacent tendons improve the outcome of supraspinatus tendonfull-thickness tear reinsertion?
- 1 January 2014
- Published by Begell House Inc. Publishers in Journal of Long-Term Effects of Medical Implants
- Vol. 24 (4) , 259-265
Role of Macrophages in the Biological Reaction to Wear Debris from Joint Replacements
Normal usage of total joint replacements results in the production of wear debris and other byproducts. In particular, polyethylene particles are heavily involved in the stimulation of local and systemic biological reactions resulting in chronic inflammation, periprosthetic bone resorption (osteolysis), and, eventually, implant loosening. As sentinels of the innate immune system, cells of the monocyte/macrophage lineage initiate the inflammatory cascade that leads to osteolysis. The biological processes involved are complex, based on the unique properties of the monocytes/macrophages, including sensing, chemotaxis, phagocytosis, and adaptive stimulation. The interaction with wear debris triggers the release of pro-inflammatory factors, such as TNF-α, IL-1, and others, pro-osteoclastic factors such as RANKL, and chemokines, such as MCP-1 and MIP-1, all being crucial to the recruitment, migration, differentiation, and ultimately activation of bone resorbing osteoclasts. In parallel, other distinct macrophage populations inhibit inflammation and mitigate its consequences on the bone-implant interface. Here, the role of the monocyte/macrophage cell lineage in the initiation and maintenance of the host inflammatory response to wear debris and subsequent periprosthetic osteolysis is presented.
- 1 January 2014
- Published by Begell House Inc. Publishers in Journal of Long-Term Effects of Medical Implants
- Vol. 24 (4) , 259-265
Role of Macrophages in the Biological Reaction to Wear Debris from Joint Replacements
Normal usage of total joint replacements results in the production of wear debris and other byproducts. In particular, polyethylene particles are heavily involved in the stimulation of local and systemic biological reactions resulting in chronic inflammation, periprosthetic bone resorption (osteolysis), and, eventually, implant loosening. As sentinels of the innate immune system, cells of the monocyte/macrophage lineage initiate the inflammatory cascade that leads to osteolysis. The biological processes involved are complex, based on the unique properties of the monocytes/macrophages, including sensing, chemotaxis, phagocytosis, and adaptive stimulation. The interaction with wear debris triggers the release of pro-inflammatory factors, such as TNF-α, IL-1, and others, pro-osteoclastic factors such as RANKL, and chemokines, such as MCP-1 and MIP-1, all being crucial to the recruitment, migration, differentiation, and ultimately activation of bone resorbing osteoclasts. In parallel, other distinct macrophage populations inhibit inflammation and mitigate its consequences on the bone-implant interface. Here, the role of the monocyte/macrophage cell lineage in the initiation and maintenance of the host inflammatory response to wear debris and subsequent periprosthetic osteolysis is presented.
- 9 April 2013
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 101 (10) , 3033-3045
Macrophages—Key cells in the response to wear debris from joint replacements
The generation of wear debris is an inevitable result of normal usage of joint replacements. Wear debris particles stimulate local and systemic biological reactions resulting in chronic inflammation, periprosthetic bone destruction, and eventually, implant loosening, and revision surgery. The latter may be indicated in up to 15% patients in the decade following the arthroplasty using conventional polyethylene. Macrophages play multiple roles in both inflammation and in maintaining tissue homeostasis. As sentinels of the innate immune system, they are central to the initiation of this inflammatory cascade, characterized by the release of proinflammatory and pro‐osteoclastic factors. Similar to the response to pathogens, wear particles elicit a macrophage response, based on the unique properties of the cells belonging to this lineage, including sensing, chemotaxis, phagocytosis, and adaptive stimulation. The biological processes involved are complex, redundant, both local and systemic, and highly adaptive. Cells of the monocyte/macrophage lineage are implicated in this phenomenon, ultimately resulting in differentiation and activation of bone resorbing osteoclasts. Simultaneously, other distinct macrophage populations inhibit inflammation and protect the bone‐implant interface from osteolysis. Here, the current knowledge about the physiology of monocyte/macrophage lineage cells is reviewed. In addition, the pattern and consequences of their interaction with wear debris and the recent developments in this field are presented. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 101A: 3033–3045, 2013.
- 9 April 2013
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 101 (10) , 3033-3045
Macrophages—Key cells in the response to wear debris from joint replacements
The generation of wear debris is an inevitable result of normal usage of joint replacements. Wear debris particles stimulate local and systemic biological reactions resulting in chronic inflammation, periprosthetic bone destruction, and eventually, implant loosening, and revision surgery. The latter may be indicated in up to 15% patients in the decade following the arthroplasty using conventional polyethylene. Macrophages play multiple roles in both inflammation and in maintaining tissue homeostasis. As sentinels of the innate immune system, they are central to the initiation of this inflammatory cascade, characterized by the release of proinflammatory and pro‐osteoclastic factors. Similar to the response to pathogens, wear particles elicit a macrophage response, based on the unique properties of the cells belonging to this lineage, including sensing, chemotaxis, phagocytosis, and adaptive stimulation. The biological processes involved are complex, redundant, both local and systemic, and highly adaptive. Cells of the monocyte/macrophage lineage are implicated in this phenomenon, ultimately resulting in differentiation and activation of bone resorbing osteoclasts. Simultaneously, other distinct macrophage populations inhibit inflammation and protect the bone‐implant interface from osteolysis. Here, the current knowledge about the physiology of monocyte/macrophage lineage cells is reviewed. In addition, the pattern and consequences of their interaction with wear debris and the recent developments in this field are presented. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 101A: 3033–3045, 2013.
- 1 January 2013
- Published by Elsevier in Biomaterials
- Vol. 34 (3) , 641-650
Role of direct estrogen receptor signaling in wear particle-induced osteolysis
- 1 January 2013
- Published by Elsevier in Biomaterials
- Vol. 34 (3) , 641-650
Role of direct estrogen receptor signaling in wear particle-induced osteolysis