Timothy Keith Williams
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Timothy Keith Williams has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Lucas P. Neff
Department of Surgery, UC Davis Medical Center, Sacramento, California
3 shared publicationsRachel M. Russo
Department of Surgery, UC Davis Medical Center, Sacramento, California †Department of General Surgery, David Grant USAF Medical Center, Travis Air Force Base, California ‡Department of Surgery, Uniformed Services University of the Health Sciences, Bethesda, Maryland §Department of Emergency Medicine, University of California Davis Medical Center, Sacramento, California ||Department of Vascular and Endovascular Surgery, David Grant USAF Medical Center, Travis Air Force Base, California
3 shared publicationsMichael Austin Johnson
Department of Surgery, UC Davis Medical Center, Sacramento, California
2 shared publications- Todd E. Rasmussen
Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN
2 shared publications Anders J. Davidson
From the Department of Vascular and Endovascular Surgery (T.K.W.), Clinical Investigation Facility (T.K.W., L.P.N.), and Department of General Surgery (L.P.N.), David Grant USAF Medical Center, Travis Air Force Base; and Departments of Emergency Medicine (M.A.J.) and Surgery (R.M.R., S.-A.F., A.J.D.), UC Davis Medical Center, Sacramento, California; and US Combat Casualty Care Research Program (T.E.R.), US Army Medical Research and Materiel Command, Fort Detrick, Maryland
1 shared publication- Anders J. Davidson
Clinical Investigation Facility, David Grant Medical Center, Travis Air Force Base, CA
1 shared publication
Latest Publications
- 1 April 2017
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 82 (4) , 694-703
Automated variable aortic control versus complete aortic occlusion in a swine model of hemorrhage
BACKGROUND: Future endovascular hemorrhage control devices will require features that mitigate the adverse effects of vessel occlusion. Permissive regional hypoperfusion (PRH) with variable aortic control (VAC) is a novel strategy to minimize hemorrhage and reduce the ischemic burden of complete aortic occlusion (AO). The objective of this study was to compare PRH with VAC to AO in a lethal model of hemorrhage. METHODS: Twenty-five swine underwent cannulation of the supraceliac aorta, with diversion of aortic flow through an automated extracorporeal circuit. After creation of uncontrolled liver hemorrhage, animals were randomized to 90 minutes of treatment: Control (full, unregulated flow; n = 5), AO (no flow; n = 10), and PRH with VAC (dynamic distal flow initiated after 20 minutes of AO; n = 10). In the PRH group, distal flow rates were regulated between 100 and 300 mL/min based on a desired, preset range of proximal mean arterial pressure (MAP). At 90 minutes, damage control surgery, resuscitation, and restoration of full flow ensued. Critical care continued for 4.5 hours or until death. Hemodynamic parameters and markers of ischemia were recorded. RESULTS: Study survival was 0%, 50%, and 90% for control, AO, and VAC, respectively ( p < 0.01). During intervention, VAC resulted in more physiologic proximal MAP (84 ± 18 mm Hg vs. 105 ± 9 mm Hg, p < 0.01) and higher renal blood flow than AO animals ( p = 0.02). During critical care, VAC resulted in higher proximal MAP (73 ± 8 mm Hg vs. 50 ± 6 mm Hg, p < 0.01), carotid and renal blood flow ( p < 0.01), lactate clearance ( p < 0.01), and urine output ( p < 0.01) than AO despite requiring half the volume of crystalloids to maintain proximal MAP ≥50 mm Hg ( p < 0.01). CONCLUSION: Permissive regional hypoperfusion with variable aortic control minimizes the adverse effects of distal ischemia, optimizes proximal pressure to the brain and heart, and prevents exsanguination in this model of lethal hemorrhage. These findings provide foundational knowledge for the continued development of this novel paradigm and inform next-generation endovascular designs.
- 1 April 2017
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 82 (4) , 694-703
Automated variable aortic control versus complete aortic occlusion in a swine model of hemorrhage
BACKGROUND: Future endovascular hemorrhage control devices will require features that mitigate the adverse effects of vessel occlusion. Permissive regional hypoperfusion (PRH) with variable aortic control (VAC) is a novel strategy to minimize hemorrhage and reduce the ischemic burden of complete aortic occlusion (AO). The objective of this study was to compare PRH with VAC to AO in a lethal model of hemorrhage. METHODS: Twenty-five swine underwent cannulation of the supraceliac aorta, with diversion of aortic flow through an automated extracorporeal circuit. After creation of uncontrolled liver hemorrhage, animals were randomized to 90 minutes of treatment: Control (full, unregulated flow; n = 5), AO (no flow; n = 10), and PRH with VAC (dynamic distal flow initiated after 20 minutes of AO; n = 10). In the PRH group, distal flow rates were regulated between 100 and 300 mL/min based on a desired, preset range of proximal mean arterial pressure (MAP). At 90 minutes, damage control surgery, resuscitation, and restoration of full flow ensued. Critical care continued for 4.5 hours or until death. Hemodynamic parameters and markers of ischemia were recorded. RESULTS: Study survival was 0%, 50%, and 90% for control, AO, and VAC, respectively ( p < 0.01). During intervention, VAC resulted in more physiologic proximal MAP (84 ± 18 mm Hg vs. 105 ± 9 mm Hg, p < 0.01) and higher renal blood flow than AO animals ( p = 0.02). During critical care, VAC resulted in higher proximal MAP (73 ± 8 mm Hg vs. 50 ± 6 mm Hg, p < 0.01), carotid and renal blood flow ( p < 0.01), lactate clearance ( p < 0.01), and urine output ( p < 0.01) than AO despite requiring half the volume of crystalloids to maintain proximal MAP ≥50 mm Hg ( p < 0.01). CONCLUSION: Permissive regional hypoperfusion with variable aortic control minimizes the adverse effects of distal ischemia, optimizes proximal pressure to the brain and heart, and prevents exsanguination in this model of lethal hemorrhage. These findings provide foundational knowledge for the continued development of this novel paradigm and inform next-generation endovascular designs.
- 1 September 2016
- Published by Wolters Kluwer Health in Shock
- Vol. 46 (3S) , 12-19
Emerging Endovascular Therapies for Non-Compressible Torso Hemorrhage
Management of non-compressible torso hemorrhage (NCTH) remains a challenge despite continued advancements in trauma resuscitation. Resuscitative thoracotomy with aortic cross-clamping and recent advances in endovascular aortic occlusion, including resuscitative endovascular occlusion of the aorta, have finite durations of therapy due to the inherent physiologic stressors that accompany complete occlusion. Here, we attempt to illuminate the current state of aortic occlusion for trauma resuscitation including explanation of the deleterious consequences of complete occlusion, potential methods and limitations of existing technology to overcome these consequences, and a description of innovative methods to improve the resuscitation of NCTH. By explaining the complexity and potential deleterious effects of resuscitation augmented with aortic occlusion, our goal is to provide practitioners with a real-world perspective on current endovascular technology and to encourage the continued innovation required to overcome existing obstacles.
- 1 September 2016
- Published by Wolters Kluwer Health in Shock
- Vol. 46 (3S) , 12-19
Emerging Endovascular Therapies for Non-Compressible Torso Hemorrhage
Management of non-compressible torso hemorrhage (NCTH) remains a challenge despite continued advancements in trauma resuscitation. Resuscitative thoracotomy with aortic cross-clamping and recent advances in endovascular aortic occlusion, including resuscitative endovascular occlusion of the aorta, have finite durations of therapy due to the inherent physiologic stressors that accompany complete occlusion. Here, we attempt to illuminate the current state of aortic occlusion for trauma resuscitation including explanation of the deleterious consequences of complete occlusion, potential methods and limitations of existing technology to overcome these consequences, and a description of innovative methods to improve the resuscitation of NCTH. By explaining the complexity and potential deleterious effects of resuscitation augmented with aortic occlusion, our goal is to provide practitioners with a real-world perspective on current endovascular technology and to encourage the continued innovation required to overcome existing obstacles.
- Open Access
- 1 August 2016
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 223 (2) , 359-368
Partial Resuscitative Endovascular Balloon Occlusion of the Aorta in Swine Model of Hemorrhagic Shock
Complete resuscitative endovascular balloon occlusion of the aorta (C-REBOA) increases proximal mean arterial pressure (MAP) at the cost of distal organ ischemia, limiting the duration of intervention. We hypothesized that partial aortic occlusion (P-REBOA) would maintain a more physiologic proximal MAP and reduce distal tissue ischemia. We investigated the hemodynamic and physiologic effects of P-REBOA vs C-REBOA. Fifteen swine were anesthetized, instrumented, splenectomized, and subjected to rapid 25% blood volume loss. They were randomized to C-REBOA, P-REBOA, or no intervention (controls). Partial REBOA was created by partially inflating an aortic balloon catheter to generate a 50% blood pressure gradient across the balloon. Hemodynamics were recorded and serum makers of ischemia and inflammation were measured. After 90 minutes of treatment, balloons were deflated to evaluate the immediate effects of reperfusion. End organs were histologically examined. Complete REBOA produced supraphysiologic increases in proximal MAP after hemorrhage compared with more modest augmentation in the P-REBOA group (p < 0.01), with both groups significantly greater than controls (p < 0.01). Less rebound hypotension after balloon deflation was seen in the P-REBOA compared with C-REBOA groups. Complete REBOA resulted in higher serum lactate than both P-REBOA and controls (p < 0.01). Histology revealed early necrosis and disruption of duodenal mucosa in all C-REBOA animals, but none in P-REBOA animals. In a porcine hemorrhagic shock model, P-REBOA resulted in more physiologically tolerable hemodynamic and ischemic changes compared with C-REBOA. Additional work is needed to determine whether the benefits associated with P-REBOA can both extend the duration of intervention and increase survival.
- 1 August 2016
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 223 (2) , 359-368
Open AccessPartial Resuscitative Endovascular Balloon Occlusion of the Aorta in Swine Model of Hemorrhagic Shock
Complete resuscitative endovascular balloon occlusion of the aorta (C-REBOA) increases proximal mean arterial pressure (MAP) at the cost of distal organ ischemia, limiting the duration of intervention. We hypothesized that partial aortic occlusion (P-REBOA) would maintain a more physiologic proximal MAP and reduce distal tissue ischemia. We investigated the hemodynamic and physiologic effects of P-REBOA vs C-REBOA. Fifteen swine were anesthetized, instrumented, splenectomized, and subjected to rapid 25% blood volume loss. They were randomized to C-REBOA, P-REBOA, or no intervention (controls). Partial REBOA was created by partially inflating an aortic balloon catheter to generate a 50% blood pressure gradient across the balloon. Hemodynamics were recorded and serum makers of ischemia and inflammation were measured. After 90 minutes of treatment, balloons were deflated to evaluate the immediate effects of reperfusion. End organs were histologically examined. Complete REBOA produced supraphysiologic increases in proximal MAP after hemorrhage compared with more modest augmentation in the P-REBOA group (p < 0.01), with both groups significantly greater than controls (p < 0.01). Less rebound hypotension after balloon deflation was seen in the P-REBOA compared with C-REBOA groups. Complete REBOA resulted in higher serum lactate than both P-REBOA and controls (p < 0.01). Histology revealed early necrosis and disruption of duodenal mucosa in all C-REBOA animals, but none in P-REBOA animals. In a porcine hemorrhagic shock model, P-REBOA resulted in more physiologically tolerable hemodynamic and ischemic changes compared with C-REBOA. Additional work is needed to determine whether the benefits associated with P-REBOA can both extend the duration of intervention and increase survival.
- 1 August 2016
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 81 (2) , 294-301
Extending resuscitative endovascular balloon occlusion of the aorta
BACKGROUND The duration of use and efficacy of resuscitative endovascular balloon occlusion of the aorta (REBOA) is limited by distal ischemia. We developed a hybrid endovascular-extracorporeal circuit variable aortic control (VAC) device to extend REBOA duration in a lethal model of hemorrhagic shock to serve as an experimental surrogate to further the development of endovascular VAC (EVAC) technologies. METHODS Nine Yorkshire-cross swine were anesthetized, instrumented, splenectomized, and subjected to 30% liver amputation. Following a short period of uncontrolled hemorrhage, REBOA was instituted for 20 minutes. Automated variable occlusion in response to changes in proximal mean arterial pressure was applied for the remaining 70 minutes of the intervention phase using the automated extracorporeal circuit. Damage-control surgery and whole blood resuscitation then occurred, and the animals were monitored for a total of 6 hours. RESULTS Seven animals survived the initial surgical preparation. After 20 minutes of complete REBOA, regulated flow was initiated through the extracorporeal circuit to simulate VAC and provide perfusion to distal tissue beds during the 90-minute intervention phase. Two animals required circuit occlusion for salvage, while five animals tolerated sustained, escalating restoration of distal blood flow before surgical hemorrhage control. Animals tolerating distal flow had preserved renal function, maintained proximal blood pressure, and rapidly weaned from complete REBOA. CONCLUSION We combined a novel automated, extracorporeal circuit with complete REBOA to achieve EVAC in a swine model of uncontrolled hemorrhage. Our approach regulated proximal aortic pressure, alleviated supranormal values above the balloon, and provided controlled distal aortic perfusion that reduced ischemia without inducing intolerable bleeding. This experimental model serves as a temporary surrogate to guide future EVAC catheter designs that may provide transformational approaches to hemorrhagic shock.
- 1 August 2016
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 81 (2) , 294-301
Extending resuscitative endovascular balloon occlusion of the aorta
BACKGROUND The duration of use and efficacy of resuscitative endovascular balloon occlusion of the aorta (REBOA) is limited by distal ischemia. We developed a hybrid endovascular-extracorporeal circuit variable aortic control (VAC) device to extend REBOA duration in a lethal model of hemorrhagic shock to serve as an experimental surrogate to further the development of endovascular VAC (EVAC) technologies. METHODS Nine Yorkshire-cross swine were anesthetized, instrumented, splenectomized, and subjected to 30% liver amputation. Following a short period of uncontrolled hemorrhage, REBOA was instituted for 20 minutes. Automated variable occlusion in response to changes in proximal mean arterial pressure was applied for the remaining 70 minutes of the intervention phase using the automated extracorporeal circuit. Damage-control surgery and whole blood resuscitation then occurred, and the animals were monitored for a total of 6 hours. RESULTS Seven animals survived the initial surgical preparation. After 20 minutes of complete REBOA, regulated flow was initiated through the extracorporeal circuit to simulate VAC and provide perfusion to distal tissue beds during the 90-minute intervention phase. Two animals required circuit occlusion for salvage, while five animals tolerated sustained, escalating restoration of distal blood flow before surgical hemorrhage control. Animals tolerating distal flow had preserved renal function, maintained proximal blood pressure, and rapidly weaned from complete REBOA. CONCLUSION We combined a novel automated, extracorporeal circuit with complete REBOA to achieve EVAC in a swine model of uncontrolled hemorrhage. Our approach regulated proximal aortic pressure, alleviated supranormal values above the balloon, and provided controlled distal aortic perfusion that reduced ischemia without inducing intolerable bleeding. This experimental model serves as a temporary surrogate to guide future EVAC catheter designs that may provide transformational approaches to hemorrhagic shock.