Chuan Sheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chuan Sheng has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Haoyang Shi
Air Defense and Anti-Missile Academy, Air Force Engineering University, Xi’an 710051, China
1 shared publication - Heming Wang
State Environmental Protection Key Laboratory of Eco‐Industry Northeastern University Shenyang China
1 shared publication - Junwei Xie
Air and Missile Defense College, Air Force Engineering University, Xi’an 710051, China
1 shared publication - Kun Wang
Air Defense and Anti-Missile Academy, Air Force Engineering University, Xi’an 710051, China
1 shared publication - Lin Huang
Air Defense and Anti-Missile Academy, Air Force Engineering University, Xi’an 710051, China
1 shared publication - Wenlong Lu
Shanghai Jiao Tong University, Shanghai, China
1 shared publication
Latest Publications
- Open Access
Research on the Dielectric Constant Sensor System Based on the Short-Ended Transmission Line
This paper presents a sensor system for measuring the dielectric constant of materials, with a control circuit, a broadband coupler and a sensing probe as its main components. The entire system can independently measure the dielectric constant of powdered solid materials and liquid materials without relying on any auxiliary equipment. According to the transmission line design theory, the sensing probe utilizes a short-ended transmission line based on air coplanar waveguide. By introducing a parallel resistor at the input of the transmission line, material under test (MUT) with different dielectric constant can directly influence the resonance frequency of the transmission line’s reflection coefficient. The dielectric constant can be inverted through the measurement of the resonance frequency. This paper systematically analyzes the sufficient condition for the validity of the conclusion and discusses interference factors that may affect the measurement result, such as variation in resistor value and difference in material loss. Subsequently, a dedicated control circuit was designed and manufactured by integrating a control chip, an RF chip, and a detector, thus forming a low-cost, portable sensor system together with the sensing probe and coupler. Experimental tests were conducted on six different MUTs, and the results confirmed that the system has the capability to accurately characterize the dielectric constant of powdered solid and liquid material. Compared to other sensor systems, the proposed system features a simplified design and higher measurement precision, indicating its broad applicability in radio frequency identification.
Open AccessResearch on the Dielectric Constant Sensor System Based on the Short-Ended Transmission Line
This paper presents a sensor system for measuring the dielectric constant of materials, with a control circuit, a broadband coupler and a sensing probe as its main components. The entire system can independently measure the dielectric constant of powdered solid materials and liquid materials without relying on any auxiliary equipment. According to the transmission line design theory, the sensing probe utilizes a short-ended transmission line based on air coplanar waveguide. By introducing a parallel resistor at the input of the transmission line, material under test (MUT) with different dielectric constant can directly influence the resonance frequency of the transmission line’s reflection coefficient. The dielectric constant can be inverted through the measurement of the resonance frequency. This paper systematically analyzes the sufficient condition for the validity of the conclusion and discusses interference factors that may affect the measurement result, such as variation in resistor value and difference in material loss. Subsequently, a dedicated control circuit was designed and manufactured by integrating a control chip, an RF chip, and a detector, thus forming a low-cost, portable sensor system together with the sensing probe and coupler. Experimental tests were conducted on six different MUTs, and the results confirmed that the system has the capability to accurately characterize the dielectric constant of powdered solid and liquid material. Compared to other sensor systems, the proposed system features a simplified design and higher measurement precision, indicating its broad applicability in radio frequency identification.
- Open Access
- 26 July 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1177
Non-stationary component extraction in noisy multicomponent signal using polynomial chirping Fourier transform
Inspired by track-before-detection technology in radar, a novel time–frequency transform, namely polynomial chirping Fourier transform (PCFT), is exploited to extract components from noisy multicomponent signal. The PCFT combines advantages of Fourier transform and polynomial chirplet transform to accumulate component energy along a polynomial chirping curve in the time–frequency plane. The particle swarm optimization algorithm is employed to search optimal polynomial parameters with which the PCFT will achieve a most concentrated energy ridge in the time–frequency plane for the target component. The component can be well separated in the polynomial chirping Fourier domain with a narrow-band filter and then reconstructed by inverse PCFT. Furthermore, an iterative procedure, involving parameter estimation, PCFT, filtering and recovery, is introduced to extract components from a noisy multicomponent signal successively. The Simulations and experiments show that the proposed method has better performance in component extraction from noisy multicomponent signal as well as provides more time–frequency details about the analyzed signal than conventional methods.
- 26 July 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1177
Open AccessNon-stationary component extraction in noisy multicomponent signal using polynomial chirping Fourier transform
Inspired by track-before-detection technology in radar, a novel time–frequency transform, namely polynomial chirping Fourier transform (PCFT), is exploited to extract components from noisy multicomponent signal. The PCFT combines advantages of Fourier transform and polynomial chirplet transform to accumulate component energy along a polynomial chirping curve in the time–frequency plane. The particle swarm optimization algorithm is employed to search optimal polynomial parameters with which the PCFT will achieve a most concentrated energy ridge in the time–frequency plane for the target component. The component can be well separated in the polynomial chirping Fourier domain with a narrow-band filter and then reconstructed by inverse PCFT. Furthermore, an iterative procedure, involving parameter estimation, PCFT, filtering and recovery, is introduced to extract components from a noisy multicomponent signal successively. The Simulations and experiments show that the proposed method has better performance in component extraction from noisy multicomponent signal as well as provides more time–frequency details about the analyzed signal than conventional methods.